Manual del propietario .........................................23
Manuel d'entretien ................................................ 45
Introduction
INTRODUCTION
Thank you for purchasing this model by Generac Power Systems, Inc.
This model is a compact, high performance, air-cooled, engine driven
generator designed to supply electrical power to operate electrical loads
where no utility power is available or in place of utility due to a power
outage.
READ THIS MANUAL THOROUGHLY
If any portion of this manual is not understood, contact the nearest
Authorized Dealer for starting, operating and servicing procedures.
The operator is responsible for proper and safe use of the equipment. We
strongly recommend that the operator read this manual and thoroughly
understand all instructions before using the equipment. We also strongly
recommend instructing other users to properly start and operate the
unit. This prepares them if they need to operate the equipment in an
emergency.
The generator can operate safely, efficiently and reliably only if it is
properly located, operated and maintained. Before operating or servicing
the generator:
• Become familiar with and strictly adhere to all local, state and national
codes and regulations.
• Study all safety warnings in this manual and on the product carefully.
• Become familiar with this manual and the unit before use.
The manufacturer cannot anticipate every possible circumstance that
might involve a hazard. The warnings in this manual, and on tags and
decals affixed to the unit are, therefore, not all inclusive. If using a
procedure, work method or operating technique that the manufacturer
does not specifically recommend, ensure that it is safe for others. Also
make sure the procedure, work method or operating technique utilized
does not render the generator unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN
PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE
RIGHT TO MODIFY THIS MANUAL AT ANY TIME.
SAFETY RULES
Throughout this publication, and on tags and decals affixed to the
generator, DANGER, WARNING, CAUTION and NOTE blocks are used to
alert personnel to special instructions about a particular operation that
may be hazardous if performed incorrectly or carelessly. Observe them
carefully. Their definitions are as follows:
Indicates a hazardous situation or action which, if not
avoided, will result in death or serious injury.
Indicates a hazardous situation or action which, if not
avoided, could result in death or serious injury.
NOTE:
Notes contain additional information important to a procedure and will
be found within the regular text body of this manual.
These safety warnings cannot eliminate the hazards that they indicate.
Common sense and strict compliance with the special instructions while
performing the action or service are essential to preventing accidents.
Four commonly used safety symbols accompany the DANGER, WARNING
and CAUTION blocks. The type of information each indicates is as
follows:
This symbol points out important safety
information that, if not followed, could endanger
personal safety and/or property of others.
This symbol points out potential explosion hazard.
This symbol points out potential fire hazard.
This symbol points out potential electrical shock
hazard.
GENERAL HAZARDS
• Never operate in an enclosed area or indoors.
• For safety reasons, the manufacturer recommends that the maintenance
of this equipment is carried out by an Authorized Dealer. Inspect the
generator regularly, and contact the nearest Authorized Dealer for parts
needing repair or replacement.
• Operate generator only on level surfaces and where it will not be
exposed to excessive moisture, dirt, dust or corrosive vapors.
• Keep hands, feet, clothing, etc., away from drive belts, fans, and other
moving parts. Never remove any fan guard or shield while the unit is
operating.
• Certain parts of the generator get extremely hot during operation. Keep
clear of the generator until it has cooled to avoid severe burns.
• Do NOT operate generator in the rain.
• Do not alter the construction of the generator or change controls which
might create an unsafe operating condition.
• Never start or stop the unit with electrical loads connected to
receptacles AND with connected devices turned ON. Start the engine
and let it stabilize before connecting electrical loads. Disconnect all
electrical loads before shutting down the generator.
• When working on this equipment, remain alert at all times. Never work
on the equipment when physically or mentally fatigued.
• Never use the gen=erator or any of its parts as a step. Stepping on the
unit can stress and break parts, and may result in dangerous operating
conditions from leaking exhaust gases, fuel leakage, oil leakage, etc.
Indicates a hazardous situation or action which, if not
avoided, could result in minor or moderate injury.
1
Safety Rules
SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's
installation site. Safety should be stressed to all operators and potential operators of this equipment.
EXHAUST & LOCATION HAZARDS
• Never operate in an enclosed area or indoors! NEVER use in the
home, or in partly enclosed areas such as garages, even if doors
and windows are open! ONLY use outdoors and far from open
windows, doors, vents, and in an area that will not accumulate
deadly exhaust.
• The engine exhaust fumes contain carbon monoxide, which you
cannot see or smell. This poisonous gas, if breathed in sufficient
concentrations, can cause unconsciousness or even death.
• Adequate, unobstructed flow of cooling and ventilating air is critical
to correct generator operation. Do not alter the installation or permit
even partial blockage of ventilation provisions, as this can seriously
affect safe operation of the generator. The generator MUST be operated
outdoors.
• This exhaust system must be properly maintained. Do nothing that
might render the exhaust system unsafe or in noncompliance with any
local codes and/or standards.
• Always use a battery operated carbon monoxide alarm indoors,
installed according to the manufacturers instructions.
• If you start to feel sick, dizzy, or weak after the generator has been
running, move to fresh air IMMEDIATELY. See a doctor, as you could
have carbon monoxide poisoning.
ELECTRICAL HAZARDS
• The generator produces dangerously high voltage when in operation.
Avoid contact with bare wires, terminals, connections, etc., while
the unit is running, even on equipment connected to the generator.
Ensure all appropriate covers, guards and barriers are in place before
operating the generator.
• Never handle any kind of electrical cord or device while standing in
water, while barefoot or while hands or feet are wet. DANGEROUS
ELECTRICAL SHOCK MAY RESULT.
• The National Electric Code (NEC) requires the frame and external
electrically conductive parts of the generator be properly connected
to an approved earth ground. Local electrical codes may also require
proper grounding of the generator. Consult with a local electrician for
grounding requirements in the area.
