GEHealthcare
MAC™2000ECGAnalysisSystem
SuppliesandAccessories
ReferenceGuide
2053535-004RevisionD
English
©2013-2014GeneralElectricCompany.
AllRightsReserved.

PublicationInformation
TheinformationinthismanualappliesonlytoMAC™2000.Duetocontinuingproductinnovation,specicationsinthismanualaresubjectto
changewithoutnotice.
MACisatrademarkownedbyGEMedicalSystemsInformationTechnologies,Inc.,aGeneralElectricCompanygoingtomarketasGE
Healthcare.Allothertrademarkscontainedhereinarethepropertyoftheirrespectiveowners.
Thisproductcomplieswiththerequirementsconcerningmedicaldevicesfromthefollowingregulatorybodies:
Thedocumentpartnumberandrevisionareoneachpageofthedocument.Therevisionidentiesthedocument’supdatelevel.Therevision
historyofthisdocumentissummarizedinthefollowingtable.
Revision
A
B
C19August2013
D
Date
17October2012Internalrelease
19April2013Customerrelease
31January2014
Comments
Allreferencestothesoftwareversionnumberwereremovedfromthemanual
perSPRHCSDM00229788.
AddedCEmarkinformationtoPublicationInformationandonbackpage;added
sentenceinChapter2,Supplies&Accessories,notingthatCEinformationison
individualitempackagingandlabeling:perSPRHCSDM00264047.
ToaccessotherGEHealthcareDiagnosticCardiologymanuals,gototheCommonDocumentationLibrary(CDL),locatedat
www.gehealthcare.com/documents
ToaccessOriginalEquipmentManufacturer(OEM)manuals,gotothedevicemanufacturer'sWebsite.
,andclickCardiology.
2
MAC™2000ECGAnalysisSystem
2053535-004D
31January2014

Contents
1Introduction
OrderingInformation..................................................................................5
RegulatoryandSafetyInformation.............................................................6
2SuppliesandAccessories
Supplies.......................................................................................................9
Accessories...............................................................................................10
3Maintenance
Cleaning,Disinfecting,andStoringECGCablesandLeadwires................17
SafetyMessages.......................................................................................7
CleaningGuidelines..................................................................................17
CleaningandDisinfectingCablesandLeadwires..............................................18
StoringCablesandLeadwires.....................................................................19
Cleaning,Disinfecting,andSterilizingReusableElectrodes.....................19
ReplacingLeadwireAdapters...................................................................20
PaperMaintenance...................................................................................21
ReplacingPaper......................................................................................21
StoringThermalPaper...............................................................................22
2053535-004D
MAC™2000ECGAnalysisSystem
3

4
MAC™2000ECGAnalysisSystem
2053535-004D

1
Introduction
QualitysuppliesandaccessoriesforyourGEHealthcaredeviceplayanimportantrole
inensuringthatyoursystemperformsatthehighlevelyouhavecometoexpect
fromGEHealthcare.
UsethismanualasyourguidefortheGEHealthcaresuppliesandaccessoriesthat
haveprovencompatibilitywithyourdevice.Fromelectrodes,cables,andleadwires
torecordingpaper,youcanbeassuredthateachproductlistedwastestedand
validatedwiththedevice,enablingyoursystem'sperformancetoberepresentativeof
GEHealthcare'squality.
YoucanrelyonGEHealthcareasyourtrustedsourceforsuppliesandaccessories
afteryouroriginalpurchaseandthroughoutthelifeofyoursystem.
Additionalinformationregardingtheuseofsuppliesandaccessorieswiththisdevice
maybefoundintheproductoperatormanualortheinstructionsforuseofthe
particularsupplyoraccessory.
OrderingInformation
Theavailabilityofsuppliesandaccessoriesvariesbycountry.Contactyourlocal
GEHealthcarerepresentativetocheckontheavailabilityofselectedsuppliesand
accessoriesinyourregion.
Americas
NorthAmerica
T:1–800–558–7044,option#2
F:1–800–421–4841
msdcarhardcopyorders@ge.com
CanadaandLatinAmericaforVSDProducts
T:1–800–932–0760
F:1–973–956–5437
vsdinternationalcoordination@ge.com
AsiaPacic
Australia
T:+611800223615
F:+61298464762
medanzdocustomerservice@med.ge.com
India
T:+918028452923/25/26
F:+918028452924
2053535-004D
MAC™2000ECGAnalysisSystem
5

