General Electric AZ65H12DAC Specsheet

AZ65H12DAC
SIDE
VIEW
Room
Cabinet
Outside
Grille
7-1/8
RAB71A = 16 RAB77A = 16-1/4
RAB71A = 20-7/8 RAB77A = 21
A
C
B
Zoneline RAC Wall Installation
GE Zoneline® Heat Pump Unit with Corrosion Protection, 230/208 Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.
GRILLE OPTIONS Stamped Aluminum Grille – RAG60 Exterior Architectural Louvers Durable Polycarbonate: RAG61 (Beige) RAG63 (Dark Brown) RAG62 (Maple) Extruded Aluminum Architectural Grille – RAG67
RETROFIT KITS: RAK40 – Deflector Kit to adapt chassis for use with existing (non-GE) exterior louvered grilles.
DUCTED APPLICATIONS AZ45 and AZ65 Series can be used with ductwork to heat or cool more than one room. RAK6053 Duct Adaptor is applied to the top of case over the air discharge. RAK601B Duct Extension is applied to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum recommended straight distance of 15 feet in one direction.
ELECTRICAL CONNECTION 230/208 volt units may be plugged into a receptacle. See Architects and Engineers Design Data Manual for electrical connection information including use of sub-base for direct connected units. Installation must comply with local electrical codes and regulations.
Power connection kits are required on all Zoneline chassis.
WALL CASE DIMENSIONS
RAB71B WALL SLEEVE
Heavy-gauge galvanized steel, with insulation. A – 42", B – 13-3/4", C – 16" Also available in 16" and 24" depths
RAB77B WALL SLEEVE
MAXIMUM CORD EXTENSION
21
58
A – 42-1/8", B– 13-7/8", C – 16-1/4"
WALL OPENING DIMENSIONS Add 1/4" to A and C dimensions for all cut-outs. RAB71B 16-1/4" Min. H x 42-1/4" Min. W
RAB77B 16-1/2" Min. H x 42-3/8" Min. W Molded SMC fiberglass-reinforced polyester compound.
AZ45/65 HEATER KW 230/208
VO LT
Power Connection Kit
Total Watts 2410/1990 3420/2830 483 0/3990 2430/2020 3450/2860 4860/4020
Heater Watts 2400/1960 3400/2780 4800/3930 2400/1960 3400/2780 4800/3930
Heater BTU 8100/6600 11600/9400 16300/13400 8100/6600 11600/9400 16300/13400
Total Amps 10.5/9.6 14. 9/13.6 21.0/19.2 10.6/9.7 15.1/13.8 21.2/19.3
Min Circuit 15 20 30 15 20 30
Recommended Protective Device
LINE CORD (P), DIRECT (D) AND SUB-BASE CONNECTED UNITS 7K/9K 12K/15K
RAK315P RAK315D RA K204D15C
15 amp time­delay fuse or breaker
RAK320P RAK320D RAK204D20C
20 amp time­delay fuse or breaker
RAK330P RAK330D RAK204D30C
30 amp time­delay fuse or breaker
RAK315P RAK315D RA K204D15C
15 amp time­delay fuse or breaker
RAK320P RAK320D RAK204D20C
20 amp time­delay fuse or breaker
RAK330P RAK330D RAK204D30C
30 amp time­delay fuse or breaker
For more information, please visit our website at zoneline.com or call 888.231.2548.
Speci fication Revise d 7/16
AZ65H12DAC
GE Zoneline® Heat Pump Unit with Corrosion Protection, 230/208 Volt
FEATURES AND BENEFITS
Cooling capacity - 11,900/11,800 BTU
Energy efficiency - 11.7/11.7 EER
Dehumidification - 3.7 pints/hour
Reverse heat cycle - 10,400/10,300 BTU
Heat pump efficiency - 3.6/3.6 COP
Indoor fan CFM (high/low) - 449/300
Fresh air vent CFM (fully open high fan) - 45
Quiet operation - Baked-on mastic sound barrier, cross flow blower and two DC fan motors create less noise to ensure comfort
Corrosion resistant - Extends life of the unit in sea coast areas/corrosive environments
Heat & Freeze Sentinels - Keeps the room from overheating or freezing
Boost heat option - Provides supplemental resistance heat in heat pump mode
Electronic temperature limiting - Prevents expensive over-cooling or over-heating of the room
Electronic touch controls with LED display
R-410A refrigerant
SMC base pan
Speci fication Revise d 7/16
Loading...