Generac Power Systems Portable, 1658-0 Generator User Manual

Owner’s Manual
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Questions? Help is just a moment away!
Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT
Web: www.generac-portables.com or www.briggsandstratton.com
Model No. 1658-0 (5,000 Watt AC Generator) Manual No. 189633GS Revision 1 (08/23/2001)
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Last Page
Table of Contents
• Generator
• Engine oil
• Owner's manual
• Engine manual *If any parts are missing or damaged, call 1-800-270-1408.
Parts Included*
2
5,000 Watt Portable Generator
EQUIPMENT
DESCRIPTION
This generator is an engine-driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting,appliance, tool and motor loads.
This manual contains information for a generator that operates 120 and/or 240 Volt AC, single phase,60Hz devices that require up to 5,000 watts (5.0 kW) of power that pull up to 41.7 Amps at 120 Volts or 20.8 Amps at 240Volts.
CAUTION! Do Not exceed the generator’s
wattage/amperage capacity.Add up the rated watts of all devices you will connect to generator receptacles at one time.This total should not be greater than 5,000 watts for this generator. Review “Don’t Overload the Generator” on page 8.
The generator’s revolving field is driven at about 3,600 rpm by a single-cylinder engine.
Every effort has been made to ensure that information in this manual is accurate and current.However, Generac reserves the right to change, alter or otherwise improve the product and this document at any time without prior notice.
CAUTION! Do Not tamper with engine
governed speed. High operating speeds are dangerous and increase risk of personal injury or damage to equipment.The generator supplies correct rated frequency and voltage only when running at proper governed speed.Incorrect frequency and/or voltage can damage some connected electrical loads. Operating at excessively low speeds imposes a heavy load.When adequate engine power is not available engine life may be shortened.
The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.
SAFETY RULES
This generator set was designed and manufactured for specific applications. Do Not attempt to modify the unit or use it for any application it was not designed for. If you have any questions about your generator’s application, ask your dealer or consult the factory.
The manufacturer could not possibly anticipate every circumstance that might involve a hazard. For that reason warnings in the manual and warnings on tags or decals affixed to the unit are not all–inclusive. If you intend to handle, operate or service the unit by a procedure or method not specifically recommended by the manufacturer, first make sure that such a procedure or method will not render this equipment unsafe or pose a threat to you and others.
Read this manual carefully and become familiar with your generator set. Know its applications, its limitations and any hazards involved.
WARNING! You must isolate the generator
from the electric utility using approved transfer equipment if this unit is used for backup power.
Failure to isolate the generator from the power utility may result in injury or death to electric utility workers and damage to the generator due to a backfeed of electrical energy.
Whenever unit is providing backup power, the electric utility must be notified.
DANGER! Generator exhaust gases contain DEADLY carbon monoxide gas. If breathed in sufficient concentrations, carbon monoxide can cause unconsciousness or death. Operate
this equipment outdoors where adequate ventilation is available.
The engine exhaust from this product contains
chemicals known to the State of California
to cause cancer, birth defects,
or other reproductive harm.
WARNING:
5,000 Watt Portable Generator
3
• The generator produces a very powerful voltage that can
cause serious injury or death by electrocution. Never touch bare wires or receptacles. Never permit a child or any unqualified person to operate the generator.
Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet are wet. Death or serious injury from electrocution may result.
• Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area (such as metal decking or steel work).
Never use worn, bare, frayed or otherwise damaged electrical cords with the generator. Death, serious injury and property damage from electrical shock may result.
Gasoline is highly FLAMMABLE and its vapors are
EXPLOSIVE. Never allow smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. Comply
with all laws regulating storage and handling of gasoline.
Do Not overfill the fuel tank.Always allow room for fuel expansion. If tank is overfilled, fuel can overflow
onto a hot engine and cause a FIRE or an EXPLOSION.
Never store a generator with fuel in the tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater, clothes dryer). FIRE or an EXPLOSION may result.
• The unit requires an adequate flow of cooling air for its continued proper operation. Never operate the unit inside any room or enclosure where the free flow of cooling air into and out of the unit might be obstructed. Allow at least 2 feet of clearance on all sides of generator, even while operating unit outdoors, or you could damage the unit.
Never start, or stop the unit with electrical loads connected to receptacles with the connected devices turned ON. Start the engine and let it stabilize before connecting any electrical loads. Disconnect all electrical loads before shutting down the generator.
Do Not insert any object through cooling slots of the engine.You could damage the unit or injure yourself.
Never operate the generator:
in rain; in any enclosed compartment; when connected electrical devices overheat; if electrical output is lost; if engine or generator sparks; if flame or smoke is observed while unit is running; if unit vibrates excessively.
GROUNDING THE
GENERATOR
The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 1).
Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.
Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
Figure 1 — Grounding Wing Nut
Grounding Wing Nut
4
5,000 Watt Portable Generator
Your generator is ready for use after it has been properly serviced with the recommended oil and fuel.
If you have any problems with the generator, please call the generator helpline at 1-800-270-1408.
IMPORTANT: Any attempt to run the unit before it has
been serviced with the recommended oil will result in an engine failure.
REMOVE GENERATOR
FROM CARTON
• Set the carton on a rigid flat surface with “This Side Up” arrows pointing upward.
• Carefully open the top flaps of the shipping carton.
• Cut down corners at one end of carton from top to bottom and lay that side of carton down flat.
• Remove all packing material, carton fillers, etc.
• Remove the generator from the shipping carton.
CARTON CONTENTS
Check all contents. If any parts are missing or damaged, call the generator helpline at 1-800-270-1408.
• The generator
• Generator and engine owner’s manuals
• Engine oil
BEFORE STARTING THE
ENGINE
Add Oil
CAUTION! Any attempt to crank or start the engine
before it has been properly filled with the recommended oil may result in an engine failure.
To fill your engine with oil:
• Place generator on a level surface.
• Follow the oil grade recommendations and oil fill instructions given in the engine owner’s manual.
NOTE:The generator’s revolving field rides on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.
Add Gasoline
WARNING! Never fill fuel tank indoors. Never
fill fuel tank when engine is running or hot.Allow unit to cool for two minutes before refueling. Do Not light a cigarette or smoke when filling the fuel tank.
WARNING! Do Not overfill the fuel tank.
Always allow room for fuel expansion.
• Use regular UNLEADED gasoline with the generator engine. Do Not use premium gasoline. Do Not mix oil with gasoline.
• Clean area around fuel fill cap, remove cap.
• Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill.Allow about 1.5" of tank space for fuel expansion (Figure 2).
• Install fuel cap and wipe up any spilled gasoline.
IMPORTANT: It is important to prevent gum deposits from forming in essential fuel system parts, such as the carburetor, fuel filter, fuel hose or tank during storage.Also, experience indicates that alcohol–blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic fuel can damage the fuel system of an engine while in storage.
To avoid engine problems,the fuel system should be emptied before storage of 30 days or longer. See “Storage” on page 9. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.
Figure 2 — Typical Fuel Expansion Space
Fuel
Tank
1.5” Air Space
5,000 Watt Portable Generator
5
120 Volt AC, 20 Amp, Duplex Receptacle — May be
used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 20 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
Air Cleaner — Uses a dry type filter element and foam pre–cleaner to limit the amount of dirt and dust sucked into the engine.
Choke Lever — Used when starting a cold engine. Circuit Breakers (AC) — Each receptacle is provided
with a "push to reset" circuit breaker to protect the generator against electrical overload.
Fuel Tank — Capacity of five (5) U.S. gallons. Grounding Wing Nut — Used for proper grounding of
unit.
Oil Fill Cap — Add oil to engine here. Recoil starter — Used to start the engine. Rocker Switch — Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch off engine.
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp Duplex Receptacle
Fuel Tank
Choke Lever
Recoil Starter
Rocker Switch
Circuit Breakers (AC)
120/240 Volt AC, 20 Amp Receptacle
Air Cleaner
Grounding Wing Nut (not shown)
Oil Fill Cap (not shown)