Gems Sensors & Controls M Specifications

SOLENOID VALVES
M Series – Subminiature
MOPD: 100 PSI (6.9 Bar) CV Range: 0.018 to 0.070 (KV Range: 0.017 to 0.032)  As Low As 0.5 Watts
The M Series implements efficient power conservation in a solenoid valve that is specifically designed for sub-miniature two- and three-way pneumatic and select liquid applications. Field proven to exceed performance requirements in battery-powered applications, the M Series can be designed for extreme low wattage conditions. With a compact size, consistent high-speed response time, and reliable operation over 200 million cycles, the M Series delivers extended performance and precision flow control in a small lightweight environment.
Typical Applications
Ideal for inline PC interfacing and manifold assemblies:
• Medical and Therapeutic Healthcare
• Clinical Chemistry and Analysis Equipment
• Drop-on-Demand Printing
• Environmental Instrumentation
Dimensions
Threaded Port Body Manifold Mount Body
0.610 (15.5)
0.305 (7.7)
0.245 (6.2)
0.270 (6.8)
0.500 (12.7)
STOP PORT (2-WAY N.O. & 3-WAY)
0.863 (21.9)
Ø0.125 (3.2) THRU MOUNTING
0.733
HOLES
(18.6)
0.125 (UNDERSEAT)
(3.2)
0.312 (7.92)
0.305
0.250 (6.35)
(4) PLC’S
VOLTAGE
APPLIED TO
TOP TERMINALS
(OVERSEAT)
0.281 (7.14)
0.265 (6.7)
0.392 (9.9)
0.196 (4.9)
(7.8)
How To Order
Use the Bold characters from the choices listed on the following page to construct a product code.
0.675 (17.1)
1.78
(45.2)
(2-WAY N.C.)
0.62
(15.7)
0.500 (12.7)
2.02
(51.3)
1.76
(44.7)
1.51
(38.3)
(2-WAY N.C.)
0.20 (5.1)
#10-32 UNF-2A
MOUNTING STUD
(UNDERSEAT)
O-RINGS
Ø0.73 (18.5)
Ø0.125 (3.2) SPANNER HOLE, (3) PLC’S EQUALLY SPACED
0.15 (3.8)
32 RMS OVER
Ø0.75 (19.0)
(OVERSEAT)
MANIFOLD
MATING DIMENSIONS
#10-32 UNF-2B x
0.25 MIN. FULL TH’D
(UNDERSEAT)
R.220
(OVERSEAT) Ø0.089 (2.6)
MB 31 5 - E B 3 3 - P 201 - OC
1
Primary
Prefix
Note: After the Primary Prefix, any "-Code" may be blank when
standard (blank) selections are specified.
Example:
MB315-EB33-P-201
1 Watt 3-Way N.C. solenoid valve with a 0.052˝ (1.321mm) orifice, EPDM plunger seal/o­ring, brass body, 1/8˝ barb body and stop port, P.C. board mount (4-pin), operating at 5 VDC, and is cleaned for oxygen use.
J-5
2
Valve
Type
3
Orifice
Size
4
Plunger
Seal/O-Ring
Material
5
Body
Material
7
Stop Port
Configuration
6
Body Port
Configuration
Visit www.GemsSensors.com for most current information.
