Generac Power Systems GP Series, 005625-0, 005626-0, 005680-0, 005681-0 Owner's Manual

Page 1
Owner’s Manual
• SAFETY
• ASSEMBLY
• OPERATION
GP Series
Portable Generator
• TROUBLESHOOTING
• WARRANTY
AUTHORIZED DEALER SUPPORT:
www.generac.com
or
1-888-436-3722
COMMERCIAL • INDUSTRIAL • RESIDENTIAL
MODELS: 005625-0, 005626-0
005680-0, 005681-0
Page 2
Table of Contents
Portable Generator System
Introduction ................................................................... 1
Read this Manual Thoroughly ..................................... 1
Safety Rules .................................................................. 2
Standards Index.................................................................... 3
Section 1 – General Information ................................. 4
1.1 Unpacking ............................................................................. 4
1.1.1 Accessory Box ........................................................ 4
1.2 Assembly .............................................................................. 4
1.2.1 Assembling the Accessory Kit ................................ 4
1.2.2 Starter Connection (Electric Start Only) ................. 4
Section 2 – Operation .................................................. 5
2.1 Know the Generator ............................................................. 5
2.2 Hourmeter ............................................................................. 6
2.3 Cord Sets and Connection Plugs ......................................... 6
2.3.1 120 VAC, 20 Amp, Duplex Receptacle.................... 6
2.3.2 120/240 VAC, 30 Amp, Receptacle ......................... 6
2.4 How to Use the Generator .................................................... 6
2.4.1 Grounding the Generator ........................................ 6
2.4.2 Connecting Electrical Loads ................................... 7
2.5 Don’t Overload the Generator .............................................. 7
2.6 Wattage Reference Guide .................................................... 7
2.7 Before Starting the Generator .............................................. 8
2.7.1 Adding Engine Oil ................................................... 8
2.7.2 Adding Gasoline ...................................................... 8
2.8 Starting Pull Start Engines ................................................... 8
2.9 Starting Electric Start Engines ............................................. 9
2.10 Stopping the Engine ........................................................... 10
2.11 Low Oil Level Shutdown System ........................................ 10
2.10.1 Sensing Low Oil Level .......................................... 10
2.12 Charging a Battery (Electric Start Units Only) ................... 10
Section 3 – Maintenance ........................................... 10
3.1 Maintenance Schedule ....................................................... 10
3.2 Product Specifications ........................................................ 10
3.2.1 Generator Specifications ....................................... 10
3.2.2 Engine Specifications ............................................ 11
3.3 General Recommendations ................................................ 11
3.3.1 Generator Maintenance ........................................ 11
3.3.2 To Clean the Generator ........................................ 11
3.3.3 Engine Maintenance ............................................. 11
3.3.4 Checking Oil Level ................................................ 11
3.3.5 Changing the Oil ................................................... 11
3.3.6 Replacing the Spark Plug .................................... .12
3.3.7 Replacing the Battery ........................................... 12
3.4 Service Air Cleaner ............................................................ 12
3.5 Clean Spark Arrestor Screen ............................................. 13
3.6 Adjusting Valve Clearance .................................................. 13
3.7 Long Term Storage ............................................................. 14
3.8 Other Storage Tips ............................................................. 14
Section 4 – Troubleshooting ...................................... 15
4.1 Troubleshooting Guide ........................................................ 15
Section 5 – Notes ....................................................... 16
Section 6 – Warranty .................................. Back Cover
Page 3
INTRODUCTION
Thank you for purchasing this model of the GP Series portable generator by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads on job sites, or remote locations where no utility power is available or in place of utility power due to a power outage.
READ THIS MANUAL THOROUGHLY
If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.
Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:
DANGER
Using a generator indoors WILL KILL YOU IN
MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
NEVER use in the home, or in partly enclosed
areas such as garages. ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust gas.
DANGER
Using a generator indoors WILL KILL YOU IN MINUTES. Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
DANGER
After this heading, read instructions that, if
not strictly complied with, will result in serious personal injury, including death and/or property damage.
After this heading, read instructions that, if not
strictly complied with, may result in serious personal injury and/or property damage.
After this heading, read instructions that, if not
strictly complied with, could result in damage to equipment and/or property.
NOTE:
After this heading, read explanatory statements that require
special emphasis.
These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents.
Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates is as follows:
This symbol points out important safety
information that, if not followed, could endanger personal safety and/or property of others.
This symbol points out potential explosion
hazard.
This symbol points out potential fire hazard.
This symbol points out potential electrical shock
hazard.
The operator is responsible for proper and safe use of the equipment. We strongly recommend that the operator read this manual and thoroughly understand all instructions before using the equipment.
We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.
NEVER use in the home or in partly enclosed areas such as garages. ONLY use outdoors and far from open windows, doors and vents.
Always disconnect the spark plug wire and
place the wire where they cannot contact the spark plug to prevent accidental starting when setting up, transporting, adjusting or making repairs to the generator.
The generator produces dangerously high voltage that can cause
extremely hazardous electrical shock. Avoid contact with bare wires, terminals, etc. Never permit any unqualified person to operate or service the generator.
