Thank you for purchasing General Tools & Instruments’ SAM800HI or
SAM800IND Digital Pocket Heat Index Monitor. Please read this user’s
manual carefully and thoroughly before using the instrument.
Both models measure ambient temperature and relative humidity (RH)
and calculate the Dew Point and the Heat Index based on those values.
Dew Point can be considered an air saturation temperature associated
with RH. The higher the RH, the closer the Dew Point is to the ambient
temperature. Heat Index is an attempt to quantify how hot a combination
of temperature and RH “feels”.
The only differences between the SAM800HI (Sports model) and the
SAM800IND (Industrial model) are the color of the housing (red vs. black)
and the packaging (illustrated box vs. white box).
The front-panel
of readings to show on the two-line LCD. The options are:
• Heat Index + ambient temperature
• RH + ambient temperature
MODE, MIN/MAX
and
HOLD
buttons let you choose a pair
2
• Dew Point + ambient temperature
• Minimum, maximum and held readings of any of the three pairs
KEY FEATURES
• Adjustable Heat Index
• Min/Max memory + data hold
• 2-line x 4-digit LCD
• °F/°C switch
• 20-minute Auto Power Off function (can be disabled)
• Pocket clip on back
• 1 year limited warranty
DANGER
setpoint
WHAT’S IN THE CASE
The SAM800HI and SAM800IND each come in a box along with a
“CR2032” button battery and this user’s manual.
PRODUCT OVERVIEW
Figure 1 shows all of the controls, indicators and physical features of the
SAM800HI/SAM800IND. Figure 2 shows all possible indications on the
LCD. Familiarize yourself with the positions and functions of all controls,
indicators and physical features before moving on to the Setup
Instructions and Operating Instructions.
ABCDEF
JIH
Fig. 1. The controls, indicators and physical features of the
SAM800HI/SAM800IND
A. Ambient temperature and relative humidity (RH) sensors
B. 2-line x 4-digit LCD
C.
ON/OFF
D.
HOLD
button
button. “Freezes” both readouts.
G
3
E.
MIN/MAX
parameters in selected display mode.
F. Pocket clip (on back)
G. Battery compartment (on back)
RESET
H.
MODE
I.
ambient temperature; 2) RH + ambient temperature; or 3) Dew Point +
ambient temperature.
UNIT
J.
Fig. 2. All possible display indications
1. Primary readout
DANGER
2.
beeper sounds) when
calculated Heat Index value
exceeds setpoint.
HEAT IDX
3.
that primary readout is
showing a Heat Index or
Dew Point temperature.
4.
MAX
showing maximum or minimum values.
5. Secondary readout
6.
°C
7.
RH
8.
Hold
readings.
button. Displays lowest, and then highest values of both
button. Clears Min/Max memory.
button. Selects one of three display options: 1) Heat Index +
button. Selects Fahrenheit or Celsius temperature unit.
alert. Flashes (and
and DP. Indicate
1
2
3
{
{
{
4
and
MIN
. Indicate that primary and secondary readouts are
and °F. Indicate selected temperature unit.
and %. Indicate that primary readout is showing a %RH value.
. Indicates that both readouts are showing held (“frozen”)
5
8
7
{
6
SETUP INSTRUCTIONS
INSTALL BATTERY
1) Use a coin to open the battery compartment on the back on the unit.
2) Place the included “CR2032” button battery in the battery well with the
printed side up. Using a fingertip, push the battery down until it is fully
seated.
3) Replace the battery compartment cover and secure it.
4
RESET HEAT INDEX DANGER SETPOINT (OPTIONAL)
The SAM800HI/SAM800IND monitor is factory-set to sound a visual and
audible alarm when the Heat Index exceeds 82°F. To change this
setpoint:
1) With the unit powered off, press and hold the
least 3 seconds. Doing so will cause the display to show the following
terms, all flashing:
2) Press the
the
press and hold either button to make large changes quickly.
3) When the primary display shows the new Heat Index
that you want, press the
will sound to confirm that the setting was saved. The unit will then
power on in the last selected display mode.
UNIT
MODE
button to increase the setpoint by the same amount. You can
82.0, °F
button to decrease the setpoint by 0.1°F per press, or
and
HEAT IDX
HOLD
button to save the setting. The beeper
ON/OFF
.
button for at
DANGER
setpoint
OPERATING INSTRUCTIONS
REAL-TIME DISPLAY MODES
To monitor ambient temperature, RH, Heat Index and/or Dew Point in
real time
unit will power on in the last selected display mode.
To change display modes
is always shown on the secondary (lower) readout. Pressing the
button cycles the value shown on the primary (upper) display from Heat
Index (
To hold (“freeze”) any pair of readings
button.
press the
To change the temperature unit
press the
DISPLAYING MIN/MAX READINGS
The SAM800HI/SAM800IND monitor can display the lowest and highest
ambient, Dew Point and Heat Index temperatures and/or RH values
recorded during a measuring session. A measuring session begins when
the unit is powered on and ends when the unit is powered off. However,
the Min/Max memory can be reset at any time.
