General Electric MARS UNIX TO PC CONVERSION INSTRUCTIONS_SM_2027879-040_B ELI 250c ÉLECTROCARDIOGRAPHE DE REPOS À 12 DÉRIVATIONS MANUEL D’UTILISATION

GEHealthcare
MARSAmbulatoryECGSystem
UNIXtoPCConversionInstructions
SoftwareVersion1.0 2027879-040RevisionB
MARSAmbulatoryECGSystem UNIXtoPCConversionInstructions English ©2010GeneralElectricCompany. AllRightsReserved.
PublicationInformation
TheinformationinthismanualappliesonlytoMARSAmbulatoryECGSystemVersion8.0.Itdoesnotapplytoearlierproductversions.Due tocontinuingproductinnovation,specicationsinthismanualaresubjecttochangewithoutnotice.
MARS,MUSE,andSambaSystemsaretrademarksownedbyGEMedicalSystemsInformationTechnologies,Inc.,aGeneralElectricCompany goingtomarketasGEHealthcare.Allothertrademarkscontainedhereinarethepropertyoftheirrespectiveowners.
Thedocumentpartnumberandrevisionappearatthebottomofeachpage.Therevisionidentiesthedocument’supdatelevel.The revisionhistoryofthisdocumentissummarizedinthetablebelow.
Revision
A
B
Date
12March2010Initialreleaseofthisdocument.
7June2010
Comment
ReviseSambaServiceschaptertoreectchangesfromSPR.
2
MARSAmbulatoryECGSystem
2027879-040B
7June2010
Contents
1Introduction
Conventions................................................................................................6
2Conversion
PlanningYourConversion...........................................................................7
ConversionWorkow..................................................................................7
3SambaServices
StoppingtheSambaDaemon.....................................................................9
SharingFoldersontheMARSUNIXSystem...............................................10
TypographicalConventions.........................................................................6
SafetyConventions...................................................................................6
IPAddressofUNIXMachineonenterpriseNetwork.................................11
4RestoringArchiveDatatoUNIXWorkstation
RestoringtheData....................................................................................13
EjectingtheTape.......................................................................................14
CopyingtheRestoredDatatoaNetworkDrive........................................14
5MARSUNIXMigrationTool
InstallingMARSUNIXMigrationTool........................................................15
6ConvertingData
UnderstandingConvertandArchive.........................................................17
ConvertandArchive(Recommended).......................................................18
ConvertOnly.............................................................................................19
ArchiveOnly..............................................................................................20
Viewing/SavingtheLog.............................................................................20
7TheConversionLog
2027879-040B
MARSAmbulatoryECGSystem
3
ReadingtheConversionLog.....................................................................21
8CheckoutProcedure
CheckingtheConversionontheMARSPC................................................23
AVIEditor
StartingtheVIEditor.................................................................................25
ExitingVI...................................................................................................25
VICommands............................................................................................25
BUsageInstructionsUsingCommandLines
UNIXtoPCCommandLine........................................................................27
ListingMARSUNIXSlot/ReportFile(s).......................................................28
ConvertingMARSUNIXSlot/ReportFile(s).................................................28
ArchivingConvertedMARSUNIXSlot/ReportFile(s)..................................28
ConvertingandArchivingMARSUNIXSlot/ReportFile(s)..........................29
ViewingtheLog.........................................................................................29
SavingtheLog...........................................................................................29
4
MARSAmbulatoryECGSystem
2027879-040B
1

Introduction

TheMARSUNIXPCMigrationToolconvertsMARSUNIXslotandreportlesforuseby MARSPCversion8.0.Tousethetool,youmustrstrestorearchivedlestotheMARS UNIXsystemfromthetapearchive.Thetoolcannotdirectlyconvertlesfromtape.
Thetoolsupportsthreeworkows:
Workow
ConvertOnly
ArchiveOnly
ConvertandArchive
Toconvertslotandreportles,youmustrestorethemonthecustomer’sexisting MARS3000,MARS5000,MARS8000system,runningMARSUNIXversion4.1.
YoucanruntheconversiontoolonasystemwithorwithoutMARSPCinstalled. SupportedOperatingSystemsforthetoolincludeWindows2003Server ,Windows 2000,andWindowsXP.BecausethetoolisWindows-based,youmustsetupSamba ServicesontheMARSUNIXsystem.ThisallowstheWindowssystemtoaccessthe MARSdirectory,wheretherestoredlesreside.
NOTE:
SambaallowsnetworksharesforchosenUNIXdirectoriestoappeartoMicrosoft WindowsasnormalWindowsfoldersaccessibleviathenetwork.
Instructionsincludeacheckoutproceduretoverifythattheconversionwassuccessful.
Youmayconvertthefollowingletypes:
FileExtension
.rpt
.nat
.nrt
Description
ConvertUNIXslot/reportles.Youcansaveandarchive theconvertedlesatalaterdate.
ArchivealreadyconvertedUNIXslot/reportles.
Archiveslot/reportlesimmediatelyafterconversion.
DataType
Reports
Holter(SEER,TAPE,monitoring)
Monitoring
Theinstructionsprovidedinthisdocumentassumeyouarerunningthetoolusingits userinterface.Youcanalsorunthetoolusingcommandlines.Theinstructionsfor usingcommandlinesareinAppendixB.
2027879-040B
MARSAmbulatoryECGSystem
5
Introduction

Conventions

Thefollowingconventionsareusedinthismanual.

