INVERTER MULTI
AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASH18LMA-W
ASH12LMACW
AOH24LMAM2
ASH9LMACW
ASH7LMACW
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . . . . .
ERROR CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . .
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . .
INDOOR PRINTED CIRCUIT BOARD
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . . . . . 11
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
STANDARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . 21
1
2
4
5
6
8
SPECIFICATIONS
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
ELECTRICAL DATA
POWER SOURCE
FREQUENCY
RUNNING CURRENT
INPUT WATTS
E.E.R.
MOISTURE REMOVAL
AIR CIRCULATION-Hi
(kW / kW)
COMPRESSOR
TYPE
DISCRIMINATION
REFRIGERANT
(A)
(kW)
R410A
COOL & HEAT
ASH18LMA-W
(kW)
(kW)
(V) 230 - 240
(Hz) 50
COOLING
HEATING
COOLING
HEATING
COOLING
HEATING
( /hr) 1.0
(m3/hr)
(g) 1,900
2.2
950
ASH12LMACW ASH9LMACW ASH7LMACW
AOH24LMAM2
5.8
6.4
7.6 - 7.3
7.2 - 6.9
1.73 - 1.73
1.64 - 1.64
3.35 - 3.35
3.90 - 3.90
1.6
520
Hermetic type, Inverter, 4 poles,
Three phase, DC motor, Rotary
TNB 220 FPCM
1.2
460 380
FAN MOTOR
POWER SOURCE
INDOOR UNIT
OUTDOOR UNIT
DIMENSIONS
INDOOR UNIT
OUTDOOR UNIT
WEIGHT
INDOOR UNIT
OUTDOOR UNIT
(V) 230 - 240
DISCRIMINATION
HI
MED (r.p.m.)
LO (r.p.m.)
QUIET (r.p.m.)
H x W x D (mm)
H x W x D (mm)
GROSS / NET (kg)
GROSS / NET (kg)
(r.p.m.)
(r.p.m.) 780 - 790
MFA-30HTT
1,160 - 1,180
1,000 - 1,020
850 - 870
800 - 820
320 x 1,120 x 220 257 x 808 x 187
22 / 16 10 / 8
MFA-40GR
1,310 - 1,310
1,260 - 1,260
1,190 - 1,190
1,100 - 1,100
650 x 830 x 320
MFA-40GR
1,200 - 1,200
1,100 - 1,100
1,000 - 1,000
940 - 940
62 / 56
MFA-40GR
1,000 - 1,000
900 - 900
850 - 850
800 - 800
2004.06.22
1
ERROR CONTENTS
ASH18LMA-W
ASH12LMACW
ASH9LMACW
ASH7LMACW
2004.06.22
4
REFRIGERANT SYSTEM DIAGRAM
Indoor
2004.06.21
5
CAUTION (AOH24LMAM2)
There is a mistake printed in "LABEL WIRING", which is on the back of
Top Plate in outdoor unit.
When you reconnect this model you should do as the correct "CIRCUIT DIAGRAM" shows,
which is in this service manual.
See the next page. It's the correct "CIRCUIT DIAGRAM".
It's better to take away incorrect "LABEL WIRING" from outdoor unit,
and put correct "CIRCUIT DIAGRAM" on it.
NOTE
Incorrect "LABEL WIRING" is on the serial No.T000001 to T001020 of AOH24LMAM2.
If you reconnect as it shows, two indoor units go like below.
When you turn on indoor unit A and turn off B,
indoor unit A blows, but it doesn't make you cool or warm.
indoor unit B makes itself cool or warm, but it doesn't blow.
When you turn off indoor unit A and turn on B,
indoor unit A makes itself cool or warm, but it doesn't blow.
indoor unit B blows , but it doesn't make you cool or warm.
2004.06.22
6
Models : ASH7LMACW
ASH9LMACW
ASH12LMACW
CIRCUIT DIAGRAM
OUTDOOR UNITINDOOR UNIT
Model : AOH24LMAM2
Model : ASH18LMA-W
2004.04.20
UNIT AUNIT B
7