• External Main Circuit Breaker
& System Status LED
(10 kW & 14 kW)
• Flexible Fuel Line Connector
• Composite Mounting Pad
• Natural Gas or LP Gas Operation
• UL 2200 Listed
Continuous Standby Power Rating
Model 005518-1 (Steel - Bisque) - 8 kW 60Hz
Model 005520-1 (Steel - Bisque) - 10 kW 60Hz
Model 005522-1 (Steel - Bisque) - 14 kW 60Hz
FEATURES
¡INNOVATIVE DESIGN & PROTOTYPE TESTING are key components
of GENERAC’S success in “IMPROVING POWER BY DESIGN.”
But it doesn’t stop there. Total commitment to component testing,
reliability testing, environmental testing, destruction and life testing,
plus testing to applicable CSA, NEMA, EGSA, and other standards,
allows you to choose GENERAC POWER SYSTEMS with the
confidence that these systems will provide superior performance.
and sine wave form produce less than 5% Total Harmonic Distortion for
utility quality power. This allows confident operation of sensitive electronic
equipment and micro-chip based appliances, such as variable speed HVAC.
¡TEST CRITERIA:
PROTOTYPE TESTED NEMA MG1-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
¡SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque-matching the surge loads to the engine.
¡SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network
provides parts and service know-how for the entire unit, from the engine
to the smallest electronic component.
¡GENERAC TRANSFER SWITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
FEATURESStandby Generator - 8 kW - 10 kW - 14 kW
•Generac (OHVI) Design
•”Spiny-lok” cast iron cylinder walls
•Electronic ignition/spark advance
•Full pressure lubrication system
ENGINE
•Low oil pressure shutdown system
•High temperature shutdown
•Revolving field
• Skewed rotor (8 & 10 kW)
Skewed stator (14 kW)
•Displaced phase excitation
•Automatic voltage regulation
GENERATOR
•UL 2200 Listed
Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma
moly rings help engine run cooler, reducing oil consumption. Because heat is the primary cause of
engine wear, the OHVI has a significantly longer life than competitive engines.
Rigid construction and added durability provide long engine life.
These features combine to assure smooth, quick starting every time.
Superior lubrication to all vital bearings means better performance, less maintenance and
significantly longer engine life. Now featuring a 2 year/200 hour oil change interval.
Superior shutdown protection prevents catastrophic engine damage due to low oil.
Prevents damage due to overheating.
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
Produces a smooth output waveform for compatibility with electronic equipment.
Maximizes motor starting capability.
Regulates the output voltage to ±2% prevents damaging voltage spikes.
For your safety
Sold separately
SWITCH
TRANSFER
•Manual/Auto/Off switch
•Utility voltage sensing
•Utility interrupt delay
•Engine warm-up
•Engine cool-down
•Seven day exerciser
CONTROLS
•Timed Trickle Battery charger
•Main Line Circuit Breaker
•Electronic governor (10 & 14 kW)
•Weather protective enclosure
UNIT
•Enclosed critical grade muffler
Selects the operating mode.
Constantly monitors utility voltage, setpoints 65% dropout, 75% pick-up, of standard voltage.
Prevents nuisance start-ups of the engine, setpoint approximately 10 seconds.
Ensures engine is ready to assume the load, setpoint approximately 10 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages.
Maintains battery charge level to insure starting.
Protects generator from overload.
Maintains constant 60 Hz frequency.
Ensures protection against mother nature. Hinged key locking roof panel for security.
Lift-out front for easy access to all routine maintenance items. Electrostatically applied
textured epoxy paint for added durability.
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas
Iron Sleeve
77
139
34 (0.94)
62 (1.68)
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
Aluminum w/Cast
Iron Sleeve
102
156
46 (1.25)
70 (1.93)
Group 26R
12 Volts and
525 Cold-cranking
Amperes Minimum
Aluminum w/Cast
Iron Sleeve
156
220
58 (1.56)
84 (2.30)
CONTROLS
2-Line Plain Text LCD Display (10 & 14 kW)Simple user interface for ease of operation
Mode Switch
-Auto Automatic Start on Utility failure. 7 day exerciser
-OffStops unit. Power is removed. Control and charger still operate.
-Manual/Test (start)Start with star ter control, unit stays on. If utility fails, transfer to load takes place.
Engine Start SequenceCyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration)
Engine Warm-up10 seconds
Engine Cool-Down1 minute
Starter Lock-outStarter cannot re-engage until 5 sec. after engine has stopped.
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
731.9
[28.8]
637.6
[25.1]
LEFT SIDE VIEW
642
[25.3]
76.2 [3.0]
PEA GRAVEL
MINIMUM
TRANSFER
SWITCH
8KW - 17KW
(IF SUPPLIED)
TRANSFER
SWITCH
20KW
(IF SUPPLIED)
1218
[47.9]
FRONT VIEW
1226
[48.3]
H1
W1
W2
H2
H1
W1
W2
Standby Generator - 8 kW - 10 kW - 14 kW
®
Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Generac dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com