General ABHA18LA, ABHA18LAT, AOHA18LACL, ABHA24LA, ABHA24LAT Technical Manual

...
R410A
INDOOR UNIT
1. FLOOR / CEILING TYPE
AB A18LAT AB F18LAT AB A24LAT AB F24LAT
:
D2D_AB021E/04
2008.04.08
3. SPECIFICATIONS
AB A18-24L
FLOOR / CEILING TYPE
Type
Model name
Power source
Available voltage range
European energy label
Rated
Cooling
Min. - Max.
Capacity
Rated
Heating
Min. - Max.
Cooling
Input power
Heating
Cooling
Current
Heating
EER 3.21 3.21
COP 3.61 3.61
Moisture removal
Airflow
Fan
Sound pressure level
Heat exchanger type
Enclosure
Dimentions ( H× W ×D )
Weight
Connection pipe
Operation range
Remote controller type
Drain pipe
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB. Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
The maximum current and the maximum input value are the maximum value when operated within the operation range(temperature).
rate
Type × Q'ty
Motor output W 80 80
Net
Gross
Net 27 ( 60 ) 27 ( 60 )
Gross 36 ( 79 ) 36 ( 79 )
Size mm
Method Flare Flare
Material
Size
Rated
*Max.
Rated
*Max.
Rated
*Max.
Rated
*Max.
Cooling
Heating
Cooling
Heating
Cooling
Heating
Dimensions (H × W × D) 252 × 800 × 39.9 252 × 800 × 53.2
Fin pitch 1.30 1.45
Rows x Stages 3 × 12 4 × 12
Pipe type
Fin type
Material
Colour
Liquid Φ6.35 (Φ 1/4 in.) Φ6.35 (Φ 1/4 in.)
Gas Φ 12.70 (Φ 1/2 in.) Φ 15.88 (Φ 5/8 in.)
Cooling
Heating °C 30 or less 30 or less
Cooling A A
Heating A A
kW 5.20 7.10
BTU/h 17700 24200
kW 0.90-5.90 0.90-8.00
BTU/h 3100-20100 3100-27300
kW 6.00 8.00
BTU/h 20500 27300
kW 0.90-7.50 0.90-9.10
BTU/h 3100-25600 3100-31000
kW
A
kW/kW
l/h (pints/h) 2.0 ( 3.5 ) 2.7 ( 4.8 )
High 780 980
Med 700 820
Low 560 680
Quiet 500 540
Quiet 500 540
Quiet 32(Floor console) , 31(Under ceiling) 36(Floor console) , 35(Under ceiling)
Quiet 32(Floor console) , 31(Under ceiling) 36(Floor console) , 35(Under ceiling)
m3/h
High 780 980
Med 700 820
Low 560 680
High 44(Floor console) , 43(Under ceiling) 49(Floor console) , 48(Under ceiling)
Med 41(Floor console) , 40(Under ceiling) 45(Floor console) , 44(Under ceiling)
Low 35(Floor console) , 34(Under ceiling) 41(Floor console) , 40(Under ceiling)
dB(A)
High 44(Floor console) , 43(Under ceiling) 49(Floor console) , 48(Under ceiling)
Med 41(Floor console) , 40(Under ceiling) 45(Floor console) , 44(Under ceiling)
Low 35(Floor console) , 34(Under ceiling) 41(Floor console) , 40(Under ceiling)
mm
mm
kg(lb.)
°C 18 to 32 18 to 32
%RH 80 or less 80 or less
mm
AB A18LAT, AB F18LAT
AO A18LACL, AO A18LALL AO A24LACL, AO A24LALL
FLOOR CEILING MODEL
INVERTER HEATPUMP
AB A24LAT, AB F24LAT
230V 50Hz
198-264V 50Hz
1.62 2.21
2.16 2.85
1.66 2.21
2.96 3.19
7.1 9.7
9.0 12.0
7.3 9.7
12.5 13.5
Sirocco × 2
Copper
Aluminium
ABS
White
199 × 990 × 655
324 × 1075 × 686
Wireless
ABS
Outer diameter : 26.0 / Inner diameter : 21.5
AB A18-24L
FLOOR / CEILING TYPE
- (01 - 05) -
Model name
Type
Drain pipe Material
ABS
Size
Outer diameter : 26.0 / Inner diameter : 21.5
Operation range Cooling Remote controller type
Wireless
Weight
kg(lb.)