• Use a ground fault circuit interrupter in any damp or highly conductive
area (such as metal decking or steel work).
• Do not use worn, bare, frayed or otherwise damaged electrical cord
sets with the generator.
• In case of accident caused by electric shock, immediately shut down
the source of electrical power. If this is not possible, attempt to free
the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a non-conducting implement, such as a rope
or board, to free the victim from the live conductor. If the victim is
unconscious, apply first aid and get immediate medical help.
FIRE HAZARDS
• Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. Do
not permit smoking, open flames, sparks or heat in the vicinity
while handling gasoline.
• Never add fuel while unit is running or hot. Allow engine to cool
completely before adding fuel.
• Never fill fuel tank indoors. Comply with all laws regulating storage
and handling of gasoline.
• Do not overfill the fuel tank. Always allow room for fuel expansion.
If tank is over-filled, fuel can overflow onto a hot engine and cause
FIRE or an EXPLOSION. Never store generator with fuel in tank where
gasoline vapors might reach an open flame, spark or pilot light (as on
a furnace, water heater or clothes dryer). FIRE or EXPLOSION may
result. Allow unit to cool entirely before storage.
• Wipe up any fuel or oil spills immediately. Ensure that no combustible
materials are left on or near the generator. Keep the area surrounding
the generator clean and free from debris and keep a clearance of five
(5) feet on all side to allow for proper ventilation of the generator.
• Do not insert objects through unit’s cooling slots.
• Do not operate the generator if connected electrical devices overheat,
if electrical output is lost, if engine or generator sparks or if flames or
smoke are observed while unit is running.
• Keep a fire extinguisher near the generator at all times.
2
Safety Rules
STANDARDS INDEX
In the absence of pertinent standards, codes, regulations and laws,
the published information listed below may be used as a guideline for
operation of this equipment. Always reference the latest revision available
for the standards listed.
1. NFPA No. 70, NFPA HANDBOOK OF NATIONAL ELECTRIC CODE.
2. Article X, NATIONAL BUILDING CODE, available from the American
Insurance Association, 85 John Street, New York, N.Y. 10038.
3. AGRICULTURAL WIRING HANDBOOK, available from the Food and
Energy Council, 909 University Avenue, Columbia, MO 65201.
4. ASAE EP-3634, INSTALLATION AND MAINTENANCE OF FARM
STANDBY ELECTRICAL SYSTEMS, available from the American
Society of Agricultural Engineers, 2950 Niles Road, St. Joseph, MI
49085.
MODEL NO:
SERIAL NO:
Figure 1 - Generator ID Plate
ID Plate
CALIFORNIA PROPOSITION 65 WARNING
Engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects
and other reproductive harm.
CALIFORNIA PROPOSITION 65 WARNING
This product contains or emits chemicals known to the
State of California to cause cancer, birth defects and
other reproductive harm.
3
General Information
1.1 UNPACKING
• Set the palleted carton on a rigid flat surface.
• Remove staples along bottom of carton that fasten carton to pallet.
Open carton from top.
• Remove all packaging material.
• Remove separate accessory box.
• Lift carton off the generator.
• Remove generator from shipping pallet by removing bolts through the
shipping brackets (Figure 1).
Figure 1 - Bracket Removal
Shipping
Bracket (x4)
1.2 ASSEMBLY
The generator requires some assembly prior to using it. If problems arise
when assembling the generator, please call the Generator Helpline at
1-888-436-3722.
1.2.1 ASSEMBLING THE WHEEL KIT
The wheel kit is designed to greatly improve the portability of the
generator. A socket wrench with a 9/16” socket, a 1/2” socket, a 1/2”
wrench and a pair of pliers are the tools that will be needed for assembly
of the wheel kit.
NOTE:
The wheel kit is not intended for over-the-road use.
• Refer to Figure 2 and install the wheel kit as follows:
• Place the generator on a hard flat surface.
• Stand at the engine end of the unit and gently tilt the generator forward,
high enough to place wooden blocks beneath the cradle. This will allow
space to install the wheel assemblies.
• Attach an axle bracket assembly with attached sleeve to either side of
the frame. Ensure the sleeve faces outward.
• Slide the axle through the sleeves on the axle brackets.
• Slide one wheel with flat washer to the outside and a spacer to the
inside onto each end of the axle. Make sure the air inflation valve on
the wheel is facing outward.
• Insert retaining pins and using pliers, bend out the ends to prevent the
pins from falling out of the axle. Remove the wooden blocks.
1.1.1 ACCESSORY BOX
Check all contents. If any parts are missing or damaged locate an
authorized dealer at 1-888-436-3722.
Contents include:
• Wheel Axle • Bolt-on tubular handle
• 2 – Washers • 2 – Pneumatic Wheels
• 2 – Wheel Spacers • 2 – Axle Bracket Assemblies
• 2 – Cotter Pins • Bolt-on Foot
• 2 – Spark Plugs • Spark Plug Wrench
• Air Filter • Oil Filter
• Pre-cleaner • Battery Charge Cable
• 6 – Carriage Bolts, Washers, Nuts
1.2.2 ASSEMBLING THE HANDLE
• Attach the handle by aligning one side of the handle on the cradle, then
spread the handle around the cradle and let it spring into place. Secure
the handle to the frame using the 5/16’ hex head bolts provided. Check
each fastener to ensure that it is secure.
• Using the handle, lift the unit high enough to place wooden blocks
under the unit. Attach the front support foot to the underside of the
cradle using the 3/8” carriage bolts provided.
• Remove the shipping brackets from the cradle, if it has not already
been done.
