How To Order
Use the Bold characters from the chart below to construct a product code. Please reference Notes.
PS76 -10 -4MNZ -C -H -XX -XXXX
1 2 3 4 5 6
MINIATURE
1 Pressure Range Code
Insert Pressure Range Code from Table 1, below.
2 Pressure Fitting
1
12L14 Zinc-Plated Steel
-2MNZ = 1/8˝ NPTM
-4MNZ = 1/4˝ NPTM
-4FNZ = 1/4˝ NPTF
-4MGZ = 1/4˝ BSPM (G type)
-4FGZ = 1/4˝ BSPF (G type)
-4MSZ = 7/16˝-20 SAE Male
-6MSZ = 9/16˝-18 SAE Male
-4SSZ = 7/16˝-20 SAE Male Swivel
316L Stainless Steel
-4MNS = 1/4˝ NPTM
-4MGS = 1/4˝ BSPM (G type)
-4FGS = 1/4˝ BSPF (G type)
-6MSS = 9/16˝-18 SAE Male
3 Circuit
-A = SPST/N.O.
-B = SPST/N.C.
-C = SPDT
4 Electrical Termination
-FLXX = Flying Leads
2
-FLSXX = Flying Leads w/PVC Shrink Tubing2
-ELXX = 1/2˝ NPT Male Conduit w/Flying Leads
-H = DIN 43650A Male Half Only4
-HR = Right Angle DIN 43650A Male Half Only
-HC = DIN 43650A 9mm Cable Clamp
-HCR = Right Angle DIN 43650A 9mm Cable
Clamp
4
4
-HN = DIN 43650A with 1/2˝ Female NPT Conduit
-HNR = Right Angle DIN 43650A with 1/2˝ Female
NPT Conduit
4
5 Options
-G = Gold Contacts
(for loads less than 12 mA @ 12 VDC)
-RD = Reduced Differential
(25% reduction typical)
-OF = Oil Free Cleaned
5
-R = Restrictor (low damping coefficient) Brass
-SR = Spiral Restrictor (high damping coefficient)
300 Series Stainless Steel
6
-WF = Weather Pack Connector, Female
3
4
Notes:
1. Manifold mounts available.
Consult factory.
2. 18˝ is standard. Specify lead
length in inches (max. 48˝).
e.g. -FL18 or -FL30.
3. 18˝ is standard. Specify
lead length in inches (max.
48˝). e.g. -EL18 or -EL30.
4. DIN connectors require -C
SPDT circuit.
5. Requires stainless steel
4
pressure fitting.
6. -SR will result in wider
deadbands and slower
response times.
7. Set Point must be within
Pressure Range selected in
Step 1.
-WM = Weather Pack Connector, Male
-DE = Deutsch Connector, Male, DT04 Series
6 Fixed Set Point (optional)
A. Specify set point -FS
(in PSI or BAR, see example)
7
B. Set Point Actuation
R on Rising Pressure
F on Falling Pressure
Example: -FS1BARF for 1 BAR Falling
Table 1 — Pressure Range Codes
or -FS20PSIR for 20 PSI Rising
For Circuit Codes -A, -B and -C
Pressure Range Code Pressure Range Accuracy* Average Deadband**
10 15-75 psi (1.0-5.2 bar) ±2.5 psi (0.17 bar) +3% of setting 5 psig (0.34 bar) +11% of setting
20 50-150 psi (3.5-10.3 bar) ±6 psi (0.41 bar) +3% of setting 15 psig (1.03 bar) +14% of setting
30 150-650 psi (10.3-44.8 bar) ±15 psi (1.03 bar) +3% of setting 25 psi (1.72 bar) +15% of setting
40 500-1750 psi (34.5-121 bar) ±25 psi (1.72 bar) +3% of setting 55 psi (3.79 bar) +16% of setting
* Accuracy and set point of units may change due to the effects of temperature.
** In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details.