TypographicalConventions

StyleDenition
BoldTextIndicateskeysonthekeyboard,texttoenter,orhardwareitemssuch
Italicized-BoldTextIndicatessoftwaretermsthatidentifymenuitems,buttonsoroptions
Ctrl+EscIndicatesakeyboardoperation.A(+)signbetweenthenamesof
<Space>
Enter
asbuttonsorswitchesontheequipment.
invariouswindows.
twokeysindicatesyoupressandholdtherstkeywhilepressing thesecondkeyonce.
Forexample,“PressCtrl+Esc”meanstopressandholddowntheCtrl keywhilepressingtheEsckey.
Indicatesthatyoumustpressthespacebar. Wheninstructionsaregivenfortypingaprecisetextstringwithone
ormorespaces,thepointwherethespacebarmustbepressedis indicatedas:<Space>.Thepurposeofthe<>bracketsistoensure youpressthespacebarwhenrequired.
Indicatesthatyoumustpressthe“Enter”or“Return”keyonthe keyboard.Donottype“Enter”.

SafetyConventions

ThetermsDANGER,WARNING,andCAUTIONareusedthroughoutthismanualtopoint outhazards,andtodesignateadegreeorlevelofseriousness.Familiarizeyourself withtheirdenitionsandsignicance.
Safety Convention
HazardAsourceofpotentialinjurytoaperson.
DANGER
WARNING
CAUTION
NOTE
Denition
Indicatesanimminenthazardwhich,ifnotavoided,willresultindeath orseriousinjury.
Indicatesapotentialhazardorunsafepracticewhich,ifnotavoided, couldresultindeathorseriousinjury.
Indicatesapotentialhazardorunsafepracticewhich,ifnotavoided, couldresultinminorpersonalinjuryorproduct/propertydamage.
Providesapplicationtipsorotherusefulinformationtoassurethatyou getthemostfromyourequipment.
Additionalsafetymessagesthatprovideappropriatesafeoperationinformationmay befoundthroughoutthismanual.
6
MARSAmbulatoryECGSystem
2027879-040B

Conversion

PlanningYourConversion

RestoringtherawslotlesfromthetapearchivetotheMARSUNIXsystemcantake uptothreeminutesperle.Thisisduetothesizeoftheslotleanddatatransferrate ofthetapedrive.Pleaseconsiderthetimeinvolvedwhenplanningyourconversion. Forexample,asingletapearchiving50slotlescouldtakeaslongas2.5hoursto restore.OncerestoredontheMARSUNIXsystem,theconversionprocessitselfruns quickly,takingonly15-30secondstoconverteachslotle.
Toshortenthetimeneeded,youmaywanttoconsiderconvertingonlyreportles. Theselesaremuchsmallerandtakemuchlesstimetorestore,andonlyafew secondstoconvert.
Whenplanningyourconversion,rememberthatyoumusthave:
2
AworkingMARSUNIXsystem.
AnoperatingDATTapedriveavailable.
Makesurethatalldataconversionsarecompletedbeforeremovingthesystemfrom thenetworkorretiringthesystemfromservice.
ConversionWorkow
Followingisthegeneralconversionworkow:
1.Ifyouareconvertingtherawholterdata,deletepatientsontheUNIXsystemto openasmanyslotsaspossible.
2.RestorethearchivedatafromDATtotheUNIXworkstation.
3.Chooseoneofthefollowingoptions:
RuntheconversiondirectlyontherestoredslotlesontheUNIXsystem.
Copytherestoredslotlestoanetworkshareandconvertthelesfromthere.
NOTE:
4.RuntheUNIXtoPCConversionToolonaWindows-basedsystem
Thesecondoptionallowsyoutorestoreslotleswithouttheneedto immediatelyconvertthem.
2027879-040B
MARSAmbulatoryECGSystem
7
Conversion
5.SelectConvertorArchive.
ConvertsavestheconvertedlesintheMARSPCslotleformat(thatis,
seerslot1s20.nat)
ArchivesavestheconvertedlesintheMARSPCarchiveformat(thatis,
archive.nat)
6.Setthesourcelelocation.
Thisiswheretherestoredslotlesarelocated.
7.Setthedestinationlelocation.
Thisiswhereyouaresavingtheconvertedles.
8.Selectthelesorreportsyouwanttoconvert.
9.Runtheconversion.
10.Repeatthesestepsasrequired.
8
MARSAmbulatoryECGSystem
2027879-040B

SambaServices

ThischapterdescribeshowtosetuptheSambaservicestodisplayUNIXfolders onaPC.

