General AOHA32JAT3 Technical Manual

R410A
D2D_MU014E/01
2007.06.12
1 . MULTI TYPE : 3ROOM TYPE ASHA09JACM
ASHA12JACM ASHA18JATM ASHA24JATM
- (01 - 01) -
3ROOM TYPE
3ROOM TYPE
1. FEATURE
1-1. MODEL
INDOOR UNIT
AOHA32JAT3
ASHA09JACM ASHA12JACM
ASHA18JATM ASHA24JATM
OUTDOOR UNIT
Wall Mounted Type (Compact) Wall Mounted Type
Indoor unit connection pattern
Connection Pattern
No.1 Indoor unit No.2 Indoor unit No.3 Indoor unit
1 9,000 9,000 9,000
2 9,000 9,000 12,000
3 9,000 9,000 18,000
4 9,000 12,000 12,000
5 9,000 12,000 18,000
6 12,000 12,000 12,000
When 3 indoor units are connected (Btu/h)
Connection Pattern
No.1 Indoor unit No.2 Indoor unit
1 9,000 9,000
2 9,000 12,000
3 9,000 18,000
4 9,000 24,000
5 12,000 12,000
6 12,000 24,000
7 12,000 18,000
8 18,000 18,000
When 2 indoor units are connected (Btu/h)
- (01 - 02) -
3ROOM TYPE
3ROOM TYPE
1-2. WALL MOUNTED TYPE
MODEL : ASHA09J, ASHA12J
FEATURES
Fine symmetry design
Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a center mounted configuration and a lambda type heat exchanger to provide plenty of power.
Realizing the low noise operation by optimizing the air channel structure.
Wired remote controller and simple remote controller can not be applied to the compact wall mounted type indoor unit.
H257 x W808 x D187 (mm)
Powerful Output in spite of Small Size
Auto swing louver
Washable open panel
Low noise level
Vertical and horizontal symmetrical design matched to the interior decor
Compact design
36
29
HIGH
ASHA09J
Unit:dB(A)
Swing
Step
The Auto Swing Louver function ensures that air direction corresponds to the mode selected.
Cooling : 3-step (1-3) Heating : 6-step (1-6)
Removable and washable panel totally purges mold and dust.
Since the panel is removed and easily washed, the panel is always clean and filter cleaning is also simple.
Since there are few bars, only a daily wipe cleans the panel.
QUIET
- (01 - 03) -
3ROOM TYPE
3ROOM TYPE
MODEL : ASHA18J, ASHA24J
FEATURES
Fine symmetry design
High efficiency fan construction 7mm Lambda type evaporator improves the airflow path
Low-noise
Powerful Output
Vertical and horizontal symmetrical design matched to the interior decor
Easy-to-read center display
Big wide flaps with a powerful image
43
32
HIGH
QUIET
ASHA18J
Unit:dB(A)
Large air diffuser
Double auto swing
2-way draining route
7 lambda type evaporator
Large air diffuser
Large independently driven power diffuser
Effective air flow within a room is achieved by the unique operation of the power diffuser. The angle of the flap can be adjusted in six steps to give draught-free air flow.
Pleasant multi-air flow
Other features include continuation of the functions of the existing wall mounted type.
Wide air flow realized by unique operation of the power diffuser
1
3
4
5
6
2
1
3
4
5
6
2
Cooling
Heating
Large independ­ently driven power diffuser
Horizontal concentration and other air direction control
Warm air reaches every corner of the room.
6-step
6-step
Step Swing
Others
Auto Restart
Double auto swing
2-way draining route
- (01 - 04) -
3ROOM TYPE
3ROOM TYPE
2. REMOTE CONTROLLER
2-1. WIRELESS REMOTE CONTROLLER
Built-in timers
Easy operation
FEATURES
Four kinds of timers. Easy operation.
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Easy to change transmission code (4 patterns) by button operation.
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling while sleeping.
Cooling operation/dry operation
60min.
1 °C
2 °C
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Timer setting
• Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.)
A B C D
A B
C
D
Mixed-up
After code change
•Wide and precise transmitting range.
A B C D
1. Press the MASTER CONTROL button for more than five seconds to start the code change.
3. Press the MASTER CONTROL button again to end the code change.
2. Press the (+) or (-) button to select the desired code.
- (01 - 05) -
3ROOM TYPE
3ROOM TYPE
Display panel
Display
64
1
8
7
9
3
2
5
12
13
10
14
15
16
17
20
19
18
21
1
START/STOP button
Pressed to start and stop operation
Time adjust button
Sets the current time.
2
3
4
Sleep timer button
Pressed to select sleep timer.
5
Signal transmitter
6
Timer button
Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET)
7
Fan control button
8
Battery compartment lid
9
Air flow direction set button
17
18
Clock display
21
Master control display
20
Set temperature display
Fan speed display
12
Timer set indicator
Temperature set indicator
19
Timer mode display
Set temp./Set time/ Set remote controller custom code buttons
Sets the indoor temp./ Sets the current time and on-off time. /Sets R.C. custom code.
