General Electric PGP990DENBB User Manual

Tie down bolt
on each end
Select appropriate duct cutout (see ducting installation instructions).
Pressure regulator
Wiring box cover Grease container
9-1/2
29 ±1/16
1-7/8" Min.
15/16"
Min.
clearance
Blower can be swiveled 90°
14-3/16
9
30
21-3/4
21 ±1/16
PGP990DEN
GE Profile™ Built-In Downdraft Gas Cooktop
Dimensions and Installation Information (in inches)
Wall Installation: Wall installations require 25” countertop
When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a countertop cutout in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the-wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a minimum 26” countertop Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and rear wall ducting, 6” PVC duct or locally approved piping
should be used if installing under a poured concrete slab. Installation Information: Before installing, consult installation
instructions, packed with product, for current dimensional data.
Note: These cooktops are approved for indoor use only. Warranty Information:
Parts Warranty - Limited 1-year entire appliance Labor Warranty - Limited 1-year entire appliance Warranty Notes - For models produced on or after January 1, 2006; see written warranty for full details
depth is suggested. Blower should be in vertical position.
depth.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Revised 7/10
230282
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
PGP990DEN
GE Profile™ Built-In Downdraft Gas Cooktop
Dimensions and Installation Information (in inches)
Installing the Ductwork: Use galvanized
or aluminum duct in 6” round or 3-1/4” x 10” size, or combination of both. PVC duct
or locally approved piping should be used if installing under a poured concrete slab.
Local building code must be followed in specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper.
Laundry-type wall caps should never be used. For maximum efficiency use the
shortest and straightest duct run possible, with as few fittings as possible. For satisfactory should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations.
performance the duct run
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service,
800.626.2000.
Listed by Underwriters Laboratories
Specification Revised 7/10
230282