General Climate GC/CU-S24HR, GC/CU-S30HR, GC/CU-S36HR, GC-S24HR, CU-S24HR Service Manual

...
www.generalclimate.com Wall-Mounted Split Type
Service manual Room Air Conditioner
Split Wall-Mounted Type
GC/CU-S24HR GC/CU-S30HR GC/CU-S36HR
www.generalclimate.com Wall-Mounted Split Type
Content
1. Precaution 1
1.1 Safety Precaution 1
1.2 Warning 1
2. Function 3
3. Dimension 5
3.1 Indoor unit 5
3.2 Outdoor unit 6
4. Specification 7
5. Refrigerant cycle diagram 8
6. Operation limits 9
6.1 Cooling operation 9
6.2 Heating operation 9
7. Schematic diagram and Wiring diagram 9
7.1 Schematic diagram 10
7.2 Wiring diagram 11
8. Installation details 13
8.1 Wrench torque sheet for installation 13
8.2 Connecting the cables 13
8.3 Pipe length and the elevation 13
8.4 Air purging of the piping and indoor unit 14
8.5 Pumping down (Re-installation) 15
8.6 Re-air purging (Re-installation) 16
8.7 Balance refrigerant of the 2-way, 3-way valves 17
8.8 Evacuation 18
8.9 Gas charging 19
9. Capacity table 20
9.1 GC/GU-S24HR 20
9.2 GC/GU-S30HR 21
9.3 GC/GU-S36HR 22
10. Electronic function 23
10.1 Electronic control working environment 23
10.2 Proper symbols and their meaning 23
10.3 Function 24
10.4 Protection 24
10.5 Fan only mode 24
10.6 Cooling mode 24
10.7 Dehumidifying mode 25
10.8 Heating mode 25
10.9 Defrosting mode(available for heating mode) 27
10.10 Auto mode 28
10.11 Force cooling function 28
10.12 Sleep mode 28
www.generalclimate.com Wall-Mounted Split Type
10.13 Auto restart function 29
11. Model and Parameters 30
12. Troubleshooting 31
12.1 Display board 31
12.2 Troubleshooting 32
12.3 Diagnostic chart 33
12.4 Resetting phenomenon often occurs during operation. 34
12.5 Operation lamp flashes and Timer lamp off. 34
12.6 Operation lamp flashes and Timer lamp on. 34
12.7 Operation lamp off and Timer lamp flashes 35
12.8 Operation lamp on and Timer lamp flashes 35
12.9 Operation lamp flashes, Timer lamp flashes . 35
13. Characteristic of temperature sensor 36
www.generalclimate.com 1 Wall-Mounted Split Type
1. Precaution
1.1 Safety Precaution
n To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. n Before service unit, be sure to read this service manual at first.
1.2 Warning
Ø Installation
n Do not use a defective or underrated circuit breaker.
Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
n For electrical work, contact the dealer, seller, a
qualified electrician, or an Authorized service center.
Do not disassemble or repair the product, there is risk of fire or electric shock.
n Always ground the product.
There is risk of fire or electric shock.
n Install the panel and the cover of control box
securely.
There is risk of fire of electric shock.
n Always install a dedicated circuit and breaker.
Improper wiring or installation may cause fore or electric shock.
n Use the correctly rated breaker of fuse.
There is risk of fire or electric shock.
n Do not modify or extend the power cable.
There is risk of fire or electric shock.
n Do not install, remove, or reinstall the unit by
yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
n Be caution when unpacking and installing the
product.
Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator.
n For installation, always contact the dealer or an
Authorized service center.
There is risk of fire, electric shock, explosion, or injury.
n Do not install the product on a defective installation
stand.
It may cause injury, accident, or damage to the product.
n Be sure the installation area does not deteriorate
with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
n Do not let the air conditioner run for a long time
when the humidity is very high and a door or windows is left open.
Moisture may condense and wet or damage furniture.
n Take care to ensure that power cable could not be
pulled out or damaged during operation.
There is risk of fire or electric shock.
n Do not place anything on the power cable.
There is risk of fire or electric shock.
n Do not plug or unplug the power supply plug during
operation.
There is risk of fire or electric shock.
n Do not touch (operation) the product with wet hands.
There is risk of fire or electric shock.
n Do not place a heater or other appliance near the
power cable.
There is risk of fire and electric shock.
n Do not allow water to run into electric parts.
It may cause fire, failure of the product, or electric shock.
n Do not store or use flammable gas or combustible
near the product.
There is risk of fire or failure of product.
n Do not use the product in a tightly closed space for a
long time.
Oxygen deficiency could occur.
n When flammable gas leaks, turn off the gas and
open a window for ventilation before turn the product on.
Do not use the telephone or turn switches on or off. There is risk of explosion or fire.
n If strange sounds, or small or smoke comes from
product. Turn the breaker off or disconnect the power supply cable.