Master control / Code change buttons
Selects the operating mode (AUTO, FAN, COOL, DRY). /Start / end R.C. custom code change. (Max 4 types)
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
10
11
14
ACL button
Air flow direction swing button
Used when replacing batteries or change the code.
15
16
Transmit indicator
TEST
RUN
11
13
Test run button
Used when testing the air conditioner after installation.
SPECIFICATION
SIZE (H x W x D mm) 158 x 56 x 20
WEIGHT ( g ) 70 (w/o batteries)
ACCESSORY Holder
QUIET
QUIET
FUNCTIONS (For ASHA09J, ASHA12J)
- (01 - 06) -
3ROOM TYPE
3ROOM TYPE
Display panel
SPECIFICATION
Display
64
1
8
7
10
9
12
11
3
2
5
15
13
14
TEST
RUN
16
17
18
19
22
21
20
23
SIZE (H x W x D mm) 158 x 56 x 20
WEIGHT ( g )
70 (w/o batteries)
ACCESSORY Holder
1
START/STOP button
Pressed to start and stop operation
Time adjust button
Sets the current time.
2
3
4
Sleep timer button
Pressed to select sleep timer.
5
Signal transmitter
6
Timer button
Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET)
7
Fan control button
8
Battery compartment lid
9
Air flow direction vertical set button
10
Air flow direction vertical swing button
11
Air flow direction horizontal swing button
12
Air flow direction horizontal set button
19
20
Clock display
23
Master control display
22
Set temperature display
Fan speed display
15
Timer set indicator
Temperature set indicator
21
Timer mode display
Set temp./Set time buttons/Set remote controller custom code buttons
Sets the indoor temp./Sets the current time and on-off time /Set R.C. custom code
Master control button/
Code change
Selects the operating mode (AUTO, FAN, COOL, DRY). Start/end R.C. custom code change. (Max. 4 types)
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
13
14
16
Test run button
Used when testing the air conditioner after installation.
ACL button
Used when replacing batteries or change the code.
17
18
Transmit indicator
QUIET
QUIET
FUNCTIONS (For ASHA18J, ASHA24J)
- (01 - 07) -
3ROOM TYPE
3ROOM TYPE
3. SPECIFICATIONS
3-1. OUTDOOR UNIT
INVERTER MULTI MODELS
COOLING TYPE
AOHA32JAT3
230V 50Hz
198-264V 50Hz
kW 7.50
BTU/h 25600
kW 8.65
BTU/h 29500
RATED 2.22
MAX. 2.70
RATED 9.7
MAX. 12.0
A 15.0
COOLING kW/kW 3.38
HIGH 3300
LOW
-
HIGH 780
LOW
-
Propeller × 1
W 103
HIGH 48
LOW
-
Scroll
W 1200
Inverter
Copper tube
Aluminium
2 × 32
Fin Pitch 1.45
Coil Dimensions 672 × 900 × 36.38
Beige (10YR7.5/1.0NN)
NET 700 × 900 × 330
GROSS 835 × 1050 × 445
NET 53 (117)
GROSS 61 (134)
Flare
LIQUID
6.35(1/4in.) × 3
GAS
9.52(3/8in.) × 2,
m 25
m 60 (chargeless:60)
R410A
CHARGE g 1800
PVE
Connect to connection valve by the adapter.
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB/19°CWB,and outdoor temperature of 35°CDB/24°CWB. Heating : Indoor temperature of 20°CDB/15°CWB,and outdoor temperature of 7°CDB/6°CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
TYPE AVAILABLE VOLTAGE RANGE
MODEL NAME
POWER SOURCE
A
COOLING
AIR CIRCULATION Coil
FAN TYPE x Q'ty
FAN MOTOR OUTPUT
COMPRESSOR
m3/h
STARTING METHOD
RATED
EER
CAPACITY
MAX.
COOLING
INPUT POWER
COOLING
CURRENT STARTING CURRENT
kW
REFRIGERANT OIL
CONNECTION METHOD
MAX. PIPE LENGTH (Each unit)
mm
TYPE
SIZE MAX. PIPE LENGTH (Total)
PIPE
mm
CASING COLOR
REFRIGERANT TYPE
WEIGHT
kg(lb.)
DIMENSIONS H × W × D
mm
Rows × Stages
FAN SPEED COOL
r.p.m
OUTPUT
NOISE LEVEL (SOUND PRESSURE)
dB(A)
Fin
HEAT EXCHANGER TYPE
TYPE
12.70(1/2in.)