, begin by pressing the
HEAT IDX
Hold
) to
RH%
will appear on the top line of the LCD.
HOLD
button again. The
UNIT
button.
ON/OFF
, press the
to Dew Point (DP), and then back to Heat Index.
Hold
to or from °F (the factory default) or °C,
button to power on the unit. The
MODE
button. Ambient temperature
on both displays, press the
To release the hold
indication will disappear.
MODE
HOLD
,
5
To display the lowest (minimum) values
the selected mode, press the
MIN/MAX
of the two parameters shown in
button once. The Min values will
appear in their assigned positions, with temperature on the lower readout
MIN
and RH, Dew Point or Heat Index on the upper readout.
will appear
on the bottom line of the LCD to indicate that the readouts are showing
minimum values.
To display the highest (maximum) values
in the selected mode, press the
MIN/MAX
of the two parameters shown
button a second time. Like Min
values, the Max values will appear in their assigned positions on the
MAX
primary and secondary readouts.
will appear on the bottom line of
the LCD to indicate that the readouts are showing maximum values.
To exit Min/Max mode
hold the
MIN/MAX
To clear the Min/Max memory
and resume showing real-time values, press and
button a third time.
, press the
RESET
button. The instrument
will confirm the erasure by briefly showing all LCD indications at the
same time, followed by a single beep.
DISABLING AUTO POWER OFF
To conserve battery charge, the SAM800HI/SAM800IND monitor
automatically powers off after any 20-minute period of front-panel
inactivity.
To disable this Auto Power Off function
power it back on in the following special way: Press and hold the
button before pressing the
ON/OFF
lower-case “n” to appear on the LCD. Two seconds later, the
, power the unit off and then
HOLD
button. Doing so will cause a large,
n
will
disappear and the instrument will power on normally—but with the APO
function disabled. There is no display indication of APO status (whether
the function is enabled or disabled).
SPECIFICATIONS
• Temperature Measurement Range: 32° to 122°F (0° to 50°C)
• Temperature Measurement Accuracy: ±1.8°F (±1°C)
• Relative Humidity Measurement Range: 0 to 100%
• RH Measurement Accuracy: ±3% of reading from 10 to 90%RH; ±4% of
reading elsewhere
• Dew Point Measurement Range/Accuracy: 32° to 140°F (0° to 60°C)/ ±3%
• Heat Index Range/Accuracy: 70° to 115°F (21° to 45°C)/ ±3%
• Auto Power Off Trigger: 20 minutes of front-panel inactivity
• Battery Life: 100 hours (average)
• Dimensions: 6.7 x 1.85 x 0.5 in. (168 x 47 x 15mm)
• Power Source: 1 “CR2032” battery (included)
OPERATING & MAINTENANCE TIPS
When all display indications flash at once, it’s time to replace the
“CR2032” battery that powers the thermometer (although measurements
will remain valid for several hours after the icon first appears). To replace
the battery, follow the instructions on p. 4.
After subjecting the SAM800HI/SAM800IND to a large change in ambient
temperature, wait at least 30 minutes before making measurements to
guarantee the accuracy of readings.
Remove the battery when storing the unit or when you do not expect to
use it for an extended period of time (months rather than weeks).
Do not disassemble the unit or immerse it in water. Doing so voids the
1-year limited warranty.
WARRANTY INFORMATION
General Tools & Instruments’ (General’s) SAM800HI or SAM800IND Digital
Pocket Heat Index Monitor is warranted to the original purchaser to be
free from defects in material and workmanship for a period of one year.
Subject to certain restrictions, General will repair or replace this
instrument if, after examination, the company determines it to be
defective in material or workmanship. The warranty period begins on the
date of purchase. You are encouraged to register your product online.
General will extend your warranty an additional 60 days if you register at
www.generaltools.com/ProductRegistry.
This warranty does not apply to damages that General determines to be
from an attempted repair by nonauthorized personnel or misuse,
alterations, normal wear and tear, or accidental damage. The defective
unit must be returned to General Tools & Instruments or to a Generalauthorized service center, freight prepaid and insured.
7
Acceptance of the exclusive repair and replacement remedies described
herein is a condition of the contract for purchase of this product. In no
event shall General be liable for any incidental, special, consequential or
punitive damages, or for any cost, attorneys’ fees, expenses, or losses
alleged to be a consequence of damage due to failure of, or defect in any
product including, but not limited to, any claims for loss of profits.
Register now at www.generaltools.com/ProductRegistry to receive a
60-day extension to your warranty.
RETURN FOR REPAIR POLICY
Every effort has been made to provide you with a reliable product of
superior quality. However, in the event your instrument requires repair,
please contact our Customer Service to obtain an RGA (Return Goods
Authorization) number before forwarding the unit via prepaid freight to
the attention of our Service Center at this address:
Remember to include a copy of your proof of purchase, your return
address, and your phone number and/or e-mail address.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
NOTICE - WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS.