GE Medical Systems LOGIQ ?200 Service Manual

 #"!

$! 

α
 $ #
       
 " #""
DAMAGE IN TRANSPORTATION
All packages should be closely examined at time of delivery. If damage is apparent, write “damage in shipment” on all copies of the freight or express bill before delivery is accepted or “signed for” by a General Electric representative or hospital receiving agent. Whether noted or concealed, damage MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after receipt, and the contents and containers held for inspection by the carrier. A transportation company will not pay a claim for damage if the inspection is not requested within this 14 day period.
GE Medical Systems – Americas
USA: (1) 800–437–1171 Canada: (1) 800–668–0732 Latin & South Am: (1) 305–735–2304
GE Medical Systems – Asia
Japan: (81) 426–48–2594 Korea (82)342–40–6000
GE Medical Systems – Europe
Germany (49) 212–2802–165
R & D Support Group Of SGMS
FAX Number: 82–342–420–420
2184997
REV. 0
SAMSUNG GE MEDICAL SYSTEMS, LTD. SERVICE TEAM
64–3, Sangdaewon–dong, Chungwon–ku, Sungnam–si Kyunggido, KOREA
Stick along this line
(DO NOT TEAR) FOLD HERE AND SEAL (DO NOT TEAR)
REPORT ON TECHNICAL PUBLICATION – RT
(OMISSIONS,ERRORS,SUGGESTIONS)
PRODUCT PUBLICATION # PAGE # PAGE REV DATA REPOR TED SERVICE RECORD SUBMITTED YES NO PLEASE BE SPECIFIC IN YOUR CORRECTIONS AND SUGGESTIONS
FOLD FOLD
IF ADDITIONAL P AGES ARE INCLUDED, FOLD AND STAPLE TO LOWER PART OF THIS SHEET BEFORE MAILING.
SERVICE REP
PHONE FAX COUNTRY CITY
2184996
REV0
GE MEDICAL SYSTEMS
WARNING
AVERTISSEMENT
THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY.IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE OTHER
THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE TRANSLATION SERVICES.
DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS SERVICE
MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD.
F AILURE TO HEED THIS W ARNING MAY RESULT IN INJURY TO THE SER VICE
PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC SHOCK, MECHANICAL OR OTHER HAZARDS.
CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS.SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE AUTRE
LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE DE LE FAIRE TRADUIRE.
NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT QUE LE
MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS.
LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ LE
TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES.
WARNUNG
AVISO
DIESES KUNDENDIENST–HANDBUCH EXISTIERT NUR IN
ENGLISCHER SPRACHE.
FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT,
IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE ÜBERSETZUNG ZU SORGEN.
VERSUCHEN SIE NICHT, DAS GERÄT ZU REPARIEREN, BEVOR DIESES
KUNDENDIENST–HANDBUCH NICHT ZU RATE GEZOGEN UND VERST ANDEN WURDE.
WIRD DIESE W ARNUNG NICHT BEACHTET , SO KANN ES ZU VERLETZUNGEN
DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLÄGE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
ESTE MANUAL DE SERVICIO SÓLO EXISTE EN INGLÉS.SI ALGÚN PROVEEDOR DE SERVICIOS AJENO A GEMS SOLICIT A UN IDIOMA
QUE NO SEA EL INGLÉS, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCIÓN.
NO SE DEBERÁ DAR SERVICIO TÉCNICO AL EQUIPO, SIN HABER
CONSULTADO Y COMPRENDIDO ESTE MANUAL DE SERVICIO.
LA NO OBSERVANCIA DEL PRESENTE AVISO PUEDE DAR LUGAR A QUE EL
PROVEEDOR DE SERVICIOS, EL OPERADOR O EL PACIENTE SUFRAN LESIONES PROVOCADAS POR CAUSAS ELÉCTRICAS, MECÁNICAS O DE OTRA NATURALEZA.