Never handle any kind of electrical cord or device while standing
in water, while barefoot or while hands or feet are wet. Dangerous electrical shock will result.
The National Electric Code requires the frame and external
electrically conductive parts of the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the generator. Consult with a local electrician for grounding requirements in the area.
Do not use worn, bare, frayed or otherwise damaged electrical
cord sets with the generator.
Operate generator only on level surfaces and where it will not be
exposed to excessive moisture, dirt, dust or corrosive vapors.
Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE.
Do not permit smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. Comply with all laws regulating storage and handling of gasoline.
Never add fuel while unit is running. Allow unit
to cool entirely before adding fuel.
Do not overfill the fuel tank. Always allow room
for fuel expansion. If tank is over-filled, fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION.
Never store generator with fuel in tank where gasoline vapors
might reach an open flame, spark or pilot light (as on a furnace, water heater or clothes dryer). FIRE or EXPLOSION may result.
Generator exhaust gases contain DEADLY carbon monoxide gas.
This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Operate this equipment only in the open air where adequate ventilation is available.
1
Page 4
IMPORTANT SAFETY INSTRUCTIONS
Portable Generator System
SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's
installation site. Safety should be stressed to all operators and potential operators of this equipment.
DANGER
NEVER operate the generator indoors, in a garage, near an
open window, or in an area that could accumulate exhaust gas.
Allow at least five (5) feet, or greater, of clearance on all
sides of generator. Never operate the unit inside any room or enclosure.
Never start or stop the unit with electrical loads connected to
receptacles AND with connected devices turned ON. Start the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator.
Do not insert objects through unit's cooling slots.
Never operate generator: in rain; indoors or in any enclosed
compartment; if connected electrical devices overheat; if electrical output is lost; if engine or generator sparks; if flames or smoke are observed while unit is running; if unit vibrates excessively.
Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this manual and with the unit. The generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.
The engine exhaust from this product contains
chemicals known to the state of California to cause
cancer, birth defects or other reproductive harm.
This product contains or emits chemicals known to the state of California to cause
cancer, birth defects or other reproductive harm.
The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the generator unsafe.
2
WARNING:
WARNING:
DANGER
Despite the safe design of this generator,
operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment.
Potentially lethal voltages are generated by
these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.
Parts of the generator are rotating and/or hot
during operation. Exercise care near running generators. Do not touch hot surfaces such as the muffler. Severe burns can occur on contact. Allow generator to cool before touching.
GENERAL HAZARDS
Never operate in an enclosed area or indoors.
For safety reasons, the manufacturer recommends that the
maintenance of this equipment is carried out by an Authorized Dealer.
The engine exhaust fumes contain carbon monoxide, which
can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. This exhaust system must be properly maintained. Do nothing that might render the exhaust system unsafe or in noncompliance with any local codes and/or standards.
Keep hands, feet, clothing, etc., away from drive belts, fans, and
other moving or hot parts. Never remove any fan guard while the unit is operating.
Adequate, unobstructed flow of cooling and ventilating air is critical
to correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. The generator MUST be operated outdoors.
When working on this equipment, remain alert at all times. Never
work on the equipment when physically or mentally fatigued.
Inspect the generator regularly, and contact the nearest Authorized
Dealer for parts needing repair or replacement.
Before performing any maintenance on the generator, disconnect
its battery cables (if equipped) to prevent accidental start up. Disconnect the cable from the battery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last.
Never use the generator or any of its parts as a step. Stepping on
the unit can stress and break parts, and may result in dangerous operating conditions from leaking exhaust gases, fuel leakage, oil leakage, etc.
Do NOT operate generator in the rain.
Page 5
IMPORTANT SAFETY INSTRUCTIONS
Portable Generator System
ELECTRICAL HAZARDS
All generators covered by this manual produce dangerous electrical • voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.
Do not handle any kind of electrical device while standing in water, • while barefoot, or while hands or feet are wet. DANGEROUS
ELECTRICAL SHOCK MAY RESULT.
The National Electrical Code (NEC) requires the frame and external • electrically conductive parts of the generator to be connected to an approved earth ground. Local electrical codes also may require proper grounding of the generator electrical system.
In case of accident caused by electric shock, immediately shut • down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a non-conducting implement, such as a rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help.
Never wear jewelry when working on this equipment. Jewelry can • conduct electricity resulting in electric shock, or may get caught in moving components causing injury.
EXPLOSION HAZARDS
Do not smoke around the generator. Wipe up any fuel or oil spills
immediately. Ensure that no combustible materials are left on or near the generator, as FIRE or EXPLOSION may result. Keep the area surrounding the generator clean and free from debris.
Gasoline vapors are extremely FLAMMABLE and EXPLOSIVE.
STANDARDS INDEX
In the absence of pertinent standards, codes, regulations and laws, the published information listed below may be used as a guideline for operation of this equipment. Always reference the latest revision available for the standards listed.
1. NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC CODE.
2. Article X, NATIONAL BUILDING CODE, available from the American Insurance Association, 85 John Street, New York, N.Y.
10038.
