MUSE
Cardiology Information System
Advanced Security Guide
Software Version 7.0.2
2033425-029 Revision A
Page 2
earlier software versions. Due to continuing product innovation, specifications in this manual are subject to change without notice.
MUSE™ and InSite™ are trademarks owned by GE Medical Systems Information Technologies, a General Electric Company going to market as GE Healthcare. All other trademarks contained herein are the property of their respective owners.
© 2006 General Electric Company. All rights reserved.
T-2 MUSE Revision A
2033425-029 29 September 2006
Page 3
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Checklist for MUSE Security Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
MUSE Features Which Require Policies/Procedures . . . . . . . . . . . . . . . . . . . . . . . 1-4
Access Control Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
User Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Windows Authentication vs. MUSE Authentication . . . . . . . . . . . . . . . . . . . . . . . .1-6
Allow MUSE Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Unattended Workstation Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Accounting/Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8
Print Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8
Change Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9
Logging of System Security Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-10
Disabling Remote Query & User Entered Destination . . . . . . . . . . . . . . . . . . . . . 1-11
MUSE Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Configure IIS to Log Web Site Activity on MUSE Web . . . . . . . . . . . . . . . . . . . .1-12
Setting Up Client Browser for 128-bit Encryption . . . . . . . . . . . . . . . . . . . . . . . . .1-13
Anti-Virus Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
Microsoft Security Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
Appendix A – HIPAA Overview . . . . . . . . . . . . . . . . . . . . .A-1
HIPAA Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
HIPAA Law Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Privacy and Confidentiality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6
Electronic Health Transactions and Code Sets Standards . . . . . . . . . . . . . . . . . . A-7
HIPAA Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-9
Policy and Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-9
Achieving HIPAA Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-10
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-11
Revision A MUSE i
2033425-029
Page 4
How HIPAA-Compliant Can Any Technology Be? . . . . . . . . . . . . . . . . . . . . . . . . A-12
Transactions Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-12
Privacy Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-12
Security Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
Overall... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-13
Appendix B – Summary of MUSE Security . . . . . . . . . . . .B-1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Background Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Network Presence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Transactions, Code Sets, and Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Identify all of the identifiers this product supports . . . . . . . . . . . . . . . . . . . . . . . . B-4
User Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
User Account Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Authorizations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
Auto-Logoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Device to Device Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Log All Security Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Log All Patient Data Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Log All Patient Data Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Log All Changes to the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Audit Log Viewing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Audit Log Mining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-10
Configuration Lockdown & Security Fixes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-11
AntiVirus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-12
Integrity Controls on Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-12
Backup and Recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
Encryption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
De-Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
ii MUSE Revision A
2033425-029
Page 5
Digital Signatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
Appendix C – 21 CFR Part 11 Option . . . . . . . . . . . . . . . .C-1
Electronic Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Other 21 CFR Part 11 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-4
Disable Automatic Updates to Report Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-4
Revision A MUSE iii
2033425-029
Page 6
iv MUSE Revision A
2033425-029
Page 7

Introduction

Advanced Security Guide: Introduction
The MUSE Cardiology Information System (system) has several security features which, when properly used and configured, can support USA facilities in complying with the Health Insurance Portability and Accountability Act (HIPAA) Security and Electronic Signature Standards. These new security standards were designed to protect patient’s health information from improper access, alteration, and loss when it is maintained or transmitted electronically.
For more information on the HIPAA Security and Electronic Signature Standards link to:
http://ge.com/hipaa
Compliance with the HIPAA Security and Electronic Signature Standards cannot be attained solely through the use of the security features on the MUSE system. Sites which use the MUSE system to maintain and transmit patient health information must use the security features in conjunction with a security plan which provides for the user training and secure physical access to patient health information.
This document is provided to describe how to properly set up and use the security features on the MUSE system. The responsibility of developing the security plan for user training and secure physical access to patient health lies with the end user.
If you have any questions or need assistance with any of these security setups, call the Jupiter On-Line Center at 1-800-558-7044.
Revision A MUSE 1
2033425-029
Page 8

Revision History

Advanced Security Guide: Revision History
Each page of the document has the document part number followed by a revision letter at the bottom of the page. This letter identifies the document’s update level. The revision history of this document is summarized in the table below.
Table 1. Revision History, PN 2033425-029
Revision Date Comment
A 29 September 2006 Initial release of manual for version 7.0.2.
2 MUSE Revision A
2033425-029
Page 9
Advanced Security Guide: Checklist for MUSE Security Features

Checklist for MUSE Security Features

When setting up security on the system, use the following checklist as a reminder of security features available on the system which address both HIPAA and FDA 21 CFR Part 11 requirements. Shaded features are not required for 21 CFR Part 11 compliance but are considered good security practices.
FDA
Requirement
Authentication
&
Authorization
Accounting
&
Tracking
MUSE Feature Configuration Recommended Solution
Access Control Security
User Authentication
Unattended Workstation Security
Windows Event Log
Audit Trails Editor Security Enable the Change Log
Secure Configuration
MUSE Users’ Password
Windows Authentication
Logout or Lockout Screen Savers
Audit Policy
Remote Query ‘Remote Query’ feature is disabled. User Entered
Destination
MUSEAdmin, MUSEBkgnd, and MUSE Users’ passwords should adhere to facility’s best practice or policy.
Windows Users should be mapped to MUSE Users.
“Allow Only Windows Authentication” option is installed
All workstations are configured to use “Logout Screen Saver” or “Lockout Screen Saver.”
The Windows utility “Audit Policy” is set on MUSE Sever and all workstations to log certain events.
“User Entered Destination” feature is disabled.
*
 
Web Encryption
&
Logging
Data Integrity Anti Virus
* Enabling of this feature requires the assistance of the Jupiter On-Line Support Center. Please dial 1-800-558-7044 to request
assistance with activating this feature.
MUSE Web
SSL Encryption
SSL Logging
Anti Virus Software Configuration
MUSE file server is set to use SSL to force 128-bit encryption.
MUSE file server is set to use IIS to log MUSE Web activities.
Anti-virus software is installed and properly configured on MUSE file server and all workstations.
Revision A MUSE 3
2033425-029
Page 10
Advanced Security Guide: MUSE Features Which Require Policies/Procedures

MUSE Features Which Require Policies/Procedures

The following MUSE features require policies and procedures to achieve security compliance.
Policies and Procedures Required for HIPAA & 21 CFR Part II
Security Compliance
MUSE Feature
HL7 Device
Folder, FTP Folder, Email
MUSE API
Fax
Remote Query
Why a Policy/Procedure is
Needed
Patient Data leaving the system, thus, no longer change logging or protecting access of records.
Patient Data leaving the system, thus, no longer change logging or protecting access of records.
Data is leaving the system and may not be under any security control.
Faxed information can be viewed by anyone, thus a policy should be in place regarding cover pages, and confidentiality of patient information. Work with your legal department in developing these policies/ procedures.
Data is leaving the system and may not be under any security control.
Data is leaving the system and
Allowing users to enter destination
Policies and Procedures Required for 21 CFR Part II Security Compliance
Feature
Acquiring ECGs require Technicians to enter ID Number at cart
4 MUSE Revision A
2033425-029
may not be under any security control.
Why a Policy/Procedure is
Needed
Data leaves the system and not under any security control
Page 11
Advanced Security Guide: Access Control Security