2184998 REV. 0
GE MEDICAL SYSTEMS
ATENÇÃO
AVVERTENZA
ESTE MANUAL DE ASSISTÊNCIA TÉCNICA SÓ SE ENCONTRA
DISPONÍVEL EM INGLÊS.
SE QUALQUER OUTRO SERVIÇO DE ASSISTÊNCIA TÉCNICA, QUE NÃO A
GEMS, SOLICITAR ESTES MANUAIS NOUTRO IDIOMA, É DA RESPONSABILIDADE DO CLIENTE FORNECER OS SERVIÇOS DE TRADUÇÃO.
NÃO TENTE REPARAR O EQUIPAMENTO SEM TER CONSULTADO E
COMPREENDIDO ESTE MANUAL DE ASSISTÊNCIA TÉCNICA.
O NÃO CUMPRIMENTO DESTE AVISO PODE POR EM PERIGO A SEGURANÇA
DO TÉCNICO, OPERADOR OU PACIENTE DEVIDO A‘ CHOQUES ELÉTRICOS, MECÂNICOS OU OUTROS.
IL PRESENTE MANUALE DI MANUTENZIONE È DISPONIBILE
SOLTANTO IN INGLESE.
SE UN ADDETTO ALLA MANUTENZIONE ESTERNO ALLA GEMS RICHIEDE IL
MANUALE IN UNA LINGUA DIVERSA, IL CLIENTE È TENUTO A PROVVEDERE DIRETTAMENTE ALLA TRADUZIONE.
SI PROCEDA ALLA MANUTENZIONE DELL’APPARECCHIATURA SOLO DOPO
AVER CONSULTATO IL PRESENTE MANUALE ED AVERNE COMPRESO IL CONTENUTO.
NON TENERE CONTO DELLA PRESENTE AVVERTENZA POTREBBE FAR
COMPIERE OPERAZIONI DA CUI DERIVINO LESIONI ALL’ADDETTO ALLA MANUTENZIONE, ALL’UTILIZZATORE ED AL PAZIENTE PER FOLGORAZIONE ELETTRICA, PER URTI MECCANICI OD ALTRI RISCHI.
GE MEDICAL SYSTEMS
REV 9
LOGIQ 200 SERVICE MANUAL
2138853
LIST OF EFFECTIVE PAGES
REV DATE PRIMARY REASON FOR CHANGE
0 March 1. 1997 Inital release 1 April 1. 1997 System software version 1.0 console release 2 July 15. 1997 Error correction 3 May 7. 1998 System software version 2.0 console release 4 June 17. 1998 System software version 2.01 console release 5 April 15. 1999 FRU added & Update 6 August 1. 1999 FRU added & Update 7 January 15. 2000 FRU added & Update 8 November 14. 2000 FRU Update 9 January 14. 2001 Manufacturer Name Change
P AGE REV PAGE REV PAGE REV PAGE REV PAGE REV
Title Page 9. . . . . . . . . .
GE Logo Page 0. . . . . .
2184996 0. . . . . . . . . . .
2184997 0. . . . . . . . . . .
2184998 0. . . . . . . . . . .
A9
. . . . . . . . . . . . . . . . . .
i to vi 5. . . . . . . . . . . . . .
Chapter 1
1–1 to 1–2 2. . . . . . . . . .
1–3 to 1–7 0. . . . . . . . . .
1–8 to 1–13 9
1–14 to 1–16 0. . . . . . .
1–17 3. . . . . . . . . . . . . . .
1–18 to 1–19 0. . . . . . .
1–20 9. . . . . . . . . . . . . . .
. . . . . . . . .
Chapter 2
2–1 3. . . . . . . . . . . . . . . .
2–2 to 2–3 0. . . . . . . . . .
2–4 2. . . . . . . . . . . . . . . .
2–5 0. . . . . . . . . . . . . . . .
2–6 2. . . . . . . . . . . . . . . .
2–7 to 2–8 0. . . . . . . . . .
2–9 5. . . . . . . . . . . . . . . .
2–10 0. . . . . . . . . . . . . .
2–11 5. . . . . . . . . . . . . .
