Generac Power Systems Whisper-Test COMMERCIAL SERIES, Guardian Elite Whisper-Test Specification Sheet

Standby Power Rating
60 kW 60 Hz
Liquid Cooled Gas Engine Generator Sets
Whisper-Test
Low Speed Exercise
63 dB(A) at 23 feet
GENERAC 3.0L ENGINE
Naturally Aspirated
Gaseous Fueled
UL 2200 Listed
STANDARD EQUIPMENT
• All input connections in one single area
• High coolant temperature shutdown
• Low oil pressure shutdown
• Low coolant level automatic shutdown
• Overspeed automatic shutdown
• Crank timer
• Oil drain extension
• Cool flow radiator
• Closed coolant recovery system
• UV/Ozone resistant hoses
FEATURES
• Innovative design and fully prototype tested
• UL 2200 Listed
• Solid state frequency compensated voltage regulator
• Dynamic and static battery charger
• Sound attenuated acoustically designed enclosure
Whisper-Test™ for low noise level exercise
• Acoustically designed engine cooling system
• High flow low noise factory engineered exhaust system
• State of the art control system with R-Series digital control panel
Transfer Switch is sold separately
• Watertight state of the art electrical connectors
• Mainline circuit breaker
• Radiator drain extension
• Battery charge alternator
• 2 Amp static battery charger
• Battery and battery cables
• Battery rack
• Fan and belt guards
• Isochronous governor
• Flex fuel line pigtail
• Watertight electrical connectors
• Rodent proof construction
• High efficiency, low distortion Generac designed alternator
• Vibration isolated from mounting base
• Matching Generac transfer switches engineered and tested to work as a system
• All components easily accessible for maintenance
• Electrostatically applied textured powder paint
COMMERCIAL SERIES
APPLICATION & ENGINEERING DATA
GENERATOR SPECIFICATIONS
TYPE ................................................................................................................Synchronous
ROTOR INSULATION ................................................................................................Class H
STATOR INSULATION .............................................................................................. Class H
TOTAL HARMONIC DISTORTION ..................................................................................<5%
TELEPHONE INTERFERENCE FACTOR (TIF) .................................................................. <50
ALTERNATOR OUTPUT LEADS 3 PHASE ....................................................................4 wire
BEARINGS...........................................................................................................Sealed Ball
COUPLING ....................................................................................................... Flexible Disc
LOAD CAPACITY (STANDBY RATING) ....................................................................... 60 kW
EXCITATION SYSTEM .................................................................................................Direct
NOTE: Generator rating and performance in accordance with ISO8528­5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
VOLTAGE REGULATOR
TYPE .....................................................................................................................Electronic
SENSING..........................................................................................................Single Phase
REGULATION ...............................................................................................................± 1%
FEATURES.....................................................................................................V/F Adjustable
Adjustable Voltage and Gain
LED Indicators
GENERATOR FEATURES
COMMERCIAL 60 kW
ENGINE SPECIFICATIONS
MAKE ...................................................................................................................... Generac
MODEL ................................................................................................................... 3.0 Liter
CYLINDERS ....................................................................................................................V-6
DISPLACEMENT ..................................................................................................... 3.0 Liter
BORE............................................................................................................................. 3.55
STROKE .......................................................................................................................... 3.1
COMPRESSION RATIO ................................................................................................ 9.3:1
INTAKE AIR SYSTEM ..............................................................................Naturally Aspirated
VALVE SEATS ........................................................................................................ Hardened
LIFTER TYPE ...............................................................................Hydraulic - Overhead Cam
GOVERNOR SPECIFICATIONS
TYPE .....................................................................................................................Electronic
FREQUENCY REGULATION ............................................................................± Isochronous
