![](/html/38/3884/3884989df7792a8d1dde8c46a27b6179dfc18acebb58ceb509bc78bae2d5a479/bg2.png)
RemoDAQ-8352 模块用户手册
目录
..................................................................................................................................................2 目录
第一章 产品介绍...........................................................................................................................3
1.1 概述.....................................................................................................................................3
1.2 端子分布............................................................................................................................3
1.3 特征....................................................................................................................................4
1.3.1 简介.........................................................................................................................4
1.3.2 数字量输入.............................................................................................................4
1.3.3 数字量输出.............................................................................................................4
1.4 接线说明............................................................................................................................5
1.4.1 数字量输入接线说明..............................................................................................5
1.4.2 数字量输出接线说明..............................................................................................6
1.5 功能介绍............................................................................................................................6
1.5.1 ...........................................................................................................6 上电初始化
1.5.2 DI工作模式 ..........................................................................................................6
1.5.3 DO工作模式.........................................................................................................7
第二章 命令.....................................................................................................................................8
2.1 命令说明............................................................................................................................8
2.2 功能码 1/2 协议格式(读DIO状态及计数器控制位).......................................................9
2.3 功能码 3/4 协议格式(读计数器及寄存器)......................................................................9
2.4 功能码 5(写单路DO及计数器控制位) .....................................................................10
2.5 功能码 15(0FH)(写多路DO及计数器控制位) .........................................................10
2.6 功能码 6 (写单个寄存器)...............................................................................................10
2.7 功能码 16 (10H)( 写多个寄存器)..................................................................................11
2.8 RemoDAQ-8352 MODBUS RTU地址映像表 ................................................................12
第三章 软件说明...........................................................................................................................15
版本记录:
V1.0 2009-07-17 版本创建
V1.1 2009-12-31 DO 输出类型改为源型输出
第 2 页 共 18 页
![](/html/38/3884/3884989df7792a8d1dde8c46a27b6179dfc18acebb58ceb509bc78bae2d5a479/bg3.png)
RemoDAQ-8352 模块用户手册
第一章 产品介绍
1.1 概述
RemoDAQ-83XX 系列模块是基于以太网的数据采集模块。它们提供了
模拟量输入、模拟量输出、数字量输入/输出、定时器/计数器和其它功能,
这些模块可以由命令远程控制。
RemoDAQ-8352 是基于以太网的 16 路隔离的源点型数字量输入输出
模块。
1.2 端子分布
图 1.1
第 3 页 共 18 页
![](/html/38/3884/3884989df7792a8d1dde8c46a27b6179dfc18acebb58ceb509bc78bae2d5a479/bg4.png)
1.3 特征
1.3.1 简介
z 支持 10/100M 以太网
z 支持 Modbus/TCP
z 输入电压:+10V~+30VDC
z 功耗:1.5W
z 温度:-20 ~70℃℃
z 湿度:5%~90%,无凝露
z 隔离:3000VDC
1.3.2 数字量输入
RemoDAQ-8352 模块用户手册
z 通道数:8
z 干结点:
逻辑 0:接地
逻辑 1:开路
z 湿结点:
逻辑 0:0 ~ 3 VDC
逻辑 1:10 ~ 30 VDC
z 支持 3 kHz 计数器(32 位+ 1 位溢出位)
z 支持“高-低”或“低-高”锁存
z 支持 3 kHz 频率测量
1.3.3 数字量输出
z 通道数: 8
z 输出类型:源点型,10-30VDC 最大 1A(每个通道)
z 支持 5 kHz 脉冲输出
第 4 页 共 18 页
![](/html/38/3884/3884989df7792a8d1dde8c46a27b6179dfc18acebb58ceb509bc78bae2d5a479/bg5.png)
RemoDAQ-8352 模块用户手册
1.4 接线说明
1.4.1 数字量输入接线说明
图 1.2 RemoDAQ-8352 干结点数字输入
图 1.3 RemoDAQ-8352 湿结点数字输入
第 5 页 共 18 页
![](/html/38/3884/3884989df7792a8d1dde8c46a27b6179dfc18acebb58ceb509bc78bae2d5a479/bg6.png)
RemoDAQ-8352 模块用户手册
1.4.2 数字量输出接线说明
图 1.4 RemoDAQ-8352 源点型数字输出
1.5 功能介绍
1.5.1 上电初始化
上电后,模块将把 EEPROM 中的数据读出,配置相关的寄存器,如:脉宽
寄存器、脉宽计数寄存器、名字寄存器、版本寄存器、DI 模式寄存器和 DO 模
式寄存器。用户每正确配置上述寄存器,模块都会把这一次的配置信息写入
EEPROM 的对应地址中。
1.5.2 DI 工作模式
1. 普通 DI 模式(默认)
当某一 DI 通道的模式寄存器设为 00(参见 2.8 RemoDAQ-8352 MODBUS
RTU 地址映像表)时,该通道处于普通 DI 模式工作模式。在这一模式下,该通
道仅仅采集当前的 DI 状态。
2. 计数器模式
当某一 DI 通道的模式寄存器设为 01(参见 2.8 RemoDAQ-8352 MODBUS
RTU 地址映像表)时,该通道处于计数器模式。处于这一模式后,当设置“计
第 6 页 共 18 页