General AG*F09LA, AG*F09LAC, AO*V09LAC, AG*F12LA, AG*F12LAC User Manual

...
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM K‹TABI
ROOM AIR CONDITIONER
English
FLOOR TYPE
HEAT & COOL MODEL (REVERSE CYCLE)
Deutsch
Français
Español
Italiano
EλληvIkά
KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE
Português
Русский
Türkçe
P/N9378532014
Fig. 1
1
1
D
G B
C
A =
E
2 3
Fig. 2
4
4
TIMER6OPERATION5810˚c HEAT
F
7
Fig. 3
9
9
Fig. 4
Fig. 5
I J
K L
H
N W
MODEMODE
10˚c HEAT10˚c HEAT
ECONOMYECONOMY
SWING
M
P R Q
S
T
U O V
X
a
[
\
Y
`
d
b c
]
Z
Fig. 6
To facilitate explanation, the accompanying illustra­tion has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current op­eration.
CONTENTS
SAFETY PRECAUTIONS .................................... En-1
FEATURES AND FUNCTIONS ........................... En-2
NAME OF PARTS ................................................ En-3
PREPARATION .................................................... En-4
OPERATION ........................................................ En-5
TIMER OPERATION ............................................ En-7
SLEEP TIMER OPERATION ................................ En-8
ADJUSTING THE DIRECTION OF
AIR CIRCULATION .............................................. En-9
SAFETY PRECAUTIONS
WARNING!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.
Do not insert anything into the Airflow direction.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-
connect the power supply plug, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specified cord are required.
AIR OUTLET SELECTION ................................. En-10
10°C HEAT OPERATION ................................... En-11
ECONOMY OPERATION................................... En-11
SWING OPERATION......................................... En-12
COIL DRY OPERATION ..................................... En-12
MANUAL AUTO OPERATION.......................... En-12
CLEANING AND CARE ..................................... En-13
TROUBLESHOOTING ....................................... En-15
OPERATING TIPS.............................................. En-17
CAUTION!
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Connection valves become hot during Heating; handle with care.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
Do not use inflammable gases near the air conditioner.
Do not sit and place anything on the unit.
En-1
FEATURES AND FUNCTIONS
INVERTER
At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for eco­nomic and comfortable operation.
COIL DRY OPERATION
The Indoor unit can be dried by pressing the COIL DRY but­ton on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched au­tomatically to maintain the set temperature, and the tem­perature is kept constant at all times.
10°C HEAT OPERATION
The room temperature can be maintained at 10°C so as to prevent the room temperature from falling too far.
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour pe­riod.
SLEEP TIMER
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.
REMOVABLE OPEN PANEL
The indoor unit’s Open Panel can be removed for easy clean­ing and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s air­flow is reduced to produce quieter operation.
POLYPHENOL CATECHIN AIR CLEANING FILTER
The polyphenol catechin air cleaning filter uses static elec­tricity to clean the air of fine particles and dust such as to­bacco smoke and plant pollen that are too small to see. The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed by the filter. Note that when the air cleaning filter is installed, the amount of air produced decreases, causing a slight decrease in the air conditioner's performance.
When the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automati­cally turns off.
WIRELESS REMOTE CONTROL UNIT
The Wireless Remote Control Unit allows convenient con­trol of air conditioner operation.
NEGATIVE AIR IONS DEODORIZING FILTER
It comprises pottery super micro particles, which can pro­duce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.
En-2
NAME OF PARTS
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 Air Outlet Selection switch 3 MANUAL AUTO button
When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.
The forced cooling operation is used at the
time of installation. Only for authorized service personnel's use.
When the forced cooling operation starts
by any chance, press the START/STOP but­ton to stop the operation.
4 Indicator (Fig. 3) 5 Remote Control Signal Receiver 6 OPERATION Indicator Lamp (green) 7 TIMER Indicator Lamp (orange)
If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 16 Auto Restart).