Access Control Security

The MUSE system requires two Windows user accounts. One that is used by GE Service to access and work on the system, and the other is used by the system itself to run background Windows Services. This section of the Advanced Security Guide describes these user accounts, how they are used, and what the system requirements are for the accounts.
1. MUSEAdmin account. This account is used by GE Service to log into the system to perform initial setup and configuration, and to provide on-going service and support. This account needs to be a member of the Administrators Group on the MUSE file server. The customer should not use this account. For tracking and auditing reasons, customers should use their own account. The MUSEAdmin account should be a domain account whenever possible. As a workaround, it can be an account local to the MUSE file server.
The password for the MUSEAdmin account can be determined by the customer, but must be shared with GE Service so that they can use that account when they work on the system.
2. MUSEBkgnd account. This account is used to start the MUSE related background services on the MUSE file server. This account needs to be a member of the Administrators Group on the MUSE file server. This account should not be used by anyone for logging on to the MUSE system. The MUSEBkgnd account should be a domain account whenever possible. As a workaround, it can be local to the MUSE file server.
The password for the MUSEBkgnd account can be determined by the customer, but must be shared with GE Service so that they can use that account when they work on the system.
The MUSEBkgnd account must not be subject to any policies that would not allow the account the Logon As Service right, since that right is a requirement for the account to be able to start the MUSE related background services.
Passwords for the Windows MUSEAdmin and MUSEBkgnd user accounts are changed through Windows like any other Windows user account. Both accounts should have passwords that are set to never expire. If the passwords change, GE Service may not be able to log into the system to provide support, and the background services will fail to start, causing the MUSE system to stop functioning.
All other users of the MUSE system can use their normal Windows user credentials to access the MUSE system. Inside the MUSE application the users are setup with their Domain\User account information, but no password information is required when configuring a user. The user passwords can be controlled or changed through Windows as required.
Revision A MUSE 5
2033425-029
Page 12
Advanced Security Guide: User Authentication

User Authentication

Windows Authentication vs. MUSE Authentication

Using Windows Authentication on a MUSE workstation not only eliminates a second logon using MUSE Authentication, but also supports a higher level of security as is recommended to meet HIPAA compliance standards.
MUSE authentication is most commonly used on a client workstation that is shared by multiple users, and where those users do not want to log out of Windows and log back in to run the MUSE application and be recognized as a different user. Each person that runs the MUSE application on the shared workstation can log into MUSE with their own username and password. In order to help meet HIPAA compliance, policies and procedures will need to be in place when using MUSE authentication.
With Windows authentication, users are not required to log into the MUSE application separately. When the MUSE application is launched, MUSE will automatically log them in as the proper user, based on the user that is logged into Windows on that computer. Windows authentication supports a higher level of security as recommended to meet HIPAA compliance standards.

Allow MUSE Authentication

By default, the system allows either MUSE or Windows Authentication. To disable MUSE Authentication on the system so that Windows authentication can be used, contact the Jupiter On-Line Support Center at 1-800-558-7044, or contact your regional support center if you are outside the United States.
If MUSE Authentication is allowed, it can be enabled at individual workstations by adding the following switch to the shortcut that is used to launch MUSE: -museauthenticate.
If MUSE authentication is disabled and a user tries to log in using MUSE authentication, a message will appear stating MUSE authentication is not enabled. If a user is logged into the system using their correct Windows authentication, an error message appears, but they will be allowed into the system. If a user is logged into a system as a different user and logs in using MUSE authentication, the error message appears and they will not be allowed into the system.

Unattended Workstation Security

There are two options available to you for setting up logout/lockout security on workstations which are left unattended for a specified amount of time. The two options are:
6 MUSE Revision A
2033425-029
Page 13
Advanced Security Guide: User Authentication
1. Logout. When workstation is inactive (no mouse or keyboard input) for the specified amount of time, the current user is logged off Windows and the MUSE session is ended.
2. Lockout. When workstation is inactive for the specified amount of time, the screen saver selected in the Control Panel is activated.
The table below summarizes these two options for unattended workstation security. Be sure you understand how each option impacts the user before choosing one of these options. Inform all system users about how the unattended workstation security option affects their use of the system.
Table 2. Differences Between the Two Options for Unattended Workstation Security
Item
Logout Screen Saver
WINEXIT
Lockout Screen Saver
Logon with Password Protected
Access will be terminated after predetermined time of inactivity Yes Yes Require authentication to log back into system Yes Yes Workstation is locked No Yes
Users can unlock workstation N/A
MUSE application exit Yes
Last userAdministrator
No, if Last user unlocks the workstationYes, if Administrator unlocks the
workstation
No, if Last user unlocks the workstation
Lose unsaved changes Yes
Yes, if Administrator unlocks the
workstation
*
Possibility of locking record that was being edited when screen saver took control.
Yes
No, if Last user unlocks the workstationYes, if Administrator unlocks the
workstation
* If a record is locked, a message will be displayed indicating the record is being used by another workstation. The message will
display the Node ID of the workstation that has locked the record. To unlock the record, a user with sufficient privileges can logon the workstation which has locked the record and start the MUSE application.
Revision A MUSE 7
2033425-029
Page 14
Advanced Security Guide: Accounting/Logging

Accounting/Logging

Print Log

Outbound events refers to data that is sent out of the system, such as patient tests, reports, sending out lists for printing, etc.
The system logs the following outbound events:
Printing to Postscript and PCL printers Fax CSI Email HL7 Folder FTP Folder
These outbound events can be viewed in the Print Log. To open the Print Log, select Status > Print Log.
Refer to the MUSE Operator Manual for instructions on configuring the Print Log.
8 MUSE Revision A
2033425-029
Page 15

Change Log

Advanced Security Guide: Accounting/Logging
The Change Log tracks changes to patient data, and can be viewed in Clerical, Clinical ECG and Enhanced layouts of the Report Editor. Click
to open the Change Log window.
Edit Change Log
Process Log
003
Each time a change is made to a patient test, the changes are recorded. After a test has been updated or saved in the database, the changes are saved by date.
The Edit Change Log is a list of changes made to a test's Patient ID, Name, Test Time or Site. The log exists to facilitate finding a test that had incorrect data entered at the device and has since been corrected at the system. Refer to the MUSE Operator Manual for detailed information.
The Process Log is a list of all of the processes that have run on the system. This log includes processes that are currently running and those that have terminated successfully. Current processes can be identified because they do not have an end time. Processes with an old start time and no end time can be used to identify bad processes. Refer to the MUSE Operator Manual for detailed information.
Revision A MUSE 9
2033425-029
Page 16
Advanced Security Guide: Accounting/Logging
5

Logging of System Security Events

The MUSE file server and workstations should be configured to log Windows security events to the Windows Viewer. At each file server and workstation, repeat the following steps to set up this audit.
1. Click Start > Programs > Administrative Tools > Local Security Policy. The Local Security Settings window appears.
2. Select Local Policies > Audit Policy.
3. Click on each event and select the checkboxes indicated in the table below.
Event Success Failure
Audit account logon events Audit account management Audit directory service access Audit logon events Audit object access Audit policy change Audit privilege use Audit process tracking Audit system events
4. Click OK to save your changes.
99
9 9
99
9
99
9 9
99
00
5. Close the Local Security Settings window.
10 MUSE Revision A
2033425-029
Page 17
Advanced Security Guide: Disabling Remote Query & User Entered Destination

Disabling Remote Query & User Entered Destination

1. Select System > Setup > Sites > Properties. Highlight Advanced.
Uncheck to disable CSI Remote Query
Uncheck to disable user entered destinations
2. To disable remote query, uncheck the Enable CSI Remote Query checkbox.
3. To disable printing to temporary devices, uncheck the Enable User Entered Destination checkbox.
4. Click OK.
5. Repeat for each site on the system.
004
Revision A MUSE 11
2033425-029
Page 18
Advanced Security Guide: MUSE Web

MUSE Web

IIS is installed on the MUSE Web server. In order to access the MUSE Web, the user must have their browser configured for 128-bit encryption.
For detailed procedures, see “MUSE Web Server Instruction Guide to Enabling SSL.”

