European energy ranking rank A achieved by all DCization and optimization of the refrigerant cycle.
Quiet operation
Air flow mode can be set in 4 steps and more detailed air flow setting is possible.
36 type: 32 dB / 45 type: 34 dB at operation in the Quiet mode.
Filter sign
Dirtying of filter is detected by air conditioner operating time and the user is informed.
FLOOR / CEILING TYPE AB A36-45L
Economy operation
Operation that suppresses maximum power consumption is performed.
Wired/wireless simultaneous use possible
Wired remote controller and wireless remote controller can be simultaneously used.
Installation
OPEN SPACECONCEALEDWALL MOUNTED
(for high-ceilinged room)
Double auto swing
Combination of up/down and right/left air direction swing allows three-dimensional air
direction control.
Since up/down air direction flaps operate automatically, according to the operating
mode of the unit, it is possible to set the air direction based on the operating mode.
VERTICALHORIZONTAL
SWING
SWING
- (01 - 01) -
Filter sign operating time (Standard/long/short/no display)
FLOOR / CEILING TYPE AB A36-45L
Filter sign display time interval and filter sign no display can be selected.
Ceiling height (standard/high ceiling)
Air conditioner operation capacity (air flow) switching is possible as response to height of installation ceiling.
Cooling room temperature correction (Standard/low control)
Air conditioner control temperature can be switched to a little low as response to installation conditions.
Heating room temperature correction (Standard/low/slightly high/high control)
Air conditioning control temperature can be slightly adjusted as response to installation conditions.
Auto restart (ON/OFF)
ON/OFF of the function which automatically resets operation to the operation state before the power interruption at power recovery when there was a power interruption during operation can be selected.
Room temperature sensing function (ON/OFF) only at wired remote controller connection
Sensor which controls the room temperature can be selected in two types: "Indoor sensor only" or
"Indoor sensor or wired remote controller sensor can be switched by remote controller operation".
Fresh-air intake
FLOOR / CEILING TYPE AB A36-45L
INDOOR
OUTDOOR
- (01 - 02) -
2. COMBINATION
2-1. OUTDOOR UNIT
FLOOR / CEILING TYPE AB A36-45L
MODEL :
AO A36LATL
AO A45LATL
2-2. REMOTE CONTROLLER
2-2-1. WIRED REMOTE CONTROLLER
MODEL : UTB- UD
2-2-2. WIRELESS REMOTE CONTROLLER
FLOOR / CEILING TYPE AB A36-45L
MODEL : UTB- NA
CAUTION
Remote controller is not supplied with the indoor unit.
Separate purchase is necessary.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
*The maximum current and the maximum input value are the maximum value when operated within the operation range(temperature)