General ARG25R, ARG25RLC, AOG25RNBL, ARG30R, ARG30RLC Technical Manual

...
DUCT SPLIT TYPE AIR CONDITIONER
TECHNICAL MANUAL
CONTENTS
FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Duct Split Type Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
EXTERNAL VIEW OF PRODUCT. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SAMPLE INSTALLATION / INSTALLATION STYLES. . . . . . . . . . . 4
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ARG45A/45R/36A/36R
Performance Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Additional Refrigerant Charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ARG25A/25R
Performance Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Additional Refrigerant Charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FAN PERFORMANCE AND AIR FLOW . . . . . . . . . . . . . . . . . . . . . 9
ARG45A/45R/36A/36R
External Static Pressure (at 415V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cooling/Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Outlet Air Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
ARG30A/30R
External Static Pressure (at 240V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cooling/Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Outlet Air Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ARG25A/25R
External Static Pressure (at 240V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cooling/Heating Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Outlet Air Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ARG45A/36A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
ARG45R/36R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ARG30A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
ARG30R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
ARG25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
ARG25R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ARG45/36/30/25 INDOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ARG45/36 OUTDOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
ARG30/25 OUTDOOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PRODUCT LINEUP
50Hz Models
INDOOR UNIT OUTDOOR UNIT
ARG45A AOG45AC ARG45R AOG45RC ARG36A AOG36AC ARG36R AOG36RC ARG30A AOG30AB ARG30R AOG30RB ARG25A AOG25AZ ARG25R AOG25RZ
– 1 –
FEATURES
COUPLING PIPE ASS’Y
CONTROL BOX
DRAIN PORT
AUX PIPE ASS’Y
DUCT SPLIT TYPE FEATURES
• Installed behind the ceiling (or with a double ceiling for existing rooms) this design offers space savings and low noise.
• One external unit is capable of conditioning the air of multiple rooms.
• With a beautiful finish, the outlet grille does not stick out into the room.
PRODUCT FEATURES
• Ultra thin models for very low ceilings
27 cm
• Piping can be laid in almost any directions
25,000/30,000/36,000/45,000BTU/h Types
25,000/30,000/36,000/45,000BTU/h Types
– 2 –
Highly functional LCD wired remote
TIMER MODE
CLOCK ADJUST
FAN
CONTROL
MASTER
CONTROL
SET
TIMER
SET
TEMP
ENERGY
SAVE
ZONE
CONTROL
START
STOP
controller
• Two remote controls for operation in different rooms.
• Auto restart function in case of power outage.
• Repeat timer can turn the unit on/off every day at the same time .
• FUNCTIONS
(1)Twin Remote (2)Zone Control (3)Auto Restart (4)PROGRAM Timer /
REPEAT Timer
(5)Simultaneous 16 Air
Conditioners Control
(6)Energy Save Operation
Zone control
Capable of simultaneously controlling only desinated air conditioners to stop .
Control several units with just one remote controller
One remote controller can control up to 16 air conditioners. All the air conditioners can be oper­ated with the same setting.
Energy save operation
The energy conservation mode (ENERGY SAVE) raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode, using a computer program to economically control the operation of the unit. If you press the ENERGY SAVE button while the air conditioner is on, it will change to the conservation mode. If you press the ENERGY SAVE button while the unit is in the timer mode (ON timer, PROGRAM timer, or REPEAT timer), the unit will go into the conservation mode when the unit starts with the timer.
Easy maintenance
• Easy maintenance with ability to replace all electrical components from the panel.
• Safe design incorporating an anti-drop construction in all main components.
Cooling operation possible at outdoor temperatures ranging from 0 to 52°C.
(For all models)
Heating operation possible at low outdoor temperatures as low as -5°C.
(For AOG30R/36R/45R Types)
Capable of fresh air intake
• Can intake fresh air with the installation of flexible ducts.
High static pressure type (ARG45/36 Type)
• High static Pressure type capable of withstanding a standard external static pressure of 98Pa.
Pipe length up to 50m with height differential of up to 30m (ARG45/36 T ype)
Equipped with automatic heat expansion valve (ARG45/36 Heat Pump Models)
• Capable of constantly operating at optimum conditions ev en giv en load fluctuations .
– 3 –
EXTERNAL VIEW OF PRODUCT
Remote controller
Outdoor unit (For ARG25 type)
Outdoor unit (For ARG30 type)
Outdoor unit (For ARG45/36 type)
SAMPLE INSTALLATION/INSTALLATION STYLES
SAMPLE INSTALLATION
INSTALLATION STYLES
• Embedded in Ceiling
• Embedded in Ceiling
• Hanging from Ceiling
• Hanging from Ceiling
– 4 –
SPECIFICATIONS
Model
Power Source
Capacity BTU/h
Total Input
Total Ampacity
E.E.R.