4
Figure 2 - Handle Assembly
General Information
1.2.3 BATTERY CONNECTION
• The battery shipped with the generator has been provided fully charged.
Caution must be taken when connecting the battery.
NOTE:
A battery may lose some of it’s charge when not in use for prolonged
periods of time.
• Cut the tie wrap cable holding the RED and BLACK battery cables to
the stator.
• Connect the RED battery cable to the battery Positive terminal (+).
After making sure that the connection is tight, slip the rubber boot over
the terminal connection.
• Connect the BLACK battery cable to the battery Negative terminal (–).
Make sure the connection is tight.
• Double check all connections to ensure they are in the correct location
and secure. See Figure 3.
• Install the battery post covers (included).
Figure 3 - Battery Connections
Negative
Cable
5
Positive
Cable
Operation
2.1 KNOW THE GENERATOR
Read the Owner’s Manual and Safety Rules before operating this
generator.
Compare the generator to Figures 4 through 7 to become familiarized with
the locations of various controls and adjustments. Save this manual for
future reference.
1. 12 Volt DC, 10 Amp Receptacle – This receptacle allows the
capability to recharge a 12 volt DC storage battery with provided
battery charge cables.
2. 120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical
power for the operation of 120 Volt AC, 20 Amp, single-phase, 60
Hz electrical lighting, appliance, tool and motor loads.
3. 120 Volt AC, 20A Duplex GFCI Receptacle – Supplies ground fault
protected electrical power for operation of 120 volt AC 20 amp,
single-phase, 60 Hz electric lighting, appliances, tools and motor
loads.
4. 120 Volt AC, 30 Amp Locking Receptacle – Supplies electrical
power for the operation of 120 Volt AC, 30 Amp, single-phase, 60
Hz electrical lighting, appliance, tool and motor loads.
5. 120/240 Volt AC, 30 Amp Locking Receptacle – Supplies electrical
power for the operation of 120 and/or 240 Volt AC, 30 Amp, singlephase, 60 Hz, electrical lighting, appliance, tool and motor loads.
6. 120/240 Volt AC, 50 Amp Receptacle (17.5kW, Located on
underside of control panel)– Supplies electrical power for the
operation of 120/240 Volt AC, 50 Amp, single-phase, 60 Hz, welder
or motor loads.
7. Air Cleaner – Filters intake air as it is drawn into the engine.
8. Choke Knob – Used when starting a cold engine.
9. Winter/Summer Valve – See “Cold Weather Operation/De-icer”
section.
10. Circuit Breakers (AC) – Each receptacle is provided with a pushto-reset circuit breaker to protect the generator against electrical
overload. (50 amp uses toggle reset)
11. Fuel Tank – Tank holds 16 U.S. gallons of fuel.
12. Grounding Lug – Ground the generator to an approved earth ground
here. See "Grounding the Generator" for details.
13. Idle Control Switch – The idle control runs the engine at normal
(high) speeds when there is an electrical load present and runs the
engine at idle (low) speeds when a load is not present.
14. Start/Run/Stop Switch – Controls the operation of the generator.
15. Oil Fill – Use this point to add oil to engine.
16. Fuse - 10 Amp (Located at rear of control panel) – Protects the DC
control circuit from overload. If this fuse element has melted open
the engine will not be able to crank and start.
17. Hourmeter - Tracks hours of operation.
Figure 5 - Generator Controls
11
7
12
Figure 6 - Engine Control Panel
6
10
Figure 4 - Control Panel
1713
1
56
2
10
3
14
8
9
4
Operation
Figure 7 - Oil Fill
15
2.2 HOURMETER
The Hourmeter tracks hours of operation for scheduled maintenance:
There will be a one time break in "CHG OIL" message that flashes with the
elapsed time in hours and tenths after the first 30 hours of operation.
This message will actually begin flashing at 29 hours and disable itself at
31 hours providing a two hour window to perform the service.
There will be a subsequent "CHG OIL" message every 100 hours. The
message will flash one hour before and one hour after each 100 hour
interval, again providing a two hour window to perform service.
Every 200 hours the "SVC" icon on the lower left hand corner of the display
will flash. The message will flash one hour before and one hour after each
200 hour interval providing a two hour window to perform service.
When the hour meter is in the Flash Alert mode, the maintenance message
will always alternate with elapsed time in hours and tenths. The hours will
flash four times, then alternate with the maintenance message four times
until the meter resets itself.
Figure 8 - 120 Volt AC, 20 Amp, Duplex Receptacle
2.3.2 120 VAC, 20 AMP, GFCI RECEPTACLE
This unit is equipped with a ground fault circuit interrupter (GFCI). This
device meets applicable federal, state and local codes (Figure 9).
A GFCI receptacle is different from conventional receptacles. In the event
of a ground fault, a GFCI will trip and quickly stop the flow of electricity to
prevent serious injury.
Definition: Instead of following its normal safe path, electricity passes
through a persons body to reach the ground. For example, a defective
appliance can cause a ground fault.
A GFCI receptacle does NOT protect against circuit overloads, short
circuits, or shocks. For example, electric shock can still occur if a person
touches charged electrical wires while standing on a non-conducting
surface, such as a wood floor.
This is a 120 Volt outlet protected against overload by a 20 Amp pushto-reset circuit breaker (Figure 8). Use each socket to power 120 Volt
AC, single phase, 60 Hz electrical loads requiring up to a combined
2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, wellinsulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or
greater).
Keep extension cords as short as possible, preferably less than 15 feet
long, to prevent voltage drop and possible overheating of wires.
7
Operation
Testing the GFCI: Test the GFCI outlet every month as follows:
• Plug a test lamp into the receptacle.
