● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain save operating conditions.
● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.
En-1
DANGER!
CAUTION!
● Do not attempt to install this air conditioner by yourself.
● This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the unit.
● Do not become over-exposed to cold air by staying in the direct path of the airflow of
the air conditioner for extended periods of time.
● Do not insert fingers or objects into the outlet port or intake grilles.
● Do not start and stop air conditioner operation by turning off the electrical breaker
and so on.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the electrical breaker, and consult authorized service personnel.
● Provide occasional ventilation during use.
● Do not direct air flow at fireplaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not set flower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Turn off power source when not using the unit for extended periods.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the air flow.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
● Do not apply any heavy pressure to radiator fins.
● Operate only with air filters installed.
● Do not block or cover the intake grille and outlet port.
● Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
● Avoid installing the air conditioner near a fireplace or other heating apparatus.
●
When installing the indoor and outdoor unit, take precautions to prevent access to infants.
● Do not use inflammable gases near the air conditioner.
● Connection valves become hot during Heating; handle with care.
● Always turn off the electrical breaker whenever cleaning the air conditioner or chang-
ing the air filter.
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
● COOLING MODEL
Merely press the START/STOP button, and the unit will
begin automatic operation in the Cooling or Dry mode as
appropriate, in accordance with the thermostat setting
and the actual temperature of the room.
● HEAT & COOL MODEL (REVERSE CYCLE)
Merely press the START/STOP button, and the unit will
begin automatic operation in either the Heating, Cooling
or Monitor modes as appropriate, in accordance with the
thermostat setting and the actual temperature of the
room.
SLEEP TIMER
● COOLING MODEL
When the SLEEP timer button is pressed during Cooling
or Dry mode, the thermostat setting is gradually raised
during the period of operation. When the set time is
reached, the unit automatically turns off.
● HEAT & COOL MODEL (REVERSE CYCLE)
When the SLEEP timer button is pressed during Heating
mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling or Dry mode, the thermostat setting is gradually raised
during the period of operation. When the set time is
reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient
control of air conditioner operation.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.
En-2
NAME OF PARTS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Lights during use of the ON timer, OFF timer,
PROGRAM timer, and SLEEP timer.
6 OPERATION Indicator Lamp (red)
● Lights when unit is in operation.
● Flashes quickly for about one second when
a signal is received from the remote con-
trol unit.
[When the OPERATION indicator and TIMER
indicator flash alternately, it means that the
power has been interrupted due to a power
failure, etc.]
7 Remote Control Signal Receiver
8 MANUAL AUTO Button
9 Air Intake Grille
Fig. 3 Outdoor Unit
; Intake Port
A Outlet Port
B Pipe Unit
C SLEEP Button
D MASTER CONTROL Button
E SET TEMP./SET TIME Buttons ()
F Signal Transmitter
G TIMER Button
H FAN CONTROL Button
I START/STOP Button
J Battery compartment lid
Inside of the battery compartment lid (Fig. 5)
K AIR FLOW DIRECTION Button
L ENERGY SAVE Button
M CODE CHANGE (Slide Switch)
Switching the remote control unit code.
(Max. 4 units)
N TIME ADJUST Button
O TEST RUN Button
● This button is used when installing the air
conditioner and should not be used under
normal conditions as it will cause the air
conditioner’s thermostat function to oper-
ate incorrectly.
● If this button is pressed during normal operation, the unit will switch to test operation mode, and the indoor unit’s OPERATION indicator lamp and TIMER indicator
lamp will begin to flash simultaneously.
● To stop the test operation mode, either
press the TEST RUN button once again, or
press the START/STOP button to stop the
air conditioner.
P ACL Button
Q Remote Control Unit Display (Fig. 6)
R Transmit Indicator
S Clock Display
T Operating Mode Display
U Timer Mode Display
V Fan Speed Display
W Temperature Set Display
X Timer Set Indicator
Y Temperature Set Indicator
En-4
PREPARATION
Load Batteries (R03/LR03
××
× 4)
××
Open the battery compartment lid.
1
1 Slide the battery compartment lid until it stops.
2 While strongly gripping the portion on each side of the battery com-
partment lid that has a rough surface, slide the lid until it comes completely off.
Insert batteries.
2
Be sure to align the battery polarities () correctly.
Close the battery compartment lid.
3
Set the Current time
Press the TIME ADJUST button.
1
Use the tip of a ball-point pen or other small object to press the button.
1
2
2
2
CAUTION!
● Take care to prevent infants from
accidentally swallowing batteries.
● When not using the remote control unit
for an extended period, remove the
batteries to avoid possible leakage and
damage to the unit.
● If leaking battery fluid comes in contact
with your skin, eyes, or mouth, immediately wash with copious amounts of
water, and consult your physician.
● Dead batteries should be removed
immediately and disposed of properly,
either in a battery collection receptacle
or to the appropriate authority.
● Do not attempt to recharge dry batteries.
Never mix new and used batteries, or
batteries of different types.
Batteries should last about one year
under normal use. If the remote control
unit’s operating range becomes appreciably reduced, replace the batteries and
press the ACL button with the tip of a
ballpoint pen or other small object.
Use the ()SET TIME buttons to adjust the clock to
2
the current time.
button: Press to advance the time.
button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in
one-minute increments; hold the buttons depressed to change the time
quickly in ten-minute increments.)
Press the TIME ADJUST button again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
● The remote control unit must be pointed at signal receiver to operate correctly.
● Operating range: About 7 meters.
● When a signal is properly received by the air conditioner, a beeping sound will
be heard.
● If no beep is heard, press the remote control unit button again.
Remote Control Unit Holder
For use as Handy Type
Insert
Slide up
For use as Wall Fixing Type
Insert
SET
SWING
ENERGY
SAVE
SET
AIR FLOW
DIRECTION
TIME
TEST
ADJUST
SWING
RUN ACL
Screws
1 Mount the Holder.
En-5
2 Set the Remote
Control Unit.
3 To remove the
Remote Control
Unit (when use at
hand).
Screws
Screw
1 Mount the Holder.3 Attach the unit to
2 Set the Remote
Control Unit.
the holder as
shown.
Slide
Loading...