3. AGRICULTURAL WIRING HANDBOOK, available from the Food and Energy Council, 909 University Avenue, Columbia, MO
65201.
4. ASAE EP-3634, INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS, available from the American Society of Agricultural Engineers, 2950 Niles Road, St. Joseph, MI 49085.
5. NFPA No. 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE.
FIRE HAZARDS
For fire safety, the generator must be operated and maintained • properly. Operation must always comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is operated in accordance with the manufacturer’s instructions and recommendations. Do not alter the construction of the generator or change controls which might create an unsafe operating condition.
Keep a fire extinguisher near the generator at all times. Extinguishers • rated “ABC” by the National Fire Protection Association are appropriate for use on the portable generator electric system. Keep the extinguisher properly charged and be familiar with its use. If there are any questions pertaining to fire extinguishers, consult the local fire department.
Avoid spilling gasoline on a hot engine. NEVER add fuel while the • unit is running. DO NOT overfill the fuel tank. Always allow room for fuel expansion.
3
Page 6
Section 1 – General Information
Portable Generator System
1.1 UNPACKING
Remove all packaging material.
Remove separate accessory box.
Remove the generator from carton.
1.1.1 ACCESSORY BOX
Check all contents. If any parts are missing or damaged locate an authorized dealer at 1-888-436-3722.
Contents Include:
1 – Owner’s Manual • 1 - Left Handle Assembly
1 - Quart Oil SAE 30 • 1 - Right Handle Assembly
2 - Never-Flat Wheels • 1 - Frame Foot
1 - 12 volt Adapter Plug Charger* • 1 - Foot Support
1 - Hardware Bag (containing the following):
2 - Rubber Feet 2 - 5/16” Bolts
2 - 5/16” Flat Washers 4 - 5/16” Locking Flange Nuts
4 - 5/16” Carriage Bolts 2 - 5/16” Locking Cap Nuts
2 - 1/2” Axle Bolts 2 - 1/2” Locking Flange Nuts
2 - 1/2" Flat Washers
* Electric start units only.
1.2 ASSEMBLY
The generator requires some assembly prior to using it. If problems arise when assembling the generator, please call the Generator Helpline at 1-888-436-3722.
Figure 1 – Wheel Assembly
FOOT
FOOT SUPPORT
Figure 2 – Install Handle Kit
1.2.1 ASSEMBLING THE ACCESSORY KIT
The wheels are designed into the unit to greatly improve the portability of the generator.
NOTE:
The wheels are not intended for over-the-road use.
1. Refer to Figure 1 and install Wheels as follows:
• Slide the 1/2” Axle Bolt through the 1/2" Washer, the Wheel and Wheel bracket on frame.
• Install 1/2” Locking Flange Nuts onto 1/2” Flange Bolt.
2. Refer to Figure 1 and install Frame Foot, Foot Support and Rubber
Feet as shown.
• Slide Rubber Foot stud through the Foot Support and Frame Foot; Install 5/16” Locking Flange Nuts Slide 5/16” Bolt through 5/16” Flat Washer and then through holes in Frame Rail.
• Slide Frame Foot onto 5/16” Bolts; Install 5/16” Locking Flange Nuts.
3. Refer to Figure 2 and install Handles as shown.
• Remove top Curved Head Bolts and Cap Nuts (Cap Nuts will be re-used).
• Slide Handle Assembly over Frame Tube, aligning 2 holes.
• Slide 5/16” Carriage Bolts through; Install 5/16” Cap Nuts.
1.2.2 STARTER CONNECTION (ELECTRIC START ONLY)
The unit has been deliberately shipped with the starter cable disconnected.
To connect starter:
1. Locate starter cable (a hang tag is attached as shown in Figure
3).
2. Pull vinyl boot back onto starter cable.
3. Remove nut and washer from starter post.
4. Put starter cable onto post and re-install washer and nut.
4
Page 7
Section 2 – Operation
Portable Generator System
Figure 3 – Starter Connection
2.1 KNOW THE GENERATOR
Read the Owner’s Manual and Safety Rules before operating this generator.
Compare the generator to Figures 4 through 6 to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.
1. 120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical
power for the operation of 120 Volt AC, 20 Amp, single-phase, 60 Hz electrical lighting, appliance, tool and motor loads.
2. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies
electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single-phase, 60 Hz, electrical lighting, appliance, tool and motor loads.
3. Circuit Breakers (AC) – Each receptacle is provided with a
push-to-reset circuit breaker to protect the generator against electrical overload.
11. Handles – Pivot and retract for storage. Press the spring-loaded button to move handles.
12. Gas Cap – Fuel fill location.
13. Fuel Gauge – Shows fuel level in tank.
14. Oil Fill – Add oil here.
15. Recoil Starter – Use to star t engine manually.
16. Fuel Shut Off – Valve between fuel tank and carburetor.
17. Oil Drain – Use to drain engine oil.
18*. Battery Charger Input – This receptacle allows the capability to
recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box. Located behind the battery charger input is a 1.50 Amp in-line fuse which is inside the control panel to protect the battery.
19*. Battery – Powers the electric starter.
* Electric start only.
