ZIDI240WII
34-1/2"-35"
24" Min.
23-3/4"
34-1/2"
23-3/4" Stainless Steel
Models
24-7/8" Framed Models
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
Depth Including
Handle:
26" Stainless Steel
Models Only
23-3/4" Min.
Note: If installing between frameless
cabinets, a 1/2" wide filler strip or side panel
may be required. The filler strip will act as a
spacer between the door case and adjacent cabinet
and will prevent interference with cabinet door swing.
The width of the opening must include filler panels.
34-1/2" - 35"
24" Min.
47-1/2" Min.
1-1/2"
Locate Outlets
9"
Max.
10-1/2"
1-1/2"
9"
Max.
10-1/2"
24"
GE Monogram® Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Installation Information (in inches)
Installation Space
For a complete food storage center, install two Monogram
refrigeration modules side-by-side.
Note: Reversible door swing on wine chillers/reserves and
beverage centers only. See below for combination cutout
dimensions.
Important Note: Products must operate from separate,
properly grounded receptacles.
The cutout depth must be 24"
• Both models can be installed flush with stardard cabinetry.
• Designed to be built-in only. Cannot be used free-standing.
• White case and drawer sides, black vented toekick with
optional stainless steel toekick supplied.
Additional Specifications:
• A 120 volt 60Hz., 15 or 20 amp power supply is required. An
individual property grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3prong electrical receptacle recessed into the back wall as
shown. Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Note: Additional cutout width may be required for
models with custom panels.
Specification Created 12/07
Listed by
Underwriters
Laboratories
120032
ZIDI240WII
Overlay
Panel
1/4"
Backer
Panel
Door
.10 Inch
Spacer
Spacer Panel
Backer Panel
Overlay Panel
B
A
1/4" Gap
12-1/2 lbs. max.
B
12-1/2 lbs. max.
GE Monogram® Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240WSS
GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Installation Information (in inches)
Grounding the Double-Drawer Refrigerator
IMPORTANT - (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong
(grounding) wall receptacle to minimize the possibility of
electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is
your personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall
outlet.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO
CONNECT THE REFRIGERATOR TO A 2PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
3/4” Overlay Panel Dimensions
Model ZIDI240WII requires customerprovided overlay door panel.
• The overlay panel must be secured to a
1/4" thick backer panel which slides into
the trim. A .10" thick spacer panel must
be placed between the custom and
backer panel.
• A custom handle of your choice,
supplied by your cabinet maker, must be
installed on the overlay panel.
3/4" Overlay Panel Dimensions (in inches)
A (Width) B (Height)
1/4" Backer 23-3/16" 14-11/16"
0.10" Spacer 22-1/2" 14-3/16"
3/4" Overlay 23-5/8" 15-1/16"
NOTE: Max. assembled drawer panel
weight is 25 lbs.
IMPORTANT: Maintain a 1/4" gap
between the panels when installed.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 7/05
120032
Assemble overlay panels with glue
and screws.
• Center spacer panel on the backer
panel, left to right and top to
bottom. Secure the panels with glue.
• Center the spacer/backer panel on
the overlay panel. Secure with glue
and screws. Countersink screws into
the backer panel.
Specification Created 12/07
Listed by
Underwriters
Laboratories
120032