Dimensions
WH D
Rack mount chassis (mm) 480 530 113 *
(inches) 187/8207/847/
16
Speaker cable adapter (mm) 118 67 57
(inches) 45/825/821/
4
* Without Speakon connecting cable.
Cable connectors require additional
100 mm (4 inches) of space behind the
amplifier
1
3
2
4
5
1
3
2
4
Fig. 3. Installing the speaker cable adapter
1 Speaker cable connector
2 Speaker cable adapter
3 4 x 12 mm screw
4 Speakon 8- and 4-pole cables
(not included in the kit)
Fig. 2. Mounting the amplifier into the
rack adapter chassis
1 M4 screw
2 Amplifier unit
3 Rack adapter cable connector
4 Rack adapter chassis
5 Speakon 8- and 4-pole cables
(not included in the kit)
Place the amplifier on the rack adapter
chassis and fix it with six M4 screws
(see fig 2.). Ensure that the rack adapter
cables do not tighten or press against
any amplifier components.
Connect the Speakon cables to the rack
adapter (see fig. 2.). Push the connector
in and turn it clockwise until the
retaining clip clicks.
The rack adapter can now be mounted
into a standard 19 inch rack. The
adapter chassis height is 12 U, but a
well ventilated free space of at least 1 U
(4,45 cm) is required above and below
to ensure adequate cooling, making the
total space requirement of the assembly
14 U. Please notice that Speakon cable
connectors require additional 100 mm
(4 inches) of space behind the
amplifier.
Attach the speaker cable adapter to the
speaker box with four 4 x 12 mm screws
(see fig. 3.). Connect the speaker cables
and the Speakon cables to the adapter.
Place the speaker into its recess. Now
the system is ready for operation.