Introduction
CanadaforGELegacyProducts
T:1–800–668–0732,option#3
F:1–888–988–6822
can-caresdia@med.ge.com
Europe
Denmark
T:+4543295885
F:+4543295701
ordregehcit@ge.com
Finland
T:+358103945466
T:+358103945422
F:+35891463310
nlandorders@ge.com
France
T:+33478666210
F:+33478667904
advlimonest@ge.com
Germany
T:+497614543601
F:+497614543608
Japan
T:+81425855111
Korea
T:+82262013114
AssociationofSoutheastAsianNations
T:+6562918528
Norway
T:+4723185050
F:+4723186040
Russia
T:+74957396931
F:+74957396932
Spain
T:(0034)902100163
F:(0034)902100178
gevsdattcliente@ge.com
Sweden
T:+46855950010
F:+46855950015
orderswe@ge.com
Italy
T:(0039)0226001622
F:(0039)0226001625
Netherlands
T:+31(0)332541222
F:+31(0)332541223
ordershoev@ge.com
RegulatoryandSafetyInformation
Thissectionprovidesinformationaboutthesafeuseandregulatorycomplianceofthe
suppliesandaccessoriesforthissystem.Familiarizeyourselfwiththisinformation,
andreadandunderstandallinstructionsbeforeattemptingtousethesesupplies
andaccessories.
6
MAC™2000ECGAnalysisSystem
Turkey
T:+903122897700
F:+903122897802
UnitedKingdom
T:+44(0)1707274183
F:uk.customersalesofce@med.ge.com
ehandel@ge.com
2053535-004D

Introduction
SafetyMessages
WARNING:
PATIENTSAFETY/EQUIPMENTFAILURE—Usingunauthorizedsuppliesor
accessoriescanresultinpatientinjuryorequipmentfailure.
Toensurepatientsafety,useonlysuppliesandaccessoriesmanufacturedor
validatedbyGEHealthcareandrecommendedforusewiththisdevice.
Parts,supplies,andaccessoriesmustmeettherequirementsoftheapplicable
safetystandards.Thesystemcongurationmustmeettherequirementsofthe
IEC60601/EN60601-1MedicalElectricalSystemsstandard.Usingaccessory
equipmentthatdoesnotcomplywiththeequivalentsafetyrequirementsofthis
equipmentmayleadtoareducedlevelofsafetyoftheresultingsystem.
Whenchoosingaccessories,considerthefollowing:
•Useoftheaccessoryinthepatientvicinity.
Patientvicinityisdenedasaspace,withinalocationintendedfortheexamination
andtreatmentofpatients,extending1.83m(6ft.)beyondthenormallocationof
thebed,chair,table,treadmill,orotherdevice(s)supportingthepatientduring
examinationandtreatment,andextendingverticallyto2.5m(8ft.,2.4in.)above
theoor .
•Evidencethatthesafetycerticationoftheaccessorywasperformedinaccordance
withtheappropriateIEC60601/EN60601-1standard(s).
ContactGEHealthcareforinformationbeforeconnectingthedevicetoany
accessoriesthatarenotrecommendedinthismanual.
2053535-004D
MAC™2000ECGAnalysisSystem
7

