Gems warrants to the original purchaser of its products that such products will be free from defects in material and
workmanship under normal use and service for a period which is equal to the shorter of one year from the date of
purchase of such products or two years from the date of manufacture of such products.
This warranty covers only those components of the products which are non-moving and not subject to normal wear.
Moreover, products which are modifi ed or altered, and electrical cables which are cut to length during installation are
not covered by this warranty.
Gems’ obligation under this warranty is solely and exclusively limited to the repair or replacement, at Gems’ option, of
the products (or components thereof) which Gems’ examination proves to its satisfaction to be defective. Gems SHALL
HAVE NO OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSONAL OR REAL PROPERTY, OR FOR INJURY
TO ANY PERSON.
This warranty does not apply to products which have been subject to improper use, accident, negligence, abuse or misuse.
Abuse shall be assumed when indicated by electrical damage to relays, reed switches or other components. The warranty
does not apply to products which are damaged during shipment back to Gems’ factory or designated service center or
are returned without the original casing on the products. Moreover, this warranty becomes immediately null and void if
anyone other than service personnel authorized by Gems attempts to repair the defective products.
Equipment sold by Gems Sensors Inc. not intended for use in a nuclear installation, nor shall it be used as a “Basic Component” as same as defi ned under Part 21, Title 10 of the Code of Federal Regulations. In the event of such use, you
agree to indemnify and hold us harmless from any and all subsequent liabilities and responsibilities which might arise in
connection with such use.
Return Policy
Returns are accepted on stock items up to 30 days from date of order.
You must contact our Returns Department for a Return Authorization (RA) number. Return the goods – freight prepaid
– in the original container and include original packing slip. C. O. D. returns are not accepted. Gems reserves the right
to apply restocking charges.
Gems further reserves the right to unilaterally waive this warranty and to dispose of any product returned to Gems
where:
a. There is evidence of a potentially hazardous material present with or on the product.
b. The product has remained unclaimed at Gems for longer than 30 days after dutifully requesting disposition of
the product from the Customer.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and liabilities of Gems under it are exclusive and instead of, and the original
purchaser hereby waives all other remedies, warranties, guarantees or liabilities, express or implied. EXCLUDED FROM
THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTICULAR PURPOSE
OR USE AND THE IMPLIED WARRANTY OF MERCHANTABILITY OF THE PRODUCTS.
Important Points:
• Gems products must be maintained and installed in strict accordance with the National Electrical Code and the
applicable Gems product instruction Bulletin that covers installation, operation and proper maintenance. Failure to
observe this information may result in serious injury or damages.
• The supply voltage to the sensor should not exceed 36 VDC, Max.
• Please adhere to the pressure and temperature limitations shown. These limitations must not be exceeded.
These pressures and temperatures take into consideration possible system surge pressures/temperatures and
their frequencies.
• Selection of materials for compatibility with the media is critical to the life and operation of Gems products. Take
care in the proper selection of materials of construction, testing is required.
• Avoid over tightening when mounting.
• Life expectancy of switch contacts varies with application. Contact Gems if life cycle testing is required.
• Ambient temperature changes do affect switch set points, since the gravity of a liquid can vary with temperature.
• Our sensors have been designed to resist shock and vibration. However, shock and vibration should be minimized.
• Electrical entries and mounting points in an enclosed tank may require liquid/vapor sealing.
• Our sensors must not be fi eld-repaired.
• Physical damage sustained by product may render it unserviceable.
This warranty may not be extended, altered or varied except by a written instrument signed by a duly-authorized offi cer
of Gems, Inc.
Thank you for purchasing Gems new innovative small tank solution. The
UCL-510 is a general purpose sensor that combines switch, controller and
transmitter capabilities for small tanks 49.2” (1.25 m) or less.
Confi guration
UCL-510 is confi gured through Confi guration, a PC software program. Confi guration is a free download from Gems website. You must download and
install Confi guration prior to plugging in the USB® Fob. Please go to http://
www.Gemssensors.com/software.
Confi guration Software
System Requirements
Windows® XP or 2000
10 mB hard drive space
256 mB RAM
1 USB® 2.0 port
Internet connection
Specifi cations
Range:
Accuracy:
Resolution:
Beam width:
Dead band:
Supply voltage:
Loop resistance:
Consumption:
Signal output:
0.5W
4-20 mA , two-wire
(when loop powered)
(4) SPST relays 1A
4 mA, 20 mA, 21 mA,
22 mA or hold last
Power loss: Hold last
Power on: Open, close
or hold last
Selectable
Software, PC Windows®
USB 2.0
Automatic over range
F: 20˚ to 140˚
C: -7˚ to 60˚
F: -31˚ to 140˚
C: -35˚ to 60˚
MWP = 30 PSI
Type 6P
encapsulated, corrosion
resistant & submersible
PC/ABS FR
Santoprene
PVDF
48” (1.2 m)
Polyurethane
1" NPT (1" G)
