• Two Line LCD Tri-lingual
Digital Nexus™ Controller
• Electronic Governor
• External Main Circuit Breaker,
System Status & Maintenance
Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 3 Year Limited Warranty
• UL 2200 Listed
Standby Power Rating
Model 005882-1 (Steel - Bisque) - 8 kW 60Hz
Model 005883-1 (Steel - Bisque) - 10 kW 60Hz
Model 005884-1 (Steel - Bisque) - 14 kW 60Hz
FEATURES
¡INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
¡
TRUE POWER® ELECTRICAL TECHNOLOGY:Superior harmonics and
sine wave form produce less than 5% Total Harmonic Distortion for utility
quality power. This allows confident operation of sensitive electronic equipment
and micro-chip based appliances, such as variable speed HVAC.
¡TEST CRITERIA:
PROTOTYPE TESTED NEMA MG1-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
¡SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY
by electronically torque-matching the surge loads to the engine. An
unequalled ±1% voltage regulation.
¡SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
¡GENERAC TRANSFER SWITCHES.Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma
moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of
engine wear, the OHVI has a significantly longer life than competitive engines.
Rigid construction and added durability provide long engine life.
These features combine to assure smooth, quick starting every time.
Superior lubrication to all vital bearings means better performance, less maintenance and significantly
longer engine life. Now featuring a 2 year/200 hour oil change interval.
Superior shutdown protection prevents catastrophic engine damage due to low oil.
Prevents damage due to overheating.
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Produces a smooth output waveform for compatibility with electronic equipment.
Maximizes motor starting capability.
Regulates the output voltage to ±1% prevents damaging voltage spikes.
For your safety.
SWITCH
TRANSFER
•Manual/Auto/Off switch
•Utility voltage sensing
•Generator voltage sensing
•Utility interrupt delay
•Engine warm-up
•Engine cool-down
•Programmable seven day exerciser
NEXUS™ CONTROLS
•Smart battery charger
•Main Line Circuit Breaker
•Electronic governor
•Weather protective enclosure
•Enclosed critical grade muffler
UNIT
•Small, compact, attractive
Selects the operating mode.
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage.
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
Prevents nuisance start-ups of the engine, adjustable 10-30 seconds.
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages by running the
generator for 12 minutes every week.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Protects generator from overload.
Maintains constant 60 Hz frequency.
Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability.
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Rated Maximum Continuous Power Capacity (LP)8,000 Watts* 10,000 Watts* 14,000 Watts*
Rated Maximum Continuous Power Capacity (NG) 7,000 Watts*9,000 Watts* 13,000 Watts*
Rated Voltage240 240 240
Rated Maximum Continuous Load Current – 240 Volts33.3 LP/29.2 NG41.6 LP/37.5 NG58.3 LP/54.2 NG
Total Harmonic DistortionLess than 5%Less than 5%Less than 5%
Main Line Circuit Breaker35 Amp45 Amp60 Amp
Phase1 11
Number of Rotor Poles2 22
Rated AC Frequency60Hz60Hz60Hz
Power Factor111
Battery Requirement (not included) Group 26R 12 Volts and 525
Unit Weight (Pounds/Kilos)340/154.2387/175.4439/199.1
Dimensions (L x W x H) Inches/mm48 x 25 x 29 (1218 x 638 x 732)
Sound output in dB(A) at 23 ft. with generator operating at normal load626366
Type of EngineGENERAC OHVIGENERAC OHVI V-TWINGENERAC OHVI V-TWIN
Number of Cylinders122
Displacement410cc530cc992cc
Cylinder BlockAluminum w/Cast Iron SleeveAluminum w/Cast Iron SleeveAluminum w/Cast Iron Sleeve
Valve ArrangementOverhead ValveOverhead ValveOverhead Valve
Ignition SystemSolid-state w/MagnetoSolid-state w/MagnetoSolid-state w/Magneto
Governor SystemElectronicElectronicElectronic
Compression Ratio9.4:19.5:19.5:1
Starter12 Vdc12 Vdc12 Vdc
Oil Capacity Including FilterApprox. 1.5 Qts./1.4LApprox. 1.7 Qts./1.6LApprox. 1.9 Qts./1.8L
Operating RPM3,6003,6003,600
Fuel Consumption
Natural Gas
1/2 LoadFull Load
Liquid Propaneft3/hr (gal/hr) [Liter/hr]
1/2 LoadFull Load
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
For Btu content, multiply ft
cu.ft./hr.
3
/hr x 2520 (LP) or ft3/hr x 1000 (NG)
77
139
34 (0.94) [3.56]
62 (1.68) [6.36]
CONTROLS
2-Line Plain Text LCD Display (10 & 14 kW)Simple user interface for ease of operation.
Mode Switch
-Auto Automatic Start on Utility failure. 7 day exerciser.
-OffStops unit. Power is removed. Control and charger still operate.
-Manual/Test (start)Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 secondsStandard
Engine Start SequenceCyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration).
Engine Warm-up5 seconds
Engine Cool-Down1 minute
Starter Lock-outStarter cannot re-engage until 5 sec. after engine has stopped.
Smart Battery ChargerStandard
Automatic Voltage Regulation with Over and Under Voltage ProtectionStandard
Automatic Low Oil Pressure ShutdownStandard
Overspeed ShutdownStandard, 72Hz
High Temperature ShutdownStandard
Overcrank ProtectionStandard
Safety FusedStandard
Failure to Transfer ProtectionStandard
Low Battery ProtectionStandard
50 Event Run LogStandard
Future Set Capable ExerciserStandard
Incorrect Wiring ProtectionStandard
Internal Fault ProtectionStandard
Common External Fault CapabilityStandard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,
ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Every standby generator requires a battery to start the system. Generac offers the
recommended 26R wet cell battery for use with all air-cooled standby product.
If the temperature regularly falls below 32° F, install a cold weather kit to maintain
optimal battery temperature. Kit consists of battery warmer with thermostat built
into the wrap.
The auxiliary transfer switch contact kit allows the transfer switch to lock out a
single large electrical load you may not need.
5703Paint KitBisque Kit
5662 - 8kW
5663 - 10kW
Scheduled Maintenance Kit
5664 - 14kW
5928Nexus Wireless Remote
5951
Advanced Nexus Wireless
Remote
Generac's scheduled maintenance kits provide all the hardware necessary to
perform complete routine maintenance on a Generac automatic standby generator.
Completely wireless and battery powered, Generac's Nexus wireless remote monitor
provides you with instant status information without ever leaving the house.
Remotely control generator functions with the advanced model's LCD display. In
addition to remote testing of the generator, set the excercise cycle and maintenance
interval reminders.
5937
Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
DLM Load Control DLM
Module (50 Amps)
DLM Modules are used in conjunction with the Nexus Smart Switch to increase
its load management capabilities. It gives the Nexus Smart Switch additional load
management flexibility not found in any other transfer switch.
637.6
[25.1]
1218
[47.9]
731.9
[28.8]
642
[25.3]
LEFT SIDE VIEW
76.2 [3.0]
PEA GRAVEL
MINIMUM
1226
[48.3]
FRONT VIEW
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com