• Start the generator, the test lamp should be on.
• Press the “Test” button located on the front of the receptacle to trip
the device.
• This should stop the flow of electricity making the lamp shut off. The
yellow trip indicator should now be on.
• To restore the flow of electricity, press the “Reset” button on the front
of the receptacle. If the GFCI does not perform in this manner, do not
use the receptacle. Contact a local service dealer.
• This outlet is protected against overload by a 20A push-to-reset
circuit breaker. Use the outlet to power 120V AC, single-phase, 60 Hz,
electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20
amps of current.
2.3.3 120 VAC, 30 AMP RECEPTACLE
Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire cord set
rated for 125 Volts AC at 30 Amps (or greater) to the plug (Figure 10).
Figure 10 - 120 VAC, 30 Amp Receptacle
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads
requiring up to 3600 watts (3.6 kW) of power at 30 Amps or 240 Volt AC,
60 Hz, single phase loads requiring up to 7200 watts (7.2 kW) of power
at 30 Amps. The outlet is protected by two 30 Amp push-to-reset circuit
breakers.
2.3.5 12 VOLT DC, 10 AMP RECEPTACLE
This receptacle permits recharging a 12-Volt automotive or utility style
storage battery with the battery charge cables provided (Figure 12).
This receptacle can not recharge 6-Volt batteries and can not be used to
crank an engine having a discharged battery. See the section "Charging a
Battery" before attempting to recharge a battery.
Figure 12 - 12 Volt DC, 10 Amp Receptacle
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads
requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is
protected by a 30 Amp push-to-reset circuit breaker.
2.3.4 120/240 VAC, 30 AMP RECEPTACLE
Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire
grounded cord set to the plug and to the desired load. The cord set should
be rated for 250 Volts AC at 30 Amps (or greater) (Figure 11).
Figure 11 - 120/240 VAC, 30 Amp Receptacle
2.3.6 120/240 VAC, 50 AMP RECEPTACLE
Use a NEMA 14-50 plug with this receptacle. Connect a 4-wire cord set
rated for 250 Volts AC at 50 Amps to the plug (Figure 13).
Figure 13 - 120/240 VAC, 50 Amp Receptacle
50 A
Use this receptacle to operate 120/240 Volt AC, 60 Hz electrical loads
requiring up to 12,000 watts (12.0 kW) of power. This receptacle is
protected by a 50 Amp 2-pole circuit breaker.
8
Operation
2.4 HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the generator
helpline at 1-888-436-3722.
2.4.1 GROUNDING THE GENERATOR
The National Electrical Code requires that the frame and external
electrically conductive parts of this generator be properly connected
to an approved earth ground (Figure 14). Local electrical codes may
also require proper grounding of the unit. For that purpose, generally,
connecting a No. 10 AWG (American Wire Gauge) stranded copper wire to
the grounding wing nut and to an earth-driven copper or brass grounding
rod (electrode) provides adequate protection against electrical shock.
However, local codes may vary widely. Consult with a local electrician
for grounding requirements in the area.
Figure 14 - Grounding the Generator
Generator Ground Lug
2.5 DON’T OVERLOAD THE GENERATOR
Overloading a generator in excess of its rated wattage capacity can result
in damage to the generator and to connected electrical devices. Observe
the following to prevent overloading the unit:
• Add up the total wattage of all electrical devices to be connected at one
time. This total should NOT be greater than the generator's wattage
capacity.
• The rated wattage of lights can be taken from light bulbs. The rated
wattage of tools, appliances and motors can usually be found on a
data label or decal affixed to the device.
• If the appliance, tool or motor does not give wattage, multiply volts
times ampere rating to determine watts (volts x amps = watts).
• Some electric motors, such as induction types, require about three
times more watts of power for starting than for running. This surge of
power lasts only a few seconds when starting such motors. Make sure
to allow for high starting wattage when selecting electrical devices to
connect to the generator:
1. Figure the watts needed to start the largest motor.
2. Add to that figure the running watts of all other connected loads.
The Wattage Reference Guide is provided to assist in determining how
many items the generator can operate at one time.
NOTE:
All figures are approximate. See data label on appliance for wattage
requirements.
Proper grounding of the generator will help prevent electrical shock
in the event of a ground fault condition in the generator or in connected
electrical devices. Proper grounding also helps dissipate static electricity,
which often builds up in ungrounded devices.
2.4.2 CONNECTING ELECTRICAL LOADS
DO NOT connect 240 Volt loads to 120 Volt receptacles. DO NOT connect
3-phase loads to the generator. DO NOT connect 50 Hz loads to the
generator.
• Let engine stabilize and warm up for a few minutes after starting.
• Plug in and turn on the desired 120 or 240 Volt AC, single phase, 60
Hz electrical loads.
• Add up the rated watts (or amps) of all loads to be connected at
one time. This total should not be greater than (a) the rated wattage/
amperage capacity of the generator or (b) circuit breaker rating of the
receptacle supplying the power. See "Don't Overload the Generator"
below.
* Allow 3 times the listed watts for starting these devices.
2.7 BEFORE STARTING THE GENERATOR
Prior to operating the generator, engine oil and gasoline will need to be
added, as follows:
2.7.1 ADDING ENGINE OIL
All oil should meet minimum American Petroleum Institute (API) Service
Class SJ, SL or better. Use no special additives. Select the oil's viscosity
grade according to the expected operating temperature (also see chart).
• Above 40° F, use SAE 30
• Below 40° F and down to 10° F, use 10W-30
• Below 10° F, use synthetic 5W-30
• Place generator on a level surface.
• Clean area around oil fill and remove oil fill cap and dipstick.
