General AUHA18L, AUHA18LALN, AOHA18LACL, AUHA24L, AUHA24LALN, AOHA24LACL Technical Manual
R410A
INDOOR UNIT
1. CASSETTE
AU A18LALN
AU A24LALN
TYPE :
D2D_AU024E/03
2007.10.19
1. FEATURE
MODELS :
CASSETTE TYPE
AU A18LALN
AU A18-24L
CASSETTE TYPE
AU A18-24L
AU A24LALN
FEATURES
ENERGY SAVING
• ALL DC DESIGN
• Heat exchange efficiency increased and larger air flow by adoption of new type turbo fan
ADVANCEMENT IN COMFORT
• Quiet operation was realized by adoption of new type turbo fan
• Improvement of air stream
IMPROVEMENT IN AIRFLOW RANGE (18 TYPE)
*Wind velocity at maximum point of airflow range is 0.5m/s
Conventional type
New type
EXPANSION OF AIR OUTLET ADJUSTMENT RANGE (18 TYPE)
Auto airflow direction and auto swing
Expanded air outlet range provides more comfortable space
2.5 m
3.0 m
New type
• The number of air outlet can be selected.
4-way direction3-way direction
• High ceiling mode
Air reaches sufficiently up to 3.5m height, even it is compact cassette type.
High ceiling
3.5m
- (01 - 01) -
CASSETTE TYPE
AU A18-24L
IMPROVEMENT OF INSTALLATION & MAINTENANCE
CASSETTE TYPE
AU A18-24L
• COMPACT DESIGN
Fits the European size ceiling.
New type
18 type
18 type
18kg
18kg
590
570
590
570
24 type
24 type
19kg
19kg
• EASY MAINTENANCE
Maintenance of fan motor and fan
Maintenance of fan motor and fan can be done
easily after taking off the panel,
since bell-mouth can be removed easily
A : Fan motor
B : 2 stage turbo fan
C : Bell-mouth
D : Panel
Long life filter
: standard equipment
A
B
C
D
Adaptation of transparent drainage parts
Grille cover
Easy check of operation of drain-up kit
When you install
EASY INSTALLATION
New type
Easy setting by wireless or
wired remote controller
OTHER FUNCTIONS
• SETTING THE FILTER SIGN
THE INDOOR UNIT HAS SIGN TO IMFORM THE USER THAT IT IS TIME TO CLEAN THE FILTER
• SETTING THE COOLER ROOM TEMPERATURE CORRECTION
• SETTING THE HEATER ROOM TEMPERATURE CORRECTION
• AUTO RESTART
- (01 - 02) -
2. COMBINATION
2-1. OUTDOOR UNIT
CASSETTE TYPE
AU A18-24L
MODELS :
AO A18LACL
AO A24LACL
2-2. REMOTE CONTROLLER
2-2-1. WIRED REMOTE CONTROLLER
MODEL : UTB- UD
CASSETTE TYPE
AU A18-24L
2-2-2. WIRELESS REMOTE CONTROLLER
MODEL : UTB- NA
2-3. DECORATION PANEL
MODEL : UTG-UF A-W
CAUTION
Remote controller and decoration panel are not supplied with the indoor unit.
Separate purchase is necessary.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
Ceiling mode : Standard