General ABHA18L, ABHA18LATN, AOHA18LACL, ABHA24L, ABHA24LATN, AOHA24LACL Technical Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
R410A
1. CEILING
AB A18LATN
AB A24LATN
INDOOR UNIT
TYPE :
D2D_AB017E/03
2007.10.19
1. FEATURE
MODELS :
FLOOR / CEILING TYPE
AB A18LATN
AB A18-24L
FLOOR / CEILING TYPE
AB A18-24L
AB A24LATN
FEATURES
Energy saving rank A
European energy ranking rank A achieved by all DCization and optimization of the refrigerant cycle
Quiet operation
Air flow mode can be set in 4 steps and more detailed air flow setting is possible
18 type: 32 dB / 24 type: 36 dB at operation in the Quiet mode
Filter sign
Dirtying of filter is detected by air conditioner operating time and the user is informed
ECONOMY operation
Operation that suppresses maximum power consumption is performed
Wired/wireless simultaneous use possible
Wired remote controller and wireless remote controller can be simultaneously used.
Flexible installation
FLOOR
CEILING
Double auto swing
Combination of up/down and right/left air
direction swing allows three-dimensional air
direction control.
Since up/down air direction flaps operate
automatically, according to the operating
mode of the unit, it is possible to set the air
direction based on the operating mode.
RIGHT and LEFT
swing
UP and DOWN
swing
5 steps selectable
- (01 - 01) -
Swing
Steps
7 steps selectable
Filter sign operating time (Standard/long/short/no display)
FLOOR / CEILING TYPE
AB A18-24L
Filter sign display time interval and filter sign no display can be selected.
FLOOR / CEILING TYPE
AB A18-24L
Ceiling height (standard/high ceiling)
Air conditioner operation capacity (air flow) switching is possible as response to height of installation ceiling.
Cooling room temperature correction (Standard/low control)
Air conditioner control temperature can be switched to a little low as response to installation conditions.
Heating room temperature correction (Standard/low/slightly high/high control)
Air conditioning control temperature can be slightly adjusted as response to installation conditions.
Auto restart (ON/OFF)
ON/OFF of the function which automatically resets operation to the operation state before the power interruption at power recovery when there was a power interruption during operation can be selected.
Room temperature sensing function (ON/OFF) only at wired remote controller connection
Sensor which controls the room temperature can be selected in two types: "Indoor sensor only" or
"Indoor sensor or wired remote controller sensor can be switched by remote controller operation".
- (01 - 02) -
2. COMBINATION
2-1. OUTDOOR UNIT
FLOOR / CEILING TYPE
AB A18-24L
MODELS :
AO A18LACL
AO A24LACL
2-2. REMOTE CONTROLLER
2-2-1. WIRED REMOTE CONTROLLER
MODEL : UTB- UD
FLOOR / CEILING TYPE
AB A18-24L
2-2-2. WIRELESS REMOTE CONTROLLER
MODEL : UTB- NA
CAUTION
Remote controller is not supplied with the indoor unit.
Separate purchase is necessary.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)