• Wipe dipstick clean.
• Slowly fill engine with oil through the oil fill opening until it reaches the
full mark. Stop filling occasionally to check oil level. (Engine oil is full
when level is up to the threads of the oil fill plug.) Do not overfill.
• Install oil fill cap and finger tighten securely.
• Check engine oil level before starting each time thereafter.
2.7.2 ADDING GASOLINE
Never fill fuel tank indoors. Never fill fuel tank
when engine is running or hot. Allow unit/engine
to cool entirely before adding fuel. DO NOT light a
cigarette or smoke when filling the fuel tank.
Do not overfill the fuel tank. Always leave room
for fuel expansion.
• To reduce lead and carbon deposits use high quality UNLEADED
gasoline with the generator engine. Leaded REGULAR grade gasoline
is an acceptable substitute. Do not use premium gasoline. Do not mix
oil with gasoline.
• Clean area around fuel fill cap, remove cap.
• Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill. Allow about 1/2" of tank space for fuel expansion, as shown
in Figure 15.
• Install fuel cap and wipe up any spilled gasoline.
Figure 15 - Fuel Tank
Any attempt to crank or start the engine
before it has been properly serviced with the
recommended oil may result in an engine failure.
SAE 30
10W-30
Synthetic 5W-30
10
IMPORTANT: It is important to prevent gum deposits from forming in fuel
system parts such as the carburetor, fuel hose or tank during storage.
Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract
moisture, which leads to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine while in storage. To
avoid engine problems, the fuel system should be emptied before storage
of 30 days or longer. See the "Storage" section. Never use engine or
carburetor cleaner products in the fuel tank as permanent damage may
occur.
The manufacturer does not recommend using any
gasoline containing alcohol (such as “gasohol”).
If using any gasoline containing alcohol, it must
not contain more than 10 percent ethanol, and
it must be removed from the generator during
storage. Do NOT use any gasoline containing
methanol. If using gasoline with alcohol,
inspect more frequently for fuel leaks and other
abnormalities.
2.8 TO START THE ENGINE
Never start or stop engine with electrical devices
plugged into the receptacles AND devices turned
on.
• Unplug all electrical loads from the unit's receptacles before starting
the engine.
• Make sure the unit is in a level position.
• Open the fuel shut-off valve (Figure 16).
Operation
• Locate the Idle Control ON/OFF switch on the control panel and set it
to the “OFF” position (Figure 17).
Figure 17 - Idle Control Switch
• Move engine CHOKE knob outward to “Full Choke” position (Figure
18).
Figure 18 - Full Choke Position
Never operate in an enclosed area or indoors!
NEVER use in the home, or in partly enclosed
areas such as garages, even if doors and
windows are open! ONLY use outdoors and far
from open windows, doors, vents, and in an area
that will not accumulate deadly exhaust.
Figure 16 - Fuel Shut-off Valve
• To start engine, press and hold the Start/Run/Stop switch in the “Start”
position. The engine will crank and attempt to start. When the engine
starts, release the switch to the run position.
• When the engine starts, move choke knob to “1/2 Choke” position
until the engine runs smoothly and then fully in to the “Run” position.
If engine falters, move choke knob back out to “1/2 Choke” position
until the engine runs smoothly and then to “Run” position.
NOTE:
If engine fires, but does not continue to run, move choke lever to “Full
Choke” and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against overload
with push-to-reset-type circuit breakers. If amperage rating of any circuit
breaker is exceeded, that breaker opens and electrical output to that
receptacle is lost. Read “Don’t Overload the Generator” carefully.
11
Operation
2.9 STOPPING THE ENGINE
• Shut off all loads, then unplug the electrical loads from generator panel
receptacles. Never start or stop the engine with electrical devices
plugged in and turned on.
• Turn “Off” the Idle Control switch (if on).
• Let engine run at no-load for several minutes to stabilize the internal
temperatures of engine and generator.
• Move Start/Run/Stop switch to “Off” position.
• Close fuel valve.
2.10 AUTOMATIC IDLE CONTROL
This feature is designed to greatly improve fuel economy. When this switch
is turned “On,” the engine will only run at its normal fast governed engine
speed when electrical load is connected. When the load is removed, the
engine will run at a reduced speed of 2100 RPM. With the switch “Off,”
the engine runs at the normal fast engine speed all the time. Always have
the switch OFF when starting and stopping the engine.
2.11 COLD WEATHER OPERATION/DE-ICER
Under certain weather conditions (temperatures below 40° F (4° C) and a
high dew point), the engine may experience icing of the carburetor and/or
the crankcase breather system. To eliminate this problem, this generator
engine is fitted with a winter/summer valve. This directs hot air into the
carburetor during cold weather operation. Always make sure the winter/
summer valve is in the correct location relative to the weather conditions.
2.13 CHARGING A BATTERY
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion. Such
an explosion can shatter the battery and cause
blindness or other serious injury.
Do not permit smoking, open flame, sparks or
any other source of heat around a battery. Wear
protective goggles, rubber apron and rubber
gloves when working around a battery. Battery
electrolyte fluid is an extremely caustic sulfuric
acid solution that can cause severe burns. If spill
occurs flush area with clear water immediately.
This generator has the capability of recharging a discharged 12 Volt
automotive or utility style storage battery. Do not use the unit to charge
any 6 Volt batteries. Do not use the unit to crank an engine having a
discharged battery.
This battery charger is a pulse type designed to provide a quality charge
current into the battery. The voltage measured at the outlet should be 8-12
VDC. This is normal and does not indicate a faulty charging system.