Viton®
General purpose
CE, cFMus
Wiring
Dimensions
RoHS
Compliant
Safety
1. Installation should be done by properly trained staff
2. Supply voltage should never exceed a maximum of 24 VDC
3. Always use stepper relays between the sensor and external loads
4. Make sure the sensor is chemically compatible with your application
5. Design a fail-safe system that accommodates the possibility of sensor and/or power failure.
6. This sensor should not be used in classifi ed hazardous environments
27
K
G
N
WHITE
Wiring UCL-510
USB® Fob Interface
After you have fi nished positioning and mounting the UCL-510, use the wiring diagram created in the confi guration software to wire the unit. Always
use an external relay in-between UCL-510 and any components. Gems
Sensors recommends using a licensed electrician to wire UCL-510 and your
application’s components. Once the UCL-510 is mounted and wired, observe
your application and double check your relay set points.
Mounting Guide
1. Do not mount at an angle
2. Liquid should never enter the 2” dead band
3. Mount at least 2” from the side wall
4. Do not mount where obstacles will intrude on 2” beam width
5. Do not mount in a vacuum
6. Never screw directly into tank, always use anon-metallic fi tting
7. Always use a tank adapter with the minimal height possible
Tank Adapter:Select a tank adapter with
minimum height to ensure that UCL-510’s
transducer will not be substantially elevated
inside the fi tting
2” x 1”, thread by thread, reducer bushing.
. Gems recommends using a
Riser: Use the riser specifi cations guide and
match your riser’s inner diameter with the
height.
Flange: Select a fl ange with a thread that is
above the plane of the fl ange. If your installation requires the use of a blind fl ange, tap
a 2” thread and use a thread by thread reducer bushing (see tank adapter).
Stand Pipe: Use a stand pipe when surface
foam or turbulence are present. Use a 2”
diameter pipe or larger with a length that
runs the distance of the span. Cut a 45º
notch at the bottom and a 1/4” hole within
2” from bottom of the transducer face.
Height
Inner Diameter
Ventilation
Hole
2" Minimum
Diameter
Riser Specifications
Inner Dia.
2" (5 cm)
3" (7.6 cm)
4" (10 cm)
6" (15 cm)
Max. Height
4” (10 cm)
6" (15 cm)
8” (20 cm)
12” (30 cm)
Dead Band
Highest
Liquid
Level
Operational Range
Lowest
Liquid
Level
UCL-510 communicates with the confi guration software through a USB® interface called a Fob. Before plugging your Fob into your computer’s USB®
2.0 port, be sure that you have installed the confi guration software on your
computer.
Connect the red, green, white and black wires from UCL-510 into the correct
terminals on the Fob. Tighten the screws on the terminals and plug your Fob
into the USB® 2.0 port of your computer.
BLAC
RED
REE
* Once the unit has been confi gured, the
White and Green wires must be isolated
from the active power to prevent a shorting
of the confi guration circuit.
Confi guration
With UCL-510 connected to your computer, open the Confi guration software. Follow steps 1-3 (pg. 4-5) to confi gure the UCL-510. Click “Help” in the
lower right hand corner and follow the help menu for further assistance.
63
Confi guration Step 1: Confi guration
Confi guration Step 3: Write to Unit
This section of Confi guration is where you select
the application’s confi guration settings. Start
from the top and work to the bottom, choosing
the selections that are applicable to your confi guration. “Not Applicable” will automatically
show when a selection doesn’t apply to your
confi guration settings, and you may move on. All
confi guration settings must be selected or have
“Not Applicable” before you can continue to
step 2.
Right click on any menu that you may have questions on to open the help menu.
Confi guration Step 2: Tank Levels
This section of Confi guration is where you enter application measurement
values. All values must be fi lled in before moving to step 3.
Sensor Height: Distance from the bottom of the tank to the bottom of the
transducer.
After you have entered confi gurations and tank values, click “Write to Unit”
and send the confi guration to UCL-510. Now use the confi guration software’s fi le management features to save your confi guration by clicking “Save
Confi g File” and print your wiring diagram by clicking “Wiring Diagram.”
Example Wiring Diagram
UCL-510
Position and Mount
Positioning and mounting UCL-510 is critical to the sensor performing correctly. UCL-510 should always be mounted perpendicular to the liquid in
the tank, clear of any obstructions in the beam path. Not doing so will result
in poor performance. Refer to Gems mounting guide on pg. 6 for further
instruction.
Fill Height: Distance from the bottom
of the tank to the maximum liquid
height.
Relay Set Points: Distance from the
bottom of the tank to set-points.
Always use correct tank adapter
(refer to Mounting
Guide on pg. 6)
Right click on any value you may have
questions on to open the help menu.
45
Always use
supplied Viton®
Gasket
Always mount
perpendicular to
the liquid in the
tank and clear of
any obstructions
in the beam path.