GeneralAire 1300 Installation, Operation & Maintenance Manual

Page 1
GeneralAire®
Installation, Operation & Maintenance Manual
07 / 2011
Model 1300 Dehumidifier
Page 2
TableofContentsPage233458999101112SafetySpecificationsOperationInstallationElectricalInitialSetUpMaintenanceWiringDiagramDimensionsPartsListingWarrantyTroubleshootingSafetyInstructionsReadandsavetheseimportantsafetyinstructionsTheinstallationoperationandmaintenanceinstructionsmustbecarefullyfollowedwhileinstallingandoperatingthedehumidifierProperadherencetotheseinstructionsisessentialtoobtainmaximumbenefitfromyourdehumidifierDANGER120voltsmaycauseseriousinjuryfromelectricshockDisconnectelectricalpowerbeforeinstallationorservicingIfusednearapoolorspabecertainthereisnochancetheunitcouldfallintothewaterorbesplashedUnitmustbegroundedelectricallyincompliancewiththeNationalElectricCodeandlocalcodesFailuretocomplywiththiswarningcouldresultinseverepersonalinjuryordeathWARNINGCAUTIONThisdehumidifiermustbeinstalledandservicedbyaqualifiedheatingventilationandairconditioningprofessionalincompliancewithalllocalandnationalcodesImproperinstallationadjustmentalterationserviceormaintenancecancauseinjuryorpropertydamageHandleunitwithcareusingadequatemanpowerorequipmenttoliftandavoidinjurytopersonnelandorequipmentFailuretoinstallthisdehumidifierincompliancewiththeinstructionscontainedhereincouldresultinunsatisfactoryoperationandordamagetotheproductThisunitisdesignedtobeinstalledindoorsinanareaprotectedfromrainormoistureItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageForproperoperationexternalstaticpressuresacrosstheunitmustnotexceed6incheswcForprotectionofthecompressoritmustbetransportedandinstalledinanuprightpositionIftheunitwasshippedorstoredonitssidea24hoursettlingperiodintheuprightpositionisrequiredbeforerunningtheunitforthefirsttimeTemporarystoragemustbeindoorsuprightintheoriginalcartonandcompletelyshieldedfromprecipitation2
Page 3
SpecificationsCapacity130Pintsperday@BOOFDBT60RHUnitPowerSupply115VoltsSinglePhase60HzMinimumCircuitAmpacity131MaximumFuse1SampOverallLength30includesductcollarsDimensionsCabinetLength24CabinetWidth25WCabinetHeight20YWeight150PoundsCompressorRotaryType1070Watts95RLA61LRARefrigerantR22FanMotor1HP11SFLAAirFlow400CFM@6incheswESPFilterWashableNylon17x23CabinetInsulationTypeEPDM1thickRValue42DuctConnections8diameterDrainConnectionsJAPrimaryandSecondaryDrainPanStainlessSteelAllspecificationsandperformancedataaresubjecttochangewithoutnoticeOperationThefunctionoftheDH130AdehumidifieristoreducetheindoorhumiditylevelsandincreasecomfortItisahighcapacitydehumidifierabletoremove130pintsofwaterperdayBOOFDBT60RHAhumiditysensordehumidistatsenseswhentherelativehumidityRHisabovethesetpointexample50RHandsignalsthedehumidifiertooperateuntiltherelativehumiditylevelhasbeenloweredtothesetpointIftheroomthermostatcallsforheatingorcoolingthedehumidifierwillstopandwillnotoperateWhentheroomthermostatissatisfiedandtheheatingorairconditionerisstoppedthedehumidifierwillresumeoperationiftherelativehumidityRHisabovethesetpointIfthedehumidistatissatisfiedwhentheheatingorcoolingceasesthedehumidifierwillremainstoppedIftheswitchonthethermostatfortheheatingorairconditioningsystemisplacedintheOFFpositionthedehumidifierwillstilloperateiftherelativehumidityisabovethedehumidistatsetpointToturnoffthedehumidifiermovethedehumidistatdialtotheOFFpositionTurningthedehumidifieroffisnotrecommendedasitreducestheeffectivenessoftheoveralldehumidificationsystemControlsUnitMountedDehumidistatTheunitiscontrolledbytheintegralcontrolsystemwhichoperatestheinternalfanapproximately15minuteseachhourtosampletheairinthesystemTheairsamplepassesovertheunitmountedhumiditysensorwhichshouldbesetatapproximatelymidlevelAfterathreeminutedelayifthehumiditylevelinthesampledairisgreaterthanthesetpointthedehumidifierwillturnonThedehumidifierwilloperateuntilthehumiditylevelreachesthehumiditysensorsetpointOptionalWallControlledOehumidistatWhenthewallcontrolleddehumidistatisusedtheunitmountedcontrolmustbesettothelowestrelativehumidityRHsettingandneverreadjustedThewallcontrolleddehumidistatshouldbesetinthecomfortareaofapproximately50relativehumidityWhenthedehumidistatsensesthattherelativehumidityinthespaceisaboveitssetpointanelectricalcontactwithinthedehumidistatclosescausingthedehumidifiertostartTheunitdehumidifieroperatesuntiltherelativehumidityhasbeenloweredtothesetpoint3
Page 4
FrostControlInsomecasesofprolongedoperationoriftheconditionedspaceisrelativelycoolfrostwillaccumulateonthecoilIcemayeventuallycoverthecoilblocktheairflowandstopproperoperationIfthecoilbecomesunacceptablycoldforatleasttenminutesasensormountedonthecoilwillstopthecompressorTopreventfrostbuildupbeyondanacceptablelevelthefanwillcontinuetooperatetomeltanyaccumulatediceOncetheicehasmeltedandthecoiliswarmthecompressorwillrestartandthedehumidificationprocesswillresumeFloatSwitchInadditiontotheprimaryandsecondarycondensatedrainlinestheDH130AisequippedwithafloatswitchIfthedrainlinesshouldbecomecloggedorrestrictedoverflowofwaterwilloccurThisswitchdisablesthecompressorandstopswaterproductionOncetheblockagehasbeenclearedtheswitchwillallowtheunittoreturntonormaloperationInstallationlocationWhenchoosinganinstallationlocationconsidertheaccessibilityforservicecondensatedrainavailabilityandpowerconnectionTheproperlocationisveryimportantasitwilldeterminetheoveralllengthoftheconnectionductsLocatetheunitascloseaspossibletotheindoorportionoftheheatingorairconditioningsystemThedehumidifiermaybeplacedabovebeloworlevelwiththeheatingorairconditioningsystemPlacetheunitinalocationthatwillallowaminimumof22clearanceforfilterremovalandserviceaccessThisclearanceisrequiredononlyonesideoftheunitsincethefilterisremovablefromeithersideAllowadequateclearancetowallsforunitserviceThishumidifierisdesignedtobeinstalledindoorsinaspacethatisprotectedfromrainormoisture5upendedunitutiljzjngoptionalhangingkitMountingThedehumidifiermaybemountedonaflatsurfaceorsuspendedDonotmounttheunitdirectlyonstructuralmembersIfmountedonaflatsurfaceusethefourrubbermountingfeetprovidedTominimizeunwantedvibrationselectalevelmountingsurfaceAdjustthemountingfeettocompensateforanysurfaceirregularitiesMakecertainthattheunitissittingonallfourmountingfeetTosuspendtheunitaseparatehangerkitHD14isrequiredThiskitconsistsoffourbracketsandfourrubberisolatorsThreadedrodsorothermeansofsuspensionmustbeprovidedbytheinstallerandmustbeselectedbasedontheunitweightlS0IbsandincompliancewithlocalcodeslIIiThisunitisequippedwithaprimaryandsecondarydrainalongwithafloatswitchtopreventoverflowofwaterfromtheunitItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageCondensateDrainTheDH130AisequippedwithprimaryandsecondarycondensatedrainlineconnectionsThedrainsmustbetrappedexternaltotheunitandconnectedpernationalandlocalplumbingcodestodrainlinesthatwillcarryawaythewatercollectedbythedehumidifierTopreventwaterbeingremovedfromthetrapswhentheairconditioningunitisrunningthetrapdimensionsmustbeequivalenttothedimensionofthetrapontheassociatedairconditioningsystemTheprimaryandsecondarydrainlinesmustbeattachedtothetrapoutletsandpitchedawayfromtheunitaminimumof18perfoottoassureproperwaterremovalItisrecommendedadrainpanbeplacedundertheunitifinstalledabovealivingareaoraboveanareawherewaterleakagecouldcausedamageTheprimarycondensatedrainmustberoutedaccordingtonationalandlocalcodesThesecondarycondensatedrainlinemustdischargetoavisiblelocationtoalerttheenduserthataproblemexistswithdehumidifiersprimarydrainagesystemDuctingTheunitisfurnishedwithtwobeaded8roundcollarsforductconnectionstotheinletandtheoutletofthedehumidifierThesearelocatedinsidetheunitandmustbeattachedtotheunitbytheinstallerusingscrewsandgasketsorcaulkingCenterthecollarsovertheinletandoutletopeningsinthecabinetInsulatedflexibleductsincompliancewithUnderwritersLaboratorysULStandardforFactoryMadeDuctMaterialsVL78andinstalledpertheductmanufacturersrecommendationshouldbeusedtoconnectthedehumidifiertotheheatingorairconditioningsystemTheinstallationandconnectionsmustbeincompliancewithnationalandlocalcodesandbecompletelytightandleakfreeDuctsshouldbeasshortaspossiblenottoexceed100ftequivalentlengthandsupportedincompliancewiththeductmanufacturersrecommendationCAUTIONAllductconnectionsmustbesealedAnyairleakageintheductworkwilladverselyaffecttheoperationofthedehumidifierandmayleadtounsatisfactoryperformance4
Page 5
DampersOptionaldampersmaybeinstalledintheoutletductinletductorinanoutsideairductThesedampersmustbeafullflowmotorizedtypeDonotuseanytypeofpressureoperateddamperasunacceptablepressuredropwillaffectunitoperationAlldampersmustbeinstalledincompliancewiththedampermanufacturersrecommendationsandbeinsulatedandsealedperthesectiononductingaboveElectricalInstallationmustbeperformedbyaqualifiedservicetechnicianandmustcomplywithallnationalandlocalcodesRemovepowertothedevicebeforeinstallingorservicingtheequipmentTheelectricalsupplyrequirementsarelistedontheunitnameplateandintheSpecificationTableonpage3UseaseparatefusedbranchelectricalcircuitcontainingaproperlysizedfuseorcircuitbreakerRunthiscircuitdirectlyfromthemaincircuitboxtoanelectricaldisconnectwhichmustbereadilyaccessibleandlocatedwithinsightofthedehumidifierConnectthedisconnecttotheelectricalconnectionsinsidethedehumidifierutilizingtheholesizedfor12conduitprovidedontheenteringairendoftheunitInstallationoftheelectricalsupplylinemustbeinaccordancewiththeNationalElectricCodeANSINFPANo70latesteditionorCanadianElectricalCodePartlCSAStandardC221andlocalbuildingelectriccodesusingcopperconductorsonlyDANGERTurnoffelectricalpoweratthefuseorservicepanelbeforemakinganyelectricalconnectionsThegroundconnectionmustbecompletedbeforemakinglinevoltageconnectionsFaiiuretodosocanresultinelectricalshockseverepersonalinjuryordeathThedehumidifiermustbeinstalledsothattheelectricalcomponentsareprotectedfromwaterfromanysourceWARNINGLhotandNneutralpolaritymustbeobservedwhenmakingtheelectricalconnectiontotheunitOptionalRemoteDehumidistatThedehumidifierissuppliedwithitsownselfcontaineddehumidistatwhichincludesanairsamplingsequenceTheunitmayalsobecontrolledbyaremotedehumidistatlocatedinaconditionedspaceDonotlocatetheremotedehumidistatintheductworkItisrecommendedthattheremotedehumidistatbelocatedinanareaclosetotheheatingorairconditioningsystemthermostatoutofdraftsawayfromheatsourcesandoutofdirectsunlightItshouldbelocatedapproximatelyfivefeetabovethefloorinanareawithgoodaircirculationatanaveragetemperatureandrelativehumidityRemovethejumperonterminals51and52andconnecttheremotedehumidistatasshownontheunitconnectiondiagramDANGERThecabinetmustbepermanentlygroundedConnectthegroundwiretothegroundterminalprovidedintheunitFailuretogroundthecabinetcanresultinfireelectricalshockpersonalinjuryordeathInstallationOptionsThedehumidifiermaybeinstalledsothatthedehumidifierandthecentralheatingorairconditioningsystemfansoperateseparatelyofeachotherIndependentOperationormaybeconnectedrequiringthedehumidifierandthecentralheatingorairconditioningsystemfansoperateatthesametimeDependentOperationIndependentOperationDuctConnectionsInthisarrangementthedehumidifierisconnectedacrossorinparallelwiththeheatingorairconditioningsystemThedischargeofthedehumidifierisconnectedtothedischargeoftheheatingorairconditioningsystemTheinletconnectionofthedehumidifierisconnectedtotheinletductoftheheatingorairconditioningsystemWhenthedehumidifierisconnectedforindependentoperationtheheatingorairconditioningsystemfanandthedehumidifierfanwillnotoperateatthesametime5
Page 6
ISupplAiIigoAiondilningSyITpRerrnAViewlIIMidIIOpMnINColperDehumidifierConnectedtheHeatingorAirConditioningSystemPipedParalleltoSystemCelinllFloorJootppI0OptKINCPamlRelurnAiDehumidifierSuspendedfromCeilingHeatingorAirConditioningSystemBlowerandDehumidifierDONOTOperateattheSameTimeControlsConnectionThedehumidifiercontrolsmustinterfacewiththeheatingorairconditioningsystemThisinterfaceisrequiredtodothefollowingTurnoffthedehumidifieriftheheatingorairconditioningsystemisinthecoolingorheatingmodeTurnofftheheatingorairconditioningsystemfanduringdehumidifieroperationiftheFANswitchonroomthermostathasbeenplacedintheONpositionforcontinuousoperationFivewiresrunfromtheheatingorairconditioningsystemtothedehumidifierToaccomplishthisindependentoperationinterfaceseetheUnitConnectionDiagramandthefollowingConnecttheCWandYterminalsonthedehumidifiertothecorrespondingterminalsontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheCWorYterminalsontheheatingorairconditioningsystemDisconnecttheexistingthermostatwirefromtheGterminalontheheatingorairconditioningsystemUsingawirenutsplicethiswiretoanewwireandthenconnecttotheG1terminalonthedehumidifierConnecttheG2terminalonthedehumidifiertotheGterminalontheheatingorairconditioningsystemAllcontrolswiringincludingconnectiontoaremotedehumidistatmustbe1822gaugeandmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhrougha78diameterholelocatedontheairentryendofthedehumidifieradjacenttotheunitmounteddehumidistatNoteThisisseparatefromthepowerentryUnitConnectionDiagramIndependentOperationDEHUMIDIFIERSYSTEMDAMPERiOPTIONAL24VAC40VAMINTRANSFORMER11UNITCONNECTIONDIAGRAMINDEPENDENTOPEMTlONDEHUMIDIFIEROHoNCTHERMOSTATYWAIRHANDlERfFURNACEyWAllMOUNTODEHUMIOISTiTDOPTIONALGywC010CGwcPUCS2REMOVEJUMPERON152WHENOPTIONALDEHUMJDISTATISUSED516
Page 7
DamperConnectionIfanoptionaldampersisusedinthedischargereturnductthismaybecontrolledbythedehumidifierSeeUnitConnectionDiagramIndependentOperationaboveforconnectiondetailsWhenconnectedasshownintheabovediagramthedehumidifierprovidesonlytheswitchinginterfaceforthedampersPowerforthesedevicesmustbeprovidedwithaseparatetransformernotprovidednotfromthetransformerlocatedinthedehumidifierThedampercontrolwiringmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhroughthecontrolwireentrylocatedontheairEntryendoftheunitNoteThisisseparatefromthepowerentryDependentOperationDuctConnectionsInthisarrangementthedehumidifierisconnectedeitherupstreamordownstreamoftheheatingorairconditioningsystemBoththedischargeandthereturnofthedehumidifierareconnectedtothesamesideofthesystemWhenthedehumidifierisconnectedfordependentoperationtheheatingorairconditioningsystemfanandthedehumidifierfanmustoperateatthesametimeDehumidifierConnectedforDependentOperationwithHeatingorAirConditioningSystemPipedReturnReturnDischargeAirHeatingorAirConditioningSystemTopViewReturnAirl8axDehumidifierInstalledonFloorHeatingorAirConditioningSystemBlowerandDehumidifierMUSTOperateattheSameTimeControlsConnectionThedehumidifiercontrolsmustinterfacewiththemainheatingorairconditioningsystemThisinterfaceisrequiredtoensurethattheheatingorairconditioningsystemfanisonwhenthedehumidifierisoperatingTwowiresrunfromtheheatingorairconditioningsystemtothedehumidifierToaccomplishthisdependentoperationusetheinterfaceUnitConnectionDiagramDependentOperationbelowandthefollowingConnecttheDterminalsonthedehumidifiertotheRterminalontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheheatingorairconditioningsystemConnecttheDHterminalonthedehumidifiertotheGterminalontheheatingorairconditioningsystemDonotdisconnectanyoftheexistingwiresfromtheheatingorairconditioningsystemAllcontrolswiringincludingconnectiontoaremotedehumidistatmustbe1822gaugeandmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhrougha78diameterholelocatedontheairentryendoftheunitadjacenttotheunitmounteddehumidistatNoteThisisseparatefromthepowerentryDamperConnectionAlthoughnotnecessaryifanoptionaldampersisutilizedinthedischargelreturnductthismaybecontrolledbythedehumidifierSeetheUnitConnectionDiagramDependentOperationbelowforconnectiondetailsWhenconnectedasshownintheUnitConnectionDiagramthedehumidifierprovidestheswitchinginterfaceforthedampersaswellasthelinevoltagepowertothetransformernotincludedPowerforthedampersisprovidedbythedehumidifierThedampercontrolwiringmustmeetnationalandlocalelectricalcodesEntryintothedehumidifieristhroughthecontrolwireentrylocatedontheairentryendoftheunitNoteThisisseparatefromthepowerentry7
Page 8
UnitConnectionDiagramDependentOperationUNITCONNECTIONDIAGRAMDEPENDANTOPERATIONT86DEHUMIDIFiERN3DEHUMIDIFIERSYSTEMDAMPEROPTIONALAleTHIIDHERMOSTATNCEMENTJIyywWCCcGGG1RRG24S124VACTRANSFORMERTB1040VAMINDEHUMIDIFIERBYOTHERSWALLMOUNTEDOEHUMID1STATOPTIONALREMOVEJUMPERON182WHENOPTIONALOEHUMIDISTATISUSEDInitialSetUpTurnpowertothedehumidifieronAdjustthesetpointknobtoapproximately60relativehumidityForwallcontrolsadjusttheunitmountedcontroltoitsminimumrelativehumidityRHsettingandsetthewallmounteddehumidistattoadesiredlevelItisrecommendedthatitfirstbesettoapproximately60RHandthenadjustednosoonerthan24hourslatertoahigherorlowersetpointasdesiredItisrecommendedthatalladjustmentsbemadeinnomorethan3incrementsatnolessthan24hourintervalsDependingupontheconditionsthedehumidifiermayoperateforextendedperiodsespeciallywhenfirststartedorafterhavingbeenoffMaintenanceFilterThedehumidifierisequippedwithapermanentnylonmeshairfilterThisfilteriswashableandshouldbecleanedregularlyItisrecommendedtocleanthehumidifierfilteratthesametimetheheatingorairconditionerfilterisreplacedIfthefilterhasbecomeexcessivelydirtywhencleanedatthisintervalitmaybenecessarytoadjustthecleaningscheduletomorefrequentcleaningExcessdirtonthefilterwillreduceoveralleffectivenessofthedehumidifierDrainThedraintraporoutletshouldbecheckedandcleanedannuallyFlushitwithwatertoensurethedrainisclear8