Figure 5 - Generator Controls
Figure 4 - Control Panel
4. Hourmeter – Tracks hours of operation.
5. Air Filter – Filters intake air as it is drawn into the engine.
6. Choke Knob – Used when starting a cold engine.
7. Fuel Tank – Tank holds 6.6 U.S. gallons of fuel.
8. Grounding Lug – Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
9. Run/Stop Switch – Controls the operation of the generator.
10. Muffler – Quiets the engine.
Figure 6 - Generator Controls
5
Page 8
Section 2 – Operation
Portable Generator System
2.2 HOURMETER
The Hourmeter tracks hours of operation for scheduled maintenance:
There will be a "CHG OIL" message every 100 hours. The message will flash one hour before and one hour after each 100 hour interval, again providing a two hour window to perform service.
This message will actually begin flashing at 99 hours and disable itself at 101 hours providing a two hour window to perform the service.
Every 200 hours the "SVC" icon on the lower left hand corner of the display will flash. The message will flash one hour before and one hour after each 200 hour interval providing a two hour window to perform service.
When the hour meter is in the Flash Alert mode, the maintenance message will always alternate with elapsed time in hours and tenths. The hours will flash four times, then alternate with the maintenance message four times until the meter resets itself.
100 hours - CHG OIL — Oil Change Interval (Every 100 hrs)
200 hours - SVC — Air Filter Interval (Every 200 hrs)
2.3 CORD SETS AND CONNECTION PLUGS
2.3.1 120 VAC, 20 AMP, DUPLEX RECEPTACLE
This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 7). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).
Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.
Figure 7 - 120 Volt AC, 20 Amp, Duplex Receptacle
Figure 8 - 120/240 VAC, 30 Amp Receptacle
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts (7.2 kW) of power at 30 Amps. The outlet is protected by two 30 Amp push-to­reset circuit breakers.
2.4 HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the generator helpline at 1-888-436-3722.
2.4.1 GROUNDING THE GENERATOR
The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground (Figure 9). Local electrical
codes may also require proper grounding of the unit. For that purpose, connecting a No. 10 AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with
a local electrician for grounding requirements in the area.
2.3.2 120/240 VAC, 30 AMP RECEPTACLE
Use a NEMA L14-30 plug with this receptacle (rotate to lock/unlock). Connect a suitable 4-wire grounded cord set to the plug and to the desired load. The cord set should be rated for 250 Volts AC at 30 Amps (or greater) (Figure 8).
6
Figure 9 - Grounding the Generator
Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in
connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.
Page 9
Section 2 – Operation
Portable Generator System
2.4.2 CONNECTING ELECTRICAL LOADS
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect 3-phase loads to the generator. DO NOT connect 50 Hz loads to the generator.
Let engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 Volt AC, single phase,
60 Hz electrical loads.
Add up the rated watts (or amps) of all loads to be connected
at one time. This total should not be greater than (a) the rated wattage/amperage capacity of the generator or (b) circuit breaker rating of the receptacle supplying the power. See "Don't Overload the Generator".
2.5 DON’T OVERLOAD THE GENERATOR
Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:
Add up the total wattage of all electrical devices to be connected
at one time. This total should NOT be greater than the generator's wattage capacity.
The rated wattage of lights can be taken from light bulbs. The rated
wattage of tools, appliances and motors can usually be found on a data label or decal affixed to the device.
If the appliance, tool or motor does not give wattage, multiply volts
times ampere rating to determine watts (volts x amps = watts).
Some electric motors, such as induction types, require about three
times more watts of power for starting than for running. This surge of power lasts only a few seconds when starting such motors. Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator:
1. Figure the watts needed to start the largest motor.
2. Add to that figure the running watts of all other connected loads.
The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time.
NOTE: All figures are approximate. See data label on appliance for wattage requirements.
2.6 WATTAGE REFERENCE GUIDE
Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Running Watts
*Air Conditioner (12,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1700
*Air Conditioner (24,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3800
*Air Conditioner (40,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000
Battery Charger (20 Amp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Belt Sander (3") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000
Chain Saw. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Circular Saw (6-1/2"). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1000
*Clothes Dryer (Electric) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5750
*Clothes Dryer (Gas). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Clothes Washer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1150
Coffee Maker. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1750
*Compressor (1 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Compressor (3/4 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
*Compressor (1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1400
Curling Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
*Dehumidifier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650
Disc Sander (9") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Edge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Electric Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
Electric Nail Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Electric Range (per element) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
Electric Skillet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1250
*Freezer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..700
*Furnace Fan (3/5 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 875
*Garage Door Opener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 to 750
Hair Dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Hand Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 to 1100
Hedge Trimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Impact Wrench . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
Iron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
*Jet Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800
Lawn Mower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1200
Light Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Microwave Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 to 1000
*Milk Cooler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100
Oil Burner on Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
Oil Fired Space Heater (140,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . 400
Oil Fired Space Heater (85,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . 225
Oil Fired Space Heater (30,000 Btu) . . . . . . . . . . . . . . . . . . . . . . . . . 150
*Paint Sprayer, Airless (1/3 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600
Paint Sprayer, Airless (handheld) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Radio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 to 200
*Refrigerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
Slow Cooker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
*Submersible Pump (1-1/2 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2800
*Submersible Pump (1 HP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
*Submersible Pump (1/2 HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
*Sump Pump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .800 to 1050
*Table Saw (10") . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1750 to 2000
Television . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 to 500
Toaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 to 1650
Weed Trimmer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
* Allow 3 times the listed watts for starting these devices.
