General AUH30L, AUH30LUAS, AOH30LMAWL, AUH36L, AUH36LUAS, AOH36LMBWL Technical Manual
R410A
4 . CASSETTE TYPE :
AU 30LUAS, AU 36LUAS
D2D_AU003E/02
2006.01.10
4-1. FEATURE
MODELS :
AU 30LUAS / AO 30LMAWL
AU 36LUAS / AO 36LMAWL
FEATURES
Easy maintenance
The control box is easily accessible for maintenance work
Wide opening for easy access.
Detachable,washable filter and intake grille.
Wide opening and long-life filter.
Long-life filter
High efficiency, long-life filter extends the cleaning cycle.
CASSETTE TYPE
AU30-AU36
Long-life filter
CASSETTE TYPE
AU30-AU36
Slim intake grille
Slim type intake grille can fit the ceiling after installation.
20
(unit: mm)
Group controller
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same settings.
Connectable quantity : Maximum 16 indoor units for 1 remote controller.
- (04 - 01) -
Duct connection hole opening
Fresh air can be introduced through this opening.
Distribution
duct
Fresh air
Distribution
duct
CASSETTE TYPE
CASSETTE TYPE
AU30-AU36
AU30-AU36
Conditioned air can be distributed by means of a distribution duct.
Two-way
One-way
- (04 - 02) -
4-2. REMOTE CONTROLLER
4-2-1. WIRED REMOTE CONTROLLER
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible.
SUMOTUWETH FR SA
7
3126 9
15 18 21
High performance and compact size
Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
When setting up a timer, operation mode and a temperature
setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16)
Error indication.(A maximum of 16 error histories are memorizable.)
Up to 16 indoor units can be simultaneously controlled.
Anti freeze and energy saving operation are possible.
Easy installation with a slim shape with no boldge in the back.
The room temperature can be controlled by being detected the temperature
accurately with built-in thermo sensor.
CASSETTE TYPE
Three functions are combined in
AU30-AU36
one unit.
Wired
remote
controller
Weekly
timer
Setback
timer
CASSETTE TYPE
AU30-AU36
Built-in timers
Setback timerWeekly timer
Possible to set ON/OFF time to operate twice each day
of the week.
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example
(Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
Easy-to-understand time bar display
24°C
SUMOTUWETH FR SA
7
3126 9
15 18 21
Screen
after setup
At "Weekly timer" + "Set back timer" setup
24°C 28°C 24°C
0 3 6 9 12 15 18 21 Time
Possible to set temperature for two time spans and
for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
24°C
28°C
Easy-to-understand operationSimple installation
Components are compatible with standard
switch boxes. Flat back construction allows
equipment to be installed wherever it is
needed.
Timer
area
[
Variable timer control
]
The operation/display sections are zoned according to time and operation, enabling variable programming to match application.
Operation
area
European
switch box
- (04 - 03) -
JIS box
FUNCTIONS
1
START/STOP button
Pressed to start and stop operation.
2
Display
SUMOTUWETH FR
SA
369
11
12
10
12 15 18 21
2
7
8
9
CLOCK ADJUST
SET BACK
DELETESET
DAY
DAY OFF
ENERGY
SAVE
THERMO
SENSOR
14
1
3
4
5
6
13
Display panel
CASSETTE TYPE
AU30-AU36
15
16
1718 19
Set Temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
5
Thermo sensor button
6
Energy save button
Turns the energy efficient mode on and off.
7
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER,
WEEKLY TIMER) Set the current time.
8
Day (DAY OFF) button
Temporarily cancels of one day timer.
9
Set back button
pressed select the set back timer.
CASSETTE TYPE
AU30-AU36
SUMOTUWETH FR
369
DIMENSION
120
SUMOTUWETH FR
CLOCK ADJUST
SET BACK
DELETESET
SA
369
12 15 18 21
DAY
DAY OFF
Front View
12 15 18 21
ENERGY
SAVE
SA
THERMO
SENSOR
202122
[ Unit : mm ]
120
10
Set time button
Pessed to select the set back timer.
11
Delete button
The schedule of a weekly timer is deleted.
12
Set button
Sets the date, hour, minute and on-off time.
13
Vertical air flow direction and swing button
Push for two seconds to change the swing mode
14
17
Operation lamp
Lights during operation and when the timer is on.
15
Timer and clock display
16
Operation mode display
17
Fan speed display
18
Central control display
19
Temperature display
20
Stand by display
Indicates during the oil recovery and defrosting operation.
21
Vertical swing display
22
Energy save display
SPECIFICATION
SIZE (H x W x D mm)120 x 120 x 17
WEIGHT( g )160
CABLE LENGTH( m )
POWER( V )
10
12
- (04 - 04) -
4-3. SPECIFICATIONS
AU 30LUASAU 36LUAS
AO 30LMAWLAO 36LMAWL
230V 50Hz230V 50Hz
Fin Pitch
Fin Pitch
600/600
490/490
420/420
-/-
CASSETTE MODELS
INVERTER HEAT PUMP TYPE
INVERTER
Turbo × 1
Propeller × 1
100
103
DC TWIN ROTARY(INVERTER)
1300
850/900
Copper tube
Aluminium
2 × 12
252 × 970 × 26.6
1.30
Copper tube
Aluminium
798 × 900 × 36.38
2 × 38
1.30
White(5Y9/0.5NN)
Beige(10YR7.5/1.0NN)
296 × 830 × 830
830 × 900 × 330
455 × 1060 × 1025
970 × 1050 × 445
37/52(82/115)
FLARE
9.52(3/8 inc.)