2.12 LOW OIL PRESSURE SHUTDOWN
SYSTEM
The engine is equipped with a low oil pressure sensor that shuts down
the engine automatically when the oil pressure drops below 10 psi. If the
engine shuts down by itself and the fuel tank has enough gasoline, check
engine oil level.
2.12.1 INITIAL START-UP
A delay built into the low oil shutdown system allows oil pressure to build
during starting. The delay allows the engine to run for about 10 seconds
before sensing oil pressure.
2.12.2 SENSING LOW OIL PRESSURE
If the system senses low oil pressure during operation, the engine shuts
down.
2.12.3 RESTARTING
If trying to restart the engine within 10 seconds after it shuts down, the
engine may NOT start. The system needs five (5) to 10 seconds to reset.
If the engine is restarted after such a shutdown and the low oil pressure
has not been corrected, the engine will run for about 10 seconds as
described above and then stop.
To recharge 12 Volt batteries, proceed as follows:
• Check fluid level in all battery cells. If necessary, add ONLY distilled
water to cover separators in battery cells. Do not use tap water.
• If the battery is equipped with vent caps, make sure they are installed
and are tight.
• If necessary, clean battery terminals.
• Connect battery charge cable connector plug to panel receptacle
identified by the words "12-VOLT D.C."
• Connect battery charge cable clamp with red handle to the positive (+)
battery terminal.
• Connect battery charge cable clamp with black handle to the negative
(-) battery terminal.
• Start engine. Let the engine run while battery recharges. Engine idle
control switch must be in off position for battery charging.
• When battery has charged, shut down engine.
NOTE:
Use an automotive hydrometer to test battery state of charge and
condition. Follow the hydrometer manufacturer's instructions carefully.
Generally, a battery is considered to be at 100% state of charge when
specific gravity of its fluid (as measured by hydrometer) is 1.260 or
higher.
12
Maintenance
3.1 PERFORMING SCHEDULED
MAINTENANCE
It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the generator
complies with the applicable emission standards for the duration of its
useful life. Service and repairs may be performed by any capable person
or repair shop. Additionally, emissions critical maintenance must be
performed as scheduled in order for the Emissions Warranty to be valid.
Emissions critical maintenance consists of servicing the air filter and spark
plugs in accordance with the Maintenance Schedule.
3.2 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required when
operating in adverse conditions noted below.
Check Oil Level At Each Use
Change Oil ‡ *Every 100 hours or Every Season
Check Valve Clearance ***Every Season
Service Air Filter ** Every 200 hours or Every Season
Replace Spark Plug Every Season
‡ Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
3.3 PRODUCT SPECIFICATIONS
3.3.1 GENERATOR SPECIFICATIONS
MODEL15 KW17.5 KW
Rated Max. Power15.0 kW17.5 kW
Surge Power22.5 kW26.25 kW
Rated AC Voltage120/240120/240
Rated Max AC Load
Current @ 240V62.5 Amps72.9 Amps
Current @ 120V125.0 Amps145.8 Amps
Rated Frequency60 Hz @ 3600 RPM60 Hz @3600 RPM
PhaseSingle PhaseSingle Phase
Rated DC Voltage12 Volts12 Volts
Rated Max DC Load
Current @ 12 Volts10 Amperes10 Amperes
Weight373 lbs.400 lbs.
3.3.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM30
Displacement992cc
Spark Plug TypeChampion RC14YC or Equivalent
Spark Plug Gap0.040 inch or (1.01 mm)
Gasoline Capacity16 U.S. gallons
Oil TypeSummer – SAE 30, Winter –
5W-30 Synthetic or 10W-30
Oil Capacityw/ Filter Change = 1.7 Qts., w/o
Filter Change = 1.4 Qts.
Run Time/Fuel Consumption-1/2
Load
10 Hours / 1.6 gallons per hour
3.3.3 EMISSIONS INFORMATION
The Environmental Protection Agency (and California Air Resource Board
for generators certified to CA standards) require(s) that this generator
comply with exhaust and evaporative emission standards. Locate the
emissions compliance decal on the engine to determine what standards
the generator meets. This generator is certified to operate on gasoline. The
emission control system consists of the following:
• Air Induction System
~ Intake Pipe / Manifold
~ Air Cleaner
• Fuel System
~ Carburetor
~ Fuel Tank / Cap
~ Fuel Lines
~ Evaporative Vent Lines
~ Carbon Canister (for CA engines only)
• Ignition System
~ Spark Plug
~ Ignition Module
• Exhaust System
~ Exhaust Manifold
~ Muffler
~ Catalyst (for CA engines only).
3.4 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value from the
warranty, the operator must maintain the generator as instructed in this
manual.
Some adjustments will need to be made periodically to properly maintain
the generator.
All adjustments in the Maintenance section of this manual should be made
at least once each season. Follow the requirements in the "Maintenance
Schedule" chart.
NOTE:
Once a year, replace the spark plug and replace the air filter. A new
spark plug and clean air filter assure proper fuel-air mixture and help
the engine run better and last longer.
13
Maintenance
3.4.1 GENERATOR MAINTENANCE
Generator maintenance consists of keeping the unit clean and dry. Operate
and store the unit in a clean dry environment where it will not be exposed
to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots
in the generator must not become clogged with snow, leaves, or any other
foreign material.
Check the cleanliness of the generator frequently and clean when dust,
dirt, oil, moisture or other foreign substances are visible on its exterior
surface.
Never insert any object or tool through the air
cooling slots, even if the engine is not running.
NOTE:
DO NOT use a garden hose to clean generator. Water can enter the
engine fuel system and cause problems. In addition, if water enters
the generator through cooling air slots, some water will be retained in
voids and crevices of the rotor and stator winding insulation. Water and
dirt buildup on the generator internal windings will eventually decrease
the insulation resistance of these windings.