StoppingtheSambaDaemon

ThefollowingstepsdescribehowtostoptheSambadaemon.
1.FromtheMARSapplication,holdthemiddlemousebutton,andclickanddrag anysystemiconontothesystemmenuheader,locatedintheupper-leftcorner ofthescreen.
AcmdtoolwindowopensandtheMARSxx-yyyycommandpromptisdisplayed.
2.Attheprompt,typesuroot.
3.Atthenextprompt,enterthepasswordfortherootuser.
3
Thisgivesyourootaccountpermissions.
NOTE:
Ifyoudonotknowthepassword,contactGEHealthcareTechnicalSupport.
4.CheckifSambaisrunning:
a.Attheprompt,typeps[space]—eandpressEnter.
b.Reviewthelistandidentifyifthesmbdprocessispresent.
Ifitispresent,makenoteoftheProcessID(PID)andcontinuetostep5.
Ifsmbdisnotdisplayedinthelist,itisnotrunning.Skipstep5andgoto
“SharingFoldersontheMARSUNIXSystem”onpage10.
5.KilltheSambaprocess:
a.Atthepasswordprompt,enterthepasswordfortherootuser.
NOTE:
Ifyoudonotknowthepassword,contactGEHealthcareTechnical Support.
b.Typekill<PID>andpressEnter.
Where<PID>istheprocessnumberassociatedwiththesmbdprocess.
2027879-040B
MARSAmbulatoryECGSystem
9
SambaServices

SharingFoldersontheMARSUNIXSystem

UsethecommandsinthissectiontosharefoldersontheMARSUNIXsystem.
1.Openthesmb.conflefromthecmdtoolusingVIEditororfromtheCommon DesktopEnvironment(CDE)usingtheTextEditor.
UsingtheVIEditor:
1.Openacmdtoolwindowandlogonasrootuser.
2.Typevi[space]/etc/smb.conf.
Thesmb.confleopensintheeditor.
NOTE:
IfyouareunfamiliarwiththeVIEditor,refertoAppendixA“VIEditor”
onpage25.
UsingtheTextEditor
1.LogontoMARSasarootuser.
TheCDEisdisplayed.
2.ClickontheTextEditoricon.
TheTextEditorwindowopens.
3.Browsetothe/etcfolderandopenthesmb.confle.
2.Addthefollowingentriestothesmb.confles:
[slots] comment=UNIXslotfiles path=/slots public=yes writeable=yes createmask=UNIXpermissions
3.Saveyourchanges.
IfyouareusingtheVIEditor,type:wqtosaveyourchangesandexittheeditor .
IfyouareusingtheTextEditor,selectSavefromthelemenu.
4.Fromacmdtoolwindow,makesureyouareloggedonasrootuserandtype exec[space]/opt/MarsSamba/bin/smbd.ThisstartstheSambadaemon.
5.Typeps[space]—eandcheckthatthesmbdprocessislisted.
NOTE:
Ifyouarehavingaproblemgettingtheprocesstostart,youmayneedto doaSystemShutdownandboot.
10
MARSAmbulatoryECGSystem
2027879-040B

IPAddressofUNIXMachineonenterprise Network

TheIPaddressoftheUNIXmachineisneededlatertogainaccesstothefolder sharesonthenetwork.
1.FromtheMARSapplication,holdthemiddlemousebutton,andclickanddrag anysystemiconontothesystemmenuheader,locatedintheupper-leftcorner ofthescreen.
AcommandtoolwindowopensandtheMARSxx-yyyycommandpromptis displayed.
2.IdentifytheIPaddresstotheEnterpriseNetwork:
a.Attheprompt,typesuroot.Thischangestheuseraccountforthe
commandlinetooltotherootuser.
b.Atthepasswordprompt,enterthepasswordfortherootuser.
NOTE:
Ifyoudonotknowthepassword,contactGEHealthcareTechnical Support.
SambaServices
c.Atthecommandlineprompt,typeifcong[space]—aandpressEnter.
AlistofIPaddressesisdisplayed.
d.MakenoteoftheIPaddressconnectedtotheEnterpriseNetwork.
NOTE:
MARSUNIXsystemsconnectedtothemonitoringreal-timenetwork havemorethanonenetworkcard.TheaddressfortheEnterprise NetworktypicallyisidentiedasthehighesthmeXnumberinthelist. Forexample,ifbothhme1andhme2arelisted,hme2isnormallythe IPaddressfortheEnterpriseNetwork.
2027879-040B
MARSAmbulatoryECGSystem
11
SambaServices
12
MARSAmbulatoryECGSystem
2027879-040B