8
Coil
Construction
9
Voltage
10
Additional
Options
M Series / p1of2 / 19-SEP-17
GENERAL PURPOSE
Part Prefix Table
Power Rating
0.5 Watt
1 Watt
2 Watts
1
Orifice MOPD
C
K
V
inches mm psi bar Body
0.031 0.787 25 1.7 0.018 0.015
0.052 1.321 10 0.7 0.037 0.032
0.031 0.787 50 3.4 0.018 0.015
0.052 1.321 25 1.7 0.037 0.032
0.031 0.787 100 6.9 0.018 0.015
0.052 1.321 50 3.4 0.037 0.032
V
2 Valve Type
20 = 2-Way normally closed 22 = 2-Way normally open 30 = 3-Way normally closed (free vent) 31 = 3-Way normally closed (line connection) 32 = 3-Way normally open 33 = 3-Way multi-purpose 34 = 3-Way directional control
3 Orifice Size 2 = 0.031˝ (0.79mm) 5 = 0.052˝ (1.32mm)
4 Plunger Seal / O-Ring Material V = Viton® N = Nitrile E = EPDM
5 Body Material B = Brass A = Aluminum
6 Body Port Configuration1
0 = Face mount 1 = 1/16˝ (1.6mm) barb 2 = 5/64˝ (2.0mm) or 3/32˝ (2.4mm) barb 3 = 1/8˝ (3.2mm) barb 4 = Manifold mount, #10-32 UNF-2A stud 5 = #10-32 UNF-2B female thread (180° apart only) 6 = 1/8˝-27 NPT ports (180° apart only)
1 Primary
Prefix
MA MA MB MB MC MC
7 Stop Port Configuration1
0 = No barb (Standard for 2-way NC & 3-way free vent)
2 3
1 = 1/16˝ (1.6mm) barb (.031˝ orifice only) 2 = 5/64˝ (2.0mm) or 3/32˝ (2.4mm) barb 3 = 1/8˝ (3.2mm) barb
8 Coil Construction (Tape-Wrapped, 130°C Class B) U = P.C. board solderable (2-pin) P = P.C. board mount (4-pin)4 Q = Quick connect 0.110˝ (2.79mm) spade L = Lead-wires, #26 AWG, 18˝ (45.7cm) long W__ = Lead-wires (Specify length in inches)
9 Voltage 200 = 3 VDC 201 = 5 VDC 203 = 12 VDC 204 = 24 VDC ___VDC = DC (specify voltage) ___VAC = AC Rectified 2-watt coil only (specify voltage, lead-wires only)
10 Additional Options OC = Cleaned for oxygen use VAC = Vacuum application – 0 to 27˝ Hg (0 to 914 mBar)
Notes
1. Barbs are brass.
2. For Stop Port Configuration, must select "0" for valve type 20 (2-way NC) and for type 30 (3-way NC Free Vent).
3. For Stop Port Configuration, must select "1" or "2" or "3" for valve types 22 (2-way NO), 31 (3-way NC Line Connect), 32 (3-way NO), 33 (3-way MP), and 34 (3-way DC). Selection "0" can not be used.
4. 2 pins near stop are active.
† Teflon® o-ring not suitable for manifold mount.
Gems specializes in the design and manufacturing of custom solenoid valves and fluidic systems. If you don’t see what you’re looking for, or have a question, contact us at 800-378-1600 or info@gemssensors.com.
Flow Schematic
3-WAY NORMALLY CLOSED 3-WAY NORMALLY OPEN2-WAY NORMALLY CLOSED 2-WAY NORMALLY OPEN
IN IN
OUT
IN
DE-ENERGIZED ENERGIZED DE-ENERGIZED ENERGIZED DE-ENERGIZED ENERGIZED DE-ENERGIZED ENERGIZED
N.O.
COM
N.C.
ENERGIZED
OUT OUT OUT
IN
3-WAY MULTI-PURPOSE
N.O. N.O.
AND
COM
N.C.
COM
N.C.
N.O. N.O. N.O.
COM
N.C.
EXH EXH
CYL
IN
3-WAY DIRECTIONAL CONTROL
IN
N.C.
DE-ENERGIZED ENERGIZEDDE-ENERGIZED ENERGIZEDDE-ENERGIZED
CYL CYL CYL
IN
IN
N.C.
IN IN
EXH EXH
Flow Key
Blocked Flow
Free Flow
SOLENOID VALVES
M Series / p2of2 / 19-SEP-17
Visit www.GemsSensors.com for most current information.
J-6