INSTALLATION INSTRUCTIONS (USA only)
MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instruc-
tions for local inspector’s use.
IMPORTANT- Observe all govern-
ingcodes and ordinances.
Note to Installer - Be sure to leave these instruc-
tions with the customer.
Note to Customer - Keep these instructions with
your Use and Care Book for future reference. Before the old dryer is removed from service or
discarded, remove the dryer door. Service information and the wiring diagram are
located in the control console. Do not allow children on or in the appliance. Close
supervision of children is necessary when the appliance is used near children. Install the dryer where the temperature is above
50°F for satisfactory operation of the dryer control system.
WARNING
To reduce the risk of severe injury or death, follow all installation
instructions.
Clothes dryer installation must be performed by a qualified installer. Install the clothes dryer according to these instructions and in
accordance with local codes. This dryer must be exhausted to the outdoors.
Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors. DO NOT install a clothes dryer with flexible plastic ducting
materials. If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 4 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire. Do not install or store this appliance in any location where it
could be exposed to water and or weather. Save these instructions. (Installers: Be sure to leave these
instructions with the customer).
RISK OF FIRE
DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL
This dryer must be connected to an individual branch circuit of proper voltage and frequency as specified on Rating Plate (located inside dryer
door) with no other appliances or fixtures attached. EXCEPTION:
A 120V receptacle is located on the back on the dryer and is available only for use with a washer that is affixed to the dryer with a WDF-85 kit. It may
not be used for any other appliance or any conditions other than slated above (208 & 240V models only). Branch circuit must be protected by the required time-delay fuses or circuit brackers 208V or 240V installation - 30 amps 120V installation 15 or 20 amps.
The electrical installation must conform to the national and local codes.
208V AND 240V MODELS ARE NOT APPROVED FOR120 V INSTALLATION.
TOOLS YOU WILL NEED
SLIP JOINT PLIERS
PHILLIPS SCREWDRIVER
STACKING KITS FOR DRYERS
(comes with individual installation instructions)
Over washer
- Use Wall Mount Kit WMK-35 or
- Stack Rack DSDR24 or
- Stack Rack DSR-24 For alcove and closet depth and width requirements see specific kit instructions All stacking kits are available from your local sales outlet.
FLAT BLADE SCREWDRIVER
MATERIALS YOU WILL NEED
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
DUCT TAPE
4" DIA. METAL
ELBOW
EXHAUST
HOOD
GLOVES
UNPACKING AND PREPARING FOR INSTALLATION
Prepare the area and exhaust for installation of new dryer. Check and ensure the existing external exhaust is clean and meets attached installation specifications. Remove the literature and accesories bag from the dryer drum. Place the literature in a convenient place. Using foam pads from dryer carton, turn dryer upside down as shown. Install knobs. For location, refer to “Use and Care” Book. Dryer is now ready to be mounted above washer using accessory kit. Remove the foam shipping pads from under dryer. Move the dryer to the desired location. Follow the steps in the following pages to connect the dryer to the external exhaust and power supply.
SAFETY
GLASSES
UL RATED 120/240V,30A WITH 3 OR 4 PRONGS.
3/4" STRAIN
RELIEF
UL RECOGNIZED
IDENTIFY THE PLUG TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD.
DRYER POWER
CORD KIT
(NOT PROVIDED
WITH DRYER)
PAGE 1
ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES
GROUNDING INSTRUCTIONS
The operating voltage (Volts), Amperage (Amps) and Frequency (Hz) of this dryer are indicated on the Rating Plate located to the right of the loading port. Connect this dryer to a circuit corresponding to that indicated on rating plate and protected by fuses or a circuit breaker in accordance with local codes. Use a power supply cord kit marked for use with clothes dryer. For 208V and 240V models, use a power supply cord kit marked for use with clothes dryers.
DO NOT USE EXTENSION CORD WITH THIS APPLIANCE
For alternate 208V or 240V power supply hook-up, proceed as follows:
Remove rear access panel. Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation.
WARNING: Appliance grounded to neutral conductor through a link. If used in a mobile home or if local codes do not permit grounding through neutral, a 4-conductor cord or cable assembly for use with clothes dryers must be used with the following specifications: Type St. Cable, 125/250 Min Volt, 30 Amp with closed-loop terminals and secured with a UL recognized strain relief. See manufacturer’s instructions Make sure screws on terminal block are tight.
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electrical current.
WARNING: Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
FOR THREE-WIRE SUPPLY
(208V & 240V MODELS) (208V & 240V MODELS)
Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block. Connect Neutral line to center screw (N) of terminal block.
POWER SUPPLY CORD 3#10
AWG MINIMUM COPPER
CONDUCTORS
REAR
HOT WIRE
GREEN GROUNDING SCREW
GROUND STRAP
L 1 L 2N
208V or 240V
FRONT
INSIDE TOP VIEW OF DRYER
HOT WIRE
WHITE NEUTRAL WIRE
30 AMP, 240V, WITH
TYPE UL RECOGNIZED
MINIMUM RATED 90°C
208 OR 240
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
(USE ONLY
30 AMP FUSES)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Properly strain relief the cord set or cable to the cable entry hole with UL recognized strain relief. Make sure cordset or the cable is away from the rotating drum. Replace access panel.
Remove ground strap and discard. Rescrew green grounding screw in place. Connect two (2) HOT lines to outer screws (L1 and L2) of terminal block. Connect NEUTRAL line to center screw (N) of terminal block. Attach ground wire of power supply to green grounding screw beside terminal block.
GREEN OR YELLOW GROUND WIRE
HOT WIRE
Properly strain relief the cord set or cable to the cable entry hole with UL recognized strain relief. Make sure cordset or the cable is away from the rotating drum. Replace access panel.
FOR FOUR-WIRE SUPPLY
POWER SUPPLY CORD 4 #10
REAR
GREEN GROUNDING SCREW
HOT WIRE
WHITE NEUTRAL WIRE
L 1 L 2N
208V or 240V
FRONT
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
AWG MINIMUM COPPER CONDUCTORS, 30 AMP, 240V, WITH CLOSED-LOOP TERMINALS TYPE UL RECOGNIZED MINIMUM RATED 90°C.
REMOVE GROUND
STRAP AND DISCARD
VOLT OPERATION
120/208 OR 120/240
VOLT SUPPLY
30 AMP FUSES)
208 OR 240
(USE ONLY
3 WIRE RECEPTACLE
(10-30R)
Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail).
PAGE 2
G
4-WIRE RECEPTACLE
Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail).
X
W
Y
(14-30R)
Typical 30 amp cord assembly for use where local codes do not permit grounding through neutral.