8 10°C HEAT Indicator Lamp (green)
9 Intake Grille (Fig. 4) 0 Front Panel A Air Filter B Air Flow Direction Louver C Damper D Right-Left Louver
(behind Air Flow Direction Louver and Damper)
E Drain Hose F Air Cleaning Filter G Rope
Fig. 5 Remote Control Unit
H SLEEP button I MODE button J 10°C HEAT button K SET TEMP. button (
/ )
L COIL DRY button M Signal Transmitter N TIMER MODE button O TIMER SET (
/ ) button
P FAN CONTROL button Q ECONOMY button R START/STOP button S SET button T SWING button U RESET button V TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioner’s thermostat function to op­erate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Unit’s OPERA­TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, press the START/STOP button to stop the air condi­tioner.
W CLOCK ADJUST button X Remote Control Unit Display (Fig. 6) Y Transmit Indicator Z Clock Display [ ECONOMY Display \ Operating Mode Display ] Timer Mode Display ` Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display
Refer to the folded out page on the cover.
En-3
PREPARATION
Load Batteries (R03/LR03
××
× 2)
××
Press and slide the battery compartment lid on the re-
1
verse side to open it.
Slide in the direction of the arrow while pressing the mark.
Insert batteries.
2
Be sure to align the battery polarities ( ) correctly.
Close the battery compartment lid.
3
Set the Current time
Press the CLOCK ADJUST button (Fig. 5 W).
1
Use the tip of a ball-point pen or other small object to press the button.
Use the TIMER SET ( / ) buttons (Fig. 5 O) to
2
adjust the clock to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the Remote Con­trol Unit’s operating range becomes ap­preciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object.
Press the CLOCK ADJUST button (Fig. 5 W) again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The Remote Control Unit must be pointed at signal receiver (Fig. 1 5) to operate correctly.
Operating Range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will be
heard.
If no beep is heard, press the Remote Control Unit button again.
Remote Control Unit Holder
Insert
Press in
Screws
1 Mount the Holder. 2 Set the Remote Control
Unit.
Slide up
Pull out
3 To remove the Remote
Control Unit (when use at hand).
En-4
OPERATION
To Select Mode Operation
Press the START/STOP button (Fig.5 R).
1
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 6) will light. The air conditioner will start operating.
Press the MODE button (Fig.5 I) to select the desired
2
mode.
Each time the button is pressed, the mode will change in the following order.
sss
AUTO COOL DRY
About three seconds later, the entire display will reappear.
HEAT FAN
tt
To Set the Thermostat
Press the SET TEMP. button (Fig. 5 K).
button: Press to raise the thermostat setting. button: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. 18-30 °C
Heating ............................... 16-30 °C
The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the Remote Control Unit’s Display).
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
Cooling/Dry ........................ 18-30 °C
To Set the Fan Speed
Press the FAN CONTROL button (Fig. 5 P).
Each time the button is pressed, the fan speed changes in the following order:
AUTO HIGH MED LOW QUIET
About three seconds later, the entire display will reappear.
When set to AUTO:
Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan : The fan runs at the low fan speed.
The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.
ssss
s
Example: When set to COOL.
Example: When set to 26 °C.
Example: When set to AUTO.
SUPER QUIET Operation
SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for qui­eter operation.
SUPER QUIET operation cannot be used during Dry mode. (The same is true when dry mode is selected during AUTO mode operation.)
During Super Quiet operation, Heating and Cooling performance will be reduced somewhat. If the room does not warm up/ cool down when using SUPER QUIET Operation, please adjust the air conditioner’s Fan Speed.
En-5
To Stop Operation
Press the START/STOP button (Fig. 5 R).
The OPERATION Indicator Lamp (green) (Fig. 3 6) will go out.
About AUTO CHANGEOVER Operation
AUTO: When AUTO CHANGEOVER operation first selected, the fan will oper-
ate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.