Configure IIS to Log Web Site Activity on MUSE Web

MUSE file server should be configured to enable logging web site activity as follows:
1. Right-click My Computer and select Manage.
2. Expand Services & Application > Internet Application Services > Websites in the list found in the Tree list (left panel).
3. Right-click on MUSE Web Site and select Properties in the Web Site tab.
4. Ensure that Enable Logging is checked in the Web Site tab.
5. For Active log format, make sure it is W3C Extended Log File Format.
6. Select Properties....
Select the General tab.
Select Weekly for New Log Time Period.
Make sure Log file directory is
%WinDir%\System32\LogFiles.
Select Advanced tab.
Add/delete/verify checkmarks to obtain the following Extended
Logging Options.
Date
9
Time
9
Client IP Address
9
User Name
9
P Service Name
Server Name
9
Server IP
9
Server Port Method
9
9
URI Query Http Status
Win32 Status Bytes Sent Bytes Received Time Taken Protocol Version User Agent Cookie Referred
Click OK to close the Logging Properties window. Click OK again
to close the Web Site Properties.
12 MUSE Revision A
2033425-029
Page 19
Advanced Security Guide: MUSE Web

Setting Up Client Browser for 128-bit Encryption

MUSE Web server will allow only 128-bit encryption accesses. Users will need to update their Internet Explorer (IE) 5.0 or 6.0 to have “High Encryption Pack” installed.
NOTE
The High Encryption Pack can be downloaded from the Microsoft web site.
The steps below describe how to determine the IE encryption level.
1. Start Internet Explorer.
2. Select Help > About Internet Explorer.
3. If Cipher Strength is less than 128-bit, you will need to install High Encryption Pack.
Revision A MUSE 13
2033425-029
Page 20
Advanced Security Guide: Anti-Virus Software

Anti-Virus Software

GE has validated the proper operation of the system with Norton Anti­Virus Corporate Edition and McAfee NetShield installed. Either of these two virus protections software applications can be installed on the system without affecting function or performance.
Anti-virus software is not provided with the system and it remains the customer’s responsibility to acquire and install anti-virus software on their system per the recommendations of the manufacturer of the anti­virus software.
See the MUSE Pre-Installation Manual for additional information on installing anti-virus software on the system. When properly used, anti­virus software can protect the system from virus infection and the subsequent data corruption which can result from a virus infection. However, if improperly configured, anti-virus software can cause system degradation.
14 MUSE Revision A
2033425-029
Page 21
Advanced Security Guide: Microsoft Security Updates

Microsoft Security Updates

A list of viruses that pose a significant threat to GE customer product security are posted on the GE Healthcare Security web site. Vulnerability notification to customers will occur through the web site. After security patches have been validated with GE Healthcare products, this information will be included in a memo which can be downloaded from the GE Healthcare web site. A validated security patch can then be downloaded directly from the Microsoft web site and applied to the customer’s GE product.
To check on the latest information regarding validated security patches:
1. Browse to the following site:
http://www.gehealthcare.com/usen/security/products/ modality_links.html
2. Login with your SSO (Single Sign On) username and password.
NOTE
If you are not within the firewall, you will be prompted to register the first time you visit this site.
3. Then, click on the link for the security information for Diagnostic Cardiology. This bulletin includes security patch information for products made by the Diagnostic Cardiology modality of GE Healthcare which require security patches. This list includes the security patches which have been validated for
the system.
Revision A MUSE 15
2033425-029
Page 22
For your notes
Advanced Security Guide: Microsoft Security Updates
16 MUSE Revision A
2033425-029
Page 23
Appendix A – HIPAA Overview:
A Appendix A – HIPAA
Overview
Revision A MUSE A-1
2033425-029
Page 24
Appendix A – HIPAA Overview: HIPAA Introduction

HIPAA Introduction

The future of health care in the United States changed on August 2, 1996 when the Health Insurance Portability and Accountability Act (HIPAA) became law. The complex and far-reaching federal legislation significantly affects every person and organization involved in health care. HIPAA rules spell out standards and requirements for protecting the confidentiality, security, and integrity of all health information.
A-2 MUSE Revision A
2033425-029
Page 25
Appendix A – HIPAA Overview: HIPAA Law Overview

HIPAA Law Overview

The primary goals of HIPAA are quantification of consumer health care rights along with improved privacy and security of medical records. The two main components of HIPAA are Health Care Portability and Administrative Simplification. The Health Care Portability legislation became effective in 1996. The Portability part of HIPAA is well understood and was successfully implemented by the US government and the medical industry in 1996 and 1997. The Portability legislation guarantees the following rights to health care consumers:
Improved availability and accessibility of health insurance
Guaranteed right of portability and continuity of health insurance
coverage for individuals and groups
Prohibits discrimination based on health status
HIPAA’s Administrative Simplification provision is composed of four parts and involves these health care issues:
Standardization of electronic transfers of patient health,
administrative and financial data
Privacy and security standards protecting the confidentiality and
integrity of health information
Unique health identifiers for individuals, employers, health plans
and health care providers
Each part will eventually produce a variety of rules and standards. Many of the rules and standards are under development. As the rules and standards are finalized and become law they will have different compliance deadlines. The four parts of Administrative Simplification are:
1. Electronic Health Transactions Standards
2. Unique Identifiers
3. Security & Electronic Signature Standards
4. Privacy & Confidentiality Standards
HIPAA’s complexity confuses customers. Even the HIPAA name causes confusion. Recently the meaning of the moniker HIPAA changed. Initially HIPAA referred to all parts of the legislation. Current usage narrows HIPAA’s meaning to the rules generated from the Administrative Simplification subsection. GE Medical Systems Information Technologies follows common usage and unless otherwise noted HIPAA refers to the rules developed from the Administrative Simplification subsection.
Revision A MUSE A-3
2033425-029
Page 26
Appendix A – HIPAA Overview: HIPAA Law Overview
The main components of HIPAA and their relationships are presented in Figure 1 below.
HIPAA Act of 1996
Health Care Portability
- Availability & Accessibility Of Health Insurance
- Continuity of Health Insurance Coverage
- Prohibits Discrimination Based on Health Status
Administrative Simplification
(Now called HIPAA)
- Privacy & Security of Health Records
- Standardization of Electronic Transfers
- Unique National Identifiers
Transaction Standard
Privacy Standard
Identifiers Standard
Security Standard
Figure 1. HIPAA Components
The HIPAA component with the greatest impact on GEMS-IT customers is the Privacy Standard. The Privacy Standard is defined in the Administrative Simplification subsection. The Final Version of the Privacy Standard, (Standards for Privacy of Individually Identifiable Health Information, 45 CFR Parts 160 and 164), was published in the Federal Register on December 20, 2000.
A-4 MUSE Revision A
2033425-029
Page 27
Appendix A – HIPAA Overview: HIPAA Law Overview
The HIPAA implementation and enforcement schedule spans several years. The Privacy Standard becomes enforceable on April 14, 2003. Table 1 summarizes the HHS release status and timetable for the HIPAA rules.
Table 1. HIPAA Rules and Rulemaking Timetable
Standard Publication Date Final Ruling
Required
Compliance
1. Insurance Portability Aug 02, 1996 Aug 02, 1996 Jul 01, 1997
2. Electronic Transactions & Code Sets
*
May 07, 1998 Aug 17,2000 Oct 16, 2003
3. Privacy & Confidentiality Nov 03, 1999 Dec 28, 2000 Apr 14, 2003
4. National Provider Identifier May 7, 1998 Expected 2002
5. National Employer Identifier Jun 16, 1998 Expected 2002
6. Security Aug 12, 1998 Expected 2002
7. National Health Plan Identifier In Development
8. Claims Enforcement Procedures In Development
9. National Individual Identifier
**
Withdrawn
* In January, 2002 the Bush Administration extended the deadline for the ‘Electronic Transactions & Code Sets’ from Oct 2002
until October 2003.
** Although the HIPAA law called for a unique health identifier for individuals, HHS and Congress indefinitely postponed any effort
to develop such a standard. (HHS Fact Sheet, Administrative Simplification, 2001)
Revision A MUSE A-5
2033425-029
Page 28
Appendix A – HIPAA Overview: Privacy and Confidentiality