- (01 - 08) -
3ROOM TYPE
3ROOM TYPE
3-2. INDOOR UNIT
ASHA09JACM ASHA12JACM ASHA18JATM ASHA24JATM
kW 2.70 3.50 5.20 6.80
BTU/h 9200 11900 17800 23200
kW 3.15 3.65 5.80 7.20
BTU/h 10700 12400 19800 24600
pints/h(l/h) 2.1(1.0) 3.2(1.5) 3.6(1.7) 5.3(2.5)
High 470 520 950 1020
Med 430 470 800 820
Low 380 420 670 600
Quiet 350 380 570 500
High 1200 1310 1160 1290
Med 1100 1260 1000 1100
Low 1000 1190 830 870
Quiet 940 1000 780 730
W
High 36 38 43 47
Med 34 37 39 41
Low 31 35 35 36
Quiet 29 33 32 32
Rows × Stages 2 × 16 2 × 16 + 1 × 4
Fin Pitch 1.3 1.3 + 1.4
Coil Dimensions
mm
336 × 855 × 26.6
84 × 855 × 13.3
336 × 855 × 26.6
NET
GROSS
NET
GROSS
LIQUID
9.52(3/8in.)
GAS
12.70(1/2in.) 15.88(5/8in.)
m
m
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27°CDB/19°CWB,and outdoor temperature of 35°CDB/24°CWB. Heating : Indoor temperature of 20°CDB/15°CWB,and outdoor temperature of 7°CDB/6°CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
15
270 × 850 × 310
320 × 1120 × 220
348 × 1240 × 427
22(48)
9.52(3/8in.)
6.35(1/4in.)
10(22)
25
257 × 808 × 187
WALLMOUNTED INVERTER MODELS
16(35)
8(18)
198-264V 50Hz
COOLING TYPE
230V 50Hz
38171.3
2 × 12
CONNECTION METHOD
MODEL NAME
POWER SOURCE
TYPE
MAX.
CAPACITY
COOLING
AVAILABLE VOLTAGE RANGE
RATED
m3/h
mm
mm
MAX. HEIGHT
PIPE
SIZE MAX. LENGTH
SIZE
DRAIN PIPE
REMOTE CONTROLLER
MATERIAL
Inner diameter 28.0
Soft PVC
WIRELESS
Outer diameter 14.0
Inner diameter 25.5
Outer diameter 16.0
WIRELESS
Copper tube
252 × 632 × 26.6
MOISTURE REMOVAL
FLARE
Fin
kg(lb.)
Aluminium
CASING COLOR
mm
White (5Y9/0.5NN)
WEIGHT Coil
DIMENSIONS H × W × D
AIR CIRCULATION COOL
NOISE LEVEL (SOUND PRESSURE)
COOL FAN MOTOR OUTPUT
dB(A)
HEAT EXCHANGER TYPE
Cross flow Fan × 1
FAN SPEED COOL
FAN TYPE × Q'ty
r.p.m
- (01 - 09) -
3ROOM TYPE
3ROOM TYPE
When there are obstacles at the back or front sides.
When there are obstacles at the back, side(s), and top.
When there are obstacles at the back, side with the installation of more than one unit.
600 mm or more
250 mm or more
250 mm or more
300 mm or more
600 mm or more
100 mm or more
300 mm or more
AIR
AIR
100 mm or more
250 mm or more
(Service space)
MOUNTING POSITION
(Unit : mm)
4-1. OUTDOOR UNIT
4. DIMENSIONS
MODEL : AOHA32J3
Top view
Front view
Bottom view
Side view
If the space is larger that is stated, the condition will be the same as that are no obstacles.
- (01 - 10) -
3ROOM TYPE
3ROOM TYPE
(Unit : mm)
(Unit : mm)
MODEL : ASHA09J, ASHA12J
MODEL : ASHA18J, ASHA24J
257
808
Front view Side view
Front view
Side view
187
MOUNTING POSITION
1500 mm or over
2300 mm or over
Right side 50 mm or over
Left side 50 mm or over
60 mm or over
1,120
626
711
320
220
4-2. INDOOR UNIT
- (01 - 11) -
3ROOM TYPE
3ROOM TYPE
5. REFRIGERANT CIRCUIT
MODEL : AOHA32J3
EVAPOLATOREVAPOLATOREVAPOLATOR
REFRIGERANT PIPE 3/8" (9.52mm)
CHARGING VALVE
CHARGING VALVE
CHARGING VALVE
REFRIGERANT PIPE 3/8" (9.52mm)
REFRIGERANT PIPE 1/4" (6.35mm)
REFRIGERANT PIPE 1/2" (12.70mm)
REFRIGERANT PIPE 1/4" (6.35mm)
REFRIGERANT PIPE 1/4" (6.35mm)
Indoor unit A
OUTDOOR UNIT
Indoor unit B Indoor unit C
EXPANSION VALVE
EXPANSION VALVE
HEAT EXCHANGER
HEAT EXCHANGER
PRESSURE SW1
EXPANSION VALVE
STRAINER
DISTRIBUTOR
COMPRESSOR
STRAINER
ACCUMULATOR
TH
D
TH
C
Loading...