If the differance between thermostat setting and actual room tempera­ture is more than +2 °C Cooling or dry operation
If the difference between thermostat setting and actual room tempera­ture is within ±2 °C Monitor operation If the difference between thermostat setting and actual room tempera­ture is more than –2 °C Heating operation
When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room tem­perature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the tem­perature to the value set in the thermostat.
(The monitor operation range is ±2 °C relative to the thermostat set­ting.)
If the mode automatically selected by the unit is not what you wish, select one of the mode operation (HEAT, COOL, DRY, FAN).
About Mode Operation
Heating: Use to warm your room.
When Heating mode is selected, the air conditioner will operate at very low fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.
When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION Indica­tor Lamp (Fig. 3 6) will flash, and the heat operation will be inter­rupted.
Cooling: Use to cool your room.
Dry: Use for gently cooling while dehumidifying your room.
You cannot heat the room during Dry mode.
During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.
The fan speed cannot be changed manually when Dry mode has been selected.
Fan: Use to circulate the air throughout your room.
During Heating mode:
Set the thermostat to a temperature set­ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.
During Cooling/Dry mode:
Set the thermostat to a temperature set­ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper­ate).
During Fan mode:
You can not use the unit to heat and cool your room.
En-6
TIMER OPERATION
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (☞ P. 4).
To Use the ON timer or OFF timer
Press the START/STOP button (Fig. 5 R)
1
(if the unit is already operating, proceed to step 2).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 6) will light.
Press the TIMER MODE button (Fig. 5 O) to select the
2
OFF timer or ON timer operation.
Each time the button is pressed the timer function changes in the follow­ing order:
ss
CANCEL OFF ON
PROGRAM(OFF ON, OFF ON)
The indoor unit’s green TIMER Indicator Lamp (orange) (Fig. 3 7) will light.
s
t
Use the TIMER SET buttons (Fig. 5 O) to adjust the
3
desired OFF time or ON time.
Set the time while the time display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Use the Program timer
To Cancel the Timer
Use the TIMER button to select “CANCEL”. The air conditioner will return to normal operation.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.
Press the START/STOP button (Fig. 5 R).
1
(if the unit is already operating, proceed to step 2).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 6) will light.
Set the desired times for OFF timer and ON timer.
2
See the section “To Use the ON timer or OFF timer” to set the desired mode and times. About three seconds later, the entire display will reappear. The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 7) will light.
Press the TIMER MODE button (Fig. 5 N) to select the
3
PROGRAM timer operation (OFF
ON or OFF ON
will display).
The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur first.
The program timer will begin operation. (If the ON timer has been se-
lected to operate first, the unit will stop operating at this point.)
About five seconds later, the entire display will reappear.
About the Program timer
The program timer allows you to integrate OFF timer and ON timer operations in
a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.
The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Control Unit’s Display (OFF ON, or OFF ON).
One example of Program timer use might be to have the air conditioner auto-
matically stop (OFF timer) after you go to sleep, then start (ON timer) automati­cally in the morning before you arise.
En-7
To Cancel the Timer
Use the TIMER MODE button to select “CANCEL”. The air conditioner will return to normal operation.
To Change the Timer Settings
Follow the instructions given in the section
1. “To Use the ON Timer or OFF Timer” to se­lect the timer setting you wish to change.
2. Press the TIMER MODE button to select either OFF ON or OFF ON.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reap­pears, then press the appropriate buttons to change the operating condition desired.
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP Timer
While the air conditioner is operating or stopped, press the SLEEP button (Fig. 5 H).
The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 6) lights and the TIMER Indicator Lamp (orange) (Fig. 3 7) light.
To Change the Timer Settings
Press the SLEEP button (Fig. 5 H) once again and set the time using the TIMER SET (
Set the time while the Timer Mode Display is flashing (the flashing will continue about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP Timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.
/ ) buttons (Fig. 5 O).
To Cancel the Timer:
Use the TIMER MODE button to select “CANCEL”. The air conditioner will return to normal operation.
To Stop the Air Conditioner During Timer Operation:
Press the START/STOP button.