Starting Current A
Indoor Unit High
Outdoor Unit
Refrigerant Charge kg Pipe Size mm Connection Method Pipe Length/Height m
Operation Temperature Remote Controller (Cable Length)
Static Pressure Pa Rated Condition(JIS B8616- )
Cooling
Heating Cooling
Heating Cooling Heating Cooling Heating
Fan Speed Med r.p.m.
Air Circulation
Noise (SPL) Med dB
Fan Type x Q'ty Fan Motor Output W Dimensions mm Weights Net/Gross kg Fan Speed r.p.m. Air Circulation m3/h Noise(SPL) dB Fan Type x Q'ty Fan Motor Output W Compressor Type Motor Output kW Protection Dimensions mm Weights Net/Gross kg
Indoor Unit
Outdoor Unit
kW/kW
High
Low High Med m3/h
Low
Low
Cooling Heating
Cooling In/Out Heating In/Out
- Hz V
kW
kW
BTU/h
kW
A
°C
ARG45ALB3 ARG45RLB3 ARG36ALB3 ARG36RLB3 ARG30ALA ARG30RLA ARG25ALA ARG25RLA
AOG45ACA3L AOG45RCD3L AOG36ACA3L AOG36RCD3L AOG30ABJL AOG30RBJL AOG25AZAL AOG25RZAL
3 - 50 3 - 50 3 - 50 3 - 50 1 - 50 1 - 50 1 - 50 1 - 50
380 - 415 380 - 415 380 - 415 380 - 415 220 - 240 220 - 240 220 - 240 220 - 240
12.4 - 12.7 12.4 - 12.7 10.3 - 10.5 10.3 - 10.5 8.6 - 8.8 8.6 - 8.8 7.00 - 7.10 6.95 - 7.05
42,400 - 43,400 42,400 - 43,400 35,200 - 35,800 35,200 - 35,800 29,400 - 30,000 29,400 - 30,000 23,900 - 24,200 23,700 - 24,100
––––– 13.4 - 13.7 ––––– 10.5 - 10.7 ––––– 8.8 - 9.1 ––––– 7.60 -7.85 ––––– 45,800 - 46,800 ––––– 35,800 - 36,500 ––––– 30,000 - 31,100 ––––– 25,900 - 26,800
4.45 - 4.57 4.45 - 4.57 3.73 - 3.45 3.88 - 3.95 3.30 - 3.40 3.35 - 3.45 2.64 - 2.77 2.70 - 2.80 ––––– 4.23 - 4.35 ––––– 3.18 - 3.25 ––––– 2.90 - 3.00 ––––– 2.50 - 2.60
7.5 - 7.5 7.5 - 7.5 6.4 - 6.4 6.6 - 6.6 15.8 - 16.3 16.0 - 16.5 12.8 - 13.2 12.7 - 13.0 ––––– 7.4 - 7.4 ––––– 6.1 - 5.8 ––––– 14.1 - 14.6 ––––– 12.0 - 12.3
2.79 - 2.78 2.79 - 2.78 2.76 - 2.76 2.65 - 2.66 2.61 - 2.59 2.57 - 2.55 2.65 - 2.56 2.57 - 2.52 ––––– 3.17 - 3.15 ––––– 3.30 - 3.29 ––––– 3.03 - 3.03 ––––– 3.04 - 3.02
55 55 42 42 80 80 61 61 1,340 1,340 1,250 1,250 1,240 1,240 890 890 1,270 1,270 1,150 1,150 1,140 1,140 820 820 1,170 1,170 1,050 1,050 1,040 1,040 745 745 2,200 2,200 2,000 2,000 1,650 1,650 1,100 1,100 2,000 2,000 1,800 1,800 1,550 1,550 1,000 1,000 1,800 1,800 1,600 1,600 1,350 1,350 900 900
49.0 49.0 47.0 47.0 47.0 47.0 44.0 44.0
47.0 47.0 45.0 45.0 45.0 45.0 42.0 42.0
45.0 45.0 43.0 43.0 43.0 43.0 40.0 40.0
Sirocco x 2 Sirocco x 2 Sirocco x 2 Sirocco x 2 Sirocco x 2 Sirocco x 2 Sirocco x 2 Sirocco x 2
275 x 1 275 x 1 275 x 1 275 x 1 275 x 1 275 x 1 70 x 1 70 x 1
270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700 270 x 1,210 x 700
45/60 45/60 45/60 45/60 43/58 43/58 43/58 43/58
790 790 790 790 760 760 735 735
5,500 5,500 5,900 5,900 3,450 3,450 2,590 2,590
59.0 59.0 57.5 59.0 55.0 55.0 56.0 56.0
Propeller x 2 Propeller x 2 Propeller x 2 Propeller x 2 Propeller x 1 Propeller x 1 Propeller x 1 Propeller x 1
63 x 2 63 x 2 63 x 2 63 x 2 63 x 1 63 x 1 60 x 1 60 x 1
Recipro Recipro Recipro Recipro Recipro Recipro Recipro Recipro
3.7 3.7 3.0 3.0 2.85 2.85 1.875 1.875