Privacy and Confidentiality

The Final Rule for Privacy was published December 28, 2000. Compliance will be required on April 14, 2003 for most covered entities. In general, privacy is about who has the right to access personally identifiable health information. The rule covers all individually identifiable health information in the hands of covered entities, regardless of whether the information is or has been in electronic form. The Privacy standards limit the non-consensual use and release of private health information; give patients new rights to access their medical records and the right to know who else accessed them; restrict most disclosure of health information to the minimum needed for the intended purpose; establish new criminal and civil sanctions for improper use or disclosure; establish new requirements for access to records by researchers and others.
The Privacy and Confidentiality regulations incorporate five basic patient rights related to health care information:
Consumer Control: The regulation provides consumers with critical
new rights to control the release of their medical information
Boundaries: With few exceptions, an individual’s health care
information should be used for health purposes only, including treatment and payment.
Accountability: Under HIPAA, for the first time, there will be specific
federal penalties if a patient’s right to privacy is violated.
Public Responsibility: The new standards reflect the need to balance
privacy protections with the public responsibility to support such national priorities as protecting public health, conducting medical research, improving the quality of care, and fighting health care fraud and abuse.
Security: It is the responsibility of organizations that are entrusted
with health information to protect it against deliberate or inadvertent misuse or disclosure.
A-6 MUSE Revision A
2033425-029
Page 29
Appendix A – HIPAA Overview: Electronic Health Transactions and Code Sets Standards

Electronic Health Transactions and Code Sets Standards

Health care organizations routinely store and transmit medical information in electronic format. Electronic medical information is manipulated through a wide variety of encoding schemes and formats. Standard electronic data interchange improves the efficiency of health care delivery. National standards make it easier for health plans, doctors, hospitals and other health care providers to process claims and other transactions. (HHS Fact Sheet, Administrative Simplification,
2001) The government and the medical industry perceive standardized representations of routine medical data as beneficial for all parties involved. The Transactions Standards mandates use of standardized electronic formats developed by ANSI, the American National Standards Institute. The Code Set Standards require use of the most commonly used medical terminology code sets. Final standards for electronic transactions and code sets were released in Aug 2000. The original compliance deadline of October 2002 was extended to October 2003.
The Transactions Standards specify the format and content of the following medical transactions:
Health claims or equivalent encounter information transfer
Health claims attachments
Enrollment and disenrollment actions in a health plan
Eligibility status in a health plan
Health care payment and remittance advice
Health plan premium payments
First report of injury
Health claim status
Referral certification and authorization
The Health organizations must adopt standard code sets for all health transactions. Code sets are alphanumeric identifiers representing medical data. Medical coding systems describe diseases, injuries, and other health problems, as well as causes, symptoms and actions taken. All parties exchanging medical transactions must generate and accept the same coding. Consistent coding reduces mistakes, duplication of effort and costs. HIPAA specifies the following commonly used code sets:
1. International Classification of Diseases, 9th Edition, Clinical Modification, (ICD-9-CM), Vols 1, 2, 3
2. National Drug Codes (NDC)
3. Code on Dental Procedures and Nomenclature,
4. Health Care Financing Administration Common Procedure Coding System (HCPCS)
5. Current Procedural Terminology, Fourth Edition (CPT-4),
The Transactions Standards regulate information related to health insurance status and remittance. GEMS-IT cardiology information
Revision A MUSE A-7
2033425-029
Page 30
Appendix A – HIPAA Overview: Electronic Health Transactions and Code Sets Standards
system products are clinical systems and rarely (if ever) process the health insurance and remittance information affected by the Transactions Standards. The GE Medical Systems Information Technologies cardiology information system products are not affected by the Transactions Standards.
The Code Set Standards regulate use of clinical medical information. The Code Set Standards may affect GE Medical Systems Information Technologies cardiology equipment. The cardiology equipment may need to support input of code set values when test information is acquired.
A-8 MUSE Revision A
2033425-029
Page 31
Appendix A – HIPAA Overview: HIPAA Compliance

HIPAA Compliance

HIPAA compliance is achieved through a combination of changes to ‘policy and procedure’ and the purchase of HIPAA enhanced hardware, software, and other technologies. No product can independently confer HIPAA compliance rather the product must fit into a customer specific HIPAA compliance scheme. Technology updates and ‘policy and procedure’ changes are pieced together by customers into a unique and site specific HIPAA compliance solution. The precise mechanisms for achieving HIPAA compliance are left to the covered entities. HIPAA does not mandate specific vendor equipment or mechanisms for achieving compliance. The HIPAA implementers are free to create the systems that enable compliance as they see fit. The HIPAA implementers must decide how much of the compliance will come from new and upgraded technology versus the amount achieved via changing ‘policy and procedure’. HIPAA expects a majority of the compliance can be achieved through ‘policy and procedure’ changes and the remaining compliance achieved via deployment of new and updated technology. The authors of the HIPAA provided guidance concerning policy and procedure in the Federal Register (Dec 28, 2000):

Policy and Procedures

The rule requires that covered entities develop and document policies and procedures with respect to protected health information to establish and maintain compliance with the regulation. Through the standards, requirements, and implementation specifications, we are proposing a framework for developing and documenting privacy policies and procedures rather than adopting a rigid, prescriptive approach to accommodate entities of different sizes, type of activities, and business practices. Small providers will be able to develop more limited policies and procedures under the rule, than will large providers and health plans, based on the volume of protected health information. We also expect that provider and health plan associations will develop model policies and procedures for their members, which will reduce the burden on small businesses.
The myriad of HIPAA compliance solutions presents a difficult challenge to customers. Customers want to stay focused on their primary job of providing quality health care. Customers expect vendors to provide detailed HIPAA guidance tailored to the customer’s unique security needs and health care environment.
Revision A MUSE A-9
2033425-029
Page 32
Appendix A – HIPAA Overview: HIPAA Compliance