Introduction
8
MAC™2000ECGAnalysisSystem
2053535-004D

SuppliesandAccessories
Supplies
2
Thischapteridentiessuppliesandaccessoriesthatareapprovedforusewith
yoursystem.Seeindividualsuppliesandaccessoriespackagingandlabelingfor
CEmarkinginformation.
Paper
PartNumber
2009828-061
2020314-001
22616605
22616606
22616611
Creams,Gels,Sprays,Pads
PartNumber
2034731-002
2034741-002
2046978-001
21708318
21730701
Description
GEPremiumThermal-SensitiveChartPaper,RedGridBlank
InterpretationArea,8.43inx11in.(214.2mmx279.4mm)
Sheet,Z-fold,QueueHole,150sheets/pack,16packs/case,2400
sheets/case.
GEPremiumThermal-SensitiveChartPaper,FullPageRedGrid,A4,
210mmx295mm(8.26inx11.61in.)Sheet,Z-fold,QueueMark,
150sheets/pack,10packs/case,1500sheets/case
GEContrastThermal-SensitiveChartPaper ,FullPageRedGrid,A4,
210mmx295mm(8.26inx11.61in.)Sheet,Z-fold,QueueMark,
150sheets/pack,10packs/case,1500sheets/case
GEContrastThermal-SensitiveChartPaper ,FullPageRedGrid,
216mmx280mm(8.5inx11in.)Sheet,Z-fold,QueueMark,150
sheets/pack,10packs/case,1500sheets/case
GEArchivistThermal-SensitiveChartPaper,FullPageRedGrid,A4,
210mmx295mm(8.26inx11.61in.)Sheet,Z-fold,QueueMark,
150sheets/pack,10packs/case,1500sheets/case
Description
ElectrodeGel,250mlbottle,4/case
EpicontCream,250mlbottle,4/case
ElectrodeCream,250mlbottle,4/case
ElectrodeCream,250mlbottle
ElectrodeContactSpray,200mlbottle
2053535-004D
MAC™2000ECGAnalysisSystem
9

SuppliesandAccessories
Creams,Gels,Sprays,Pads(cont'd.)
PartNumber
21730702
21730705
401210-001
401210-003
Description
ElectrodeContactSpray,200mlbottle,10/box
ElectrodeContactSpray,2L
Signacreme®ElectrodeCream,5ozbottle,12/case
Signacreme®ElectrodeCream,70ozbottlew/pump
Accessories
Electrodes,Non-polarizing
PartNumber
2014780-001
2014783-001
2014784-001
2014785-001
2014786-001
2046545-001
21714401
402207-810
42101600
900703-805
900703-830
91920031
9623-810
9623-810P
Description
SilverTRACEECGElectrodes,SoftStressPS50MO,foamround,wet
gel,30/pouch,300/box
SilverTRACEECGElectrodes,WindowP50TR,cleartaperound,solid
gel,30/pouch,300/box
SilverTRACEECGElectrodes,WindowP50TR,cleartaperound,solid
gel,5/strip,300/box
SilverTRACEECGElectrodes,WindowP50TR,cleartaperound,solid
gel,7/strip,350/box
SilverTRACEECGElectrodes,FirstCarbonP28MOC,foamrectangle,
wetgel,carbonsnap,30/pouch,300/box
ECGElectrode,WetGelP28MOC,SilverTRACEElectrodes,30/pack
SuctionBulbElectrode,ThoraxElectrode
BabyMACElectrodes,RestingECGElectrodes,10/card,50/pack,
500/case
SuctionBulb32x33rubberblue
SilverTRACEAg/AgClElectrodes,AdultHolter/StressElectrode,Foam
Oval,WetGel,5/pkg,150/box,600/case
SilverTRACEAg/AgClElectrodes,AdultHolter/StressElectrode,Foam
Oval,WetGel,30/pouch,300/case
SilverTRACEECGElectrodes,SoftP55MO,foamround,wetgel,
25/pouch,200/box
SilverMactrodeRestingECGElectrodes,10/card,100/pack,
1000/case
SilverMactrodePlusRestingECGElectrodes,10/card,100/pack,
1000/case
Leadwires
PartNumber
2001925-003
2001925-004
10
Description
CAM14ECGLeadwire,Universal,40in(102cm)
CAM14ECGLeadwire,Universal,51in(130cm)
MAC™2000ECGAnalysisSystem
2053535-004D