Internal Overload Relay Internal Overload Relay Internal Overload Relay Internal Overload Relay Internal Overload Relay Internal Overload Relay Internal Overload Relay Internal Overload Relay
1,152 x 940 x 370 1,152 x 940 x 370 1,152 x 940 x 370 1,152 x 940 x 370 900 x 900 x 350 900 x 900 x 350 643 x 840 x 336 643 x 840 x 336
102/116 108/122 94/108 96/110 85/97 85/97 67/75 68/76
3.40 3.15 2.80 2.15 2.85 2.15 2.07 2.65
9.53, 19.05 9.53, 19.05 9.53, 19.05 9.53, 19.05 9.53, 15.88 9.53, 15.88 9.53, 15.88 9.53, 15.88 Flare Flare Flare Flare Flare Flare Flare Flare
50/30 50/30 50/30 50/30 25/15 25/15 25/15 25/15
In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52 In 18-30, Out 0-52
––––– In 16-30, Out 5-21 ––––– In 16-30, Out 5-21 ––––– In 16-30, Out 5-21 ––––– In 16-30, Out 0-21
LCD(10m) LCD(10m) LCD(10m) LCD(10m) LCD(10m) LCD(10m) LCD(10m) LCD(10m)
98(Max.176) 98(Max.176) 98(Max.176) 98(Max.176) 118(Max.176) 118(Max.176) 98(Max.157) 98(Max.157)
27/19, 35/24 27/19, 35/24 27/19, 35/24 27/19, 35/24 27/19, 35/24 27/19, 35/24 27/19, 35/24 27/19, 35/24
––––– 20/15.5, 7/6 ––––– 20/15.5, 7/6 ––––– 20/15.5, 7/6 ––––– 20/15.5, 7/6
• Specifications and design are subject to change without notice for further improvement. Please check with your dealer.
• Cooling/heating capacities are based on the following conditions. Cooling Heating Indoor temp. : 27°C DB/19°C WB Indoor temp. : 20°C DB/15.5°C WB Outdoor temp. : 35°C DB/24°C WB Outdoor temp. : 7°C DB/6°C WB
– 5 –
PERFORMANCE DATA
PERFORMANCE RATE (ARG45A/45R/36A/36R/30A/30R)
Cooling Capacity (%)
OUTDOOR TEMP. (°C)
25 30 35 40 46 50
21 93 90 87 81 75 69 INDOOR 24 93 96 93 88 81 75 TEMP. (°C) 27 105 103 100%95 88 80
30 113 111 103 102 96 89
• Performance values are cited taking 10.5kW (35,800BTU/h) as 100% for the 36 Model, 12.5kW (43,300BTU/h) as 100% for the 45 Model, and 8.8kW (30,000BTU/h) as 100% for the 30 Model.
• Indoor temperature of 27/19°C and outdoor temperature of 35/24°C represent JIS-SL conditions for cooling.
ARG45A/45R ARG45R
15.2
14.0
12.7
11.4
Capacity(kW)Total input(kW)
10.2
8.9
4.6
4.1
3.7
Cooling Heating
Heating Capacity (%)
OUTDOOR TEMP. (°C)
-5 0 5 7 10 15 20
INDOOR TEMP. (°C)
• Performance values are cited taking 10.7kW (36,500BTU/h) as 100% for the 36 Model, 13.7kW (46,700BTU/h) as 100% for the 45 Model, and 9.1kW (30,000BTU/h) as 100% for the 30 Model.
• Indoor temperature of 20°C and outdoor temperature of 7/6° repre­sent JIS-SL conditions for heating.
Indoor DB/WB(˚C)
31/22.5
27/19.0
23/16.5 31/22.5 19/13
27/19.5
23/16.5
19/13
15 78 91 102 105 110 115 119 20 73 86 97 100%106 111 115 25 66 80 91 95 100 108 111
(at External Static Pressure 98 Pa)
Indoor
15
16.4
15.1
13.7
12.3
11.0
Capacity(kW)
9.6
4.4
3.9
Total input(kW)
3.5
DB(˚C) 20 25
25 20
15
0 5 10 15 20 25 30 35 40 45 50 52
ARG36A/36R ARG36R
12.6
11.6
10.5
9.5
Capacity(kW)Total input(kW)
8.4
7.4
4.0
3.6
3.2
0 5 10 15 20 25 30 35 40 45 50 52
Cooling Heating
Indoor
DB/WB(˚C)
31/22.5
27/19.0 23/16.5 31/22.5 19/13
27/19.0
23/16.5
19/13
-5 /
-6
12.8
11.8
10.7
9.6
8.6
Capacity(kW)
7.5
3.3
2.9
Total input(kW)