General AUHA12LN, AUHA12LALN, AOHA12LACL, AUHA14LN, AUHA14LALN, AOHA14LACL Technical Manual
R410A
INDOOR UNIT
1. CASSETTE
AU A12LALN
AU A14LALN
TYPE :
D2D_AU027E/02
2007.09.13
1. FEATURE
MODEL :
CASSETTE TYPE
AU A12LALN
AU A12-14L
CASSETTE TYPE
AU A12-14L
AU A14LALN
FEATURES
ENERGY SAVING
• ALL DC DESIGN
• Heat exchange efficiency increased and larger air flow by adoption of new type turbo fan
ADVANCEMENT IN COMFORT
• Quiet operation was realized by adoption of new type turbo fan
• Improvement of air stream
IMPROVEMENT IN AIRFLOW RANGE (14 TYPE)
Wind velocity at maximum point of airflow range is 0.5m/s
Conventional type
New type
2.5 m
3.7 m
EXPANSION OF AIR OUTLET ADJUSTMENT RANGE (14 TYPE)
Auto airflow direction and auto swing
Expanded air outlet range provides more comfortable space
• The number of air outlet can be selected.
4-way direction3-way direction
• High ceiling mode
Air reaches sufficiently up to 3.5m height, even it is compact cassette type.
High ceiling
3.5m
- (01 - 01) -
CASSETTE TYPE
AU A12-14L
IMPROVEMENT OF INSTALLATION & MAINTENANCE
CASSETTE TYPE
AU A12-14L
• COMPACT DESIGN
Fits the European size ceiling.
590
570
590
570
18kg18kg
• EASY MAINTENANCE
Maintenance of fan motor and fan
Maintenance of fan motor and fan can be done
easily after taking off the panel,
since bell-mouth can be removed easily
A : Fan motor
B : 2 stage turbo fan
C : Bell-mouth
D : Panel
Long life filter
Standard equipment
A
B
C
D
Adaptation of transparent drainage parts
Easy check of operation of drain-up kit
When you install
EASY INSTALLATION
Easy setting by wireless or wired remote controller.
OTHER FUNCTIONS
• Setting the filter sign
The indoor unit has sign to inform the user that it is time to clean the filter
• Setting the cooler room temperature correction
• Setting the heater room temperature correction
• Auto restart
Grille cover
- (01 - 02) -
2. COMBINATION
2-1. OUTDOOR UNIT
CASSETTE TYPE
AU A12-14L
MODEL :
AO A12LACL
AO A14LACL
2-2. REMOTE CONTROLLER
2-2-1. WIRED REMOTE CONTROLLER
MODEL : UTB- UD
CASSETTE TYPE
AU A12-14L
2-2-2. WIRELESS REMOTE CONTROLLER
MODEL : UTB- NA
2-3. DECORATION PANEL
MODEL : UTG-UF A-W
CAUTION
Remote controller and decoration panel are not supplied with the indoor unit.
Separate purchase is necessary.
- (01 - 03) -
3. SPECIFICATIONS
AU A12LALNAU A14LALN
210 × 1310 × 13.3
210 × 1250 × 13.3
210 × 1310 × 13.3
210 × 1250 × 13.3
Pipe type
Panel
Panel
Panel
Panel
9.52( 3/8 in.)12.70( 1/2 in.)
30 or less
6.35 ( 1/4 in.)
Flare
18 to 32
80 or less
Copper tube
Aluminium
INVERTER HEATPUMP
CASSETTE MODEL
230V 50Hz
198-264V 50Hz
42
4.5 (10.0)
Type
Model name
mm
Rated
Min.-Max.
Rated
Min.-Max.
Rated
*Max.
Power source
Available voltage range
Capacity
Cooling
Heating
Input power
Cooling
kW
Heating
Rated
*Max.
Current
Cooling
A
Heating
Rated
*Max.
Rated
*Max.
kW/kW
Moisture removal
Cooling
Heating
Remote controller type
Drain pipe
Material
Size
Operation range
Cooling
kg(lb.)
Gross
Size
mm
Weight
Net
Connection pipe
Type × Q'ty
Cooling
Enclosure
Dimensions
( H × W × D )
Net
mm
Gross
Heat exchanger type
2.6 (5.7)
Turbo × 1
Sound pressure level
Cooling
dB(A)
Heating
Fan
Heating
Airflow
rate
m3/h
European energy label
ABS
Outer diameter : 25.4 / Inner diameter : 19.4
WIRED or WIRELESS
PS
WHITE
245 × 570 × 570
49 x 700 x 700
265 x 730 x 625
120 x 765 x 755
CASSETTE TYPE
AU A12-14L
EER3.333.21
COP3.693.71
CoolingAA
HeatingAA
kW3.54.3
BTU/h1195014650
kW0.9 - 4.40.9 - 5.4
BTU/h3100 - 150003100 - 18400
kW4.15.0
BTU/h1400017050
kW0.9 - 5.70.9 - 6.5
BTU/h3100 - 194003100 - 22100
1.051.33
1.732.07
1.111.34
2.302.88
4.65.8
7.59.0
4.95.9
10.012.5
l/h (pints/h)1.2 ( 2.1 )1.5 ( 2.6 )
High600680
Med530580
Low470490
Quiet410410
High600800
Med530680
Low470580
Quiet410450
CASSETTE TYPE
AU A12-14L
Motor outputW
High3738
Med3434
Low3030
Quiet2727
High3743
Med3438
Low3134
Quiet2930
Dimensions (H × W × D)
Fin pitch1.201.20
Rows x Stages2 x 102 x 10
Fin type
Material
Colour
Unit
Unit
Unit15 (33)15 (33)
Unit18 (40)18 (40)
Liquid
Gas
Method
°C
%RH
Heating°C
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Ceiling mode : Standard
*The maximum current and the maximum input value are the maximum values when operated within the operation (temperature) range.
To set “3-way directions”, the air outlet shutter plate (UTR-YDZA) sold separately
must be installed and “outlet-direction” switched to “3-way” by remote controller.