Leadwires(cont'd.)
SuppliesandAccessories
PartNumber
2001925-005
2001925-006
2016032-001
Description
CAM14ECGLeadwire,Universal,26in(66cm)
CAM14ECGLeadwire,Universal,36in(90cm)
CAM14LeadwireSet,DedicatedBanana,AHA,10/set,mixed
lengths
2016032-002
2020558-001
2020558-002
2020558-003
2020558-004
2020558-005
2020558-006
2020558-007
2020558-008
2020558-009
2020558-010
2020559-001
2020559-002
2020559-003
2020559-004
2020559-005
2020559-006
2020559-007
2020559-008
2020559-009
2020559-010
38401765
CAM14LeadwireSet,DedicatedBanana,IEC,10/set,mixedlengths
CAM14ECGLeadwire,DedicatedBanana,AHA,36in(90cm),RA
CAM14ECGLeadwire,DedicatedBanana,AHA,36in(90cm),LA
CAM14ECGLeadwire,DedicatedBanana,AHA,40in(102cm),LL
CAM14ECGLeadwire,DedicatedBanana,AHA,40in(102cm),RL
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V1
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V2
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V3
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V4
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V5
CAM14ECGLeadwire,DedicatedBanana,AHA,26in(66cm),V6
CAM14ECGLeadwire,DedicatedBanana,IEC,36in(90cm),R
CAM14ECGLeadwire,DedicatedBanana,IEC,36in(90cm),L
CAM14ECGLeadwire,DedicatedBanana,IEC,40in(102cm),F
CAM14ECGLeadwire,DedicatedBanana,IEC,40in(102cm),N
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C1
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C2
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C3
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C4
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C5
CAM14ECGLeadwire,DedicatedBanana,IEC,26in(66cm),C6
ECGLeadwireSetwithResistance,Banana,IEC,10/set,mixed
lengths
38401766
ECGLeadwireSetwithResistance,Banana,IEC,NST&NAX,27in
(70cm)
38401816
ECGLeadwireSet,Banana,10/set,IEC,mixedlengths
2053535-004D
MAC™2000ECGAnalysisSystem
11

SuppliesandAccessories
Leadwires(cont'd.)
PartNumber
38401817
420101-002
Description
ECGLeadwireSet,Banana,10/set,AHA,mixedlengths
CAM14ECGLeadwireSet,Universal,mixedlength,10/set
LeadwireAccessories
PartNumber
401089-003
414763-002
Description
LeadwireOrganizers,43-LSeparators,24-LSeparators
Multi-LinkLeadwireSeparator,3-L,3/pack
Cables
PartNumber
2029890-001
2029893-001
22336203
22338002
22339003
22340305
22341808
22341809
Description
ValueECGCable/Leadwires,10-L,IEC
ValueECGCable/Leadwires,10-L,AHA
ConnectioncabletoCardioSys
ConnectioncableforeBike
ConnectioncableforT2000/T2100
ECGCable,14-L,IEC,2.5m(8ft)
ECGCable,Multi-Link,10-L,IEC,2.5m(8ft)
ECGCable,Multi-Link,MAC500/1200,10-L,AHA,3m(10ft)
ECGAdaptersandConnectors
PartNumber
2029891-001
2029892-001
2029894-001
2056813-010
900178-001
900178-002
900178-003
900178-101
12
Description
ReusableLimbClamps,IEC,4/set
ReusableBulbElectrodes,6/set
ReusableLimbClamps,AHA,4/set
ElectrodeAdapterSet,10/set
CAM14ECGConnectorSet,Banana,10/set,AHA
CAM14ECGConnectorSet,Mactrode,10/set,AHA
CAM14ECGConnectorSet,Grabber,10/set,AHA
CAM14ECGConnectorSet,Banana,10/set,IEC
MAC™2000ECGAnalysisSystem
2053535-004D