RestoringArchiveDatatoUNIX Workstation

YouneedalloftheslotlesontheMARSworkstationopentorestoreasmanyslot lesaspossible.Toopenslotles,youneedtodeletepatients,asdescribedinthe MARSOperator’sManual.
YoumaywanttoconvertexistingslotlesandreportsontheMARSUNIXworkstation astherststepoftheconversionprocessbeforedeletingthem.Ifyoupreferto archivethecurrentdataandconvertitlater ,copyittoDATTape,asdescribedinthe Operator’sManual,“StoringDATAtoTAPE”intheMARSUser’sManual.

RestoringtheData

1.InserttheDATtapeintheDATtapedrive.
4
Pushthetapeintothedriveuntilthedrivedrawsitin.Whenready,theDAT driveactivitylightglowsgreen.
2.SelectthePatientSelectmenuicon.
3.ClickDATintheDataTypelistbox.
4.Selectthepatientorpatientsyouwanttorestore.
5.ClickTools.
6.ClickRestorefromDAT.
Thefollowingmessageisdisplayed:YouhaveselectedXle(s)forDATrestore.
Areyousureyouwanttorestoretheselectedle(s)?
7.ClickYestorestoreasinglepatient,orclickYestoALLtorestoremorethan onepatient.
TheDATactivitylightblinksforafewsecondsandthefollowingmessageis displayed:Xle(s)queuedforDATrestore.
8.ClickOK.
Theworkstationrestoreslestothefollowingdatatypes:
2027879-040B
MARSAmbulatoryECGSystem
13
RestoringArchiveDatatoUNIXWorkstation

EjectingtheTape

1.Checkthattheactivitylightisnotglowing.
2.PressEject.
3.Thetapecartridgeejects.
4.Removethetapedrive.
Repeatthisprocedureforeachsetofslotlesyouarerecovering.
Files
Tape,SEER,orMonitoringHolterHolter
DischargedMonitoringPatientFiles
Report
Thestatusoftheselectedle(s)changesfromQueuedforAcqto%Acquired andnallytoReadytoEdit.
NOTE:
PressingEjectwhiletheActivitylightisblinkingmayinterruptatapeaccess command.
TheActivitylightashesforabout30seconds
DataTypes
Monitoring
Storedreports

CopyingtheRestoredDatatoaNetworkDrive

IfyouareconvertingthedatafromanetworkdriveinsteadoftheMARSUNIX workstation,
1.Accessthe\slotsor\reportsfoldersharesyousetupinChapter3“Samba
Services”onpage9.
2.Copythefolderstothenetworkdriveyouareusing.
14
MARSAmbulatoryECGSystem
2027879-040B

MARSUNIXMigrationTool

InstallingMARSUNIXMigrationTool

NOTE:
CustomerswhodonothaveaninstallationCDavailablecanaccesstheUNIXto PCDataConversiontooldirectlyfromaMARSv8Workstation.UseWindows
Explorerandbrowsetoc:gemsit\opt\MarsNT\bin.Double-clickUIUnix2PC.exe tolaunchthetool.
1.InserttheUNIXtoPCDataConversionToolCDintothePCwhereyouare installingthetool.
2.NavigatetotheCD-ROMdriveranddouble-clickSetup.exeinstaller.
3.SelectNextattheWelcomescreen.
4.SelecttheIacceptthetermsofthelicenseagreementcheckboxandclickNext.
5
5.AttheChooseDestinationLocationdialogbox,dooneofthefollowing:
Toacceptthedefaultinstallationpath,clickNext.
Tochangetheinstallationpath,clickChange,browsetothelocationwhere
youwanttoinstallthetool,andclickNext.
2027879-040B
MARSAmbulatoryECGSystem
15
MARSUNIXMigrationTool
6.AttheReadytoInstalltheProgramdialogbox,selectInstall.
7.ClickFinishwhenpromptedtocompletetheinstallation.
16
MARSAmbulatoryECGSystem
2027879-040B

ConvertingData

YouhavethefollowingoptionswhenusingtheMARSUNIXtoPCConversionTool:
ConvertandarchiveMARSUNIXslot/reportle(s)
ConvertMARSUNIXslot/reportles
ArchiveconvertedMARSUNIXslot/reportle(s)
6
Therecommendedoption,thisconvertstheexistingMARSUNIXslot/report lesandarchivesitintheMARSPCformat.Thisoptionsavestimeandavoids confusionlateintheprocessandisdiscussedinthesection“ConvertandArchive
(Recommended)”onpage18.
ThisoptionconvertstheexsitingMARSUNIXslot/reportlesintotheMARSPC slot/reportleformat.
ThisoptionarchivesMARSUNIXslot/reportlesthatwerepreviouslyconvertedinto theMARSPCarchiveformat.