3.4.2 TO CLEAN THE GENERATOR
• Use a damp cloth to wipe exterior surfaces clean.
• A soft, bristle brush may be used to loosen caked on dirt, oil, etc.
• A vacuum cleaner may be used to pick up loose dirt and debris.
• Low pressure air (not to exceed 25 psi) may be used to blow away
dirt. Inspect cooling air slots and openings on the generator. These
openings must be kept clean and unobstructed.
3.4.3 ENGINE MAINTENANCE
NOTE:
Whenever possible, run engine for approximately five (5) minutes to
get the engine oil hot. This will aid in draining the oil.
Use the following instructions to change the oil while the engine is still
warm:
• Clean area around oil drain hose and plug.
• Remove oil drain plug from end of hose and oil fill plug to drain oil
completely into a suitable container.
• When oil has completely drained, install oil drain plug and tighten
securely.
• Place a suitable container beneath the oil filter and turn filter
counterclockwise to remove. Discard according to local regulations.
• Coat gasket of new filter with clean engine oil. Turn filter clockwise until
gasket contacts lightly with filter adapter. Then tighten an additional
3/4 turn.
• Fill oil sump with recommended oil. (See “Before Starting the
Generator” for oil recommendations).
• Wipe up any spilled oil.
• Dispose of used oil at a proper collection center.
3.4.6 REPLACING THE SPARK PLUGS
Use Champion RC14YC spark plug or equivalent. The correct air gap is
1.01 mm (0.040 in.). Replace the plugs once each year. This will help
the engine start easier and run better.
1. Stop the engine and pull the spark plug wire off of the spark plug.
2. Clean the area around the spark plug and remove it from the cylinder
head.
3. Set the spark plug's gap to 1.01 mm (0.040 in.). Install the correctly
gapped spark plug into the cylinder head.
Figure 19 - Spark Plug Gap
When working on the generator, always disconnect
negative cable from battery. Also disconnect spark
plug wires from spark plugs and keep wire away
from spark plugs.
3.4.4 CHECKING OIL LEVEL
See the “BEFORE STARTING THE GENERATOR” section for information on
checking the oil level. The oil level should be checked before each use, or
at least every eight hours of operation. Keep the oil level maintained.
Hot oil may cause burns. Allow engine to cool
before draining oil. Avoid prolonged or repeated
skin exposure with used oil. Thoroughly wash
exposed areas with soap.
3.4.5 CHANGING THE OIL AND OIL FILTER
Change the oil and filter after the first 30 hours of operation. Change the
oil every 100 hours thereafter. If running this unit under dirty or dusty
conditions, or in extremely hot weather, change the oil more often.
14
3.5 SERVICE AIR CLEANER
The engine will not run properly and may be damaged if using a dirty air
cleaner. Clean or replace the air cleaner paper filter every 200 hours. Clean
or replace more often if operating under dusty conditions. Clean foam precleaner every month or more often under dusty conditions.
To clean or replace foam pre-cleaner:
• Remove air cleaner cover, then foam pre-filter.
• Wash pre-cleaner in soapy water. Squeeze pre-filter dry in clean cloth
(DO NOT TWIST).
• Clean air cleaner cover before re-installing it.
Maintenance
To clean or replace paper air filter:
• Remove air cleaner cover; then remove foam pre-filter (service if
necessary) and remove paper filter.
• Clean paper filter by tapping it gently on a solid surface. If the filter is
too dirty, replace it with a new one. Dispose of the old filter properly.
• Clean air cleaner cover then slip pre-cleaner over filter. Next insert new
paper filter into the base of the air cleaner. Re-install air cleaner cover.
NOTE:
To order a new air filter, please contact the nearest authorized service
center at 1-800-333-1322.
Figure 20 - Air Cleaner
Cover
Pre-Cleaner
Base
Filter
Figure 20 - Spark Arrestor
3.7 ADJUSTING VALVE CLEARANCE
After the first 50 hours of operation, check the valve clearance in the
engine and adjust if necessary.
Important: If feeling uncomfortable about doing this procedure or the
proper tools are not available, please take the generator to the nearest
service center to have the valve clearance adjusted. This is a very
important step to insure longest life for the engine.
3.6 CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect and clean
the screen at least once each year (Figure 20). If unit is used regularly,
inspect and clean more often.
NOTE:
If using the generator on any forest-covered, brush-covered or grasscovered unimproved land, it must equipped with a spark arrestor. The
spark arrestor must be maintained in good condition by the owner/
operator.
Clean and inspect the spark arrestor as follows:
• Remove the screen retaining bracket by removing the screw.
• Slide the spark arrestor screen out from the tail pipe.
• Inspect screen and replace if torn, perforated or otherwise damaged.
DO NOT USE a defective screen. If screen is not damaged, clean it with
commercial solvent.
• Replace the screen and the retaining bracket.
To check valve clearance:
• Make sure the engine is at room temperature (60° - 80° F).
• Make sure that the spark plug wire is removed from the spark plug and
out of the way.
• Remove the four screws attaching the valve cover.
• Make sure the piston is at Top Dead Center (TDC) of its compression
stroke (both valves closed). To get the piston at TDC, remove the
intake screen at the front of the engine to gain access to the flywheel
nut. Use a large socket and socket wrench to rotate the nut and hence
the engine in a clockwise direction while watching the piston through
the spark plug hole. The piston should move up and down. The piston
is at TDC when it is up as high as it can go.
• Insert a 0.002 - 0.004 inch (0.05 - 0.1mm) feeler gauge between the
rocker arm and valve stem. Correct clearance is when a slight drag is
felt when sliding the gauge back and forth. If the clearance is either
excessively loose or tight the rocker arms will need adjusting.