During Heating operation:
When the SLEEP timer is set, the thermostat setting is automatically lowered 1 °C every thirty minutes. When the thermostat has been lowered a total of 4 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
30 minutes
1 hour
1 hour 30 minutes
1 °C
2 °C
Set time
3 °C
4 °C
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto­matically raised 1 °C every sixty minutes. When the thermo­stat has been raised a total of 2 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
Set time
1 hour
1 °C
2 °C
En-8
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
Vertical Air Direction Adjustment
Press the SET button (Fig. 5 S).
Each time the button is pressed, the air direction range will change as follows:
1 2 3 4 5
The Remote Control Unit’s display does not change.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Upward flow 1
During Heating mode : Horizontal flow 4
During AUTO mode operation, for the first minute after beginning operation, airflow will be upward 1; the air direction cannot be adjusted during this period.
During Heating mode operation, airflow will be upward 1 when the temperature of the air issued from the indoor is low.
1
2
3
4
5
R
WARNING!
Never place fingers or foreign objects in­side the outlet ports, since the internal fan operates at high speed and could cause personal injury.
Always use the Remote Control Unit’s SET button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper op­eration; in this case, stop operation and restart. The louvers should begin to operate properly again.
When used in a room with infants, chil­dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.
When indoor unit is embedded in a wall, air flow is fixed to horizontal di­rection 5. Please ask the service personnel to per­form the embedding in a wall.
Right-Left Adjustment
Adjust the Right-Left louvers.
Move the Right-Left louvers to adjust air flow in the direction you prefer.
En-9
R
WARNING!
Always adjust the Right-Left louvers when the damper is open. Opening the damper forcibly with hands can cause damper of malfunction.
AIR OUTLET SELECTION
With this function , air come out simultaneously from the upper and lower air outlets so that the room can be cooled or heated effectively. This function is set using the switch behind the front grille of the Indoor unit. (This function is available in cooling and heating operation.)
How to set to blow out air from the upper and lower air outlets
Set the air outlet selection switch to
Air blows out automatically from the upper and lower air outlets as shown in the table below.
NOTE:
Set the air outlet selection switch to the end. Otherwise, air outlet cannot be selected as intended.
Description of operation
Operation COOLING Mode DRY Mode HEATING Mode
Air flow
Conditions
Upper and lower air flow
Room tempera­ture and set tem­perature are dif­ferent.
Upper air flow Upper air flow
only
Room tempera­ture is close to set temperature, or the air conditioner has operated for 1hour.
How to set to blow out air from the upper air outlet only
Set the air outlet selection switch to
Upper and lower air flow
Air flow tempera­ture is high.
_
Upper air flow
Air flow tempera­ture is low. (During defrost­ing operation, start of operation, etc.)
En-10
10°C HEAT OPERATION
The room temperature can be maintained at 10°C by pressing the 10°C HEAT button (Fig.5 J) so as to prevent the room temperature from falling too far.
To use 10°C HEAT OPERATION
Press the 10°C HEAT button (Fig.5 J)
The indoor unit’s 10°C HEAT Indicator lamp (green)(Fig.3 8) will light.
The direction of AIR flow is set to horizontal.
To stop 10°C HEAT OPERATION
Press the START/STOP button (Fig.5 R)
The indoor unit’s 10°C HEAT Indicator lamp (green)(Fig.3 8) will go out. Then the operation stops.
About the 10°C HEAT OPERATION
The Heating mode will not operate if the room temperature is high enough.
After the 48 hours of 10°C HEAT OPERATION, the FAN mode will be fixed at High
speed.
ECONOMY OPERATION
Begin Air Conditioner operation before performing this procedure.
To Use the ECONOMY Operation
Press the ECONOMY button (Fig.5 Q).
“ECO” appears on the Remote Control Unit display. Economy operation begins.
While 10˚C HEAT OPERATION is in progress, the following operations/ features cannot be used
• TIMER
• SLEEP
• Air flow direction
• FAN speed
• Swing
To Stop the ECONOMY Operation
Press the ECONOMY button (Fig.5 Q) again.