UnderstandingConvertandArchive

Theconversiontoolsavestheconvertedlesusingthestandardslotlenaming convention.Toavoidgeneratingalargenumberofconvertedlesintoasinglefolder , GEHealthcarerecommendsyoucreateafolderstructurefortheconvertedlesso thatitaidsinidentifyingthelesinit.Forexample,ifyoualreadyhaveanaming schemeforthetapes,youmaywanttousesomethingsimilarasafolderstructure fortheconverteddata.
Whendataisconvertedtothearchivestate,anindex.datleiscreatedinthefolder andupdatedeachtimenewlesareadded.Theindex.datprovidesinformationtothe MARSPCthatidentiestheslotorreportletothesystemtorestoreitifneeded.Ifthe destinationfolderischanged,anewindex.datleiscreated.Youcannotcombine archivedleslateronfromtwodifferentfolderssincetheindex.datleisindexing onlythearchivelesforonefolder .
Eachtimeyouruntheconversiontool,itaddstheconvertedorarchivedlestothe destinationfolder .Iftherearepreviouslyarchivedorconvertedles,newlesare createdusingthenextnumericalsequence.Forexample,ifthelastarchivedfolderis
2027879-040B
MARSAmbulatoryECGSystem
17
ConvertingData
archive5.nat,thenextlecreatedisarchive6.nat.Ifthedestinationfolderischanged, thenumbersequencestartsoverat0.
NOTE:

ConvertandArchive(Recommended)

Toconvertandarchivedatainasinglestep,usethefollowingprocedure:
1.LaunchtheUIUNIXtoPCDataConversiontool.
2.ClickChangeundersourcefolderframeorselectFile->Open.Thisopensthe
3.Ifconvertingdatadirectlyfromthe\slotsor\reportsfolderontheMARSUNIX
IfyouconvertaMARSUNIXslotlethatcontainsSiteandLocationinformation, thatinformationwillnotbeconvertedtotheMARSPCleunlesstheSiteand LocationalreadyexistontheMARSPCsystem.Therefore,beforebeginningthe conversion,youmaywanttoverifythatallSitesandLocationslistedontheMARS UNIXsystemexistintheMARSPCsystem.
FileOpendialogbox.
workstation,givetheIPaddressoftheUNIXmachineprecededby\\intheFile Nametextbox.Thatis:\\192.43.12.3.
NOTE:
Youcanalsouseamappeddrive,providedyoualreadymappedittothe MARSUNIXmachine.
Ifyoucopiedtherestoredslotlesorreportstoanetworkshare,providethe
UNCpathtotheshare,\\<computername>\<foldershare>.
Ifyoucopiedtherestoredlestothesystemrunningtheconversiontool,you
needtoprovidethepathtothefolder .
4.Ifthefoldershareisrestricted,youmaybepromptedforaUsernameand Password.
ForaMARSUNIXworkstation,thesemaybetheUsernameandPasswordfor theMARSUNIXmachine.
5.Thetooldisplaysalltheslotlesandreportsavailableintheselectedfolder.
6.SelecttheUNIXslotsorreportlestoarchive.
7.ClickOpen.
8.Selectthedestinationfolderfortheconvertedslot/reportle(s).
9.ClickArchive.
Thetooldisplaysaprogressionbarfortheconversionoperationasitconverts theUNIXslot/reportle(s)toPCslot/reportle(s)andthenarchivesthe convertedslot/reportle(s)tothespecieddestinationfolder,driveorCD.
18
MARSAmbulatoryECGSystem
2027879-040B
ConvertingData

ConvertOnly

ToconvertlesonlyandsavetheminthenativeMARSPCslotorreportleformat, usethefollowingprocedure:
1.LaunchtheUIUNIXtoPCDataConversiontool.
2.ClickChangeundersourcefolderframeorselectFile->Open.Thisopensthe FileOpendialogbox.
3.Ifconvertingdatadirectlyfromthe\slotsor\reportsfolderontheMARSUNIX workstation,givetheIPaddressoftheUNIXmachineprecededby\\intheFile Nametextbox.Thatis:\\192.43.12.3.
NOTE:
Youcanalsouseamappeddrive,providedyoualreadymappedittothe MARSUNIXmachine.
Ifyoucopiedtherestoredslotlesorreportstoanetworkshare,providethe
UNCpathtotheshare,\\<computername>\<foldershare>.
Ifyoucopiedtherestoredlestothesystemrunningtheconversiontool,you
needtoprovidethepathtothefolder .
4.Ifthefoldershareisrestricted,youmaybepromptedforaUsernameand Password.
ForaMARSUNIXworkstation,thesemaybetheUsernameandPasswordfor theMARSUNIXmachine.
5.Thetooldisplaysalltheslotlesandreportsavailableintheselectedfolder.
6.SelecttheUNIXslotsorreportlesforconversion.
7.ClickOpen.
2027879-040B
MARSAmbulatoryECGSystem
19
ConvertingData