2–12 to 2–13 0. . . . . . .
2–14 to 2–15 2. . . . . . .
2–16 0. . . . . . . . . . . . . .
Chapter 3
3–1 2. . . . . . . . . . . . . . . .
3–2 to 3–3 0. . . . . . . . . .
3–4 to 3–6 3. . . . . . . . . .
3–7 2. . . . . . . . . . . . . . .
3–8 3. . . . . . . . . . . . . . .
3–9 0. . . . . . . . . . . . . . . .
3–10 3. . . . . . . . . . . . . .
3–11 2. . . . . . . . . . . . . . .
3–12 0. . . . . . . . . . . . . . .
3–13 5. . . . . . . . . . . . . . .
3–14 0. . . . . . . . . . . . . . .
Chapter 4
4–1 to 4–2 0. . . . . . . . . .
4–3 2. . . . . . . . . . . . . . . .
4–4 3. . . . . . . . . . . . . . . .
4–5 2. . . . . . . . . . . . . . . .
4–6 3. . . . . . . . . . . . . . .
4–7 to 4–10 0. . . . . . . . .
Chapter 5
5–1 to 5–3 0. . . . . . . . . .
5–4 3. . . . . . . . . . . . . . . .
5–5 to 5–8 0. . . . . . . . . .
Chapter 6
6–1 to 6–2 5. . . . . . . . . .
6–3 to 6–4 4. . . . . . . . . .
6–5 to 6–6 5. . . . . . . . . .
6–7 to 6–8 4. . . . . . . . . .
6–9 to 6–11 5. . . . . . . . .
6–12 4. . . . . . . . . . . . . . .
6–13 8. . . . . . . . . . . . . . .
6–14 4. . . . . . . . . . . . . . .
6–15 7. . . . . . . . . . . . . . .
6–16 5. . . . . . . . . . . . . . .
6–17 to 6–18 4. . . . . . .
6–19 5. . . . . . . . . . . . . . .
6–20 7. . . . . . . . . . . . . . .
6–21 to 6–42 4. . . . . . .
6–43 to 6–1 10 5. . . . . . .
Chapter 7
7–1 3. . . . . . . . . . . . . . .
7–2 to 7–3 0. . . . . . . . . .
7–4 2. . . . . . . . . . . . . . . .
7–5 to 7–14 3. . . . . . . . .
Chapter 8
8–1 to 8–4 0. . . . . . . . . .
A
GE MEDICAL SYSTEMS
REV 5
LOGIQ α200 SERVICE MANUAL
2138853
TABLE OF CONTENTS
SECTION TITLE PAGE
T ABLE OF CONTENTS i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 1 – INTRODUCTION
1–1 SERVICE MANUAL CONTENTS 1–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2 SAFETY 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2–1 Warnings 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2–2 Specifications 1–17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3 EMC (Electromagnetic Compatibility) 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–1 EMC Performance 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–2 Notice upon Installation of Product 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–3 General Notice 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–4 Countermeasures against EMC-related Issues 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–5 Notice on Service 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–4 ADDRESS 1–20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 2 – INSTALLATION
2–1 PREINSTALLATION 2–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–1–1 Introduction 2–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–1–2 Power Line Requirements 2–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–1–3 Physical Specifications 2–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–1–4 Recommended Ultrasound Room Layout 2–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2 INST ALLA TION 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–1 Introduction 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–2 Average Installation Time 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–3 Installation Warnings 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–4 Checking the Components 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
i
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 5
SECTION TITLE PAGE
LOGIQ α200 SERVICE MANUAL
2138853
CHAPTER 2 – INSTALLATION (continued)
2–2–5 Unpacking LOGIQ α200 2–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–6 MTZ Probe Holder Installation (Option) 2–11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–7 Transducer Connection 2–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–8 Moving into Position 2–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–9 Adjusting System Clock 2–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2–2–10 Product Locator Installation Card 2–15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 3 – SYSTEM CONFIGURATION
3–1 INTRODUCTION 3–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–2 DIMENSIONS 3–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–3 ELECTRICAL SPECIFICA TIONS 3–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–3–1 Power Supply 3–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–3–2 Facility Power Receptacle 3–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–4 STORAGE AND OPERATION REQUIREMENTS 3–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–5 OPTIONAL PERIPHERALS 3–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–5–1 Peripherals/Accessories Connector Panel 3–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–5–2 List of Optional Peripherals 3–8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–5–3 Power Consumption of Optional Peripherals 3–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–6 TEST POINT, LED, DIP SWITCH AND RESET SWITCH 3–10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–6–1 Test Point List
The table below shows The Test Point list for LOGIQ α200. 3–10. . . . . . . . . . . . . . . . . . . . . . .