There is risk of electric shock or fire.
n Stop operation and close the window in storm or
hurricane. If possible, remove the product from the window before the hurricane arrives.
www.generalclimate.com 2 Wall-Mounted Split Type
There is risk of property damage, failure of product, or electric shock.
n Do not open the inlet grill of the product during
operation. (Do not touch the electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock, or product failure.
n When the product is soaked (flooded or submerged),
contact an Authorized service center.
There is risk of fire or electric shock.
n Be caution that water could not enter the product.
There is risk of fire, electric shock, or product damage.
n Ventilate the product from time to time when
operating it together with a stove, etc.
There is risk of fire or electric shock.
n Turn the main power off when cleaning or
maintaining the product.
There is risk of electric shock.
n When the product is not be used for a long time,
disconnect the power supply plug or turn off the breaker.
There is risk of product damage or failure, or unintended operation.
n Take care to ensure that nobody could step on or fall
onto the outdoor unit.
This could result in personal injury and product damage.
Ø CAUTION
n Always check for gas (refrigerant) leakage after
installation or repair of product.
Low refrigerant levels may cause failure of product.
n Install the drain hose to ensure that water is drained
away properly.
A bad connection may cause water leakage.
n Keep level even when installing the product.
To avoid vibration of water leakage.
n Do not install the product where the noise or hot air
from the outdoor unit could damage the neighborhoods.
It may cause a problem for your neighbors.
n Use two or more people to lift and transport the
product.
Avoid personal injury.
n Do not install the product where it will be exposed to
sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
Ø Operational
n Do not expose the skin directly to cool air for long
periods of time. (Do not sit in the draft).
This could harm to your health.
n Do not use the product for special purposes, such
as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
n Do not block the inlet or outlet of air flow.
It may cause product failure.
n Use a soft cloth to clean. Do not use harsh
detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
n Do not touch the metal parts of the product when
removing the air filter. They are very sharp.
There is risk of personal injury.
n Do not step on pr put anything on the product.
(outdoor units)
There is risk of personal injury and failure of product.
n Always insert the filter securely. Clean the filter
every two weeks or more often if necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
n Do not insert hands or other object through air inlet
or outlet while the product is operated.
There are sharp and moving parts that could cause personal injury.
n Do not drink the water drained from the product.
It is not sanitary could cause serious health issues.
n Use a firm stool or ladder when cleaning or
maintaining the product.
Be careful and avoid personal injury.
n Replace the all batteries in the remote control with
new ones of the same type. Do not mix old and mew batteries or different types of batteries.
There is risk of fire or explosion.
n Do not recharge or disassemble the batteries. Do not
dispose of batteries in a fire.
They may burn of explode.
n If the liquid from the batteries gets onto your skin or
clothes, wash it well with clean water. Do not use the remote of the batteries have leaked.
The chemical in batteries could cause burns or other health hazards.
www.generalclimate.com 3 Wall-Mounted Split Type
2. Function
T
he function will be
operate in any operation
Indoor unit
Operation ON/OFF by remote controller
Room temp
erature sensor.
Pipe temperature sensor.
Sensing by room temperature
Maintain the room temperature in accordance with the setting temperature.
Room temperature control
Indoor fan is delayed for 5 sec at the starting.
Starting temperature control
Restarting is for approx.
3
minutes..
Time Delay Safety control
High
, med, low, breeze.
Indoor fan speed control
Light up in the LED (LCD) for each operation mode.
The unit will decide the louver direction according to operation mode.
Two-direction air vane
The fan is turn to low speed
(cooling/heating).
The unit will be turn off after seven hours.
Sleep mode auto control
The function is usually used in rainy days in
springtime or damp areas.
Independent dehumidification
Operation indication Lamps (LED)
The louver can be
set at the desired position or swing up and
down automatically
Air flow Direction control
The unit can be change by the room temperature.
Auto mode
Easy clean panel
Flexible wiring connection
Defrost mode
Temp. Compensation
P
revent the cold wind at
the beginning of unit start.
Anti-cold function
Auto-restart function
Self-diag. function
www.generalclimate.com 4 Wall-Mounted Split Type
T
he unit can operate in cooling mode at low
ambient
temperature conditions.
The unit has
3 mins delay between
continuously
ON/OFF
operations
.
Outdoor unit
Power relay control
Low ambient kit
B
ird tail propeller fan makes the outdoor unit run more quietly.
Low noise air flow system
T
he hydrophilic fin can improve the heating efficiency at operation mode.
Hydrophilic aluminum fin
I
t is only operated in t
he heating operation mode except defrosting
operation
.
Discharge pipe temperature protect
Anti-rust cabinet
Valve protection cover
4 way valve control
Made from electrolytic zinc steel shee
t and anti
-
rust coated components.