ECGAdaptersandConnectors(cont'd.)
SuppliesandAccessories
PartNumber
900178-102
900178-103
Description
CAM14ECGConnectorSet,Mactrode,10/set,IEC
CAM14ECGConnectorSet,Grabber,10/set,IEC
KISSAccessories
PartNumber
2024037-001
2024039-001
21612113
21612202
21732801
22341410
22341415
30344365
30344366
30344367
30344368
30344369
30344370
30344371
30344372
30344373
30344374
30344375
30344376
30344377
30344419
30344420
30344421
30344427
30344434
30344435
30344436
30344437
30344438
Description
KISSES600Electrodes&Leadwires,Standard,10/set,mixedlengths
KISSUpgradeElectrodes&Leadwires,NEHB,2/set,127cm(50in),
Nst,Nax
ElectrodeApplicationSystemKISS10Leadwithoutpump
ElectrodeApplicationSystemKISS12Leadwithoutpump
SuctionElectrode,KISSES600
TrunkCable,KISS,12-LwithTube
Cable,KISS,12-L
Leadwire,KISS,IEC,127cm(50in),C1
Leadwire,KISS,IEC,127cm(50in),C2
Leadwire,KISS,IEC,127cm(50in),C3
Leadwire,KISS,IEC,127cm(50in),C4
Leadwire,KISS,IEC,127cm(50in),C5
Leadwire,KISS,IEC,127cm(50in),C6
Leadwire,KISS,IEC,147cm(57in),F
Leadwire,KISS,IEC,147cm(57in),L
Leadwire,KISS,IEC,147cm(57in),R
Leadwire,KISS,IEC,147cm(57in),N
Leadwire,KISS,IEC,127cm(50in),NST
Leadwire,KISS,IEC,127cm(50in),NAX
SwivelAttachmentArmforKiss
ExtensiontubeforKISSES600Pump,1.5m(5ft)
ErgometerMountingArm,KISS
LeadwireClipAdapter,KISS,fordisposableelectrodes
BlindPlugforKISS
Leadwire,KISS,AHA,127cm(50in),V1
Leadwire,KISS,AHA,127cm(50in),V2
Leadwire,KISS,AHA,127cm(50in),V3
Leadwire,KISS,AHA,127cm(50in),V4
Leadwire,KISS,AHA,127cm(50in),V5
2053535-004D
MAC™2000ECGAnalysisSystem
13

SuppliesandAccessories
KISSAccessories(cont'd.)
PartNumber
30344439
30344440
30344441
30344442
30344443
38401584
38401590
43252125
93204775
Description
Leadwire,KISS,AHA,127cm(50in),V6
Leadwire,KISS,AHA,147cm(57in),LL
Leadwire,KISS,AHA,147cm(57in),LA
Leadwire,KISS,AHA,147cm(57in),RA
Leadwire,KISS,AHA,147cm(57in),RL
KISSMountingTableKit
KISSLeadwireSet,IEC,10/set,mixedlengths
SuctionDome,KISS
KISSElectrodeFilterDisc,100/bag
BarcodeAccessories
PartNumber
2035979-001
2035979-002
2035979-003
2035979-004
2035979-005
2035979-006
2035979-008
2035979-009
2035979-010
2035979-011
2035979-014
2035979-016
2035979-017
Description
BarcodeScanner—English
BarcodeScanner—German
BarcodeScanner—French
BarcodeScanner—Spanish
BarcodeScanner—Swedish
BarcodeScanner—Italian
BarcodeScanner—Dutch
BarcodeScanner—Norwegian
BarcodeScanner—Danish
BarcodeScanner—Czech
BarcodeScanner—Hungarian
BarcodeScanner—Russian
BarcodeScanner—Slovene
14
MAC™2000ECGAnalysisSystem
2053535-004D

BarcodeAccessories(cont'd.)
SuppliesandAccessories
PartNumber
2035979-018
2035979-020
Description
BarcodeScanner—Portuguese
BarcodeScanner—Finnish
StorageAccessories
PartNumber
2073012-001CARDSECUREDIGITAL-4GB
Description
PowerCords
PartNumber
401855-001EURO-PWRSPL YCRDRACONTEURO10A250V2.5M
401855-002
401855-003
401855-004
401855-110
401855-018
401855-107
401855-108
405535-006US-PWRSPL YCRDRAHOSPGRD13A125V10FT
405535-011Japan-PWRSPL YCRDST-RAPSE10A250V10FT
401855-041
Description
British-PWRSPLYCRDRABRITSH10A250V2.5MFSD
Italian-PWRSPL YCRDRAITALIAN10A250V2.5M
Israel-PWRSPL YCRDRAISRAELI10A250V2.5M
Australia-PWRSPLYCRDRAAUSTRALIAN10A250V2.5M
China-PWRCRDSTCHINARAPLUG10A250V2.5M
Swiss-PWRSPL YCRDSTSWISS10A250V2.5M
India-PWRSPL YCRDSTINDIAN10A250V2.5M
Brazil-PWRSPL YCRDSTBRAZIL10A250V2.5M
2053535-004D
MAC™2000ECGAnalysisSystem
15