3–6–2 LED List
The table below shows the LED list for LOGIQ α200. 3–13. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3–6–3 DIP Switch
The table below shows the DIP Switch list for LOGIQ α200. 3–13. . . . . . . . . . . . . . . . . . . . . .
3–6–4 Reset Switch
Reset switch (S2) on edge of MST Assy used for resetting the system. 3–13. . . . . . . . . . . . .
ii
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 5
SECTION TITLE PAGE
LOGIQ α200 SERVICE MANUAL
2138853
CHAPTER 4 – FUNCTIONAL CHECKS
4–1 INTRODUCTION 4–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–1–1 Required Equipment 4–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–2 FUNCTIONAL CHECK PROCEDURES 4–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–2–1 Basic Controls 4–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–2–2 M-Mode Check 4–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–3 SMPS ADJUSTMENTS 4–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–3–1 SMPS Assy Access 4–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4–3–2 SMPS Adjustment Procedure 4–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 5 – DIAGRAMS
5–1 INTRODUCTION 5–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–2 LOGIQ α200 SYSTEM 5–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–3 BLOCK DIAGRAM 5–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–4 WIRING DIAGRAM 5–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5–5 CIRCUIT BOARD DESCRIPTION 5–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 6 – RENEWAL PARTS
6–1 RENEWAL PARTS 6–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2 DISASSEMBL Y/RE-ASSEMBLY 6–23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–1 Monitor Assy (FRU No. 100) 6–24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–2 Pot Set Assy (FRU No. 101) 6–26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–3 CRT Filter(FRU No. 102) 6–27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–4 Monitor Cover Set (FRU No. 103) 6–28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–5 Tilt Assy(FRU No. 104) 6–29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–6 Monitor Space Plate (FRU No. 105) 6–30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–7 Probe Holder (FRU No. 201) 6–31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–8 Holder Bracket Assy (FRU No. 202) 6–32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–9 Keyboard Cover Set (FRU No. 203) 6–34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–10 Keyboard Assy (FRU No. 204) 6–36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–11 Trackball Assy (FRU No. 205) 6–38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–12 TGC Assy (FRU No. 206) 6–39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–13 Encoder Set (FRU No. 207) 6–40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–14 Freeze/Record Key Assy (FRU No. 208) 6–41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–15 TGC Knob Set (FRU No. 209) 6–42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iii
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 5
SECTION TITLE PAGE
LOGIQ α200 SERVICE MANUAL
2138853
CHAPTER 6 – RENEWAL PARTS (continued)
6–2–16 Probe Protector Sheet Set (FRU No. 210) 6–43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–17 Key Sheet Assy (FRU No. 211) 6–44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–17 Key Sheet Assy (continued) (FRU No. 211) 6–45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–18 P.C.Board(s) (FRU No.301 through 304) 6–46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–19 HV Assy (FRU No. 305) 6–48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–20 CONN Assy (FRU No. 306) 6–50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–21 Shield Panel (FRU No. 307) 6–52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–22 Mother Assy (FRU No. 308) 6–54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–23 Nest Box (FRU No. 309) 6–56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–24 Swing Arm Assy (FRU No. 401) 6–58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–25 Pipe Assy (FRU No. 402) 6–60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–26 Pole Cover (FRU No. 403) 6–62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–27 Left Cover (FRU No. 404) 6–64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–28 Right Cover (FRU No. 405) 6–65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–29 Front Base Cover (FRU No. 406) 6–66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–30 Front Cover (FRU No. 407) 6–68. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–31 Rear Cover (FRU No. 408) 6–70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–32 Top Cover (FRU No. 409) 6–72. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–33 Printer Cover (FRU No. 410) 6–74. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–34 Printer Bracket Assy(FRU No. 411), Back Bracket Assy (FRU No. 412) 6–76. . . . . . . . . . . .
