1200 Series / 1600 Series –
OEM Transducers Featuring Exceptional
Proof Pressure and Stability Specifications
Gauge, Vacuum, and Compound Pressure Models
General Purpose and Wash down Enclosures
High Proof Pressure Achieved by Thicker Diaphragm Construction
Voltage and Current Output Models
The 1200 Series features stability and toughness via its CVD and ASIC design coupled
with a thicker diaphragm. The thicker diaphragm enables these sensors to survive
most pressure spikes caused by pump ripple, solenoid valves, etc. The 1600 Series
extends the packaging options by providing an all welded stainless steel back end
for demanding industrial applications. A modular design allows special ordering of
fittings, electrical cables, etc. for OEM applications. The ASIC and CVD technology
enables Gems to offer almost any output over any pressure range.
PSIBAR® CVD TYPES
Specifications
Input
Pressure Range Vacuum to 6000 psi (400 bar)
Proof Pressure 4 x Full Scale (FS) (<1% FS Zero Shift)
Burst Pressure >35 x FS <= 60 psi (4 bar);
>20 x FS <= 600 psi (40 bar);
>5 x FS <= 6000 psi (400 bar)
Fatigue Life Designed for more than 100 million FS cycles
Performance
Supply Voltage Sensitivity 0.01% FS/Volt
Long Term Drift 0.2% FS/year (non-cumulative)
Accuracy 0.5% FS typical
Thermal Error 2.0% FS typical
Compensated Temperatures -5°F to +180°F (-20°C to +80°C)
Operating Temperatures -40°F to +260°F (-40°C to +125°C) for elec. codes A, B, C, 1
-5°F to +180°F (-20°C to +80°C) for elec. codes 2, D, G, 3
-5°F to +125°F (-20°C to +50°C) for elec. code F
temperatures >100°C supply is limited to 24 VDC
Zero Tolerance 1% of span
Span Tolerance 1% of span
Response Time 0.5 ms
Mechanical Configuration
Pressure Port see ordering chart
Wetted Parts 17-4 PH Stainless Steel
Electrical Connection see ordering chart
Enclosure 316 SS, 17-4 PH ss
IP65 NEMA 4 for elec. codes A,B,C,D,G,1,2,3
IP67 for elec. codes F
IP30 for elec. code “3” with flying leads
Vibration 70g, peak to peak sinusoidal, 5 to 2000 Hz
(Random Vibration: 20 to 200 Hz @ 20g Peak
per MIL-STD.-810E Method 514.4)
Acceleration 100g steady acceleration in any direction 0.032% FS/g
for 15 psi (1 bar) range decreasing logarithmically
to 0.0007% FS/g for 6000 psi (400 bar) range.
Shock 20g, 11 ms, per MIL-STD.-810E Method 516.4 Procedure I
Approvals CE, UR (12 ET, 16 ET Intrinsically safe)
Weight approx. 100 grams (additional; cable 75 g/m)
Along with the superiority of the CVD strain gauge,
®
Psibar
transducers incorporate components to
leverage the sensing element’s strength. The output is
a product with a unique balance of performance and
value unmatched in today’s pressure sensing market.
Thicker diaphragm for handling
pulsating pressures –
all stainless steel wetted parts.
CVD sensor stability and high
sensitivity allows use of our
thicker diaphragm. 17-4 PH SS
sensor beam is laser welded for
distortion-free construction.
Weldless
stainless steel
case.
ASIC chip is the brains
behind the brawn.
Programmability provides
greater linearity correction
than common thermal
compensation methods.
RFI/EMI & ESD protection circuit
meets and exceeds requirements for
CE marking. Protecting against noise,
voltage spikes and static discharge.
1200/1600 Series / p1of3 / 3-APR-14
H-25