7
Page 10
10W-30
SAE 30
Synthetic 5W-30
Section 2 – Operation
Portable Generator System
2.7 BEFORE STARTING THE GENERATOR
Prior to operating the generator, engine oil and gasoline will need to be added, as follows:
2.7.1 ADDING ENGINE OIL
All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil's viscosity grade according to the expected operating temperature (also see chart).
Above 40° F, use SAE 30
Below 40° F and down to 10° F, use 10W-30
Below 10° F, use synthetic 5W-30
SAE 30
10W-30
Do not overfill the fuel tank. Always leave room
for fuel expansion. If the fuel tank is over-filled, fuel can over flow onto hot engine and cause an explosion.
Use regular UNLEADED gasoline with the generator engine. Do
not use premium gasoline. Do not mix oil with gasoline.
Clean area around fuel fill cap, remove cap.
Slowly add unleaded regular gasoline to fuel tank. Fill to bottom of
screen filter. Be careful not to overfill (Figure 10).
Install fuel cap and wipe up any spilled gasoline.
Figure 10 - Fuel Tank
Fuel Tank
Synthetic 5W-30
Any attempt to crank or start the engine before
it has been properly serviced with the recommended oil may result in an engine failure.
Place generator on a level surface.
Clean area around oil fill and remove oil fill cap and dipstick.
Wipe dipstick clean.
Slowly fill engine with oil through the oil fill opening until it reaches
the full mark. Stop filling occasionally to check oil level. Be
careful not to over fill.
Install oil fill cap and finger tighten securely.
Check engine oil level before starting each time thereafter.
2.7.2 ADDING GASOLINE
DANGER
Never fill fuel tank indoors. Avoid spilling
gasoline on hot engine. Allow engine to cool entirely before adding fuel. Never fill fuel tank when engine is running or hot. DO NOT light a cigarette or smoke when filling the fuel tank. Gasoline is highly flammable and its vapors are explosive.
8
Fuel
IMPORTANT: It is important to prevent gum deposits from forming
in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage. To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See the "Storage" section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.
DO NOT Fill Above Lip
2.8 STARTING PULL START ENGINES
Never start or stop engine with electrical
devices plugged into the receptacles AND devices turned on.
Unplug all electrical loads from the unit's receptacles before
starting the engine.
Make sure the unit is in a level position.
OPEN the Fuel Shut-off Valve (Figures 11 and 13).
Turn engine RUN/STOP switch to ON position (Figure 12).
Pull engine CHOKE knob outward to • FULL CHOKE position
(Figure 12).
To start engine, firmly grasp the recoil handle and pull slowly until
increased resistance is felt. Pull rapidly up and away.
When engine starts, move choke knob to 1/2-CHOKE position until
engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2-CHOKE position until engine runs smoothly and then to RUN position.
Page 11
Section 2 – Operation
Portable Generator System
Figure 11 - Fuel Shut-off Valve
NOTE:
If engine fires, but does not continue to run, move choke lever to FULL CHOKE and repeat starting instructions.
Figure 12 - Choke Position
Choke
Figure 13 - Fuel Shut-off Valve
To start engine, press and hold the Start/Run/Stop switch in the
“Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.
When the engine starts, move choke knob to “1/2 Choke” position
until the engine runs smoothly and then fully in to the “Run” position. If engine falters, move choke knob back out to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.
This generator is also equipped with a manual recoil starter which
may be used if the battery is discharged.
NOTE:
The switch must be in the RUN position.
To start manually, firmly grasp the recoil handle and pull slowly
until increased resistance is felt. Pull rapidly up and away to start engine. Then follow the same choke sequence.
IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” carefully.
2.9 STARTING ELECTRIC START ENGINES
Never start or stop engine with electrical
devices plugged into the receptacles AND devices turned on.
Unplug all electrical loads from the unit's receptacles before
starting the engine.
Make sure the unit is in a level position.
Open the fuel shut-off valve (Figures 11 and 13).
Move engine CHOKE knob outward to “Full Choke” position
(Figure 14).
Figure 14 - Choke Position
Choke
Start/Run/Stop Switch
NOTE:
If engine fires, but does not continue to run, move choke lever to “Full Choke” and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” carefully.
9
Page 12
Section 3 — Maintenance
Portable Generator System
2.10 STOPPING THE ENGINE
Shut off all loads, then unplug the electrical loads from generator
panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on.
Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
Move Run/Stop switch to • OFF position.
Close fuel valve.
2.11 LOW OIL LEVEL SHUTDOWN SYSTEM
The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.
2.11.1 SENSING LOW OIL LEVEL
If the system senses a low oil level during operation, the engine shuts down. The engine will not run until the oil has been refilled to the proper level.
