PORTABLE AIR CONDITIONER
Instruction Manual
AC-N6KM AC-N6KR
AC-N6KMH AC-N6KRH
AC-N9KM AC-N9KR
AC-N9KMH AC-N9KRH
AC-N12KM AC-N12KR
AC-N12KMH AC-N12KRH
Read and retain these instructions for future reference
Downloaded from AC-Manual.com Manuals
![](/html/2d/2db4/2db489f679326431c796452b4e1c6d02cd65e1a765784230665cc4c6b2d33f80/bg2.png)
SPECIFICATION
Model no.
Cooling
capacity
Heating
capacity
Power/Ampere
consumption for
cooling*
Power/Ampere
consumption for
heating*
Air volume
(max. speed)
Humidity
removal
capacity
Recommended
room size
Power supply 230V/50Hz/1phase
Compressor rotary
Refrigerant R-22 or R-407C (Please refer to the rating label.)
Refrigerant
load*
Fan speed 2
Timer mechanical switch 1 ~ 8 hours
Thermostat 18 ~ 32oC
Net Weight 27 kgs 29 kgs 31 kgs
Dimension 400 x 377 x 750 mm (WxDxH)
REMARK:
1. Heating capacity is only for the model with heating function, i.e. model no.
AC-N6KMH, AC-N6KRH, AC-N9KMH, AC-N9KRH, AC-N12KMH, AC-N12KRH.
2. The data marked with '*' may vary for technical reasons: for greater precision,
please refer to the rating label placed at the back of the unit.
3. Measuring condition for above is: Cooling - RT27
Heating - RT20
*RT means room temperature, RH means room humidity.
AC-N6KM, AC-N6KMH
AC-N6KR, AC-N6KRH
6000 BTU/hr
1510 Kcal/hr
1758 watts
6800 BTU/hr
1700 Kcal/hr
2000 watts
AC-N9KM, AC-N9KMH
AC-N9KR, AC-N9KRH
9000 BTU/hr
2268 Kcal/hr
2637 watts
10000 BTU/hr
2520 Kcal/hr
2930 watts
AC-N12KM, AC-N12KMH
AC-N12KR, AC-N12KRH
12000 BTU/hr
3024 Kcal/hr
3529 watts
12500 BTU/hr
3150 Kcal/hr
3676 watts
530W/ 2.38A 830W/ 3.9A 850W/ 4.2A
630W/ 2.8A 910W/ 4.25A 960W/ 4.5A
440m3/h 470m3/h 520m3/h
21.6L/day 26.4L/day 31.2L/day
12m2 18m2 24m2
440 g 470 g 480 g
electronic switch 1~ 12 hours
O
C, RH60%
O
C, RH60%
1
Downloaded from AC-Manual.com Manuals
![](/html/2d/2db4/2db489f679326431c796452b4e1c6d02cd65e1a765784230665cc4c6b2d33f80/bg3.png)
BEFORE USE
GENERAL SAFETY
• ONLY USE IN THE UPRIGHT POSITION ON
A FLAT LEVEL SURFACE AND AT LEAST
50cm FROM ANY OBJECTS (Fig 1 & 4).
• DO NOT PLACE OBJECTS ON THE UNIT
OR RESTRICT AIR INLET / OUTLET (FIG. 2).
• CLOSELY SUPERVISE ANY CHILDREN
AND PETS WHEN UNIT IS IN USE.
ELECTRICAL SAFETY
• FOR INDOOR USE ONLY.
• SWITCH OFF AND UNPLUG WHEN NOT
IN USE.
• DO NOT USE IN HUMID OR WET
ENVIRONMENTS (FIG 3)
• DO NOT PULL THE UNIT ALONG BY THE
CORD.
• IF THE SUPPLY CORD IS DAMAGED, IT
MUST BE REPLACED BY AN ELECTRICIAN
OR SIMILARLY QUALIFIED PERSON, TO
AVOID HAZARD.
FOR MAXIMUM EFFICENCY
• Do not exceed the recommended
room size 50m
area)
• Close doors and windows
• Keep curtains of blinds closed during
the sunniest part of the day
• Keep filters clean
• Once room has reached the desired
conditions, reduce temperature and
ventilation settings
3
(typically 20m2 floor
2