ArchiveOnly

8.Selectthedestinationfolderfortheconvertedslot/reportle(s).
9.ClickConvert.
Thetooldisplaysaprogressionbarfortheconversionoperationasitconverts theslot/reportle(s)andputstheconvertedlesinthespecieddestination folder.
YoucanperformtheArchiveOnlyprocedureonlesthatwerepreviouslyconverted. Toarchivepreviouslyconvertedles,usethefollowingprocedure:
1.InvoketheUIUNIXtoPCDataConversiontool.
2.Selecttheconvertedslot/reportle(s)intheFile->Opendialogbox.
3.ClickOpen.
4.Selectthedestinationfolderforthearchivedslot/reportles.
5.ClickArchive.
Thetooldisplaysaprogressionbarshowingthearchivalprogressasitarchives theslot/reportle(s)tothespecieddestinationfolder.

Viewing/SavingtheLog

Thesystemcreatesanewlogleeachtimethetoolislaunched.Theloglecontinues toappendentriesaslongasitremainsopen.Oncethetoolisclosed,thelogleis deleted.Ifyouwanttokeeparecordoftheconversion,savetheloglebeforeclosing thetool.
1.Duringconversionorarchiving,clickDetails.
Thetoolexpandsdownwardanddisplaysthestatusloginaneditbox.
Thetoolalsodisplaysthenumberoflesselected,thenumberoflesprocessed, thenumberoflesremainingtoprocess,andthenumberoflesfailedin process.
2.SelectFile->SaveLog.
ASavedialogboxopenswithadefaultname<LogleName-Date-Time>.login intheFileNametextbox.(Forexample:Log13-May-08-10-44-48.login).
NOTE:
Thelenameanddatearetheactualname,date,andtimeofsaving.
3.ClickSavetosavethelogle.
20
MARSAmbulatoryECGSystem
2027879-040B

TheConversionLog

ReadingtheConversionLog

Aftercompletingtheconversion,checkthelogleordisplayfordetailsonthe conversion/archivalprocess.Theendofthelogdisplaysthesummary:
Totalxle(s). SuccessfulConversionxle(s). FailedConversion0le(s).
Basedonthisyougetanoverviewoftheconversion’ssuccess.Fordetails,lookatthe logforeachconversion.Eachleshouldlooksomethinglikethis:
Copyingfrom\\3.36.24.203\reports\report12.rpttoD:\DOCUME~2\romits\ LOCALS~1\Temp\\report12.rpt...Done ConvertingfromD:\DOCUME~2\romits\LOCALS~1\Temp\\report12.rptto D:\DOCUME~2\romits\LOCALS~1\Temp\\pcreport.rpt...Done MovingfromD:\DOCUME~2\romits\LOCALS~1\Temp\\pcreport.rptto C:\gemsit\unix2pc\NewFolder\report0.rpt...Done
7
Ifthereanyerrors,theyareloggedforeachle.Thefollowingtabledisplayssomeof thecommonerrorsyoumayndinthelog:
Error
SelectedleisotherthanMARSlesInvalidMARSdatale
SelectedslotleiscorruptedFilemaybeemptyorcorrupted
Diskspaceisnotavailableinthedestination folder
SelectedleisalreadyconvertedtoPC format
2027879-040B
MARSAmbulatoryECGSystem
LogReads:
Insufcientdiskspace
AlreadyConverted
21
TheConversionLog
22
MARSAmbulatoryECGSystem
2027879-040B

CheckoutProcedure

Thissectiondescribestheproceduretofollowifyouwanttochecktheconversion aftertheConvertonlyworkow.(Incaseyoudonotwanttochecktheconversion immediately,youcanfollowtheConvertandArchiveworkowandlaterrestorefrom thearchivetoMARSandchecktheles.)