Achieving HIPAA Compliance

Achieving HIPAA compliance is a top-down process of learning, planning and implementing. Health care institutions must become intimately familiar with HIPAA rules. The HIPAA implementer must conduct a self-analysis to determine how HIPAA fits into their unique situation. The HIPAA rules must be broken down into understandable categories and tasks. Many internal stakeholders must be consulted in order to ensure full compliance. Once a plan is in place then the HIPAA-enabling technology is purchased and the ‘policy and procedure’ documents created. The last stage is integration and deployment of all the HIPAA mechanisms followed by an audit, ensuring compliance. The HIPAA compliance effort requires strong commitment and detailed planning. The American Health Information Management Association (AHIMA) created the HIPAA Privacy Checklist (2001) to guide to HIPAA implementers:
Get management commitment
Appoint HIPAA team
Perform GAP analysis
Understand current security policy and IT practices
Perform risk analysis
Draft required policies, procedures, and consents
Obtain needed HIPAA-enabling technology
Deploy ‘policy and procedure’ and technology
Audit HIPAA policies, test privacy measures, test security measures
GE Medical Systems Information Technologies can advise and add value at each phase of HIPAA implementation.
A-10 MUSE Revision A
2033425-029
Page 33

References

Appendix A – HIPAA Overview: References
General Electric Medical Systems HIPAA Overview:
http://ge.com/hipaa
Dept. of Health and Human Services, Office of the Secretary, (Dec 28,
2000). Standards for Privacy of Individually Identifiable Health
Information, Comments and Rules, 1535 pages, Federal Register 45 CRF Parts 160 through 164, p 82783
http://www.hhs.gov/ocr/fedreg.zip
Dept. of Health and Human Services, Office of the Secretary, (Dec 28,
2000). Standards for Privacy of Individually Identifiable Health
Information, Rules only 40 pages, Federal Register 45 CRF Parts 160 through 164, p 82783
http://aspe.os.dhhs.gov/admnsimp/final/PvcTxt01.htm
HHS Fact Sheet: Administrative Simplification Under HIPAA: National Standards For Transactions, Security And Privacy. (May 11, 2001). Retrieved from U.S. Department of Health and Human Services Web site:
http://www.hhs.gov/news/press/2001pres/01fshipaa.html
Quarterly Industry HIPAA Survey Results - Summer 2001. (Aug 6,
2001). Retrieved Aug 10, 2001, from Phoenix Health Systems
HIPAAdvisory Web site:
http://www.hipaadvisory.com/action/survey/summer01.htm
HHS FAQ Sheet: The Rule Making Process for Administrative Simplification: What Is Taking So Long? (July 2, 1999) Retrieved from U.S. Department of Health and Human Services Web site:
http://aspe.os.dhhs.gov/admnsimp/8steps.htm
HIPAA Primer, Retrieved Nov 29, 2001,from Phoenix Health Systems HIPAAdvisory Web site:
http://www.hipaadvisory.com/regs/HIPAAprimer1.htm
HIPAA Privacy Checklist, Retrieved Aug 10, 2001, from the American Health Information Management Association Web site:
http://www.ahima.org/journal/pb/01.06.1.html
Information on Microsoft solutions for the healthcare industry and for a copy of Microsoft’s HIPAA Technical White Paper.
http://www.microsoft.com/business/health
Revision A MUSE A-11
2033425-029
Page 34
Appendix A – HIPAA Overview: How HIPAA-Compliant Can Any Technology Be?

How HIPAA-Compliant Can Any Technology Be?

By Roy Rada, M.D., Ph.D. Department of Information Systems University of Maryland, Baltimore County
American history has witnessed a myriad of compliance activities; some we might point with pride to, such as the 1906 Pure Food and Drug Act, resulting from Dr. Harvey Wiley’s efforts to regulate the content of food. However, the role of government in regulating business in the US has often been accompanied by controversy and debate.
HIPAA has proved to be another battleground for compliance. Without going further into the history, politics, law, or ethics of compliance, let’s address the seemingly simple question of whether information technology can be compliant with HIPAA.
How many times have you heard a vendor tout ‘my technology is HIPAA compliant’? Some providers and payers are demanding to get HIPAA compliant technology. Claims are commonly made by salespeople that their product is HIPAA compliant. What’s the scoop here?

Transactions Rule

Direct compliance with HIPAA’s administrative simplification provisions is not practical because the law itself is too indirect. It calls for rules to be developed and enforced by the executive branch of the federal government. Furthermore, the rules are diverse and cover, at least, transactions, privacy, and in proposed-form security.
Might an IT vendor rightfully claim to be compliant with the Transactions Rule? ‘Transaction’ refers in the HIPAA-context to provider-payer transaction. The Transactions Rule calls for compliance with certain standards, particularly X12 formats. A health care provider might want to use information systems that support message formats to payers that are compliant with X12, and a vendor could claim to provide such X12-compliant forms.
This is not to say that the entity buying the technology would have an instant fix to its ‘Transactions’ compliance problem. The Transactions Rule goes beyond the X12 formats to specify the codes that have to be used inside the fields of the format. Achieving compliance with some coding requirements may entail changes in behavior. However, technology could enforce the use of Transaction Rule formats and codes and thus support compliance with the HIPAA transaction rule.

Privacy Rule

Privacy calls for changes in the way an entity manipulates information. This is largely an administrative rather than a technical issue. However, a technology can support the options for manipulating information and be a vital support of the entity behavior. The technology should support behavior consistent with the Privacy Rule.
A-12 MUSE Revision A
2033425-029
Page 35

Security Rule

Appendix A – HIPAA Overview: How HIPAA-Compliant Can Any Technology Be?
The Privacy Rule calls for information systems that represent and audit workflow. Exactly what the workflow should be is not precisely defined. The approach of the Privacy Rule is like the ISO (the pre-eminent international standards organization) approach to quality in ISO 9000. ISO 9000 says that an organization should be clear in its goals and work consistently to those goals. ISO 9000 does not say what the organization­specific goals should be, but an organization can be certified as ISO 9000 compliant. To be ISO 9000 compliant an organization must document its objectives and document that its activities take it towards its objectives – nothing more. The Privacy Rule goes beyond ISO 9000 in specifying broadly what some of the privacy objectives are but then asks entities to be quality organizations as respect to those objectives.
Entities must document working towards privacy objectives. Certifying compliance for privacy would require an analysis of the organizational manual and the way the organization implemented its manual. An IT tool should help a health care entity have and follow the appropriate organizational manual but the tool would not make the entity HIPAA compliant.

Overall...