I
t protects the valves and prevents water from dripping.
www.generalclimate.com 5 Wall-Mounted Split Type
3. Dimension
3.1 Indoor unit
Dimension Mode
WHL
24K1080330222 30K1080330222 36K1250325230
www.generalclimate.com 6 Wall-Mounted Split Type
3.2 Outdoor unit
Dimension Mode
WHDL1L2L3
24K845695335
560
360
735
30K845695335
560
360
735
36K895860302
560
360
735
www.generalclimate.com 7 Wall-Mounted Split Type
4. Specification
GC/GU-S24HRGC/GU-S30HRGC/GU-S36HR
Ph-V-Hz
1, 220-240V~,50Hz1, 220-240V~,50Hz
1, 220-240V~, 50Hz
Capacity Btu/h
2400028000
35000
Input W
27503200
4120
Rated current A
12,515
18,6
EER Btu/w.h
8.7, 2.68,8
8,5
Capacity Btu/h
2700030000
38000
Input W
27503100
4100
Rated current A
12,514,5
18,5
COP W/W
2,99,79,3
A
162032
A
5076150
Model
QP407PT24CZR34KH-PFJ-522
ZR47K3-PFJ-522
Type
RotaryScroll
SCROLL
Brand
LGCopeland
COPELAND
Capacity Btu/h
2340028800
39000
Input W
23172520
3510
Rated current(RLA) A
10,112,1
19,3
Locked rotor Amp(LRA) A
5476
114
Thermal protector
InternalInternal15HM1637
Capacitor uF
4550
60uF/≥400VAC
Refrigerant oil ml
65012421240
Model
YDK36-4GYDK36-4GYDK50-4E
Brand
WellingWellingWelling
Input W
65/63/6068/65/62
85/80/77
Capacitor uF
2μF/450V3
μ
F/450V3
Speed(hi/mi/lo) r/min
1050/950/8501150/1050/9501260/1150/990
m3/h
1050/950/8501150/1050/9501350/1200/1050
dB(A)
43/40/3747/44/41
49/46/42
Model
YDK53-6KYDK53-6KYDK100-6
Brand
WellingWellingWelling
Input W
130140169
Capacitor uF
3,53,55
Speed r/min
800800900
m3/h
250025003000
dB(A)
56
58
59
g
R22/1900R22/24502450
MPa
2,62,62,6
Liquid side/ Gas side mm
Ф
9.53/Ф16.0
Ф
9.53/Ф16.0
Φ
9.52/Φ16
Max. refrigerant pipe length m
202025
Max. difference in level m
101010
17-3017-3017-30
-7 - 45-7 - 45-7 - 45
m
2
40~5650~6860~78
Operation temp Ambient temp Application area
Outdoor noise level Refrigerant type R410A Design pressure
Refrigerant piping
Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo)
Outdoor fan motor
Outdoor air flow
Max. current Starting current
Compressor
Indoor fan motor
Model
Power supply
Cooling
Heating
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement.
www.generalclimate.com 8 Wall-Mounted Split Type
5. Refrigerant cycle diagram
Ø Cooling only
Ø Heat pump mode
www.generalclimate.com 9 Wall-Mounted Split Type
6. Operation limits
6.1 Cooling operation
Outdoor unit air temp. DB
Indoor air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage.
6.2 Heating operation
Indoor air temp. DB
Outdoor unit air temp. DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage.
7. Schematic diagram and Wiring diagram
www.generalclimate.com 10 Wall-Mounted Split Type
7.1 Schematic diagram
www.generalclimate.com 11 Wall-Mounted Split Type
7.2 Wiring diagram
7.2.1 Heating mode
GC/GU-S24HR, GC/GU-S30HR
A1
A2
www.generalclimate.com 12 Wall-Mounted Split Type
GC/GU-S36HR
A1A2
www.generalclimate.com 13 Wall-Mounted Split Type
8. Installation details
8.1 Wrench torque sheet for installation
Torque
mminchKg.m
φ6.351/41.8 φ9.523/84.2
φ12.71/25.5 φ15.885/86.6 φ19.053/46.6
Outside diameter
8.2 Connecting the cables
The power cord of connect should be selected according to the following specifications sheet.
Unit24K30K36K
mm22,52,52,5
Grade
8.3 Pipe length and the elevation
Standard
length
Max.Max.Additional
(m)ElevationElevationrefrigerant
Btu/h
GAS
LIQUID
B (m)A
(m)
(g/m)
24K
5/8’’ (φ15.88)
3/8’’ (φ9.52)
51020655/8’’ (φ15.88)
3/8’’ (φ9.52)
51530653/4’’ (φ19.05)
3/8’’ (φ9.52)
51530
65
Pipe size
30K~36K
Capacity
Caution: Capacity is base on standard length and maximum allowance length is base of reliability. Oil trap should be install per 5-7 meters.
In case that more than 5m.