Gems Sensors & Controls 19MR Operating Manual

Form 229Form 229
Form 229
Form 229Form 229
Sheet P/N 100346-1Sheet P/N 100346-1
Sheet P/N 100346-1
Sheet P/N 100346-1Sheet P/N 100346-1
RevRev
. B. B
Rev
. B
RevRev
®®
®
WW
arrickarrick
W
arrick
WW
arrickarrick
Installation and Operation BulletinInstallation and Operation Bulletin
Installation and Operation Bulletin
Installation and Operation BulletinInstallation and Operation Bulletin
®®
Series 19MR Controls Series 19MR Controls
Series 19MR Controls
Series 19MR Controls Series 19MR Controls
. B. B
This bulletin should be used by exper ienced personnel as a guide to the installation of series 19MR controls. Selection or installation of equipment should always be accompanied by competent technical assistance. We encourage you to contact Gems Sensors or its local representative if fur ther information is required.
Installation
1. Install the control in an appropiate enclosure using two size six screws.
2. Wire control per diagram, following N.E.C. and local codes. Use appropriately sized spade terminals. For 120 VAC operation, wire the “Com/L2 to the spade lug marked “COM/L2”. Wire the 120 VAC wire to the “120V” spade lug.
3. For 240 VAC operation, wire the “C“ Com/L2 to the spade lug marked “COM/L2”. Wire the 240 VAC wire to the “240V” spade lug.
4. Wire the load per diagram on reverse of this page. Be sure the load is wired to the proper terminal: 120V loads wired to the “120V” ter minal and COM, 240 V loads wired to “240” ter minal and COM.
Series 19MR performs pump-up motor control for carbonators. When the liquid level in the carbonator
falls below the low probe, Series 19MR tur ns on the motor to pump up the liquid. The control eliminates the need for contactors because it can handle the motor load directly. Series 19MR provides level control in applications for which pump-up or pump-down service is necessary, or where the motor load must be handled directly. Consult factor y for recommendations for
your system.
Specifications
Control Design: Open Circuit Board Contact Design: SPST: One Normally Open (N.O.) Powered Contact Contact Ratings: 30 Amp @ 240 VAC, Resistive Contact Life: Mechanical- 10,000,000 Operations
Electrical- 250,000 Operations Minimum at Rated Load
Supply V oltage: 120, or 240 VAC +10% -15% 50/60 Hz Supply Current: Relay Energized at 4.4 VA Secondary Circuit: 11 VAC RMS Voltage on Probes. 1.5 milli-amp Current. Sensitivity: Models Operate from 4.7K to 100K Maximum Specific Resistance Temperature: 0° to 150°F Ambient Terminals: Probe Connections 3/16” Spade: Line and Power Connections ¼” Space Listings: U.L.508 Industrial Motor Controllers Status Indicator: LED Indication for Pump Off. LED Off When Pump is On.
4 IN
3-1/2 IN
1-7/16 IN
2-7/8 IN
KEYHOLE & SLOT FOR TWO SIZE 6 MOUNTING SCREWS
1-1/2 IN
Operation of Series 19MR Controls
Differential Service
Inverse Mode, Pump-Up: When the liquid rises to the high electrode (“H” probe), the control de-energizes
the relay. The pump turns off and the LED is off. The control remains de-energized until the liquid recedes below the long probe (“L” probe). Direct Mode: Pump-Down: When the liquid r ises to the high electrode (“H” probe), the control energizes the relay. The pump turns on and the LED is on. The control remains energized unti the liquid recedes below the long probe (“L” probe).
Single Level Service
Place jumper between the “H” and the “L” ter minals. Use terminals “G” and “H” for the probe connnections.
G
H
L
COM/L2
120V
COM/L2 120V 240V
240V
120 VAC
19MR X - X19MR X - X
19MR X - X
19MR X - X19MR X - X
Motor
Enclosure Option
00
0- None,
00
Mode of Operation
AA
A- Direct Mode; 11,000 ohms
AA BB
B- Direct Mode: 19,000 ohms
BB CC
C- Inverse Mode: 11,000 ohms
CC DD
D- Inverse Mode: 19,000 ohms
DD
1 1
1- NEMA 1,
1 1
44
4- NEMA 4
44
G
H
L
COM/L2
120V
COM/L2 120V 240V
240V
240 VAC
Motor
Gems Sensors Inc. One Cowles Road Plainville, CT 06062-1198 Tel: 860-793-4579 Fax: 860-793-4580