2.12 CHARGING A BATTERY (ELECTRIC START
UNITS ONLY)
DANGER
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious injury.
DANGER
Figure 15 - Battery Charger Jack
BATTERY
CHARGER
INPUT
NOTE:
Do not use the battery charger for more than 48 hours at one charge.
3.1 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.
Check Oil Level At Each Use Change Oil ‡ *Every 100 hours or Every Season Check Valve Clearance ***Every Season Service Air Filter ** Every 200 hours or Every Season Replace Spark Plug Every Season
‡ Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dir ty or dusty operating conditions. Replace air filter parts
if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of operation and
every 100 hours thereafter.
Do not permit smoking, open flame, sparks or
any other source of heat around a battery. Wear protective goggles, rubber apron and rubber gloves when working around a battery. Battery electrolyte fluid is an extremely corrosive sulfuric acid solution that can cause severe burns. If spill occurs flush area with clear water immediately.
Use battery charger plug to keep the battery charged and ready for use. Battery charging should be done in a dry location.
1. Plug charger into “Battery Charger Input” jack, located on the
control panel. Plug wall receptacle end of the battery charger into a 120 Volt AC wall outlet (Figure 15).
2. Unplug battery charger from wall outlet and control panel jack
when generator is going to be in use.
10
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
Rated. Power .............................................................................. 7.0/8.0 kW**
Surge Power ................................................................................ 8.7/12.0 kW
Rated AC Voltage .............................................................................. 120/240
Rated Max AC Load
Current @ 240V (7.0/8.0 kW) ...................................... 25 Amps/30 Amps**
Current @ 120V .......................................................................... 20 Amps**
Rated Frequency ............................................................ 60 Hz @ 3600 RPM
Phase ........................................................................................ Single Phase
** Maximum wattage and current are subject to, and limited by, such factors as fuel
Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.
Page 13
Section 3 — Maintenance
Portable Generator System
3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM ............................................................ 14.5
Displacement .........................................................................................410cc
Spark Plug Type ........................................Champion RC14YC or Equivalent
Spark Plug Gap ........................................................ 0.030 inch or (0.76 mm)
Gasoline Capacity .................................................................... 8 U.S. gallons
Oil Type ......................................... See Chart in "Adding Engine Oil" Section
Oil Capacity ......................................................... w/ Filter Change = 1.5 Qts.
w/o Filter Change = 1.2 Qts.
Run Time/Fuel Consumption-1/2 Load ........ 10 Hours / .80 gallons per hour
Class II Emission Certified
3.3 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
Some adjustments will need to be made periodically to properly maintain the generator.
All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the "Maintenance Schedule".
NOTE: Once a year replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.
3.3.2 TO CLEAN THE GENERATOR
Use a damp cloth to wipe exterior surfaces clean.
A soft, bristle brush may be used to loosen caked on dirt, oil, etc.
A vacuum cleaner may be used to pick up loose dirt and debris.
Low pressure air (not to exceed 25 psi) may be used to blow away
dirt. Inspect cooling air slots and openings on the generator. These openings must be kept clean and unobstructed.
3.3.3 ENGINE MAINTENANCE
DANGER
When working on the generator, always
disconnect negative cable from battery. Also disconnect spark plug wires from spark plug and keep wire away from spark plug.
3.3.4 CHECKING OIL LEVEL
See the “Before Starting the Generator” section for information on checking the oil level. The oil level should be checked before each use, or at least every eight hours of operation. Keep the oil level maintained.
3.3.5 CHANGING THE OIL
Change the oil every 100 hours. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.
3.3.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.
Never insert any object or tool through the air
cooling slots, even if the engine is not running.
NOTE: DO NOT use a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generator through cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Hot oil may cause burns. Allow engine to cool
before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.
NOTE:
Whenever possible, run engine for approximately five (5) minutes to get the engine oil hot. This will aid in draining the oil.
Use the following instructions to change the oil while the engine is still warm:
Clean area around oil drain plug.
Remove oil drain plug from engine and oil fill plug to drain oil
completely into a suitable container.
When oil has completely drained, install oil drain plug and tighten
securely.
Fill oil sump with recommended oil. (See “Before Starting the
Generator” for oil recommendations).
Wipe up any spilled oil.
Dispose of used oil at a proper collection center.
11
Page 14
Section 3 — Maintenance
Portable Generator System
3.3.6 REPLACING THE SPARK PLUG
Use Champion RC14YC spark plug or equivalent. Replace the plug once each year. This will help the engine start easier and run better.
1. Stop the engine and pull the spark plug wire off of the spark
plug.
2. Clean the area around the spark plug and remove it from the
cylinder head.
3. Set the spark plug's gap to 0.70-0.80 mm (0.028-0.031 in.).
Install the correctly gapped spark plug into the cylinder head (Figure 16).
Figure 16 - Spark Plug Gap
3.3.7 REPLACING THE BATTERY
The battery shipped with the generator has been provided fully charged. Caution must be taken when connecting the battery (Figure
17).
NOTE:
A battery may lose some of it’s charge when not in use for prolonged periods of time.