No security rule has been finalized for HIPAA. Yet, security is the topic that comes closest to what an IT vendor feels is the special turf of the vendor. The typical health care entity may be violating various security mandates, such as transmitting information over the Internet in encrypted form. A vendor can provide tools that encrypt messages before sending them across the Internet.
The proposed security rule gives objectives of secure transmissions, reliable authentication, contingency preparations, and much more. However, the proposed rule gives flexibility to organizations in their choice of ways to achieve the objectives and is neutral about particular technologies. The compliance argument about security is not dissimilar to the argument about privacy: when an organization uses a technology in a certain way to reach a certain objective, then the organization will have behaved in a compliant way as regards that HIPAA security objective.
The bottom line is that Administrative Simplification is about Administration, and technology can support that administration – but not replace it. An information technology vendor should help its clients understand what parts of HIPAA compliance are supported by the vendor’s technology. But it should not claim that the technology is HIPAA compliant.
Revision A MUSE A-13
2033425-029
Page 36
Appendix A – HIPAA Overview: How HIPAA-Compliant Can Any Technology Be?
A-14 MUSE Revision A
2033425-029
Page 37
Appendix B – Summary of MUSE Security:
B Appendix B – Summary
of MUSE Security
Revision A MUSE B-1
2033425-029
Page 38
Introduction
Appendix B – Summary of MUSE Security: Introduction
The following table is based on a MUSE system with 7.0.2 software with no MUSE Web option. These tables are in direct response to the need for security features in medical systems. GE provides these answers to assist you in discovering your risks and in the creation of your mitigation plan. GE provides these answers to the best of our knowledge given the requirements and current state of the product.
This document contains a summary of the Legal Requirements of Health Insurance Portability and Accountability Act (HIPAA). It is not intended as legal advice. Every entity must make its own judgment regarding what will be required to enable it to comply with HIPAA. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE representative for the most current information.
B-2 MUSE Revision A
2033425-029
Page 39
Appendix B – Summary of MUSE Security: Background Information

