INSTALLATION INSTRUCTIONS (USA only)
MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM
IN ORDER TO OPERATE ADEQUATELY.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT- Save these instruc-
tions for local inspector’s use.
•
IMPORTANT- Observe all govern-
ingcodes and ordinances.
•
Note to Installer - Be sure to leave these instruc-
tions with the customer.
Note to Customer - Keep these instructions with
•
your Use and Care Book for future reference.
Before the old dryer is removed from service or
•
discarded, remove the dryer door.
Service information and the wiring diagram are
•
located in the control console.
Do not allow children on or in the appliance. Close
•
supervision of children is necessary when the
appliance is used near children.
Install the dryer where the temperature is above
•
50°F for satisfactory operation of the dryer control
system.
WARNING
To reduce the risk of severe injury or death, follow all installation
•
instructions.
•
Clothes dryer installation must be performed by a qualified
installer.
Install the clothes dryer according to these instructions and in
•
accordance with local codes.
This dryer must be exhausted to the outdoors.
•
•
Use only 4” rigid metal ducting for exhausting the clothes dryer
to the outdoors.
DO NOT install a clothes dryer with flexible plastic ducting
•
materials. If flexible metal (semi-rigid or foil-type) duct is
installed, it must be UL listed and installed in accordance with
the instructions found in "Connecting The Dryer To House
Vent" on page 4 of this manual. Flexible venting materials are
known to collapse, be easily crushed, and trap lint. These
conditions will obstruct dryer airflow and increase the risk of fire.
Do not install or store this appliance in any location where it
•
could be exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave these
•
instructions with the customer).
RISK OF FIRE
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
This dryer must be connected to an individual branch circuit of proper voltage and frequency as specified on Rating Plate (located inside dryer
•
door) with no other appliances or fixtures attached.
EXCEPTION:
A 120V receptacle is located on the back on the dryer and is available only for use with a washer that is affixed to the dryer with a WDF-85 kit. It may
•
not be used for any other appliance or any conditions other than slated above (208 & 240V models only).
Branch circuit must be protected by the required time-delay fuses or circuit brackers 208V or 240V installation - 30 amps 120V installation 15 or 20 amps.
•
The electrical installation must conform to the national and local codes.
•
208V AND 240V MODELS ARE NOT APPROVED FOR120 V INSTALLATION.
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
PHILLIPS SCREWDRIVER
STACKING KITS FOR DRYERS
(comes with individual installation instructions)
Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24
For alcove and closet depth and
width requirements see
specific kit instructions
All stacking kits are available
from your local sales outlet.
FLAT BLADE SCREWDRIVER
MATERIALS YOU WILL NEED
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
DUCT TAPE
4" DIA. METAL
ELBOW
EXHAUST
HOOD
GLOVES
UNPACKING AND PREPARING FOR INSTALLATION
Prepare the area and exhaust for installation of new dryer.
Check and ensure the existing external exhaust is clean and meets attached installation specifications.
Remove the literature and accesories bag from the dryer drum. Place the literature in a convenient place.
Using foam pads from dryer carton, turn dryer upside down as shown.
Install knobs. For location, refer to “Use and Care” Book.
Dryer is now ready to be mounted above washer using accessory kit.
Remove the foam shipping pads from under dryer.
Move the dryer to the desired location.
Follow the steps in the following pages to connect the dryer to the external exhaust and power supply.
SAFETY
GLASSES
UL RATED
120/240V,30A
WITH 3 OR 4 PRONGS.
3/4" STRAIN
RELIEF
UL RECOGNIZED
IDENTIFY THE PLUG
TYPE AS PER THE
HOUSE RECEPTACLE
BEFORE PURCHASING
LINE CORD.
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
PAGE 1
ELECTRICAL CONNECTION DETAILS
OBSERVE ALL GOVERNING CODES AND ORDINANCES
GROUNDING INSTRUCTIONS
The operating voltage (Volts), Amperage (Amps) and Frequency
(Hz) of this dryer are indicated on the Rating Plate located to the
right of the loading port.
Connect this dryer to a circuit corresponding to that indicated on
rating plate and protected by fuses or a circuit breaker
in accordance with local codes.
Use a power supply cord kit marked for use with clothes dryer.
For 208V and 240V models, use a power supply cord kit marked for use
with clothes dryers.
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
For alternate 208V or 240V power supply hook-up, proceed as follows:
Remove rear access panel.
Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation.
WARNING: Appliance grounded to neutral conductor through a link. If used in a mobile home or if local codes do not permit grounding through neutral, a
4-conductor cord or cable assembly for use with clothes dryers must be used with the following specifications: Type St. Cable, 125/250 Min Volt, 30 Amp
with closed-loop terminals and secured with a UL recognized strain relief. See manufacturer’s instructions
Make sure screws on terminal block are tight.
This appliance must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock by providing
a path of least resistance for electrical current.
WARNING: Improper connection of the equipment grounding conductor
can result in a risk of electric shock. Check with a qualified electrician
or serviceman if you are in doubt as to whether the appliance is
properly grounded.
Do not modify the plug provided with the appliance - if it will not fit the
outlet, have a proper outlet installed by a qualified electrician.
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS) (208V & 240V MODELS)
Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block.
Connect Neutral line to center screw (N) of terminal block.
POWER SUPPLY CORD 3#10
AWG MINIMUM COPPER
CONDUCTORS
REAR
HOT WIRE
GREEN
GROUNDING
SCREW
GROUND
STRAP
L 1 L 2N
208V or 240V
FRONT
INSIDE TOP VIEW OF DRYER
HOT WIRE
WHITE
NEUTRAL
WIRE
30 AMP, 240V, WITH
TYPE UL RECOGNIZED
MINIMUM RATED 90°C
208 OR 240
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
(USE ONLY
30 AMP FUSES)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Properly strain relief the cord set or cable to the cable entry hole with
UL recognized strain relief.
Make sure cordset or the cable is away from the rotating drum.
Replace access panel.
Remove ground strap and discard. Rescrew green grounding screw in
place.
Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block.
Connect NEUTRAL line to center screw (N) of terminal block.
Attach ground wire of power supply to green grounding screw beside
terminal block.
GREEN OR YELLOW
GROUND WIRE
HOT WIRE
Properly strain relief the cord set or cable to the cable entry hole with
UL recognized strain relief.
Make sure cordset or the cable is away from the rotating drum.
Replace access panel.
FOR FOUR-WIRE SUPPLY
POWER SUPPLY CORD 4 #10
REAR
GREEN
GROUNDING
SCREW
HOT WIRE
WHITE
NEUTRAL
WIRE
L 1 L 2N
208V or 240V
FRONT
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
AWG MINIMUM COPPER
CONDUCTORS, 30 AMP, 240V,
WITH CLOSED-LOOP TERMINALS
TYPE UL RECOGNIZED MINIMUM
RATED 90°C.
REMOVE GROUND
STRAP AND DISCARD
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
30 AMP FUSES)
208 OR 240
(USE ONLY
3 WIRE RECEPTACLE
(10-30R)
Typical 30 amp receptacle for use where
local codes permit use of flexible type
power supply cord (pigtail).
PAGE 2
G
4-WIRE RECEPTACLE
Typical 30 amp receptacle for use
where local codes permit use of
flexible type power supply
cord (pigtail).
X
W
Y
(14-30R)
Typical 30 amp cord assembly for
use where local codes do not
permit grounding through
neutral.
4-CONDUCTOR CORD
ASSEMBLY ( Type ST Cable)