STEADY STATE REGULATION .................................................................................± 0.25%
ADJUSTMENTS FOR:
Speed..........................................................................................................Yes
Droop..........................................................................................................Yes
ENGINE LUBRICATION SYSTEM
OIL PUMP ..................................................................................................................... Gear
OIL FILTER ..................................................................................Full flow spin-on cartridge
CRANKCASE CAPACITY ......................................................................................... 4 Quarts
Revolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120 °C above a 40 °C ambientInsulation is Class H rated at 150 °C riseAll models are fully prototyped tested
ENGINE COOLING SYSTEM
TYPE ......................................................................................................................... Closed
WATER PUMP ......................................................................................................Belt driven
FAN SPEED .................................................................................................................. 2180
FAN DIAMETER .....................................................................................................22 inches
FAN MODE .................................................................................................................. Pulle r
CONTROL PANEL FEATURES
FUEL SYSTEM
SEVEN LED INDICATOR LIGHTS  ADDITIONAL FUNCTIONS
• System ready • Utility sensing
• Low fuel pressure • Delay on utility failure for engine start
• Low battery • Engine warm-up before transfer
• Low oil pressure • Delay to retransfer to utility
• High coolant temp/low coolant temp • Engine cooldown timer
• Overspeed • Exerciser not set
• Overcrank
INTERNAL FUNCTIONS:
• 3 position switch (auto, off and manual)
• 2 wire start for any transfer switch
• Communicates with the Generac RTS transfer switch
• Built-in 7 day exerciser
• Selectable engine speed at exercise
• Governor controller is built into the master control board
• Temperature range -40 °
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
C to 70 °C
FUEL TYPE ................................................................................Natural gas, propane vapor
CARBURETOR .....................................................................................................Down Draft
SECONDARY FUEL REGULATOR ........................................................................... Standard
FUEL SHUT OFF SOLENOID .................................................................................. Standard
OPERATING FUEL PRESSURE .........................................................................5” - 14” H2O
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR .....................................................................12V 30 Amp
STATIC BATTERY CHARGER ...................................................................................... 2 Amp
RECOMMENDED BATTERY ..................................................................Group 24F, 525CCA
SYSTEM VOLTAGE.................................................................................................. 12 Volts
COMMERCIAL 60 kW
COMMERCIAL SERIES
OPERATING DATA
COMMERCIAL 60 kW KW RATING 60
ENGINE SIZE 3.0 Liter V-6
GENERATOR OUTPUT VOLTAGE/KW - 60Hz KW AMP CB Size 120/240V, single phase, 1.0 pf 60 250 300 120/208V, 3-phase, 0.8 pf 60 208.4 250 120/240V, 3-phase, 0.8 pf 60 180.6 200 277/480V, 3-phase, 0.8 pf 60 90.3 100
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208V & 240V 3-phase 120 480V 3-phase 141
ENGINE FUEL CONSUMPTION (ft Exercise cycle 123 1.34 48.7 25% of rated load 260 2.84 103.3 50% of rated load 500 5.46 198.6 75% of rated load 700 7.64 277.9 100% of rated load 960 10.48 381.3
ENGINE COOLING Air flow
(inlet air including alternator and combustion air) ft
System coolant capacity US gal. 2.5 Heat rejection to coolant BTU/hr. 270,000 Max. operating air temp. on radiator °C (°F) 60 (150) Max. ambient temperature °C (°F) 50 (140)
(Natural Gas) (Propane) Natural Gas Propane
3
/min. 3,280
3
/hr.) (gal/hr.) cu ft/hr
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 180
SOUND EMISSIONS IN DBA db(A) @ 23 feet in exercise mode 63 db(A) @ 23 feet at normal operating load 71
EXHAUST Exhaust flow at rated output 60 Hz cfm 494 Exhaust temp. at muffler outlet °F 1,050
ENGINE PARAMETERS Rated synchronous RPM 60 Hz 3600 HP at rated KW 60 Hz 94
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 °C above - °C 25
1.65% for every 10 °F above - °F 77 Altitude Deration 1% for every 100 m above - m 183 3% for every 1000 ft. above - ft. 600
RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.
INTERCONNECTIONS
COMERCIAL 60 kW
INSTALLATION LAYOUT
UNIT WEIGHT: Steel 1650 lbs., Aluminum 1513 lbs.
COMMERCIAL SERIES
GENERAC® POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI 53190
Bulletin 0174660SBY / Printed in USA 06.07, 08.07
www.guardiangenerators.com
© 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Loading...