Generac 005818-O User Manual

®
6kW
6kW
INCLUDES:
• Electronic Governor
• External Main Circuit Breaker
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Composite Mounting Pad
• LP Gas Operation Only
• Advanced Oil Circulation System
• Easy Inverter Connections
EcoGen™ SERIES
Residential Standby Generators
Air-Cooled Gas Engine
1 of 4
Standby Power Rating
Model 005818-0 (Steel - Bisque) - 6 kW 60Hz
• 120V (240V Capable with Conversion)
• 2000 Hour / 3 Year Limited Warranty
• UL 2200 Listed
FEATURES
¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
PROTOTYPE TESTED NEMA MG1-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.
Not for sale in CA
¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network
provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
¡ PURPOSE BUILT FOR RENEWABLE ENERGY APPLICATIONS.
Designed specifically to interact with off-grid renewable energy applications, Generac introduces the first generator intended for alternative energy interaction. Capable of tying into an inverter and battery storage system to supplement the alternative energy source. This provides the cleanest running, low emission solution to recharging house batteries.
¡ EXTENDED RUN CAPABILITY. This innovative oil circulation system
extends the maintenance intervals by an unprecedented 5 times the industry standard by offering 500 hour maintenance intervals.
2 of 4
®
EcoGen™ - 6 kW features and benefits
6kW
Engine
•Generac (OHVI) Design Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life.
•“Spiny-lok” cast iron cylinder walls Rigid construction and added durability provide long engine life.
•Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
•Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
•Low oil pressure shutdown system Superior shutdown protection prevents catastrophic engine damage due to low oil.
•High temperature shutdown Prevents damage due to overheating.
•Spin-on automotive type oil filter Captures and collects harmful impurities with easy serviceability.
Oil circulatory system Extends maintenance intervals to 500 hours and virtually eliminates oil degradation.
Generator
•Revolving field
•Displaced phase excitation
•Automatic voltage regulation Regulates the output voltage to ±2% prevents damaging voltage spikes.
•UL 2200 Listed For your safety.
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Maximizes motor starting capability.
Controls
•Auto/Off/Manual switch Selects the operating mode.
•2-wire start/Inverter connection Allows the generator to be started by a two wire signal.
•Battery sentinel This smart system only charges the battery when needed, prolonging battery life.
•Main Line Circuit Breaker Protects generator from overload.
•Electronic governor Maintains constant 60 Hz frequency.
Unit
•Weather protective enclosure Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
•Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•Small, compact, attractive Makes for an easy, eye appealing installation.
•SAE Sound attenuated enclosure ensures quiet operation.
Installation System
•1’ Flexible Fuel Line Connector
Easy Installation.
•Composite Mounting Pad
®
EcoGen™ - 6 kW specifications
Generator
Model 005818-0 (6kW)
Rated Maximum Continuous Power Capacity (LP) 6,000* Watts
Rated Voltage 120 VAC (240 VAC capable w/kit)
Rated Maximum Continuous Load Current – 120 VAC 50 Amps (25 @240 VAC)
Main Line Circuit Breaker 50 Amps (25 after conversion)
Phase 1
Number of Rotor Poles 2
Rated AC Frequency 60Hz
Power Factor 1
Battery Requirement (not included) Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum
Unit Weight (Pounds/Kilos) 387/175.5
Dimensions (L x W x H) Inches/mm 48 x 25 x 29 [1218 x 638 x 732]
Sound output in dB(A) at 23 ft. with generator operating at normal load 52
Engine
Type of Engine GENERAC OHVI
Number of Cylinders 2
Displacement 530cc
Cylinder Block Aluminum w/Cast Iron Sleeve
Valve Arrangement Overhead Valve
Ignition System Solid-state w/Magneto
Governor System Electronic
Compression Ratio 9.5:1
Starter 12 Vdc
Oil Capacity Including Filter (quarts/liters) 1.7Q/1.6L
Oil Reservoir Capacity (quarts/liters) 4.2Q / 4.0L
Operating RPM 2,600 Fuel Consumption
Liquid Propane ft3/hr (gal/hr)
1/2 Load Full Load
Required fuel pressure to generator fuel inlet at all load ranges - 11 to 14 inches of water column for LP gas
For Btu content, multipy ft3/hr by 2520
30.8/0.85
48.2/1.32
6kW
3 of 4
Controls
2-Line Plain Text LCD Display Simple user interface for ease of operation. Mode Switch
-Auto Puts unit in standby mode, waiting for inverter start call.
-Off Stops unit. Power is removed. Control and charger still operate.
-Manual/Test (start) Start with starter control, unit stays on.
Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped.
2.5 Amp Smart Battery Charger Standard
Automatic Voltage Regulator w/Overvoltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard, 72Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Low Battery Protection Standard 50 Event Run Log Standard Internal Fault Protection Standard
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60°F). Sound output ratings from certain points on the generator
subject to change based on installation parameters.
®
EcoGen™ - 6 kW available accessories
TRANSFER
SWITCH
8KW - 17KW
(IF SUPPLIED)
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
H1
W1
W2
H2
H1
W1
W2
6kW
Model # Product Discription
®
4 of 4
5819 26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product.
The fascia base wrap snaps together around the bottom the new air-cooled
5839 Fascia Base Wrap Kit
generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base.
5703 Paint Kit Bisque Kit
6004 Scheduled Maintenance Kit
6016 240V Conversion Kit
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator.
As off-grid energy systems continue to grow in size and capacity, it is becoming more common to have a 240V instead of 120V only. This conversion kit allows the EcoGen to be converted easily from a 120V system to a 240V system and still maintain a full 6kW output.
dimensions
Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
637.6 [25.1]
1218
[47.9]
731.9 [28.8]
EcoGen Series
642
[25.3]
LEFT SIDE VIEW
76.2 [3.0]
PEA GRAVEL
MINIMUM
1226 [48.3]
FRONT VIEW
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0182260SBY-L Printed in U.S.A. 11/06/12
Loading...