CheckingtheConversionontheMARSPC

1.ClosetheMARSapplicationifitisrunning.
2.StopallMARSservicesfromtheservicecontrolpanel.
3.Converttheslotlesand/orreportlestoPCformatusingeitherthecommand lineorgraphicaluserinterface.YoucandothisoneithertheMARSPCorona separateconversionsystem.
Itishighlyrecommendedthatyouconvertslotstoadestinationfolder(other
thangemsit\slots).Thoughtheconvertedslotsarenotimmediatelyviewable inMARS,ithelpsavoidalotofconfusion.
8
Theinstructionsforusingthetooltoconvertslotlesarein“ConvertingData”
onpage17.
4.Checktheconversionlogforsuccessfulconversionandforanyerrors.
5.Savethelogle.See“TheConversionLog”onpage21formoredetailsonthis.
6.Renametheexisting\gemsit\slotsfolderto\gemsit\slots_backupandthe \gemsit\reportsfolderto\gemsit\reports_backup.
7.Createanother\gemsit\slotsfolderanda\gemsit\reportsfolder .
8.Copytheconvertedslotandreportlestotheirrespectivefoldersundergemsit.
9.StartalltheMARSservicesfromthecontrolpanel.
10.LaunchtheMARSapplication.
11.Gotopatientselectandcheckifalltheconvertedslots/reportsarepresent.
2027879-040B
MARSAmbulatoryECGSystem
23
CheckoutProcedure
12.Foreachconvertedslot,selectitandrunthroughPatientinformation,Patient diary,Stripreview,Pagereview,Eventreview,ShapereviewandEpisode reviewtocheckiftheslotisviewable.
NOTE:
WhenMARSPCwasintroduced,theDetectHorizontalorDownsloping OnlyeldwasaddedtoeventdenitionsforSTsegments.Ifthiseldis
checkedontheMARSPC,slotlesthatareconvertedfromMARSUNIX willerroneouslydisplayanSTDepressionvalueof0.Toresolvethis, cleartheDetectHorizontalorDownslopingOnlyeldonthePatient: EventDenitionsSettingsandAnalysisResultswindow.ThecorrectST Depressionvalueshouldthenbedisplayed.
13.Foreachconvertedreport,clickonReportreviewtocheckifthereportis viewable.
14.Afterverifyingthattheleswereconverted,doarollbacktoreturnthesystemto itsformerstate.
a.CloseMARS.
b.StopallMARSservices.
c.Deletetheslotsandreportsfolderingemsit.
d.Renamethe\gemsit\slots_backupto\gemsit\slots.
e.Renamethe\gemsit\reports_backupto\gemsit\reports.
f.RestartMARSservices.
24
MARSAmbulatoryECGSystem
2027879-040B
VIEditor

StartingtheVIEditor

Thecommandtostarttheeditorisvi,followedbylename.Forexample,toeditale calledtemporary,typevitemporaryandthenpressreturn.

ExitingVI

ToexitVI:
1.PressEscandthentype:q.
2.Type:wtosavecontentsoftheeditor .
3.Type:wqtosaveandexitfromtheeditor.
A

VICommands

Command
hMovesthecursortotheleftonecharacterposition
I
j
kMovesthecursoruponeline
lMovesthecursortotherightonecharacterposition r
u
x
ddDeletesthewholeline
2027879-040B
Action
Entersinsertmode;thecharacterstypedinareinsertedbeforethecurrent cursorposition.Ifyouspecifyacount,allthetextthatwasinsertedis repeatedthatmanytimes.
Movesthecursordownoneline
Replacesonecharacterunderthecursor;specifythecounttoreplacea numberofcharacters
Undoesthelastchangetothele;typinguagainwillre-dothechange.
Deletesthecharacterunderthecursor;thecountspecieshowmany characterstodelete;thecharactersaredeletedafterthecursor .
MARSAmbulatoryECGSystem
25
VIEditor
26
MARSAmbulatoryECGSystem
2027879-040B
UsageInstructionsUsingCommand Lines

UNIXtoPCCommandLine

YoucanrunallavailablefunctionsintheUserInterfaceforthetoolfromaCommand Line.ItisrecommendedthatcustomersusetheUserInterfaceprovidedwiththe tooltoavoidconfusionandreducetheriskoferrors.Thefollowingparametersfor commandlineusageisforGEHealthcareServicepersonnel.
<>
B
Usage
Requiredparameters
[]
cmdunix2pc[<-src:Source-Path><-usr:Username><-pwd:Password>|<-src:Map­Drive>][<-ls>|[<-conv>|<-arc>[-dst:<Destination-Path>][-log][-s:[Saveas Location]
Parameters
-src:Source-PathPathtoremoteUNIXsystem.
-src:Map-Drive
-usr:Username
-pwd:PasswordPasswordoftheUNIXsystem.
-dst:Destination-PathPathtostoreconvertedMARSdatales.
-lsListsallMARSdatales.
-conv
-arc
-logDisplaysthelogincommandlinewindow.
-s
-s:SaveasLocation
NOTE:
Use*.natforslotlesand*.rptforreportles.
Optionalparameters
Description
Mapsthedriveofaremotesystem.
UsernameoftheUNIXsystem.
Flagforconversion.
Flagforarchiving.
Saveslogleatcurrentlocation.
Saveslogleatthespeciedpath.
2027879-040B
MARSAmbulatoryECGSystem
27
UsageInstructionsUsingCommandLines

ListingMARSUNIXSlot/ReportFile(s)

1.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis installed.
2.RuntheCMDUnix2PC.exewiththe-lsoptionalongwith–src,-usr,-pwdoptions.
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots–usr:mei–pwd:mei–ls
Thiscommandlistsalltheslotandreportlesundertheslotsfolder.

