JVM1540LNCS
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-13/32
(rear)
105°
Door open
15-1/4
24-1/2
16
29-7/8
Minimum distance from
door hinge side to adjacent
wall should equal 1/2-inch.
(without
obstruction)
13"
MAX.
12"
MIN.
Dimensions (in inches)
Over-the-Range Microwave Oven
GE Spacemaker® 1.5 Cu. Ft. Capacity Over-the-Range Microwave
Dimensions and Installation Information (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must
be located in cabinet above Spacemaker microwave oven.
No additional wiring, venting or cabinet rebuilding necessary
in many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed with
the Spacemaker microwave oven.
Important Information: When installing the Spacemaker
microwave oven over a range, allow minimum of 2" from bottom
of Spacemaker microwave oven to top of range backguard to
allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens are
designed for adaptation to the following three types of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information: This information is not intended to
be used for installing unit described. Before installing, consult
installation instructions packed with product/kit for current
dimensional data.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Created 6/08
Listed by
Underwriters
Laboratories
340199
JVM1540LNCS
GE Spacemaker® 1.5 Cu. Ft. Capacity Over-the-Range Microwave
Optional Accessories (Available at additional cost)
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Duct: The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6” diameter duct
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance
to airflow and are equivalent to a section of straight duct which is longer than their
actual physical size. When calculating the total duct length, add the equivalent length of
all transitions and adaptors plus the lengths of all straight duct sections. The chart below
shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent Feet
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft .
Filler Panel kits
JX41
When replacing a 36"
range hood, this kit fills
in the additional width
to provide a custom
built-in appearance. For
installation between
cabinets only; not for
end-of-cabinet
installation. Each
kit contains two
3"-wide filler panels.
Filter kits JX81A–
Recirculating
Charcoal Filter kit
To be used when
the Spacemaker
microwave oven
cannot be vented
to the outside.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.