SuppliesandAccessories
16
MAC™2000ECGAnalysisSystem
2053535-004D

Maintenance
Thischapterprovidesinformationaboutthemaintenanceoftheaccessoriesused
withyoursystem.
Cleaning,Disinfecting,andStoringECGCables
andLeadwires
Inadditiontokeepingthesystemcleanandingoodrepair,itisimportanttokeepthe
cablesandleadwirescleananddisinfected.Thissectionprovidesinstructionsfor
cleaning,disinfecting,andstoringECGcablesandleadwirestoextendtheirlifeand
protectpatients.Cablesandleadwirescomeintocontactwithpatientsandshouldbe
cleanedanddisinfectedaftereveryuse.
NOTE:
FordeviceswiththeKISSsystem,refertotheKISSoperator'smanualforcleaning
anddisinfectinginformation.
3
CleaningGuidelines
Observethefollowingguidelineswhencleaninganddisinfectingthecables,leadwires,
andelectrodesforyoursystem.
•Followthecleaninginstructionsexactly.
•Wringexcessdisinfectantfromthewipebeforeusingit.
•Neverimmersethedevice,cables,orleadwiresinanyliquid,asthismaycorrode
metalcontactsandaffectsignalquality.
•Donotallowliquidstocollectaroundtheconnectionpins.Ifthishappens,blotthem
drywithasoft,lint-freecloth.
•Neveruseconductivesolutionsorsolutionsthatcontainchlorides,wax,orwax
compoundstocleanthedevice,cables,orleadwires.
•NeverusesolutionsorproductsthatcontainanytypeofAmmoniumChloridesuch
as,butnotlimitedto:
•DimethylBenzylAmmoniumChloride
•QuaternaryAmmoniumChloridesolutions
•Abrasivecleanersorsolventsofanykind
•Acetone
2053535-004D
MAC™2000ECGAnalysisSystem
17

Maintenance
•Ketone
•Betadine
•Alcohol-basedcleaningagents
•Sodiumsalts
•Neverautoclaveorsteamcleanthedevice,cables,orleadwires.
•Donotuseanyoftheaccessoriesuntilthoroughlydry.
•DoNOTimmerseeitherendofacableorleadwireconnectorinanysolution.
Immersingorsoakingtheconnectorendsmaycorrodemetalcontactendsand
affectsignalquality.
•DoNOTletliquidscollectaroundtheconnectionpins.
Ifthishappens,blotthemdrywithasoft,lint-freecloth.
CleaningandDisinfectingCablesandLeadwires
Propercleaninganddisinfectingprolongsthelifeofthecablesandleadwires.Failure
tousethepropercleaningsolutionsortofollowtheproperprocedurescanresultin
thefollowing:
•Damageorcorrosion
•Diminishedsignalquality
•Productdiscoloration
•Metalpartcorrosion
•Brittlewiresandconnectors
•Reducedcablesandleadwireslife
•Devicemalfunction
•Voidedwarranty
CleaningtheCablesandLeadwires
Usethefollowingproceduretocleanthecablesandleadwires:
NOTE:
•Whileperformingthefollowingprocedure,usecareincleaningtheleadwires
topreventpullingthewiresfromtheconnectorends,becausethemetal
connectionscanbepulledawayfromtheconnectors.
•Cleaningremovesdirtandmarksbutdoesnotdisinfectthecablesand
leadwires.
1.Removethecablesandleadwiresfromthedevicebeforecleaning.
2.Wipethemwithaclothlightlymoistenedwithamildsolutionofsoapandwater.
Donotuseanyofthefollowingcleaningproducts,orproductsthatcontainthe
sameactiveingredientsandsolutions,whichareknowntocausetheproblems
previouslylisted:
•Sani-Cloth®Wipes
•Ascepti®Wipes
•HBQuat®
18
MAC™2000ECGAnalysisSystem
2053535-004D