6–2–35 Rear Handle (FRU No. 413) 6–78. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–36 Neck Frame (FRU No. 414) 6–80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–37 Rear Panel Assy (FRU No. 415) 6–82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–38 Power S/W Assy (FRU No. 416) 6–84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–39 AC Fan Assy (FRU No. 417) 6–86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–40 Front Caster (FRU No. 418) 6–88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–41 Rear Caster (FRU No. 419) 6–89. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–42 Bumper Set (FRU No. 420) 6–90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–43 EMI Cover L (FRU No. 421) 6–91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–44 PCB Guide Assy (FRU No. 422) 6–92. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–45 Terminal Block 12 Assy (FRU No. 501) 6–94. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–46 Terminal Block 6 Assy (FRU No. 502) 6–96. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–47 SMPS Assy (FRU No. 503) 6–98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–48 Power Trans Assy (FRU No. 504) 6–100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–2–49 Circuit Breaker Set (FRU No. 505) 6–102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–3 FUSE REPLACEMENT 6–103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–3–1 Introduction 6–103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–3–2 Replacement Procedures 6–103. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–4 SMPS Assy REPLACEMENT 6–106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–4–1 Introduction 6–106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–4–2 Replacement Procedure 6–106. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 5
SECTION TITLE PAGE
LOGIQ α200 SERVICE MANUAL
2138853
CHAPTER 7 – PERIODIC MAINTENANCE
7–1 INTRODUCTION 7–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–1–1 Periodic Maintenance 7–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2 PERIODIC MAINTENANCE PROCEDURE 7–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2–1 Visual Inspection 7–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2–2 Cleaning 7–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2–3 Measurement 7–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2–4 Battery replacement 7–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–2–5 Note 7–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3 ELECTRICAL SAFETY TESTS 7–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3–1 Outlet Test Wiring Arrangement 7–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3–2 Grounding Continuity 7–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3–3 Chassis Leakage Current Test 7–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3–4 Probe Leakage Current Test 7–10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–3–5 When There’s Too Much Leakage Current... 7–14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 8 – INSTALLATION FOR OPTIONS
8–1 INTRODUCTION 8–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 5
LOGIQ α200 SERVICE MANUAL
2138853
This page is left blank intentionally.
vi
T ABLE OF CONTENTS
GE MEDICAL SYSTEMS
REV 2
LOGIQ α200 SERVICE MANUAL
2138853
CHAPTER 1 – INTRODUCTION
TABLE OF CONTENTS
SECTION TITLE PAGE
1–1 SERVICE MANUAL CONTENTS 1–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2 SAFETY 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2–1 Warnings 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–2–2 Specifications 1–17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3 EMC (Electromagnetic Compatibility) 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–1 EMC Performance 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–2 Notice upon Installation of Product 1–18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–3 General Notice 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–4 Countermeasures against EMC-related Issues 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–3–5 Notice on Service 1–19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–4 ADDRESS 1–20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1–1
INTRODUCTION
GE MEDICAL SYSTEMS
REV 2
LOGIQ α200 SERVICE MANUAL
2138853
This page is left blank intentionally.
1–2
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
LOGIQ α200 SERVICE MANUAL
2138853
1–1 SERVICE MANUAL CONTENTS
This manual provides service information on the LOGIQ α200 Ultrasound Scanning System. It contains the following chapters:
1. Chapter 1, Introduction: Contains a content summary and warnings.
2. Chapter 2, Installation: Contains physical and electrical requirements that must be considered prior to installation and a complete LOGIQ α200 installation procedure with installation checklist.