To adjust valve clearance:
• Loosen the rocker jam nut (Figure 21). Use an 10mm allen wrench to
turn the pivot ball stud while checking clearance between the rocker
arm and the valve stem with a feeler gauge. Correct clearance is
0.002-0.004 inch (0.05-0.1 mm).
NOTE:
The rocker arm jam nut must be held in place as the pivot ball stud
is turned.
15
Maintenance
Figure 21 - Valve Clearance Adjustment
When valve clearance is correct, hold the pivot ball stud in place with the
allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to
174 in/lbs. torque. After tightening the jam nut, recheck valve clearance to
make sure it did not change.
• Install new valve cover gasket.
• Re-attach the valve cover.
NOTE:
Start all four screws before tightening or it will not be possible to get
all the screws in place. Make sure the valve cover gasket is in place.
• Re-attach the spark plug wire to the spark plug.
• Repeat the process for the other cylinder.
3.8 GENERAL
The generator should be started at least once every seven days and be
allowed to run at least 30 minutes. If this cannot be done and the unit must
be stored for more than 30 days, use the following information as a guide
to prepare it for storage.
NEVER store engine with fuel in tank indoors or
in enclosed, poorly ventilated areas where fumes
may reach an open flame, spark or pilot light as on
a furnace, water heater, clothes dryer or other gas
appliance.
3.9 LONG TERM STORAGE
It is important to prevent gum deposits from forming in essential fuel
system parts such as the carburetor, fuel hose or tank during storage.
Also, experience indicates that alcohol-blended fuels (called gasohol,
ethanol or methanol) can attract moisture, which leads to separation and
formation of acids during storage. Acidic gas can damage the fuel system
of an engine while in storage.
To avoid engine problems, the fuel system should be emptied before
storage of 30 days or longer, as follows:
• Remove all gasoline from the fuel tank.
Drain fuel into approved container outdoors, away
from open flame. Be sure engine is cool. Do not
smoke.
• Start and run engine until engine stops from lack of fuel.
• While engine is still warm, drain oil from crankcase. Refill with
recommended grade.
• Remove spark plugs and pour about 1/2 ounce (15 ml) of engine oil
into the cylinders. Cover spark plug hole with rag. Press the “Start”
button and allow engine to crank for 2 seconds. Then press the “Stop”
button.
• Remove the black battery cable from the battery post indicated by a
negative, NEG or (-) and attach to frame ground.
Avoid spray from spark plug holes when cranking
engine.
• Install and tighten spark plugs. Do not connect spark plug wires.
• Clean the generator outer surfaces. Check that cooling air slots and
openings on generator are open and unobstructed.
• Store the unit in a clean, dry place.
3.10 OTHER STORAGE TIPS
• Do not store gasoline from one season to another.
• Replace the gasoline can if it starts to rust. Rust and/or dirt in the
gasoline will cause problems with the carburetor and fuel system.
• If possible, store the unit indoors and cover it to give protection from
dust and dirt. BE SURE TO EMPTY THE FUEL TANK.
• If it is not practical to empty the fuel tank and the unit is to be stored
for some time, use a commercially available fuel stabilizer added to the
gasoline to increase the life of the gasoline.
• Cover the unit with a suitable protective cover that does not retain
moisture.
16
NEVER cover the generator while engine and/or
exhaust area are warm.
4.1 TROUBLESHOOTING GUIDE
PROBLEMCAUSECORRECTION
Engine is running, but no AC
output is available.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in good
condition.
4. Contact Authorized Service Facility.
Troubleshooting
Engine runs good but
bogs down when loads are
connected.
Engine will not crank.1.10 amp fuse at rear of generator control panel
Engine will not start; or
starts and runs rough.
Engine shuts down during
operation.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
has melted open.
2. Battery weak or dead.
1. Dirty air cleaner.
2. Out of gasoline.
3. Stale gasoline.
4. Spark plug wire not connected to spark plug.
5. Bad spark plug.
6. Water in gasoline.
7. Overchoking.
8. Low oil level.
9. Excessive rich fuel mixture.
10. Intake valve stuck open or closed.
11. Engine has lost compression.
1. Out of gasoline.
2. Low oil level.
3. Fault in engine.
1. Disconnect shorted electrical load.
2. See “Don’t Overload the Generator”
3. Contact Authorized Service Facility.
4. Contact Authorized Service Facility.
1. Replace fuse with only an identical 10-amp
replacement fuse.
2. Recharge or replace battery.
1. Clean or replace air cleaner.
2. Fill fuel tank.
3. Drain fuel tank and fill with fresh fuel.
4. Connect wire to spark plug.
5. Replace spark plug.
6. Drain fuel tank; fill with fresh fuel.
7. Put choke knob to No Choke position.
8. Fill crankcase to proper level.
9. Contact Authorized Service Facility.
10. Contact Authorized Service Facility.
11. Contact Authorized Service Facility.
1. Fill fuel tank.
2. Fill crankcase to proper level.
3. Contact Authorized Service Facility.
.
Engine lacks power.1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
Engine “hunts” or falters.1. Choke is opened too soon.
2. Carburetor is running too rich or too lean.
No Battery Charge DC
output.
1. Battery posts are corroded.
2. Battery cable is bad.
3. Battery is defective.
4. Receptacle is bad.
1. See “Don’t Overload the Generator”.
2. Replace air filter.
3. Contact Authorized Service Facility.
1. Move choke to halfway position until engine
runs smoothly.
2. Contact Authorized Service Facility.
1. Clean battery posts.
2. Replace cable.
3. Check battery condition; replace if defective.
4. Contact Authorized Service Facility.