“ECO” disappears from the Remote Control Unit display. Normal operation begins.
About ECONOMY Operation
At the maximum output, ECONOMY Operation is approximately 70% of normal air conditioner operation for cooling and heating.
• When ECONOMY operation is performed during the cooling mode, dehumidification is improved. This function is especially convenient when you want to remove the humidity in the room without significantly lowering the room temperature.
• During ECONOMY operation, the thermostat setting automatically changes according to the temperature to avoid Unneces­sary cooling and heating for the most economical operation.
If the room is not cooled (or heated) well during economy operation, select normal operation.
Once air conditioner operation is stopped, normal operation begins when the indoor unit is turned on again.
During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY operation even if
ECONOMY operation is selected by pressing the ECONOMY operation button.
En-11
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING button (Fig. 5 T).
The SWING Display (Fig. 6 d) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.
To stop SWING Operation
Press the SWING button (Fig. 5 T) once again.
The SWING Display (Fig. 6 d) will go out. Airflow direction will return to the setting before swing was begun.
About Swing Operation
Swings between 1 and 5.
The SWING operation may stop temporarily when the air conditioner’s fan is not
operating, or when operating at very low speeds.
COIL DRY OPERATION
The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium. The COIL DRY Operation will operate for 48 minutes after pressing the COIL DRY button and it will stop automatically.
To select COIL DRY Operation
Press the COIL DRY button (Fig. 5 L) during operation or when it stops.
The COIL DRY Display (Fig. 6 b) will light. Then it will disappear after 48 minutes.
To cancel COIL DRY Operation
Press the START/STOP button (Fig. 5 R) during COIL DRY Operation.
The COIL DRY Display (Fig. 6 b) will go out . Then the operation stops.
About COIL DRY Operation
Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera-
tion can be reset.
The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it
has no sterilization effect either.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 3) on the main unit control panel.
To stop operation, press the MANUAL AUTO button (Fig. 2 3) once again. (Controls are located inside the Open Panel)
When the air conditioner is operated with the controls on the Main Unit, it will operate under the same mode as the AUTO mode selected on the Re­mote Control Unit (see page 6).
The fan speed selected will be “AUTO” and the thermostat setting will be standard. (24
°C)
En-12
CLEANING AND CARE
CAUTION!
Before cleaning the air conditioner, be sure to turn it off.
Be sure the Intake Grille (Fig. 1 9) is installed securely.
When removing and replacing the air filter, be sure not to touch the heat exchanger, as personal
injury may result.
Cleaning the Intake Grille
1. Remove the Intake Grille.
1 Place your fingers at both top indicator of the grille
panel, and pull forward; if the grille seems to catch partway through its movement, continue pulling down to remove.
2 Unhook the ropes which holds the grille.
1
Intake Grille
2
2
Rope
1
2. Clean with water.
Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth.
3. Replace the Intake Grille.
1 Hook the ropes. 2 Set the left and right mounting shafts into the bear-
ings at the bottom of the panel.
3 Press the place where the mark on the diagram indi-
cates and close the Intake Grille.
Cleaning the Air Filter
1. Open the Intake Grille, and remove the air filter.
Push down the air filter’s handle, disconnect the two up­per tabs, and pull out.
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the Air Filter and close the Intake Grille.
1 Align the sides of the air filter with the panel, and push
in fully, making sure the two upper tabs are returned properly to their holes in the panel.
AIR FILTER
AIR FILTER
PANEL
PANEL
2 Close the Intake Grille.
Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
2
Intake Grille
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.
1
3
Rope
2
1
3
tergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before rein­stalling.
If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increas­ing noise.
During periods of normal use, the Air Filters should be cleaned every two weeks.