•Clorox®Wipes(theydonotcontainbleach)
•Over-the-counterdetergents(suchasFantastic®,Tilex®,andsoon)
3.Wipethecablesandleadwireswithadry,cleanclothorpapertowelandlet
themairdry.
DisinfectingtheCablesandLeadwires
Usethefollowingproceduretodisinfectthecablesandleadwires:
1.Cleananddrythecablesandleadwiresbeforedisinfectingthem.
See“CleaningtheCablesandLeadwires”onpage18forinstructions.
2.Wipethecablesandleadwireswithasoft,lint-freecloththatismoistenedwith
anappropriatedisinfectant.
Usethefollowingsolutions,asrecommendedinAPICGuidelinesforSelection
andUseofDisinfectants(1996):
•Sodiumhypochlorite(5.2%householdbleach)minimum1:500dilution
(minimum100ppmfreechlorine)andmaximum1:10dilution.
Maintenance
•Anysodiumhypochloritewipeproductthatmeetsthepreviousguidelines.
3.Drythecablesandleadwireswithacleanclothorpapertowelandletthem
airdryforatleast30minutes.
NOTE:
•Dryingtimesvarybasedontheenvironmentalconditions.
•DONOTuseexcessivedryingtechniques,suchasovens,forcedheat,or
sundrying.
StoringCablesandLeadwires
Toensurethatthecablesandleadwiresareinproperworkingorder,usethefollowing
guidelinestostorethemwhennotinuse:
•Storecablesandleadwiresinadry,well-ventilatedarea.
•Hangcablesandleadwiresvertically
•DoNOTcoilcablesorleadwiresaroundthedevice.
Cleaning,Disinfecting,andSterilizingReusable
Electrodes
Cleanreusableelectrodesimmediatelyafterusingthemonapatient.
2053535-004D
MAC™2000ECGAnalysisSystem
19

Maintenance
CleaningandDisinfectingReusableElectrodes
Usethefollowingproceduretocleananddisinfectthereusableelectrodes:
1.Usewarmwaterandasmallbrushtoremoveanycreamorgelfromthe
electrode.
Donotusepointedorsharpobjectsforcleaning.
2.Disinfecttheelectrodeswithalcohol-freedisinfectant.
Ensurethattheconnectorsandsocketsdonotgetwet.
SterilizingReusableElectrodes
Usethefollowingproceduretosterilizereusableelectrodes:
Theonlyapprovedsterilizationmethodisgassterilization.
1.Sterilizereusableelectrodeswithethyleneoxidegas(EtO)atamaximum
temperatureof50°C(122°F).
2.Aftersterilizationiscomplete,followthemanufacturer'srecommendationsfor
requiredaeration.
ReplacingLeadwireAdapters
Althoughpropercleaningandstorageprolongthelifeofleadwires,youeventually
needtoreplacetheleadwireadapters.Thefollowingillustrationshowstheproper
methodforreplacingadapters.
20
MAC™2000ECGAnalysisSystem
2053535-004D

PaperMaintenance
ReplacingPaper
Maintenance
Fortheproperhandlingofthedevice'sthermalwriter,youneedtoknowhowtodo
thefollowing:
•Replacepaper
•Storethermalpaper
Usethefollowingproceduretoaddorreplacepaper:
1.Pressthepushbuttononthetopofthedevice(1)toopentheprinterdoor(2).
2.Extendthetopsheetofthepackofpaperandinsertthepackintothepaper
compartment(3).
2053535-004D
MAC™2000ECGAnalysisSystem
21