ConvertingMARSUNIXSlot/ReportFile(s)

1.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis installed.
2.RuntheCMDUnix2PC.exewiththe-convoption:
Forexample:
CMDUnix2PC.exe-src:\\3.36.24.203\slots\seerslot3.s24.nat–usr:mei –pwd:mei–conv–log–dst:<destinationpath>
Thisconvertstheslotleandputsitinthedestinationfolder.
3.Forconvertingmultipleslotles,givethefollowingcommand:
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots\*.nat–usr:mei–pwd:mei–conv –log–dst:<destinationpath>
Thisconvertsallslotlesintheslotsfolderandputstheminthespecied destinationfolder .
NOTE:
Theconvertedslotlename(s)arethenextavailablesequencenumberfor thesameslottypeinthespecieddestinationfolder.

ArchivingConvertedMARSUNIXSlot/Report File(s)

1.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis installed.
2.RuntheCMDUnix2PC.exewiththe-arcoptionandthearchivelocationinthe –dstoption.The–srclocationpointstoalocalfolderwhereconvertedslotsare present.Usethe*.*optionforarchivingbothreportsandslots.
28
MARSAmbulatoryECGSystem
2027879-040B
UsageInstructionsUsingCommandLines

ConvertingandArchivingMARSUNIXSlot/Report File(s)

Forexample:CMDUnix2PC.exe–src:<Convertedslotspath>\*.*-arc–log–dst:<archive path>
1.Thisarchivesalltheslotlespresentin<Convertedslotsfolder>.
2.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis installed.
3.RuntheCMDUnix2PC.exewiththe-arcoptionandthearchivelocationinthe –dstoption.The–srclocationpointstotheUNIXfolderwheretheslots/reports arepresent.
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots\*.nat–usr:mei–pwd:mei–arc–log –dst:<archivepath>
Thisconvertstheslotle(s)fromUNIXformattoPCformatandthenarchives theconvertedslotle(s)inthespeciedarchivefolder.

ViewingtheLog

1.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis
2.RuntheCMDUnix2PC.exewiththe-logoption.

SavingtheLog

1.OpenacommandlinewindowandgotothedrivewheretheUnix2PCtoolis
2.RuntheCMDUnix2PC.exewiththeoption-logoptionand-soption.
installed.
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots\seerslot2.s48.nat–usr:mei –pwd:mei–conv–log-dst:c:\gemsit\slots
Thisdisplaysthestatuslog,thetotalnumberoflesselected,thetotalnumber oflesconvertedsuccessfully,andthenumberoflesthatfailed.
installed
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots\seerslot2.s48.nat–usr:mei –pwd:mei–conv–log-dst:c:\gemsit\slots–s
Thissavestheloglewiththelename Unix2pc<dd>-<mmm>-<yy>-<hour>-<min>-<sec>.log(timestamp)inthe currentlocation.
3.Tosavethelogletoaspeciedlocation,usetheoption-s:<folderpath>.
Forexample:
CMDUnix2PC.exe–src:\\3.36.24.203\slots\seerslot2.s48.nat–usr:mei –pwd:mei–conv–log-dst:c:\gemsit\slots–s:d:\log
2027879-040B
MARSAmbulatoryECGSystem
29
UsageInstructionsUsingCommandLines
30
MARSAmbulatoryECGSystem
2027879-040B
GEMedicalSystems
InformationTechnologies
8200WestTowerAvenue Milwaukee,WI53223USA Tel:+14143555000
+18005587044(USOnly)
Fax:+14143553790
GEMedicalSystems InformationTechnologiesGMβH MunzingerStraße5 D-79111FreiburgGermany Tel:+497614543-0 Fax:+497614543-233
AsiaHeadquarters
GEMedicalSystems
InformationTechnologies
Asia;GE(China)Co.,Ltd. No.1HuatuoRoad ZhangjiangHi-techParkPudong Shanghai,People’sRepublicofChina201203 Tel:+862152574650 Fax:+862152082008
GEMedicalSystemsInformationTechnologies,aGeneralElectricCompany,goingtomarketas GEHealthcare.
www.gehealthcare.com
Loading...