The NEGATIVE battery terminal should:
1. Always be DISCONNECTED FIRST.
2. Always be CONNECTED LAST.
Figure 17 - Battery Connections
(BLACK)
NEGATIVE BATTERY
CABLE (BLACK)
NUT
LOCK WASHER
3.4 SERVICE AIR CLEANER
The engine will not run properly and may be damaged if using a dirty air cleaner. Clean or replace the air cleaner paper filter once a year (Figure 18). Clean or replace more often if operating under dusty conditions. Clean foam pre-cleaner every month or more often under dusty conditions.
Figure 18 - Air Cleaner
BASE
PRE-CLEANER
FILTER
COVER
To clean or replace foam pre-cleaner:
Remove air cleaner cover, then foam pre-filter.
Wash pre-cleaner in soapy water. Squeeze pre-filter dry in clean
cloth (DO NOT TWIST).
Clean air cleaner cover before re-installing it.
To clean or replace paper air filter:
Remove air cleaner cover; then remove foam pre-filter (service if
necessary) and remove paper filter.
Clean paper filter by tapping it gently on a solid surface. If the
filter is too dirty, replace it with a new one. Dispose of the old filter properly.
Clean air cleaner cover then slip pre-cleaner over filter. Next insert
new paper filter into the base of the air cleaner. Re-install air cleaner cover.
NOTE:
To order a new air filter, please contact the nearest authorized service center at 1-800-333-1322.
POSITIVE BATTERY
CABLE (RED)
SCREW
12
FLAT WASHER
CABLE BOOT
Page 15
Section 3 — Maintenance
Portable Generator System
3.5 CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen at least once each year (Figure 19). If unit is used regularly, inspect and clean more often.
NOTE:
If using the generator on any forest-covered, brush-covered or grass-covered unimproved land, it must equipped with a spark arrestor. The spark arrestor must be maintained in good condition by the owner/operator.
Clean and inspect the spark arrestor as follows:
Remove muffler heat shield from muffler, removing four screws.
Remove spark arrestor from muffler, removing four screws.
Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USE a defective screen. If screen is not damaged, clean it with commercial solvent.
Replace the spark arrestor and muffler heat shield.
Figure 19 - Spark Arrestor
Make sure the piston is at Top Dead Center (TDC) of its
compression stroke (both valves closed). To get the piston at TDC, remove the intake screen at the front of the engine to gain access to the flywheel nut. Use a large socket and socket wrench to rotate the nut and hence the engine in a clockwise direction while watching the piston through the spark plug hole. The piston should move up and down. The piston is at TDC when it is up as high as it can go.
Insert a 0.002 - 0.004 inch (0.05 - 0.1mm) feeler gauge between
the rocker arm and valve stem. Correct clearance is when a slight drag is felt when sliding the gauge back and forth. If the clearance is either excessively loose or tight the rocker arms will need adjusting.
To adjust valve clearance:
Loosen the rocker jam nut (Figure 20). Use an 10mm allen wrench
to turn the pivot ball stud while checking clearance between the rocker arm and the valve stem with a feeler gauge. Correct clearance is 0.002-0.004 inch (0.05-0.1 mm).
Figure 20 - Valve Clearance Adjustment
Spark Arrestor
Heat Shield
3.6 ADJUSTING VALVE CLEARANCE
After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary.
Important: If feeling uncomfortable about doing this procedure or
the proper tools are not available, please take the generator to the nearest service center to have the valve clearance adjusted. This is a very important step to insure longest life for the engine.
To check valve clearance:
Make sure the engine is at room temperature (60° - 80° F).
Make sure that the spark plug wire is removed from the spark plug
and out of the way. Remove spark plug.
Remove the four screws attaching the valve cover.
NOTE:
The rocker arm jam nut must be held in place as the pivot ball stud is turned.
When valve clearance is correct, hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to 174 in/lbs. torque. After tightening the jam nut, recheck valve clearance to make sure it did not change.
Install new valve cover gasket.
Re-attach the valve cover.
NOTE:
Start all four screws before tightening or it will not be possible to get all the screws in place. Make sure the valve cover gasket is in place. Replace spark plug.
Re-attach the spark plug wire to the spark plug.
13
Page 16
Section 3 — Maintenance
Portable Generator System
3.7 LONG TERM STORAGE
It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:
Remove all gasoline from the fuel tank.
DANGER
Drain fuel into approved container outdoors,

away from open flame. Be sure engine is cool. Do not smoke.
Start and run engine until engine stops from lack of fuel.
While engine is still warm, drain oil from crankcase. Refill with
recommended grade.
Remove spark plugs and pour about 1/2 ounce (15 ml) of engine
oil into the cylinders. Cover spark plug hole with rag. Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore..
3.8 OTHER STORAGE TIPS
Do not store gasoline from one season to another.
Replace the gasoline can if it starts to rust. Rust and/or dirt in the
gasoline will cause problems with the carburetor and fuel system.
If possible, store the unit indoors and cover it to give protection
from dust and dirt. BE SURE TO EMPTY THE FUEL TANK.