En-13
CLEANING AND CARE
Air Cleaning Filter Installation
1. Open the Intake Grille and remove the Air filter.
2. Install the Air cleaning filter set (set of 2).
Set the air cleaning filter into the panel. Catch it on five places of picks. (Three places of upper parts and lower part two places.)
Replacing dirty Air cleaning filters
Replace filters with the following components (purchased separately).
POLYPHENOL CATECHIN AIR CLEANING FILTER
Negative air ions deodorizing filter: UTR-FC03-3
: UTR-FC03-2
1. Open the Intake Grille and remove the Air filter.
2. Replace them by two new Air cleaning filters.
1 Remove the old air cleaning filters in reverse order of
their installation.
2 Install in the same way as for installation of the air
cleaning filter set.
3. Install the Air filter and close the Intake Grille.
Air cleaning filter
3. Install the Air filter and close the Intake Grille.
When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.
In regard to the Air Cleaning Filters
POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)
The Air Cleaning Filters are disposable filters. (They can not be washed and reused.)
For storage of the Air Cleaning Filters, use the filters as soon as possible after the package has been opened. (The air cleaning effect decreases when the filters are left in the opened package)
Generally, the filters should be exchanged about every three months.
Please buy delicated air cleaning filters (UTR-FC03-2) (Sold separately) to exchange the used dirty air cleaning filters.
[Negative air ions deodorizing filter (one sheet) — light blue]
The filters should be exchanged about every three years so as to maintain the deodorizing effect.
Please buy delicated deodorizing filter (UTR-FC03-3) (Sold separately) when exchanging the filters.
Maintenance of Deodorizing Filters
In order to maintain the deodorizing effect, please clean the filter in the follow way once three months.
1 Remove the deodorizing filter. 2 Clean with water and dry in the air.
1) Flush the filters with high-pressure hot water until the surface of the filters are covered with water. Please flush with diluent neutral detergent. Never wash by reaming or rubbing, otherwise it will damage the deodorizing effect.
2) Rinse with water flow.
3) Dry in shade.
3 Reinstall the deodorizing filter.
En-14
TROUBLESHOOTING
WARNING!
Before requesting service, perform the following checks:
NORMAL
FUNCTION
Doesn’t operate immedi­ately:
Noise is heard:
Smells:
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec­trical breaker or disconnect the power supply plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off.
Symptom
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
Whenever the electrical breaker is turned off than on again or the
power supply plug is disconnected and then reconnected, the pro­tection circuit will operate for about 3 minutes, preventing unit operation during that period.
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioner’s piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
During Heating operation, a sizzling sound may be heard occasional.
This sound is produced by the Automatic Defrosting operation.
Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
Problem
See Page
16
Mist or steam are emitted:
Airflow is weak or stops:
During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation.
When Heating operation is started, fan speed is temporarily very low, to allow internal parts to warm up.
During Heating operation, if the room temperature rises above the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat for a higher setting.
During Heating operation, the unit will temporarily stop opera­tion (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the OPERATION Indicator Lamp will flash.
The fan may operate at very low speed during Dry operation or when the unit is monitoring the room’s temperature.
During SUPER QUIET operation, the fan will operate at very low speed.
In the monitor AUTO operation, the fan will operate at very low speed.
16
16
5
5
5
En-15
Water is produced from the outdoor unit:
During Heating operation, water may be produced from the out­door unit due to Automatic Defrosting operation.
16
TROUBLESHOOTING
NORMAL
FUNCTION
CHECK ONCE
MORE
Symptom
The damper opens and closes automatically
Symptom
Doesn’t operate at all:
Poor performance:
Problem
The damper is automatically controlled by a microcomputer ac­cording to the air flow temperature and operation time of the air conditioner.
Items to check
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the Air Filter dirty?
Air the air conditioner’s intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
Make sure the lower air outlet is not choked with foreign matters, causing abnormal operation to damper.
Is the unit set for SUPER QUIET operation?
See Page
See Page
7 - 8
5
The unit operates differently from the Remote Control Unit’s setting:
If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (Fig. 3 6) and the TIMER Indicator Lamp (Fig. 3 7) flashes, immediately stop operation, and consult authorized service personnel.
