HygroGuard MMY2650
General Eastern
Trace Moisture Analyzer
Features
• Optional analog input for pressure compensation
or analog transmitter (voltage or current)
• One, two or three analog outputs; 0/4 to 20 mA or
0/1 to 5 VDC
• Three congurable relay outputs plus system
alarm relay
• Two line LCD and ve push button user interface
• RS485 serial output
• Full complement of pre-programmed moisture
measurement units
The HygroGuard MMY2650 is a moisture analyzer
designed to operate with the GE DY5 or DY55
planar gold aluminum oxide dew point sensor. The
unit oers an optional input that can be used for
pressure compensation, an external temperature
probe, or other analog transmitter. The standard
product comes with one current output (0/4 to
20 mA), a system alarm relay, and three adjustable
relays, all with single-pole double-throw 2.5 A
contacts, selectable failsafe mode, and adjustable
hysteresis. One or two additional analog outputs are
available. A display and ve push buttons from the
user interface for data display, unit selection, output
ranges, alarm setpoints and special functions.
The HygroGuard MMY2650 is available in both wall
mount and panel mount congurations. When used
with the DY5 dew point probe, the system is capable
of providing dew point readings in the range of
-112°F to 68°F (-80°C to 20°C) dew point over a
temperature range of -4°F to 140°F (-20°C to 60°C).
When congured with approved Zener Barriers the
model DY5xx probe is approved as intrinsically safe
for use in hazardous (classied) locations.
g
MMY2650 Specications
Standard Inputs
Two (moisture and temperature) from DY5 probe,
connects up to two DY55 probes.
Optional Input
For pressure transducer providing live pressure
compensation or monitoring one other analog
transmitter. Signals: 0/1 to 5 V, 0/4 to 20 mA loop
powered, or 4 to 20 mA/source.
Moisture Probe
Interconnects with DY5 probe (US) or DY55 (European)
probe
User Interface
Five push-buttons, easy conguration using a matrix
Display
Alphanumeric LCD displays measured value with units
of measure, matrix location programming instructions,
error indication and error codes; user selectable
scanning feature alternating the display every ve
seconds through active channels (three maximum)
European Compliance
Complies with EMC directive 2004/108/EC and
LVD 2006/95/EC
Digital Outputs
Four relays (SPDT dry contacts rated at 250 VAC, 2.5 A,
PCAC = 300 VA, cos phi > 0.7, PDC 100 W, 100 VDC). One
relay is system alarm. Three relays are congurable to any
input; failsafe mode: energized/de-energized selectable.
programmable hysteresis; high/low alarm selectable
Serial Output
RS485, streaming data, update rate once per second
Program
Non-volatile memory
Units Of Measure (Moisture)
Dew point °C, °F, ppmv (requires pressure measurement
or programmed constant), lb/MMSCF, g/m3, g/kg,
vapor pressure in hPa, or mmHg, %RH, process
pressure calculated dew point °C, °F (needs pressure
measurement using the optional input for live calculation
or pressure constant)
Units of Measure (DewPoint)
°F, °C, instrument range -202°F to 86°F (-130°C to 30°C)
Units of Measure (Pressure)
Optional input used with a pressure transducer to
selected unit; bara, barg, psia, psig, hPaa, hPag
Analog Outputs
Three, assigned to input 1, 2 and 3, 0/4 to 20 mA, load
resistance <500 ohms, 0/1 to 5 V, source resistance
249 ohms, user selectable range, user selectable
condition in case of error to 110%, -10% or hold at last
measured value
Data
EEPROM
Operating/Storage Temperature
14°F to 122°F (-10°C to 50°C)
Supply Voltage
90 to 240 VAC, optional 18 to 36 VDC
Power Consumption
5.8 VA for line voltage units, 2.2 W for DC powered units
Enclosures
Wall Mount: Type 12, Type 4X, Type 7, and Panel Mount.
Cable Entry
Metric cable gland M12, 2x M16, M20
Weight
2.2 lb (1 kg)