PNG2000A
USER’S MANUAL
Natural
Gas Detector
PNG2000A-Manual-FINAL-121807 12/18/07 3:36 PM Pag
• High Sensitivity
• Low Power Consumption
• Microprocessor controlled
• Auto zero calibration
• Reliable performance
• Simple operation
• Audible and visual alarm
AN ACCURATE GAS SENSOR WITH LOW POWER
CONSUMPTION AND HIGH SENSITIVITY.
This unit is applicable anywhere combustible gasses are used. Once
the level of combustible gas reaches the preset alarm level, an alarm
will sound and the user will see an LED indication. The detector has
visual and audible indications for fault, low battery and alarm.
2. FEATURES:
Auto zero calibration
Fast response and resume
Easy to operate
A variety of sounds for different status
Large range of operating temperature
3. SPECIFICATIONS:
Gas detected: natural gas (methane), LPG (propane, butane) etc.
and other combustible gases.
Range: 0~100%LEL
Sampling: Natural diffusion
Operating temperature: -4° to 131ºF (-20° to 55ºC)
Operating humidity: < 95%RH
PNG2000A-Manual-FINAL-121807 12/18/07 3:36 PM Pag
Operating voltage: DC3V (two “AA” batteries)
Operating current: < 150mA
Low alarm: (20±5) %LEL
High alarm: (50±10) %LEL
Response time: <5s
Alarm method: Visual and audible alarm
Sound: 肁65dB
4. CONFIGURATION
1. Sensor
2. High alarm LED
3. Low alarm/fault LED
4. Power LED
5. Power switch
6. Wrist strap
7. Battery cover
5. OPERATING INSTRUCTION:
1. Open the battery cover and insert two “AA”
batteries into the unit. Observe polarity.
2. SWITCH ON; the detector will start its 15
second warm up. The three LEDs will light
in turn. After a tweet, the red and yellow LED will be off. The
warm up will be finished.
The detector is ready to detect gas.
3. Visual and audible indication instruction:
The green power LED will flash consistently during operation.
There will be a sound alarm every 7 seconds during the non
alarm status.
1.
2.
3.
4.
5.
6.
7.
PNG2000A-Manual-FINAL-121807 12/18/07 3:36 PM Pag
LOW ALARM: when the gas concentration is between the low
alarm and high alarm point, the detector will give a sound alarm
every 0.5 second and the yellow LED will light.
HIGH ALARM: when the gas concentration is above the high
alarm point, the detector will give a sound alarm every
0.5 second, the red LED and the yellow LED will light.
LOW VOLTAGE: when the battery power is lower than 2.7V, the
detector will give a sound alarm every 30 seconds.
SENSOR FAULT: when the sensor faults, the detector will give a
sound alarm every 1.5 seconds and the yellow LED will light.
6. NOTICES:
• The alarm may be activated if there is smoke, alcohol, perfume or
other volatile items in the vacinity.
• Please activate the product in clean air. If the detector is
activated in a gas concentration above 30%LEL, the detector may
indicate sensor fault. Then you need to reactivate the detector in
clean air.
• Avoid excess shock. Do not place any pressure on the tip.
• Low voltage may affect the sensitivity. Please replace the
batteries as soon as possible when the power is low.
• Don’t store the detector in the environment with caustic gas.
• Please operate according to the operation manual.
DECLARATION:
Specifications and Features are subject to change without notice.
PNG2000A-Manual-FINAL-121807 12/18/07 3:36 PM Pag