Background Information

Enter any description that helps clarify the security context. The security context would include product options,
Unknown
environmental conditions, intended Does the product Capture, Store, or Transmit any Patient identifiable data? Yes Identify the architecture that best describes this product: 3 tier
application What Operating System is this product Client based on? Windows XP What Operating System is this product based on (or in the case of client/server products -- what is the server)? WIN2003 Which GSP Platform does the product utilize? None Can the product display a customer supplied message on boot up or login? Yes & No,
the
application
cannot, but
Windows can
at login Does the product provide a training mode that allows for training without corrupting the operational data? No
Network Presence
Does this product have a communications/network interface (Not including Remote Service)? Yes Identify all of the Communications interface that this product has:
Ethernet Yes Token-Ring No ATM No RF (802.11, blue tooth, other radio) No COTS Modem Yes Other Modem (eg SDLC) No Direct Serial Yes Other No
Does this product have a Database? Yes, SQL
Server 2005 Identify all of the Services/Protocols the product provides:
Any Direct Network db Access (JDBC, ODBC, SQL, etc) Yes DICOM No HL7 Yes XML Yes Hill Top Yes Unity No AdvantageNET No PostScript or PCL printers Yes
Revision A MUSE B-3
2033425-029
Page 40
Appendix B – Summary of MUSE Security: Transactions, Code Sets, and Identifiers
SMTP or MAPI Yes FAX Yes SNMP Yes FTP Yes Telnet / X windows No Share (NFS, SMB, etc) Yes Customer Accessible API? Yes Other No None No
Identify the modes of Network Communications of Patient Identifiable Data that is supported using the above protocols:
Send Patient Identifiable Data to other systems Yes Receive Patient Identifiable Data from other systems Yes Provide a Query interface that other systems can use to extract Patient Identifiable Data Yes
Does this product have a Web Server? Yes
Transactions, Code Sets, and Identifiers
Identify all of the Code Sets this product sends or receives:
non-standard equivalents to X12N Transactions (Billing EDI transactions)? No standard X12N Transactions (Billing EDI transactions)? No non-standard equivalents to CDT code sets (Dental Services)? No standard CDT code sets (Dental Services)? No non-standard equivalents to CPT4 code sets (Physician services)? No standard CPT4 code sets (Physician services)? No non-standard equivalents to ICD9 code sets (Diseases, injuries, etc)? No standard ICD9 code sets (Diseases, injuries, etc)? No non-standard equivalents to NDC code sets (Drugs and Biotics)? No standard NDC code sets (Drugs and Biotics)? No non-standard equivalents to HCPCS code sets (other services)? No standard HCPCS code sets(other services)? No User (soft) configured codes that may be configured to include CDT, CPT4, ICD9, NDC, or HCPCS? Yes None of the above No
Identify all of the identifiers this product supports
“National Provider Identifier” (USA Unique identifier for all individuals providing healthcare services)? No “National Employer Identifier” (USA Unique identifier for all healthcare facilities)? No “National Payer Identifier" (USA Unique identifier for all insurance carrier)? No None of the above Yes
User Identification
B-4 MUSE Revision A
2033425-029
Page 41
Appendix B – Summary of MUSE Security: User Account Maintenance
Does the product provide for individual identification (accounts) of clinical users (excluding service users)? Yes What is the maximum number of accounts (0<zero> ==> theoretically infinite) 10,000 Does the product support passwords for authentication of the clinical users? Yes Does the product utilize the operating system authentication for clinical users? Yes Does the product place constraints on username? 16 char. max Identify all of the authentication technologies this product supports
Windows Domain Yes Microsoft Active Directory Yes Non-Windows Kerberos No NIS / YP No CCOW No Other No None No During login does the product inform the user of the last time the system was accessed using that user account? No Can the user authentication be augmented by a biometric, token, or other method besides passwords? Yes
Identify all of the advanced authentication the product supports:
tokens Yes smart cards Yes badge readers No written signature verification No one-time password generators No biometric identifiers No Certificate identification No dial-back modems No Other No None No
How does the customer get these advanced authentication methods? Customer
supplied
User Account Maintenance
Identify all of the information associated with a user account:
Full Name Yes Additional Identifier Yes Title Yes Department No Phone Number Yes E-mail Address Yes
Revision A MUSE B-5
2033425-029
Page 42
Appendix B – Summary of MUSE Security: Authorizations
Street Address No FAX Number Yes Other No None No
Who Can administer user accounts? Multiple
Accounts Identify all of the User Administrative controls supported
Audit Log of all account changes No Set an account inactive without removing the account? Yes Force a logoff of an active user? No Automatic de-activation of an account on a specified date or number of days/time? No Automatic de-activation of an account after a configured number of days of non-use? No Other No None No
Identify all of the User Account Reports supported:
List of all user accounts Yes List of currently active users Yes List of all user accounts with last used date/time No Other No None No When an account is marked inactive or deleted does the product disable in real-time any active sessions using that ID? Yes Does the product provide a tool for batch management of user accounts? Yes
Authorizations
Does the product support multiple levels of access control that can be assigned to user accounts? Yes Does the product support multiple levels of access control that can be assigned to groups of user accounts? Yes Identify all of the access control rights that can be applied to a user:
View Patient Identifiable Data on screen Yes Print Patient Identifiable Data to paper or film Yes Modify Patient Identifiable Data Yes Export Patient Identifiable Data to removable digital media No Delete Yes
Identify all the methods by which the access control right are applied:
Access at database view level No Access at file level No Access at file system directory level No Time-of-Day No
B-6 MUSE Revision A
2033425-029
Page 43
Appendix B – Summary of MUSE Security: Auto-Logoff
Weekly Schedule No Workstation (location) No Other Yes None No
Does product hide functionality that the user does not have rights to (to prevent the user from even knowing a functionality
Yes exists)?
Does the product further restrict access based on patient specific consent? No
Auto-Logoff
Identify all of the inactivity Auto Logoff capability supported:
Unprotected Screen Saver Yes Password protected Screen Saver (screen blanking) Yes Application Logout No Application blanking, with re-authentication allowing continuation. No Other No
None No Can the administrator override any inactivity screen/application blanking? Yes Identify how the inactivity timeout can be configured:
System Wide No
Workstation (location) Yes
Per-User Yes
Device to Device Authentication
Identify all of the entity authentication that is used, when communicating and the remote user is not or can not be authenticated serial number
Mac address No
IP Address No
AE-Title No
Process identifier No
Task identifier No
Unidirectional PKI certificate challenge (ex: simple SSL) No
Bidirectional PKI certificate challenge (ex: client and server auth SSL) No
Other No
None Yes
Log All Security Events
Identify all of the Security Events that can be logged:
Machine Shutdown Yes
Machine Boot Yes
Revision A MUSE B-7
2033425-029
Page 44
Appendix B – Summary of MUSE Security: Log All Patient Data Views
Application start Yes
Application stop Yes
Network link/connection failures Yes
Data Integrity failure No
Successful User Login Yes
Failed User Login Yes
User Logout Yes
Auto-Logoff Yes
Forced logoff by administrator No
A user changed their password Yes
An admin reset/cleared a users password Yes
Attempt by a user to access function/data that they do not have access to No
User/Group account creation Yes
User/Group account deletion Yes
User/Group Access rights modification No
Other No
None No Identify all of the contents of a Security Event log entry:
Date and Time Yes
Time to millisecond accuracy No
Identifier of the User Yes
Identifier of the device (workstation, IP, or other station identification) Yes
Event description Yes Are these security events tracked in a different log than patient identifiable data related events? Yes On failed authentication attempts, is the password attempted entered into the log? No Is the log file persistent (NOT automatically overwritten or deleted)? Not limited Is access to this log restricted to authorized individuals? Yes Can the customer specify the list of events to track? No
Log All Patient Data Views
Identify all of the Patient Identifiable Data View events that can be logged:
Printouts Yes
Export to files Yes
Export to removable media Yes
Faxed Yes
E-Mailed Yes
View by browser Yes
B-8 MUSE Revision A
2033425-029
Page 45
Appendix B – Summary of MUSE Security: Log All Patient Data Modifications
View by client application No
Retrieved over network protocol (DICOM, XML, API, etc) No
De-identification No
Other No
None No Identify all of the contents of a Patient Identifiable Data View log entry:
Date and Time Yes
Time to millisecond accuracy No
Identifier of User Yes
Identifier of Device (workstation, IP, or other station identification) Yes
Identifier of the application No
Identifier of the function within the application No
Identification of the Patient Yes
How long the data was displayed No
Event description Yes Is the log file persistent (NOT automatically overwritten or deleted)? not limited Is access to this log restricted to authorized individuals? Yes Can the customer specify the list of events to track? No
Log All Patient Data Modifications
Identify all of the Patient Identifiable Data Modification events that can be logged:
modification of clinical data prior to a final report (diagnosis, medications, observations, measurements, etc) Yes
modification or amendments to a final report Yes
modification of patient demographics Yes
modification of test date, time, or setup parameters Yes
modification of diagnosis Yes
None No Identify all of the contents of a Patient Identifiable Data Modification log entry
Date and Time Yes
Time to millisecond accuracy No
Identifier of User Yes
Identifier of Device (workstation, IP, or other station identification) Yes
Identifier of the application No
Identifier of the function within the application No
Identification of the Patient Yes
Event description Yes
Is the log file persistent (NOT automatically overwritten or deleted)? not limited
Revision A MUSE B-9
2033425-029
Page 46
Appendix B – Summary of MUSE Security: Log All Changes to the Configuration
Is access to this log restricted to authorized individuals? Yes
Can the customer specify the list of events to track? No
Log All Changes to the Configuration
Identify all of the Configuration Change events that can be logged:
Change of the system Date and/or Time No
Installation of patches, maintenance, FMI, hotfix, etc Yes
IP Address or other network configuration No
Analysis algorithm parameters No
Creation, modification, or deletion of output devices/API/interface/AE No
Creation, modification, or deletion of input devices/API/interface/AE No
Other No
None No Identify all of the contents of a Configuration Change log entry:
Date and Time Yes
Time to millisecond accuracy No
Identifier of User No
Identifier of Device (workstation, IP, or other station identification) No
Identifier of the application No
Identifier of the function within the application No
Event description Yes
Is the log file persistent (NOT automatically overwritten or deleted)? date limited
Is access to this log restricted to authorized individuals? Yes
Can the customer specify the list of events to track? No
Audit Log Viewing
Is there protection against ALL modification of all log files? Yes Is deletion of a log tracked in a different log? No Is viewing of a log tracked in a different log? No Does the product provide alerts based on automated advanced log analysis? No Are the audit trail alerts tracked in an log? No Is there a time synchronization function included and documented? Yes
Audit Log Mining
Does the product support the use of third-party audit mining packages? No Does the product support a mechanism for creating a text based audit log (or are the audit logs already text)? No Does the product integrate with CA Unicenter or HP Openview? No Does the product provide searching tools for the audit logs? No Does the product provide sorting tools for the audit logs? Yes
B-10 MUSE Revision A
2033425-029
Page 47
Appendix B – Summary of MUSE Security: Configuration Lockdown & Security Fixes
Identify all of the Audit Trail Reports that can be created:
Users accessing records with the same last name as the user No
Users accessing records with the same address as their address No
Access to records that have not been accessed in a long time No
Access to an employee’s own patient data No
Accesses to minor’s patient data No
Accesses to terminated employees patient identifiable data No
Multiple login attempts with improper authentication No
All users that have use a specific function No
All activity of a specific user No
All accesses to a specific patient No
All activity from a specific workstation or communications link No
All login and logout activity within a period of time No
All login failures No
All Access control failures No
All Modifications to security settings No
All changes to authentication settings No
All access via remote service interface No
All changes to the audit trails configuration No
Other No
None Yes
Configuration Lockdown & Security Fixes
Is this OS configured to meet DOD - C2 Compliance? No Have unnecessary services and protocols been turned off? Yes Have unnecessary services and protocols been uninstalled? Yes Are default passwords documented in any form of manual? Yes Are passwords that are not changeable used for administrative accounts? No Is the SNMP community name set to "public" or "private"? No Is there documentation available that describes the services and protocols that are necessary for proper operation of the
Yes
product? Is the customer free to apply any Operating System or tool vendor fixes to the product? No Does the M4 release contain all security fixes for the OS, database, or any other third party tools within 6 months of the
Yes
M4 date? For Operating Systems:
The typical time window between when a patch is available and when it can be applied to a customer system is 6
Yes
months
Revision A MUSE B-11
2033425-029
Page 48
Appendix B – Summary of MUSE Security: AntiVirus
The typical time window between when a patch is available and when it can be applied to a customer system is 12
months
The customer can get OS fixes that are no more than 12 months old Yes
Is this database configured with the minimal services and protocols running? Yes For Databases:
The typical time window between when a patch is available and when it can be applied to a customer system is 6
months
The typical time window between when a patch is available and when it can be applied to a customer system is 12
months
The customer can get database fixes that are no more than 12 months old Yes
Does the product include other third party tool or application (Backup software, SNMP agent, pcAnywhere,
maintenance tool, Microsoft Office, etc) For other 3rd party tools:
The typical time window between when a patch is available and when it can be applied to a customer system is
6 months
The typical time window between when a patch is available and when it can be applied to a customer system is
12 months
The customer can get 3rd party tool fixes that are no more than 12 months old Yes
Yes
Yes
Yes
Yes
Yes
Yes
List any Third Party Applications, Tools, Libraries, Drivers? Insite 2,
Antivirus software, Digiboard, IE, MSDE, MDAC, MMC, Disk
AntiVirus
Are all product releases and maintenance releases scanned for any malicious code (Virus, Worm, Trojan)? Yes Identify all of the Malicious Code detection supported:
Host based Intrusion Detection No
Norton AntiVirus Yes
McAfee AntiVirus Yes
Other Windows AntiVirus No
Customer supplied AntiVirus software No
Customer administrated AntiVirus Signature Files No
Tripwire or other No
None No
Integrity Controls on Data
Does the product utilize transparent end-to-end data integrity controls? (memory parity, tcp checksums, etc) Yes
B-12 MUSE Revision A
2033425-029
Page 49
Appendix B – Summary of MUSE Security: Backup and Recovery
Does the product enforce application managed data integrity controls like object checksums? No Does the product support PKI based Digital Signatures to maintain data integrity? No Does the product enforce required fields during data entry to ensure completeness of records? Yes Does the product have a data entry validation mechanism such as double keying of patient identifiable data to ensure
No
accuracy of the data entered? Does the product store rejected transactions with the reason for the rejection? Yes Does the product ensure that database updates are done in a fail-safe way? Yes Is there any Other form of integrity control provided? No
Backup and Recovery
How many patient records does this product store or manage? unlimited Identify all the ways that the product protects against disasters/failures:
Export to removable media No
RAID hard drive Yes
backup of patient data only (typically to tape) Yes
backup of full system (typically to tape) Yes
UPS Yes
Off site mirroring No
Near-line storage No
Other No
None No Backup and Recovery procedures are documented? Yes Can the Integrity and completeness of the backup be verified by the operator through the use of offline means? Yes
Encryption
Is any form of encryption of patient identifiable data supported (not including the service interface)? Yes
De-Identification
Is there a bulk de-identification functionality that the user can use? (not service interface) No
Digital Signatures
Does the product provide for some form of electronic acceptance stamp on Patient Identifiable Data? Yes Does the product provide for a PKI based digital signature? No Does the product support DICOM supplement 41 Digital Signature Extensions? No
Service
Is there a method that service can use to access the system in the case of an emergency when normal administration is
Yes
not possible? Does the product have at least one login specifically for servicing the equipment? Yes Does the product restrict service individuals with multiple levels of access control? No Does the product support multiple individual service accounts? Yes
Revision A MUSE B-13
2033425-029
Page 50
Appendix B – Summary of MUSE Security: Service
Are Service accounts restricted from viewing, or manipulating Patient Data? No Are all accesses to Patient Data by service restricted to de-identified data? No Are Service actions accounted for in a log file somewhere? Manually Are passwords that are not changeable used for Operating System administrative accounts? No Are passwords that are not changeable used for service accounts? No Are Service default passwords described in details in any form of manual? No Is the customer allowed to change the service passwords? Yes Does the product support remote service? Yes Does the remote service session require authentication to a service user? Yes Can the customer tell that a remote service session is in progress? Yes Can the customer, through automatic or manual methods, know which specific service individual is currently remotely
No
logged in? Can the customer see what is happening in an active remote service session? Yes Can the customer stop an active remote service session? Yes Specify the equivalent encryption strength that a remote service session can operate over? 3DES Is the product specific GE Remote Service network isolated from the rest of the GE intranet? No Are access points to the GE service network protected with an ICSA equivalent firewall? No Are remote sessions ever initiated without a Service call being logged by the customer? No
B-14 MUSE Revision A
2033425-029
Page 51
Appendix C – 21 CFR Part 11 Option:
C Appendix C – 21 CFR
Part 11 Option
Revision A MUSE C-1
2033425-029
Page 52
Appendix C – 21 CFR Part 11 Option: Electronic Signature
Electronic Signature
21 CFR Part 11 states that users must be prompted for a password on each site when they are not biometrically authenticated. The 21 CFR Part 11 option is available with MUSE software version 7.x software. When this option is enabled, the Site Information window contains two additional check boxes.
Enable 21 CFR Part 11
Display Password Prompt when saving
006
1. To enable 21 CFR Part 11, at System > Setup > Sites > Advanced, place a check mark in the box next to Enable 21 CFR Part 11.
C-2 MUSE Revision A
2033425-029
Page 53
Appendix C – 21 CFR Part 11 Option: Electronic Signature
2. If biometric authentication is being used for EVERY USER on the site, check the box next to Display Password Prompt when Saving.
3. If the site has some users who use biometric authentication and some users who do not use biometric authentication, check 21 CFR Part 11 and leave Display Password Prompt when Saving unchecked.
When Display Password Prompt when Saving is left unchecked in Site Setup, individual’s User Setups will be used by the system when they save reports.
The table below summarizes how the individual user’s Display Password Prompt when Saving option functions.
User Electronic Signature Summary
Site Setup Window User Setup Window
21 CFR Part 11 ;
Display Password Prompt when Saving
21 CFR Part 11 ;
Display Password Prompt when Saving
21 CFR Part 11 ;
Display Password Prompt when Saving ;
Display Password Prompt when Saving ;
Display Password Prompt when Saving
Display Password Prompt when Saving ;
-or-
Display Password Prompt when Saving
Prompt for Password on each
Save?
Yes, for that user at that site.
No
Yes, for all users at that site.
Revision A MUSE C-3
2033425-029
Page 54
Appendix C – 21 CFR Part 11 Option: Other 21 CFR Part 11 Features

Other 21 CFR Part 11 Features

Disable Automatic Updates to Report Data

When the 21 CFR Part 11 option is enabled, automatic updates to report data are disabled on the system. This means that confirmed reports are not updated when new reports for the same patient are confirmed. It also means that the system does not update data entered/acquired at the cart.
Patient demographic data (age, gender, race, height, and weight) are
not updated in confirmed data when new reports for the same patient are confirmed on the system.
After QTC has been calculated at the cart, the system does not re-
calculate QTC upon acquisition of this data.
When user IDs have been entered at the cart, the system does not
assign user names to these IDs upon acquisition of this data.
C-4 MUSE Revision A
2033425-029
Page 55
Page 56
gemedical.com
World Headquarters GE Medical Systems Information Technologies, Inc. 8200 West Tower Avenue Milwaukee, WI 53223 USA Tel: + 1 414 355 5000
1 800 558 5120 (US only)
Fax: + 1 414 355 3790
European Representative GE Medical Systems Information Technologies GmbH Munzinger Straße 3-5 D-79111 Freiburg Germany Tel: + 49 761 45 43 - 0 Fax: + 49 761 45 43 - 233
Asia Headquarters GE Medical Systems Information Technologies Asia; GE (China) Co., Ltd. 24th Floor, Shanghai MAXDO Center, 8 Xing Yi Road, Hong Qiao Development Zone Shanghai 200336, P.R. China Tel: + 86 21 5257 4650 Fax: + 86 21 5208 2008
Loading...