Maintenance
3.Closetheprinterdoor(4)untilitclicksintoplace(5).
StoringThermalPaper
Whenimagedandstoredproperly,ECGtracingsresistfadingforseveralyears.Ifyour
retentionrequirementsexceedveyears,considerusingGEHealthcareArchivist
paper.
Toensurethetracingisimagedproperly,thedevicemustbemaintainedin
accordancewithitsservicemanualsandtechnicalmemoranda.
Toensurethetracinglastsforthepaper'sexpectedlifespan,observethefollowing
guidelineswhenstoringyourprintouts:
•Storeinacool,dark,anddrylocation.
•Standardpaper
Temperaturemustbelessthan27°C(80°F).
Relativehumiditymustbelessthan65%.
Alignthetopsheetofthepapertothelinelocatedonthenearsideofthe
printerdoor.
•Archivistpaper
Temperaturemustbelessthan40°C(104°F).
Relativehumiditymustbebetween40%and60%.
•AvoidexposuretobrightlightorUVsources.
Sourcesofultravioletlightincludesunlight,uorescentlights,halogenlights,
mercuryvaporlamps,andgermicidallamps.
•Avoidcontactwithcleaningliquidsandsolvents.
Solventstoavoidincludealcohols,ketones,esters,ether,andsoforth.
•Storethermalpaperseparatelyinmanilafoldersorpolyesterorpolyimide
protectors.
Plasticdocumentprotectors,envelopes,orsheetseparatorsmadeofpolystyrene,
polypropylene,orpolyethylenedonotdegradethermaltraces.However ,these
materialsaffordnoprotectionagainstfadingfromexternalcauses.
•DoNOTstorethermalpaperswithanyofthefollowing:
•carbonorcarbonlessforms
•documentprotectors,envelopes,andsheetseparatorscontainingpolyvinyl
chlorideorothervinylchlorides.
•non-thermalchartpapersoranyotherproductscontainingtributylphosphate,
dibutylphthalate,oranyotherorganicsolvents
NOTE:
Manymedicalandindustrialchartscontainthesechemicals.
•DoNOTusemountingforms,pressure-sensitivetapes,andlabelsthatuse
solvent-basedadhesives.
Useonlymountingformsandpressure-sensitivetapesmadewithstarchor
water-basedadhesives.
22
MAC™2000ECGAnalysisSystem
2053535-004D

Index
A
accessories6
B
barcodeaccessories14
C
cables12
cleaninganddisinfecting18
storing19
cleaning
guidelines17
solutionsnottouse17
cleaninganddisinfecting
cables18
electrodes20
leadwires18
cleaning,disinfecting,and
sterilizing
electrodes19
CommonDocumentation
Library(CDL)2
compliance2,6
creams9
D
G
GEHealthcare
CommonDocumentation
Library(CDL)2
manuals2
gels9
guidelines
whencleaningand
disinfecting17
K
KISS
accessories13
L
leadwireaccessories12
leadwires10
cleaninganddisinfecting18
replacingadapters20
storing19
M
maintenance
replacingleadwire
adapters20
disinfecting
guidelines17
solutionsnottouse17
document
partnumber2
revision2
E
ECGadaptors12
ECGconnectors12
electrodes10
cleaninganddisinfecting20
cleaning,disinfecting,
andsterilizing19
sterilizing20
2053535-004D
MAC™2000ECGAnalysisSystem
N
non-polarizingelectrodes10
O
OEM2
orderinginformation
suppliesandaccessories5
OriginalEquipment
Manufacturer(OEM)2
P
pads9
23

paper
replacing21
storing22
Paper9
partnumber
document2
patientvicinity
denition7
powercords15
R
regulatoryinformation6
replacing
leadwireadapters20
revisionhistory2
S
safetyinformation6
solutions
nottousewhencleaning
ordisinfecting17
sprays9
sterilizing
electrodes20
storage
accessories15
cablesandleadwires19
paper22
suppliesandaccessories
barcodeaccessories14
cables12
creams,gels,sprays,pads9
ECGadaptorsand
connectors12
electrodes10
KISSaccessories13
leadwireaccessories12
leadwires10
orderinginformation5
paper9
powercords15
SDcard15
storageaccessories15
24
MAC™2000ECGAnalysisSystem
2053535-004D


GEMedicalSystems
InformationTechnologies,Inc.
8200WestTowerAvenue
Milwaukee,WI53223USA
Tel:+14143555000
+18005587044(USOnly)
Fax:+14143553790
GEMedicalSystems
InformationTechnologiesGmbH
MunzingerStraße5
D-79111FreiburgGermany
Tel:+497614543-0
Fax:+497614543-233
AsiaHeadquarters
GEMedicalSystems
InformationTechnologies,Inc.
Asia;GE(China)Co.,Ltd.
1HuatuoRoad
ZhangjiangHi-techParkPudong
Shanghai,People'sRepublicofChina201203
Tel:+862138777888
Fax:+862138777451
GEMedicalSystemsInformationTechnologies,Inc.,aGeneralElectricCompany,goingtomarketas
GEHealthcare.
www.gehealthcare.com
0459