GENERALAire 570 Installation Manual

Fresh Indoor Air Quality
R
570 SERIES
INSTALLER: PLEASE FILL OUT AND MAIL WARRANTY CARD AFTER INSTALLATION IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures exceed 150 degrees F. When wiring into a multi-speed blower circuit see Step 6.
INSTALLATION: The humidifier may be mounted with the 6" outlet to the right or left by inverting the cabinet and reversing the positions of the distributor trough and drain pan. The humidifier may be mounted on the warm or return air plenum with equal efficiency. See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:
1. 1/4" diameter plastic supply tubing or 1/4" copper supply tubing for hot water applications
2. 6" diameter galvanized by-pass pipe
3. electrical wire and wire nuts
4. current sensing relay (G.F. Model #GA50 suggested)
5. #8 self piercing sheet metal screws
1
WARM AIR
UP FLOW
3
3
RETURN AIR
DRAIN
GENERALAire AC SERIES
HIGH EFFICIENCY AIR CLEANER
R
WARM AIR
9-1/2”
6”
FLOW-THROUGH
BYPASS HUMIDIFIER
FOR INSTALLATION ON A VERTICAL
PLENUM SURFACE OF ANY
FORCED AIR FURNACE
RETURN AIR
DRAIN
DOWN FLOW
WARM AIR
8-7/8”
The General Aire model 570 may be installed on either the supply or return plenum of a forced air handling system. Select a location for the humidifier that allows for service and maintenance. Cut out a rectangle 8-7/8” wide by 9-1/2“ tall. Extend horizontal centerline of cut out to the adjacent plenum. Cut a 6” hole 10” to 15” from side of humidifier, on cabinet centerline, using connecting collar as guide. The bypass is reversible and can be mounted on the right or left side of the humidifier.
2
1
Humidifier is self retaining. Slide top side in first, then slide chassis down. Level chassis and install center screws. If by-pass pipe installs to opposite side of chassis, bend clip on chassis, remove side discharge, and reinstall discharge to opposite side of chassis. Install remaining four corner screws.
FORM NO. 570-18 (FILE 15018) REV. E
Connect by-pass pipe to collar and humidifier cabinet. Using holes at top and bottom of side panel discharge, pierce 2 self tapping screws through by-pass pipe.
4
COPPER TUBING
PLASTIC TUBING
2
Mount the self tapping saddle valve or code valve on either a cold or a hot water pipe. A side or top mount is best to avoid clogging from pipe sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper tubing requires a brass compression nut and brass sleeve. Plastic tubing requires a brass insert inside the tubing, a plastic sleeve on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT. INSTALLATION OF THIS SADDLE VALVE MUST MEET OR EXCEED LOCAL CODES AND ORDINANCES.
GCV3412 CODE VALVE INSTALLATION INSTRUCTIONS
Copper Pipe
1. Turn off water supply.
2. Clean pipe, fittings and valve with sandpaper or wire brush.
3. Apply a thin layer of flux to all surfaces to be soldered.
4. Assemble valve to pipe and/or fittings.
5. Cooling the valve by wrapping a wetted rag around the valve is optional.
6. Heat the joints with a torch. Apply solder to each joint. Continue to apply heat sufficient to keep solder liquid.
7. After solder has filled entire joint area, remove heat and allow joint to cool. Do not move or disturb.
8. Slide compression nut over 1/4” copper tube followed by compression sleeve.
9. Insert tube into valve fully and tighten nut.
10. Turn on water supply and check for leaks.
*CODE VALVE IS INCLUDED WITH AUTOMATIC MODELS ONLY
3/4” TEE
1/2” TEE
5
Connect 1/4" water supply tube to brass filter at inlet of solenoid. DO NOT USE PLASTIC TUBING IN CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT. IF USING PLASTIC TUBING, USE TUBE SUPPORT P189 AND PLASTIC COMPRESSION SLEEVE P190.
6
Turn damper knob to winter (open) position. Turn on water supply and check operation of humidifier. Set humidistat to a demand setting. With the furnace off, the solenoid valve should be closed. Start the furnace, the solenoid valve should open when the blower or burner circuit is energized. Check flow of water through distributor trough and evaporator pad. The standard GA4231 yellow orifice will supply approximately 3.5 GPH of water at a line water pressure of 60 psi. For low water pressures (20-40 psi) a larger orange orifice GA4299 is available to provide the same flow. Leave humidistat set at the recommended setting.
7
SNSR
HUM
AC N
AC L
SNSR
HUM
AC N
AC L
HUMIDISTAT
HUMIDISTAT
OUTDOOR TEMP. SENSOR
WIRE JUMPER
WIRE JUMPER
OUTDOOR TEMP. SENSOR
WIRE
JUMPER
727-58 24 V. TRANSFORMER
24 V. TRANSFORMER
ON-OFF SWITCH
FURNACE
CONTROL BOARD
C
24v. 60CY.
R
N
115v. (HOT) 60CY.
FURNACE
CONTROL BOARD
C
24v. 60CY.
HUM
ON-OFF SWITCH
W
W
FURNACE
BOARD
FURNACE
BOARD
(HOT)
ACC EAC
24v. 60CY.
24V. SOLENOID VALVE
24V. SOLENOID VALVE
24V. SOLENOID VALVE
24V. SOLENOID VALVE
C
115v. 60CY.
7A
7C
7E
7G
SNSR
HUM
AC N
AC L
SNSR
HUM
AC N
AC L
HUMIDISTAT
Connect drain hose to 1/2" spout on humidifier cabinet using hose clamp. Run 1/2" hose to suitable drain such as floor drain, sewer or laundry sink. Be sure hose has continuous slope and is not kinked at any point.
L2
115v. 60CY.
(HOT)
L1
FURNACE
COMMON LEAD
C
(HOT)
L2
115v. 60CY.
(HOT)
L1
FURNACE
COMMON LEAD
C
(HOT) 115v. 60CY.
24V. SOLENOID VALVE
7B
C
MULTI SPEED
HI
BLOWER
LO
MOTOR
115v. 60CY.
7D
24V. SOLENOID VALVE
7F
C
MULTI SPEED
HI
BLOWER
LO
MOTOR
OUTDOOR TEMP. SENSOR
WIRE
JUMPER
727-58 24 V. TRANSFORMER
24V. SOLENOID VALVE
OUTDOOR TEMP. SENSOR
WIRE
JUMPER
727-58 24 V. TRANSFORMER
C
12500 AIR
PRESSURE SWITCH
24V. SOLENOID VALVE
24 V. TRANSFORMER
NO
C 12500 AIR
PRESSURE SWITCH
ON-OFF SWITCH
24 V. TRANSFORMER
HUMIDISTAT
ON-OFF SWITCH
NO
ON-OFF SWITCH
CURRENT
SENSING
RELAY
ON-OFF SWITCH
CURRENT
SENSING
RELAY
GA50
GA50
7H
7A-7D Electronic Humidistat
7A - To furnace control board 24 volts 7B - To constant power using 24V transformer and pressure switch 7C - To furnace control board 115 volts with 24V transformer 7D - To constant power using 24V relay and current sensing relay
7E-7H Manual Humidistat
7E - To furnace control board 24 volts 7F - To constant power using 24V transformer and pressure switch 7G - To furnace control board 115 volts with 24V transformer 7H - To constant power using 24V relay and current sensing relay