Tie down bolt
on each end
Select appropriate
duct cutout
(see ducting installation instructions).
Pressure regulator
Wiring box cover
Grease
container
9-1/2
29 ±1/16
1-7/8"
Min.
15/16"
Min.
clearance
Blower can be swiveled 90°
14-3/16
9
30
21-3/4
21 ±1/16
PGP990DEN
GE Profile™ Built-In Downdraft Gas Cooktop
Dimensions and Installation Information (in inches)
Wall Installation: Wall installations require 25” countertop
When cabinet is flush against the wall, the fan housing can be rotated
to the horizontal position for direct venting through rear wall. Make a
countertop cutout in the range cabinet according to unit dimensions
and installation type. Duct hole is positioned in back of cabinet for
through-the-wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a minimum 26”
countertop
Island or peninsula cabinets may require adjustment in cutout depth
and/or location within the width dimensions. Duct hole is positioned in
bottom of cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation
and rear wall ducting, 6” PVC duct or locally approved piping
should be used if installing under a poured concrete slab.
Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional data.
Note: These cooktops are approved for indoor use only.
Warranty Information:
Parts Warranty - Limited 1-year entire appliance
Labor Warranty - Limited 1-year entire appliance
Warranty Notes - For models produced on or after January 1, 2006;
see written warranty for full details
depth is suggested. Blower should be in vertical position.
depth.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center® service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Revised 7/10
230282
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
PGP990DEN
GE Profile™ Built-In Downdraft Gas Cooktop
Dimensions and Installation Information (in inches)
Installing the Ductwork: Use galvanized
or aluminum duct in 6” round or 3-1/4” x
10” size, or combination of both. PVC duct
or locally approved piping should be used
if installing under a poured concrete slab.
Local building code must be followed in
specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside.
Do not vent into a wall, ceiling, crawlspace,
attic or any concealed space. Always use
an appropriate roof or wall cap with damper.
Laundry-type wall caps should never
be used. For maximum efficiency use the
shortest and straightest duct run possible,
with as few fittings as possible.
For satisfactory
should not exceed 100 feet equivalent length.
Refer to the table of equivalent lengths
(shown in installation instructions) for
various duct configurations.
performance the duct run
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center® service,
800.626.2000.