Page 9
EcC1taoC1c2IIIIi1lllJ0I11i1IILIIIiIIijI1e1rJqiLlidzNIIlH09lddnsdJMOdIIL@DciLdcrqI110uco1Bo08E20togg15kqSlMl51sIIiltJ1il@I14jilISIIYQjmjHVI8II1jerlIrc111liijiiiIIJIIIIII1I1ifEicg9rHljJtiJ1filWI01VSImj11iilrjlYjIIIiiuHt4VCFrrlTuJIIJIfJ1IIImilIIMI5lTrnrIIJcLIlr5WmujTJ0lrnTruIIiFA1IiLtMrij0iQBo111111IillIII1iIIidIiiiithaQ11it0ii8jiiI1iIiliseJ1U11l1iiilsvulinIIll1zQIolII1SaI1oJl1I12iIRR181eiltzv11u00Q1IjCljiIj1111111rIIIIrlifdeltilIIIlI
Page 10
Page 11
Page 12
WarrantyFullOneYearPartsWarrantyAllpartsofthedehumidifierarewarrantedtobefreefromdefectsforoneyearfromthedateofpurchasebytheoriginalconsumerwheninstalledpertheinstallationinstructionsandinaccordancewithalllocalstateandnationalcodesfornormalresidentialuselimitedFiveYearCompressorOnlyWarrantyInadditiontothefulloneyearpartswarrantydescribedabovewewillexchangethecompressorduringthesecondyearthroughfifthyearfromtheoriginaldateofpurchaseprovidingthecompressorisdefectiveinmaterialorworkmanshipTransportationhandlingandlaborcoststodiagnoserepairorreplacesuchdefectivepartsarenotcoveredbythislimitedpartswarrantyandaretheownersresponsibilityReadyaccesstotheunitforserviceistheresponsibilityoftheownerNOTElntheeventofanyrequiredpartsreplacementwithintheperiodofthiswarrantyreplacementpartsshallbefurnishedandwillbewarrantedonlyfortheperiodremainingontheoriginalwarrantyExceptionsThewarrantydoesnotcovernormalmaintenancelaborchargestransportationchargesforreplacementpartsreplacementofrefrigerantorfiltersanyotherservicecallorrepairsOtherthanforresidentialuseiftheunitisputintocommercialbusinessrentalorotheruseorapplicationwemakenowarrantiesexpressorimpliedWewillnotbeliablefordamagesordelayscausedbyeventsbeyondourcontrolincludingaccidentalterationabusewargovernmentrestrictionsstrikesfirefloodorotheractsofGodDurationofWarrantyThewarrantybeginsonthedateofpurchasebytheoriginalconsumerTheconsumermustprovideareceiptedbillofsaleasproofofwarrantyperiodWithoutthisproofthewarrantybeginsondateofshipmentfromthefactory1TherearenootherexpressorimpliedwarrantiesoranywarrantyofmerchantabilityWedonotwarrantthattheunitissuitableforanyparticularpurposeorcanbeusedinbuildingsorroomsofanyparticularsizeorconditionexceptasspecificallyprovidedinthisdocumentTherearenootherwarrantiesexpressorimpliedwhichextendbeyondthedescriptioninthisdocument2AllwarrantiesimpliedbylawarelimitedindurationtotheoneyearpartsorfiveyearcompressortermsofthewarrantyYourexclusiveremedyislimitedtothereplacementofdefectivepartsandcompressorWewillnotbeliableforanydamagescausedbyanydefectinthisunitSomestatesdonotallowlimitationonhowlonganimpliedwarrantylastsordonotallowtheexclusionorlimitationofincidentalorconsequentialdamagessotheabovelimitationorexclusionsmaynotapplytoyou3NowarrantiesaremadeforunitssoldoutsidethecontinentalUnitedStatesandCanadaYourdistributororfinalsellermayprovideawarrantyonunitssoldoutsidetheseareasHowtoObtainWarrantyServiceorPartsIfyouhaveawarrantyclaimnotifyyourinstallerpromptlyIfwithinareasonabletimeaftercontactingyourinstallersatisfactoryservicehasnotbeenreceivedcontactCustomerService250WestLaurelStreetColtonCalifornia92324UsAEncloseareportofinspectionbyyourinstallerorservicepersonIncludethemodelnumberserialnumberanddateofpurchaseOwnerresponsibilitiesaresetforthintheinstructionmanualReaditcarefullyrAIRSPONGE250WestLaurelStreetColtonCalifornia92324UsAwwwewfccomTelephone9098250993IIJIUIIIIIIISubjecttoChangewithoutNoticeMarch2007
Loading...