Connection pipe Size
mm
Enclosure
ABS
White
Dimentions ( H× W ×D )
mm
199 × 990 × 655
324 × 1075 × 686
Heat exchanger type
mm
Copper
Aluminium
Sirocco × 2
Sound pressure level
Cooling
dB(A)
Heating
Fan Airflow
rate
Cooling
m3/h
Heating
Cooling
kW/kW
Heating
Moisture removal
Current
Cooling Rated
A
*Max.
Heating Rated
*Max.
Input power
Cooling Rated
kW
*Max.
Heating Rated
*Max.
European energy label
Capacity
Cooling
Rated
Min. - Max.
Heating
Rated
Min. - Max. Power source
230V 50Hz
Available voltage range
198-264V 50Hz
FLOOR CEILING MODEL
INVERTER HEATPUMP
AB A18-24L
FLOOR / CEILING TYPE
AB A18LAT, AB F18LAT
AO B18LACL, AO B18LALL AO B24LACL, AO B24LALL
Cooling B B
Heating B B
kW 5.20 7.10
BTU/h 17700 24200
kW 0.90-5.70 0.90-7.80
BTU/h 3100-19500 3100-26600
kW 6.00 8.00
BTU/h 20500 27300
kW 0.90-7.20 0.90-8.80
BTU/h 3100-24600 3100-30000
1.70 2.32
2.16 2.85
1.75 2.33
2.96 3.19
7.4 10.1
9.0 12.0
7.7 10.2
12.5 13.5
EER 3.06 3.06
COP 3.43 3.43
l/h (pints/h) 2.0 ( 3.5 ) 2.7 ( 4.8 )
High 780 980
Med 700 820
Low 560 680
Quiet 500 540
High 780 980
Med 700 820
Low 560 680
Quiet 500 540
Type × Q'ty
Motor output W 80 80
High 44(Floor console) , 43(Under ceiling) 49(Floor console) , 48(Under ceiling)
Med 41(Floor console) , 40(Under ceiling) 45(Floor console) , 44(Under ceiling)
Low 35(Floor console) , 34(Under ceiling) 41(Floor console) , 40(Under ceiling)
Quiet 32(Floor console) , 31(Under ceiling) 36(Floor console) , 35(Under ceiling)
High 44(Floor console) , 43(Under ceiling) 49(Floor console) , 48(Under ceiling)
Med 41(Floor console) , 40(Under ceiling) 45(Floor console) , 44(Under ceiling)
Low 35(Floor console) , 34(Under ceiling) 41(Floor console) , 40(Under ceiling)
Quiet 32(Floor console) , 31(Under ceiling) 36(Floor console) , 35(Under ceiling)
Dimensions (H × W × D) 252 × 800 × 39.9 252 × 800 × 53.2
Fin pitch 1.30 1.45
Rows x Stages 3 × 12 4 × 12
Pipe type
Fin type
Material
Colour
Net
Gross
Net 27 ( 60 ) 27 ( 60 )
Gross 36 ( 79 ) 36 ( 79 )
Liquid Φ6.35 (Φ 1/4 in.) Φ6.35 (Φ 1/4 in.)
Gas Φ 12.70 (Φ 1/2 in.) Φ 15.88 (Φ 5/8 in.)
Method Flare Flare
°C 18 to 32 18 to 32
%RH 80 or less 80 or less
Heating °C 30 or less 30 or less
AB A24LAT, AB F24LAT
AB A18-24L
FLOOR / CEILING TYPE
mm
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24°CWB. Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit) *The maximum current and the maximum input value are the maximum value when operated within the operation range(temperature)