15.88(5/8 inc.)
64/70(141/154)
50(chargeless:15)
WIRED
ABS
30
R410A
2200
POE
Outer diameter 37.0 / Inner diameter 32.0
1550/1550
1300/1300
1100/1100
3600/3800
48.0/48.0
44.0/44.0
41.0/41.0
-10 to 43
-10 to 24
FAN MOTOR OUTPUT
W
OUTDOOR
NOISE LEVEL
(SOUND
PRESSURE)
COOL/HEAT
Fin
Coil
INDOOR
HEAT
EXCHANGER
TYPE
OUTDOOR
TYPE
HEATING
CAPACITY
RATED/MAX
TYPE
MODEL NAME
OUTDOOR
POWER SOURCE
INDOOR
FAN TYPE x Q'ty
A
FAN SPEED
COOL/HEAT
INDOOR
MOISTURE REMOVAL
STARTING CURRENT
INDOOR
EER
COP
r.p.m
REMOTE CONTROLLER
DRAIN PIPE
MATERIAL
REFRIGERANT
SIZE
TYPE
OPERATION(OUTDOOR)
°C
TYPE
INDOOR
MAX LENGTH
Rows × Stages
mm
Rows × Stages
mm
OUTPUT
NET
CASING COLOR
STARTING METHOD
COMPRESSOR
REFRIGERANT OIL
mm
kg(lbs)
DIMENSIONS
H × W × D
WEIGHT
NET /
GROSS
PIPE
MAX HEIGHT
mm
CONNECTION METHOD
SIZE
AVAILABLE VOLTAGE RANGE
GROSS
Coil
dB(A)
INDOOR
OUTDOOR
Fin
198-264V 50Hz
EUROPEAN ENERGY LABEL
m3/h
kW
AIR
CIRCULATION
COOL/HEAT
CURRENT
kW/kW
RATED/MAX
INPUT POWER
COOLING
COOLINGRATED/MAX2.86/3.464.01/4.08
HEATINGRATED/MAX2.84/3.373.49/4.15
COOLINGRATED/MAX12.5/15.217.6/17.9
HEATINGRATED/MAX12.4/14.815.2/18.2
COOLING2.972.49
HEATING3.523.21
High
Med
Low
OUTDOORHigh
High
Med
CASSETTE TYPE
AU30-AU36
OUTDOORHigh
Low
Quiet
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
C E
kW8.50/10.0010.00/11.20
BTU/h29000/3410034100/38200
kW10.00/11.2011.20/12.77
BTU/h34100/3820038200/43600
A1515
l/h (pints/h)3.0(6.3)4.0(8.4)
53.0/55.054.0/55.0
CASSETTE TYPE
AU30-AU36
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
W
Coil Dimensions
Coil Dimensions
LIQUID
GAS
m
m
CHARGEg
COOLING
HEATING
Note:Specifications are based on the following conditions.
Cooling:Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB.
Heating:Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
- (04 - 05) -
4-4. DIMENSIONS
4-4-1. OUTDOOR UNIT
MODELS : AO 30L, AO 36L
(Unit : mm)
Top view
900
830
CASSETTE TYPE
AU30-AU36
21
9
Front view
77
31330
400
12
CASSETTE TYPE
AU30-AU36
Side view
650
Air flow
370
MOUNTING POSITION
When there are obstacles at the
back or front sides.
100 mm
or more
600 mm
or more
100 mm
or more
603
Bottom view
When there are obstacles at the
back, side(s), and top.
600 mm or more
300 mm
or more
(
250
S
er
mm or
v
i
c
e s
pac
more
e)
196
99
147
170
When there are obstacles at the
back, side with the installation of
more than one unit.
250 mm
or more
250 mm
or more
300 mm
or more
- (04 - 06) -
4-4-2. INDOOR UNIT
MODELS : AU 30L, AU 36L
30
(Unit : mm)
296
Side view
940
CASSETTE TYPE
CASSETTE TYPE
AU30-AU36
750
830
AU30-AU36
940
Bottom view (Panel)
Drain InsideDia. 32
Dia. 37Outside
Side view (Standard setting)
750
830
Bottom view
298.5
305.5
285
60
(Drain pipe)
248.5
120
(Small pipe)
(Large pipe)
150
250
Side view (Slender setting)
- (04 - 07) -
MOUNTING POSITION
Floor
Strong and durable ceiling
2,300 mm
or more
1,200 mm
or more
1,000 mm
or more
Obstruction
CASSETTE TYPE
CASSETTE TYPE
AU30-AU36
You can select 2-way setting
(A) Standard setting(B) Slender setting
265 mm
300 mm
or more
100 or more100 or more
or more
100 or more
AU30-AU36
(4 directions)(3 directions)
Piping position
(2 directions)(2 directions)
100 or more
- (04 - 08) -
4-5. REFRIGERANT CIRCUIT
MODELS : AU 30L / AO 30L, AU 36L / AO 36L
CASSETTE TYPE
CASSETTE TYPE
AU30-AU36
AU30-AU36
- (04 - 09) -
4-6. WIRING DIAGRAMS
4-6-1. OUTDOOR UNIT
MODELS : AO 30L, AO 36L
CASSETTE TYPE
CASSETTE TYPE
AU30-AU36
AU30-AU36
- (04 - 10) -
TO POWER SUPPLY
TO INDOOR UNIT
Loading...
+ 23 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.