Gems Sensors & Controls FS-200 Specifications

FLOW SWITCHES
UL Approved
Explosion-Proof
A
B
1/2" -NPT
BONNET
SWITCH HOUSING
NPT PORT
INLET PORT
C
#18 AWG., 24" L.,
POLYMERIC JACKET
G-4 ill
FS-200 Series – General Purpose, Straight-Through Flow Path
Flow Rate Settings: Fixed: 0.5 GPM to 100.0 GPM Adjustable: 1.0 GPM to 15.0 GPM
Port Size: 1˝ NPT to 2˝ NPT
Primary Construction Material: Bronze or Stainless Steel
Setting Type: Fixed or Adjustable
The FS-200 Series offers accurate flow detection, with 1% repeatability, over a broad range of flow settings and port sizes. Its durable construction delivers long-life reliability in either water or oil. Generous flow paths keep pressure drop low. These switches are ideal for detection of improper flow rates in high volume lubrication, cooling or process systems.
FS-200 Adjustable Series switches offer the same accuracy and are as rugged as those with fixed settings, but provide one additional feature: external adjustability. With these versatile switches your choice of flow settings is diverse within a given range. An ordinary, flat-blade screwdriver is all that’s required for the actuation adjustment.
Specifications
Wetted Materials Housing
FS-200 Bronze or 316 Stainless Steel
FS-200 Adjustable Bronze
Shuttle Teflon
Bonnet Bronze or Stainless Steel
Spring 316 Stainless Steel
Other Wetted Parts Viton®, Ceramic
Pressure Rating Operating 400 PSIG (27.6 bar) @ 100°F (37.8°C)
Proof 800 PSIG (55.2 bar) @ 100°F (37.8°C)
Operating Temperature FS-200 -20°F to +300°F (-29°C to +148.9°C)
FS-200 Adjustable -20°F to +200°F (-29°C to +93.3°C)
Repeatability 1% Maximum Deviation
Set Point Accuracy ±10%
Set Point Differential 15% Maximum
Switch* SPDT, 20 VA
Electrical Termination No. 18 AWG, 24˝ L., Polymeric Lead Wires
Red NC, Black Common, Orange NO
*See “Electrical Data” on Page X-5 for more information.
®
FS-200 Series
U.L. Recognized File No. E31926 CSA Listed — File No. LR30200 and LR22666 FM Approved — File No. 0A8A3.AE and 1H3A2.AX
FS-200 Adjustable
U.L. Recognized File No. E31926 CSA Listed — File No. LR22666 FM Approved — File No. 0Q2A8.AE
Dimensions
Model
FS-200
FS-200
Adjustable
Notes:
1. Adjustable versions available in 1 inch port sizes only.
2. Standard calibration is in water with units in a horizontal position.
3. Viscosity changes will affect setpoints. Typically, as viscosity increases setpoints will decrease.
4. Consult Gems for special applications.
Port Size
NPTAinch (mm)Binch (mm)
3-1/4 (82.6) 3 (76.2) 1-25/32 (45.2)
and
1-1/4˝ 4 (101.6) 3-3/16 (80.9) 2-3/16 (55.5)
1-1/4˝ ss 4-1/2 (114.3) 3-3/16 (80.9) 2-3/16 (55.5)
1-1/2˝ 4-1/2 (114.3) 3-1/2 (88.9) 2-1/2 (63.5)
5-3/8 (136.5) 4 (101.6) 3-3/32 (78.5)
inch (mm)
G-18
Visit www.GemsSensors.com for most current information.
SHUTTLE TYPE
4
3
2
0
1
0 5 10 15 20 25 30 35 40
FLOW RATE - GPM
PRESSURE DROP (PSID)
1.5
1.0
0.5
0
0 10 20 30 40 50 60 70 80
2.0
FLOW RATE - GPM
Tests conducted with units in horizontal position (lead wires up) with water at +70°F (21°C).
PRESSURE DROP (PSID)
Part No. 27101
Part No. 27085
Part No. 27051
How To Order – Standard Models
Specify Part Number for the FS-200 Series based on desired housing material, port size and flow setting, or based on flow setting range for FS-200 Adjustable versions.
FS-200 Series
Port Size
NPT
1”
1-1/4”
Flow
Setting
GPM
0.5
1
2
3
4
5
6
8
1
2
4
6
8
10
12
16
20
Part Numbers
Bronze
Stainless
Steel
27051 27059
27052 27060
27053 27061
27054 27062
27055 27063
27056 27064
27057 27065
27058 27066
27067 27076
27068 27077
27069 27078
27070 27079
27071 27080
27072 27081
27073 27082
27074 27083
27075 27084
Port Size
NPT
1-1.2”
2”
Flow
Setting
GPM
1.5
3
5
7.5
10
15
20
30
2
4
5
10
15
25
35
50
Part Numbers
Bronze
Stainless
Steel
27085 27093
27086 27094
27087 27095
27088 27096
27089 27097
27090 27098
27091 27099
27092 27100
27101 27109
27102 27110
27103 27111
27104 27112
27105 27113
27106 27114
27107 27115
27108 27116
Pressure Drop - Typical
1˝ NPT and 1-1/2˝ NPT Ports
2˝ NPT Ports
FS-200 Adjustable
Port Size NPT Flow Setting Adjustment Range GPM Part Numbers
Notes:
1. Flow settings for fixed versions are calibrated using water at +70°F on increasing flow, with units in a horizontal position (lead wires up). Consult factory regarding special flow setting calibration, or liquids other than water. Temperature changes will slightly affect the flow settings listed. Oil flow settings will vary with viscosity.
2. Adjustable units that are set to customer specification are subject to GEMS test stand accuracy.
3. Use of 150 micron filtration is recommended.
4. Minimum 5 PSI line pressure required.
– Stock Items.
1”
1.0-6.0
5.0-15.0
2.0-8.0
26615
26616
26838
FS-200 Series Flow Switches are U.L. Approved for Class I, Division 2, Groups A, B, C, D hazardous areas.
They are also available with FM-approved, explosion-proof junction box for Class I, Division 1, Group D hazardous locations. Units must be completely assembled at GEMS.
U.L. Approved — File No. E183854
For Remote Alarms – See Page E-30
• Adjustable Volume
• Indoor Outdoor
• Solid-State
FLOW SWITCHES
Visit www.GemsSensors.com for most current information.
G-19