AB A18LATAO A18LACLAO B18LACL
AB F18LATAO A18LALLAO B18LALL
AB A24LATAO A24LACLAO B24LACL
AB F24LATAO A24LALLAO B24LALL
FEATURES
Energy saving rank A
European energy ranking rank A achieved by all DCization and optimization of the refrigerant cycle
Quiet operation
Air flow mode can be set in 4 steps and more detailed air flow setting is possible
Filter sign
Dirtying of filter is detected by air conditioner operating time and the user is informed
ECONOMY operation
(AO A18LACL, AO A18LALL, AO A24LACL, AO A24LALL connection model)
AB A18-24L
FLOOR / CEILING TYPE
Operation that suppresses maximum power consumption is performed
Wired/wireless simultaneous use possible
Wired remote controller and wireless remote controller can be simultaneously used.
Flexible installation
FLOOR
CEILING
Double auto swing
Combination of up/down and right/left air
direction swing allows three-dimensional air
direction control.
Since up/down air direction flaps operate
automatically, according to the operating
mode of the unit, it is possible to set the air
direction based on the operating mode.
RIGHT and LEFT
swing
UP and DOWN
swing
5 steps selectable
- (01 - 01) -
Swing
Steps
7 steps selectable
FUNCTION SETTING
FLOOR / CEILING TYPE
AB A18-24L
Filter sign operating time (Standard/long/short/no display)
Filter sign display time interval and filter sign no display can be selected.
Ceiling height (standard/high ceiling)
Air conditioner operation capacity (air flow) switching is possible as response to height of installation ceiling.
Cooling room temperature correction (Standard/low control)
Air conditioner control temperature can be switched to a little low as response to installation conditions.
Heating room temperature correction (Standard/low/slightly high/high control)
Air conditioning control temperature can be slightly adjusted as response to installation conditions.
Auto restart (ON/OFF)
ON/OFF of the function which automatically resets operation to the operation state before the power
interruption at power recovery when there was a power interruption during operation can be selected.
Room temperature sensing function (ON/OFF) only at wired remote controller connection
Sensor which controls the room temperature can be selected in two types: "Indoor sensor only" or
"Indoor sensor or wired remote controller sensor can be switched by remote controller operation".
FLOOR / CEILING TYPE
AB A18-24L
- (01 - 02) -
12
2. REMOTE CONTROLLER
WIRELESS REMOTE CONTROLLER
FLOOR / CEILING TYPE
AB A18-24L
FEATURES
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
FLOOR / CEILING TYPE
AB A18-24L
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to the
time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Simultaneously operation
After code change
Mixed-up
• Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
ABCD
AB
C
1. Press the MODE button for
more than five seconds
to start the code change.
D
•Wide and precise
transmitting range.
- (01 - 03) -
2. Press the or button to
select the desired code.
A B C D
3. Press the MODE button
again to end the code change.
FLOOR / CEILING TYPE
AB A18-24L
FUNCTIONS
1
3
2
4
5
11
13
16
10
14
12
15
FLOOR / CEILING TYPE
1
MODE button
Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY).
/Start / end R.C. custom code change. (Max 4 types)
2
Economy button
3
Set temp. button ( / )
AB A18-24L
Set remote controller custom code buttons
Sets the indoor temp./ Sets R.C. custom code.
4
Filter reset button
5
Sleep button
Pressed to select sleep timer.
6
6
7
8
9
Fan button
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
7
START/STOP button
Pressed to start and stop operation.
8
Set button (Vertical)
Air flow direction vertical set button.
9
Set button (Horizontal)
Air flow direction horizontal set button.
10
Swing button
Air flow direction swing button.
11
Timer mode button
Pressed to select the timer mode. (OFF TIMER, ON TIMER,
PROGRAM TIMER, TIMER RESET)
Display panel
17
18
19
20
21
22
23
24
25
12
Timer set ( / ) button
Sets the current time and on-off time.
13
Clock adjust button
Sets the current time.
14
Reset button
Used when replacing batteries.
15
Test run button
Used when testing the air conditioner after installation.
16
Signal transmitter
17
Temperature set display
18
Economy display
19
Operating mode display
20
Sleep display
21
Transmit indicator
22
Fan speed display
23
Swing display
24
Timer mode display
25
Clock display
SPECIFICATION
SIZE (H x W x D mm)170 x 56 x 19
WEIGHT ( g )85 (w/o batteries)
ACCESSORYHolder
- (01 - 04) -
3. SPECIFICATIONS
AB A18-24L
FLOOR / CEILING TYPE
Type
Model name
Power source
Available voltage range
European energy label
Rated
Cooling
Min. - Max.
Capacity
Rated
Heating
Min. - Max.
Cooling
Input power
Heating
Cooling
Current
Heating
EER3.213.21
COP3.613.61
Moisture removal
Airflow
Fan
Sound pressure level
Heat exchanger type
Enclosure
Dimentions
( H× W ×D )
Weight
Connection pipe
Operation range
Remote controller type
Drain pipe
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
The maximum current and the maximum input value are the maximum value when operated within the operation range(temperature).
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24°CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
*The maximum current and the maximum input value are the maximum value when operated within the operation range(temperature)