When the OPERATION Indicator Lamp (Fig.3 6) and the 10°C HEAT Indicator Lamp (Fig.3 8) flashes, the operation can be
maintained temporary by changing of air outlet selection switch to STOP button.
(If the damper does not close automatically, close the damper manually and fix the position by an adhesive tape etc.) The unit operates almost the same as upper air flow operation, however the indicator lamp flashes continuously if same symptom is detected again. Therefore, consult an authorized service personnel for the complete functional repair.
Are the Remote Control Unit’s batteries dead?
Are the Remote Control Unit’s batteries loaded properly?
, closing the damper completely and press the START/
4
En-16
OPERATING TIPS
Operation and Performance
Heating Performance
This air conditioner operates on the heat-pump princi­ple, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con­ditioner until the room is heated.
AUTO Restart
In Event of Power Interruption
The air conditioner power has been interrupted by a power failure. The air conditioner will then restart auto­matically in its previous mode when the power is restored.
Operated by setting before the power failure.
Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per­formance.
In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto­matic Defrosting function. If frost forms, the air condi­tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7-15 minutes).
During Automatic Defrosting operation, the OPERATION Indicator Lamp (green) will flash.
If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp will flash (see Page. 3).
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.
Temperature and Humidity Range (Exclude multi-type Air conditioner)
Cooling Mode
Outdoor temperature
Indoor temperature
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath. (About 80% or more)
About –10 to 43 °C
About 18 to 32 °C
Dry Mode
About –10 to 43 °C
About 18 to 32 °C
Heating Mode
About –15 to 24 °C
About 30 °C or less
Multi-type Air conditioner
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
En-17
OPERATING TIPS
Simultaneous Use of Multiple Units
When using a multi-type air conditioner, the multiple indoor units can be operated simultaneously, but when two or more indoor units of the same group are oper­ated simultaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone. Accordingly, when you wish to use more than one in­door unit for cooling at the same time, the use should be concentrated at night and other times when less out­put is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heaters, as required.
Seasonal and outdoor temperature conditions, the struc­ture of the rooms and the number of persons present may also result in differences of operating efficiency. We recommend that you try various operating patterns in order to confirm the level of heating and cooling out­put provided by your units, and use the units in the way that best matches your family’s lifestyle.
If you discover that one or more units delivers a low level of cooling or heating during simultaneous opera­tion, we recommend that you stop simultaneous opera­tion of the multiple units.
Operation cannot be done in the following different op­erating modes.
If the indoor unit is instructed to do an operating mode that it cannot perform, the OPERATION indicator lamp (green) on the indoor unit will flash (1 second on, 1 sec­ond off) and the unit will go into the standby mode.
Heating (COIL DRY) mode and cooling mode (or dry mode)
Heating (COIL DRY) mode and fan mode
Operation can be done in the following different operat­ing modes.
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
Heating mode and COIL DRY mode
The operating mode (heating (COIL DRY) mode or cool­ing (dry) mode) of the outdoor unit will be determined by the operating mode of the indoor unit that was oper­ated first. If the indoor unit was started in fan mode, the operating mode of the outdoor unit will not be deter­mined.
For example, if indoor unit (A) was started in fan mode and then indoor unit (B) was then operated in heating mode, indoor unit (A) would temporarily start opera­tion in fan mode but when indoor unit (B) started oper­ating in heating mode, the OPERATION indicator lamp (green) for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode. Indoor unit (B) would continue to operate in heating mode.
Notice
During use of the heating mode, the outdoor unit will occasionally commence the defrost operation for brief periods. During the defrosting operation, if the user sets the indoor unit for heating again, the defrosting mode will continue, and the heating operation will begin after completion of defrosting, with the result that some time may be required before warm air is emitted.
During use of the heating mode, the top of the indoor unit may become warm, but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped; it is not a malfunction.
En-18