OPERATING MANUAL
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
AIR CONDITIONER
CASSETTE TYPE
SUMOTUWETH FR
AM
PM
369
12 15 18 21
KULLANMA K‹TABI
SA
English
Deutsch
Français
Español
Italiano
KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК
BU KILAVUZU, DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN
P/N9372132050
EλληvIkά
Português
Русский
Türkçe
CONTENTS
SAFETY PRECAUTIONS................................................ 1
NAME OF PARTS ........................................................... 2
PREPARATORY OPERATION......................................... 3
OPERATION ................................................................... 3
TIMER FUNCTIONS ....................................................... 5
ON/OFF TIMER............................................................... 5
WEEKLY TIMER ............................................................. 6
TEMPERATURE SET BACK TIMER ............................... 8
OPERATING TIPS........................................................... 9
ADJUSTING THE DIRECTION OF AIR CIRCULATION ....
SWING OPERATION.................................................... 11
CARE AND MAINTENANCE........................................ 12
SELF-DIAGNOSIS ........................................................ 13
TROUBLESHOOTING .................................................. 14
SAFETY PRECAUTIONS
● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the unit.
● Do not become over-exposed to cold air by staying in the direct path of the air flow of the air conditioner
for extended periods of time.
● Do not insert fingers or objects into the outlet port or intake grilles.
● Do not start and stop air conditioner operation by turning off the electrical breaker and so on.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker,
and consult authorized service personnel.
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
DANGER!
11
CAUTION!
● Provide occasional ventilation during use.
● Do not direct air flow at fireplaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not hang objects from the indoor unit.
● Do not set flower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Turn off power source when not using the unit for extended periods.
● Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter.
● Connection valves become hot during Heating; handle with care.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the air flow.
● When restarting after a long period of disuse in the winter, turn the power switch on at least 12 hours
before starting the unit.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art
works.
● Do not apply any heavy pressure to radiator fins.
● Operate only with air filters installed.
● Do not block or cover the intake grille and outlet port.
● Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units.
● Avoid installing the air conditioner near a fireplace or other heating apparatus.
● When installing the indoor and outdoor units, take precautions to prevent access by infants.
● Do not use inflammable gases near the air conditioner.
En-1
NAME OF PARTS
Remote controller
E
2
7
8
9
0
A
B
SUMOTUWETH FR
369
12 15 18 21
CLOCK ADJUST
SET BACK
DELETE SET
DAY
DAY OFF
H
G
F
SA
I
J
D
1
3
ENERGY
SAVE
THERMO
SENSOR
4
5
6
C
1 Start/Stop Button
2 Set Temperature Button
3 Master Control Button
4 Fan Control Button
5 THERMO SENSOR Button
6 ENERGY SAVE Button
7 Timer Mode (CLOCK ADJUST)
Button
8 DAY (DAY OFF) Button
9 SET BACK Button
0 Set Time Button
A DELETE Button
B SET Button
C Vertical Airflow Direction and
Swing Button
D Operation Lamp
E Timer and Clock Display
F Operation Mode Display
G Fan Speed Display
H Operation Lock Display
I Temperature Display
J Function Display
Defrost Display
Thermo Sensor Display
Energy Save Display
Vertical Swing Display
En-2
PREPARATORY OPERATION
Set the current day and time
1
CLOCK ADJUST
Press the timer mode (CLOCK
ADJUST) button for 2 seconds
or more. The time display on
the remote controller will flash.
3
DAY
2
Press the set time buttons to set the current time.
Press repeatedly to adjust the current time in 1minute increments. Press and hold to adjust the
current time in 10-minute increments.
SUMOTUWETH FR
ex. Monday 10:00
DAY OFF
SU MO TU WE TH FR SA
SA
Press the DAY button and select the current day.
appears around the selected day.
A
4
Press again to end.
OPERATION
Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
To start/stop operation
Press the start/stop button.
CLOCK ADJUST
To set the operation mode
● Operation mode setting
● Room temperature setting
Lower Raise
● Fan speed setting
Operation lamp
Air conditioner ON: Lit brightly
Air conditioner OFF: Not lit
Press the master control button to set the operation mode.
If DRY is selected, the fan speed will be set to AUTO.
AUTO COOL DRY HEATFAN
Press the set temperature buttons to set the room temperature.
Temperature setting range
AUTO ............................................... 18 to 30 °C
COOL/DRY ....................................... 18 to 30 °C
HEAT ................................................ 16 to 30 °C
Press the fan control button to set the fan speed.
En-3
AUTO HIGH MED LOW
Energy save
ENERGY
SAVE
Room temperature sensor selection
THERMO
SENSOR
Press the THERMO SENSOR button to select whether the
room temperature is detected at the indoor unit (remote
sensor) or the remote controller.
Press the ENERGY SAVE button to start or stop the energy-saving air conditioner operation.
For details on the function, refer to page 9.
Indoor unit
When the
temperature is detected at the remote controller.
thermo sensor display appears, the room
NOTES
• This function is locked at the factory. In order to detect the room temperature correctly, consult authorized service
personnel when using this function.
• If this function is locked, the location where the room temperature is detected cannot be changed and the
mark flashes when the THERMO SENSOR button is pushed.
Child lock function
DAY
Press the DAY (DAY OFF) button and SET button simulta-
CLOCK ADJUST
SET BACK
DELETE SET
DAY OFF
neously for 2 seconds or more to activate the child lock
function and lock all buttons on the remote controller.
Press the buttons again for 2 seconds or more to deactivate the child lock function.
When the child lock function is activated, the
appears. If any button is pressed during the child lock,
the
CL
display flashes.
mark
En-4
TIMER FUNCTIONS
OFF timer (See page 5.)
Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops
after the set time has passed. The timer can be set up to 24 hours in advance.
ON timer (See page 5.)
Use this timer function to start air conditioner operation. The timer operates and air condition operation starts
after the set time has passed. The timer can be set up to 24 hours in advance.
WEEKLY timer (See page 6.)
Use this timer function to set operating times for each day of the week.
Use the DAY OFF setting to switch off timed operation for a selected day in the coming week.
Because all days can be set together, the weekly timer can be used to repeat the timer settings for all of the days.
Temperature SET BACK timer (See page 8.)
Use this timer function to change the set temperature in the operation times set for each day of the week.
This can be used together with other timer settings.
ON/OFF TIMER
To set the ON/OFF timer
1
● To cancel
CLOCK ADJUST
No display
NON
STOP
DELETE
SUMOTUWETH FR
Press the timer mode button to select the ON timer or OFF timer.
OFF
TIMER
• Press the DELETE button to cancel the timer mode.
• The timer mode can also be canceled by changing the timer mode using the timer mode button.
ON
TIMER
WEEKLY
TIMER
2
From 1 to 24 hours
Press the set time buttons to set the time.
After the time is set, the timer will start automatically.
The amount of time until the OFF timer operates that is displayed on the timer display decreases as time passes.
ex. OFF timer set for 6 hours
SA
En-5