If it is not practical to empty the fuel tank and the unit is to be stored
for some time, use a commercially available fuel stabilizer added to the gasoline to increase the life of the gasoline.
Cover the unit with a suitable protective cover that does not retain
moisture.
DANGER
NEVER cover the generator while engine and
exhaust area are warm.
Avoid spray from spark plug holes when
cranking engine.
Install and tighten spark plugs. Do not connect spark plug wires.
Clean the generator outer surfaces. Check that cooling air slots
and openings on generator are open and unobstructed.
Store the unit in a clean, dry place.
14
Page 17
Section 4 — Troubleshooting
Portable Generator System
4.1 TROUBLESHOOTING GUIDE
PROBLEM CAUSE CORRECTION
Engine is running, but no AC
output is available.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good condition.
4. Contact Authorized Service Facility.
Engine runs good but bogs down
when loads are connected.
Engine will not start; or starts and
runs rough.
Engine shuts down during
operation.
Engine lacks power.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Fuel Shut-off is OFF.
2. Dirty air filter.
3. Out of gasoline.
4. Stale gasoline.
5. Spark plug wire not connected to spark plug.
6. Bad spark plug.
7. Water in gasoline.
8. Over-choking.
9. Low oil level.
10. Excessive rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Out of gasoline.
2. Low oil level.
3. Fault in engine.
1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
1. Disconnect shorted electrical load.
2. See “Don’t Overload the Generator” .
3. Contact Authorized Service Facility.
4. Contact Authorized Service Facility.
1. Turn Fuel Shut-off to ON.
2. Clean or replace air filter.
3. Fill fuel tank.
4. Drain fuel tank and fill with fresh fuel.
5. Connect wire to spark plug.
6. Replace spark plug.
7. Drain fuel tank; fill with fresh fuel.
8. Put choke knob to No Choke position.
9. Fill crankcase to proper level.
10. Contact Authorized Service Facility.
11. Contact Authorized Service Facility.
12. Contact Authorized Service Facility.
1. Fill fuel tank.
2. Fill crankcase to proper level.
3. Contact Authorized Service Facility.
1. Reduce load (see “Don’t Overload the Generator”).
2. Clean or replace air filter.
3. Contact Authorized Service Facility.
Engine “hunts” or falters.
1. Choke is opened too soon.
2. Carburetor is running too rich or too lean.
1. Move choke to halfway position until engine runs
smoothly.
2. Contact Authorized Service Facility.
15
Page 18
Section 5 — Notes
16
Page 19
Section 5 — Notes
17
Page 20
Section 6 — Warranty
Portable Generator System
GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR
GP SERIES PORTABLE GENERATORS
For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser. Save your proof-of-purchase receipt. If you do not provide proof of the initial purchase date, the manufacturer’s shipping date of the product will be used to determine the warranty period.
WARRANTY SCHEDULE
Consumer applications are warranted for two (2) years. Commercial and Rental applications are warranted for one (1) year or 1000 hours maximum, whichever comes first.
CONSUMER APPLICATION
YEARS ONE and TWO - 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
• Engine- All Components
• Alternator- All Components
COMMERCIAL/RENTAL APPLICATION
YEAR ONE – 100% (one hundred percent) coverage on Labor and Part(s) listed (proof of purchase and maintenance is required):
• Engine- All Components
• Alternator- All Components
NOTE: For the purpose of this warranty “consumer use” means personal residential household or recreational use by original purchaser. This warranty does not apply to units used for
Prime Power in place of utility where utility power service is present or where utility power service does not normally exist. Once a generator has experienced commercial or rental use, it shall thereafter be considered a non-consumer use generator for the purpose of this warranty.
All warranty expense allowances are subject to the conditions defined in Generac’s Warranty Policies, Procedures and Flat Rate Manual.
THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
Generac built portable generators built prior to May 2008.• Generac portable generators that utilize non-Generac replacement parts.• Costs of normal maintenance and adjustments.• Failures caused by any contaminated fuels, oils or lack of proper oil levels.• Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by Generac Power Systems.• Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper use. As with all mechanical devices, the Generac engines need periodic part(s) • service and replacement to perform as designed. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine. Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earth-quake, windstorm, hail, volcanic • eruption, water or flood, tornado or hurricane. Damage related to rodent and/or insect infestation.• Products that are modified or altered in a manner not authorized by Generac in writing.• Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).• Failure due to misapplication.• Telephone, cellular phone, facsimile, internet access or other communication expenses.• Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period.• Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.• Rental equipment used while warranty repairs are being performed.• Overnight freight or special shipping costs for replacement part(s).• Overtime, holiday or emergency labor.• Starting batteries, fuses, light bulbs and engine fluids.
THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. GENERAC’S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC’S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights. You also have other rights from state to state.
GENERAC POWER SYSTEMS, INC.
P.O. BOX 8 • Waukesha, WI 53187
Ph: (888) GENERAC (436-3722) • Fax: (262) 544-4851
To locate the nearest Authorized Dealer visit our website www.generac.com
Part No. 0G9451 Revision D (10/27/08) Printed in U.S.A.
Manual Part No. 0G8751 Rev B (11/11/08) Printed in U.S.A.