Gems Sensors & Controls SUBMINIATURE Part Numbering Designation

PRESSURE SWITCHES
How To Order
Use the Bold characters from the chart below to construct a product code. Please reference Notes.
PS62 -10 -4MNZ -A -SP -XX -XXXX
1 2 3 4 5 6
SUBMINIATURE
1 Pressure Range Code
Insert Pressure Range Code from Table 1, below.
2 Pressure Fitting
12L14 Zinc-Plated Steel
-2MNZ = 1/8˝ NPTM 12L14
-4MNZ = 1/4˝ NPTM 12L14
-2MGZ = 1/8˝ BSPM 12L14 (G type)
-4MGZ = 1/4˝ BSPM 12L14 (G type)
-4MSZ = 7/16˝-20 SAE Male
-6MSZ = 9/16˝-18 SAE Male
-M10Z = M10 x 1.0, Straight
-M14Z = M14 x 1.5, Straight
316L Stainless Steel
-2MNS = 1/8˝ NPTM
-4MNS = 1/4˝ NPTM
-2MGS = 1/8˝ BSPM (G type)
-4MGS = 1/4˝ BSPM (G type)
-4MSS = 7/16˝-20 SAE Male
-6MSS = 9/16˝-18 SAE Male
3 Circuit
-A = SPST/N.O.
-B = SPST/N.C.
4 Electrical Termination
-SP = Spade Terminals (standard)
-TS = Terminal Screws
-FLXX = Flying Leads
-FLSXX = Flying Leads w/PVC Shrink Tubing
-CABXX = 18 AWG PVC Cable
5 Options
-G = Gold Contacts (for loads less than 12 mA @ 12 VDC)
-IP = Ingress Protection
-IPA = Removable Silicone Seal for Set Point Adjustment
4
-R = Restrictor (low damping coefficient) Brass
-SR = Spiral Restrictor (high damping coefficient) 12L14 Steel w/Black Oxide Finish
-OF = Oil Free Cleaned (requires SS housing)
-RB = Rubber Boot (shipped loose)
-WF = Weather Pack Connector, Female
-WM = Weather Pack Connector, Male
-DE = Deutsch Connector, Male, DT04 Series
6 Fixed Set Point (optional)
A. Specify set point -FS (in PSI or BAR, see example)
Notes:
1. Other fittings available. Consult factory.
2. 18˝ is standard. Specify lead length in inches (max. 48˝). e.g. -FL18 or -FLS30.
3. 36˝ is minimum. Specify cable length in inches. e.g.
-CAB36 or -CAB120.
4. Ingress Protection is available only with -FL, -FLS or -CAB Electrical Termination choices.
5. IPA protection is available only with -FL or -FLS.
6. -SR will result in wider deadbands and lower response time.
7. Set Point must be within Pressure Range selected in Step 1.
B. Set Point Actuation R on Rising Pressure F on Falling Pressure Example: -FS3BARF for 3 BAR Falling or -FS60PSIR for 60 PSI Rising
Table 1 — Pressure Range Codes
Pressure Range Code Pressure Range Accuracy* Average Deadband**
10 15-60 psi (1-4 bar) ±1.5 psi (0.10 bar) +4% of setting 3 psi (0.21 bar) +6% of setting
20 40-150 psi (3-10 bar) ±2.5 psi (0.17 bar) +4% of setting 5 psig (0.34 bar) +7% of setting
30 75-275 psi (5.2-18.9 bar) ±3.75 psi (0.26 bar) +4% of setting 7 psig (0.48 bar) +9% of setting
40 150-600 psi (10.3-41.4 bar) ±5 psi (0.34 bar) +4% of setting 10 psi (0.69 bar) +11% of setting
* Accuracy and set point of units may change due to the effects of temperature. ** In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details.