JVM7195SK/EK/BL/FL
98°
Door open
(without obstruction)
23-9/16"
29-7/8"
16-5/16"
(rear)
15-9/16"
15-11/16"
13"
MAX.
12"
MIN.*
66" MIN.
Mounting
height from
floor
Minimum distance from
door hinge side to
adjacent wall should
equal 1/2"
30" MIN.
width
required
Exhaust outlet
connects to
3-1/4"x10" duct
*Maximum depth
with JX15
Bump Out Kit is 16"
Bump Out Kit
sold separately.
GE® 1.9 cu. ft. Over-the-Range Sensor Microwave Oven
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Requires 120V grounded outlet. Electrical receptacle
must be located in cabinet above microwave oven. No
additional wiring, venting or cabinet rebuilding necessary
in many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed
with the microwave oven.
IMPORTANT INFORMATION: When installing the
microwave oven over a range, allow minimum of 2" from
bottom of microwave oven to top of range backguard to
allow for removal of light covers.
VENTILATION OPTIONS: The microwave ovens
are designed for adaptation to the following three
types of ventilation:
-Outside exhaust (vertical – as shown)
-Outside exhaust (horizontal)
-Recirculating (non-vented ductless – see Filter Kit drawing)
INSTALL AT ION INFORMAT ION : This information is
not intended to be used for installing unit described. Before
installing, consult installation instructions packed with
product/kit for current dimensional data.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 3/20
JVM7195SK/EK/BL/FL
GE® 1.9 cu. ft. Over-the-Range Sensor Microwave Oven
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate
with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be used. Do not use less than a
6" diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present
additional resistance to airflow and are equivalent to a section of straight
duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the
lengths of all straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wal l Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
Filter Kit
WB06X10807
Filler Panel Kit
JX36DWW/DBB/DSS/DES/DTS/DDS
When replacing a 36" range hood,
this kit fills in the additional width to
provide a custom built-in
appearance. For installation
between cabinets only; not
for end-of-cabinet installation.
Each kit contains two 3"-wide
filler panels.
Recirculating
Charcoal Filter Kit
To be used when
the microwave oven
cannot be vented to
the outside.
Speci fication Revised 3/20