General Climate ac-n9krh Instruction Manual

PORTABLE AIR CONDITIONER
Instruction Manual
AC-N6KM AC-N6KR AC-N6KMH AC-N6KRH AC-N9KM AC-N9KR AC-N9KMH AC-N9KRH AC-N12KM AC-N12KR AC-N12KMH AC-N12KRH
Read and retain these instructions for future reference
Downloaded from AC-Manual.com Manuals
SPECIFICATION
Model no.
Cooling capacity
Heating capacity
Power/Ampere consumption for cooling* Power/Ampere consumption for heating* Air volume (max. speed) Humidity removal capacity Recommended room size Power supply 230V/50Hz/1phase Compressor rotary Refrigerant R-22 or R-407C (Please refer to the rating label.) Refrigerant load* Fan speed 2 Timer mechanical switch 1 ~ 8 hours
Thermostat 18 ~ 32oC Net Weight 27 kgs 29 kgs 31 kgs Dimension 400 x 377 x 750 mm (WxDxH)
REMARK:
1. Heating capacity is only for the model with heating function, i.e. model no. AC-N6KMH, AC-N6KRH, AC-N9KMH, AC-N9KRH, AC-N12KMH, AC-N12KRH.
2. The data marked with '*' may vary for technical reasons: for greater precision, please refer to the rating label placed at the back of the unit.
3. Measuring condition for above is: Cooling - RT27
Heating - RT20
*RT means room temperature, RH means room humidity.
AC-N6KM, AC-N6KMH
AC-N6KR, AC-N6KRH
6000 BTU/hr
1510 Kcal/hr
1758 watts
6800 BTU/hr
1700 Kcal/hr
2000 watts
AC-N9KM, AC-N9KMH
AC-N9KR, AC-N9KRH
9000 BTU/hr
2268 Kcal/hr
2637 watts 10000 BTU/hr 2520 Kcal/hr
2930 watts
AC-N12KM, AC-N12KMH
AC-N12KR, AC-N12KRH
12000 BTU/hr 3024 Kcal/hr
3529 watts 12500 BTU/hr 3150 Kcal/hr
3676 watts
530W/ 2.38A 830W/ 3.9A 850W/ 4.2A
630W/ 2.8A 910W/ 4.25A 960W/ 4.5A
440m3/h 470m3/h 520m3/h
21.6L/day 26.4L/day 31.2L/day
12m2 18m2 24m2
440 g 470 g 480 g
electronic switch 1~ 12 hours
O
C, RH60%
O
C, RH60%
1
Downloaded from AC-Manual.com Manuals
BEFORE USE
GENERAL SAFETY
ONLY USE IN THE UPRIGHT POSITION ON A FLAT LEVEL SURFACE AND AT LEAST 50cm FROM ANY OBJECTS (Fig 1 & 4).
DO NOT PLACE OBJECTS ON THE UNIT OR RESTRICT AIR INLET / OUTLET (FIG. 2).
CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN UNIT IS IN USE.
ELECTRICAL SAFETY
FOR INDOOR USE ONLY.
SWITCH OFF AND UNPLUG WHEN NOT
IN USE.
DO NOT USE IN HUMID OR WET ENVIRONMENTS (FIG 3)
DO NOT PULL THE UNIT ALONG BY THE CORD.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON, TO AVOID HAZARD.
FOR MAXIMUM EFFICENCY
Do not exceed the recommended room size 50m area)
Close doors and windows
Keep curtains of blinds closed during
the sunniest part of the day
Keep filters clean
Once room has reached the desired
conditions, reduce temperature and ventilation settings
3
(typically 20m2 floor
2
Downloaded from AC-Manual.com Manuals