3. Chapter 3, System Configuration: Contains system configuration and specifications.
4. Chapter 4, Functional Checks: Contains functional checks that must be performed as part of the installation, or as required during servicing and periodic maintenance.
5. Chapter 5, Diagrams: Contains block diagrams and functional explanations of the LOGIQ α200 electronics.
6. Chapter 6, Renewal Parts: Contains a complete list of replacement parts for the LOGIQ α200 and disassembly procedures for all changeable FRU.
7. Chapter 7, Periodic Maintenance: Provides periodic maintenance procedures for the LOGIQ α200.
8. Chapter 8, Installation for Options: is provided to keep the option installation instructions supplied with each option.
1–3
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
1–2 SAFETY
1–2–1 Warnings
CAREFULLY READ ALL THE WARNINGS LISTED BELOW!
LOGIQ α200 SERVICE MANUAL
2138853
W ARNING!
1. The operator manual should be fully read and understood before operating the LOGIQ
α200 and kept nearby
for quick reference.
2. Although the ultrasound energy transmitted from the LOGIQ
α200 transducer is within AIUM/NEMA
standards, unnecessary exposure should be avoided. Only trained personnel should operate the LOGIQ α200.
3. To prevent electrical shock, the LOGIQ α200 should be connected to a properly grounded power receptacle. Do not use a three to two prong adapter. This defeats safety grounding.
4. Do not use with Defibrillator when LOGIQ
α200 is being operated .
5. Probes are fragile, please handle with care.
6. Concerning Outside Markings, refer to Illustration 1–1, 1–2, 1–3, 1–4, 1–5, 1–6, 1–7, 1–8, and 1–9.
7. For the cleaning, disinfection, and sterilization, refer to Probe section in LOGIQ α200 User Manual and Caution Sheet supplied with each probe.
NOTICE
This medical equipment is approved, in terms of the prevention of radio wave interference, to be used in hospitals, clinics and other institutions which are environmentally qualified. The use of this equipment in an inappropriate environment may cause some electronic interference to radios and televisions around the equipment. Proper handling of this equipment is required in order to avoid such trouble according to the operator and service manuals. This equipment can be used in residential areas only under the supervision of physicians or qualified technicians.
1–4
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
OUTSIDE MARKINGS OF LOGIQ α200 (FOR ALL UNITS)
ILLUSTRATION 1–1
1–5
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
OUTSIDE MARKINGS OFLOGIQ α200 (FOR ALL UNITS)
For further details regarding the cautions above, refer to 2–2–8 MOVING INTO POSITION in Chapter 2.
ILLUSTRATION 1–2
Note
1–6
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
OUTSIDE MARKINGS OFLOGIQ α200 (FOR ALL UNITS)
ILLUSTRATION 1–3
1–7
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
MODEL NUMBER : 2205674 MANUFACTURED
LOCATION: GE MEDICAL SYSTEMS KOREA S.N. : VOLT : 220–240V~ AMP. LONG TERM : 2.1A KVA : 0.5kVA PHASE : 1 DESC. : LOGIQ 200
CISPR 11 / EN 55011 CLASS : A GROUP : 1 CLASSE : A GROUPE : 1
Class1/Classe1
OUTSIDE MARKINGS OFLOGIQ α200 (FOR EUROPE )
For the symbols shown in the illustration above, refer to latter pages in this chapter.
ILLUSTRATION 1–4
Note
1–8
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
MADE FOR GE MEDICAL SYSTEMS MILWAKEE, WISCONSIN BY GE MEDICAL SYSTEMS KOREA
For USA Canada, Mexico
MODEL 2205675 SERIAL. MANUFACTURED VOLTS : 120Vac~ 1 PHASE POWER : 500VA FREQUENCY : 60HZ DESC, LOGIQ 200
LOGIQ α200 SERVICE MANUAL
2138853
CLASS 1
For Brazil
MADE FOR GE ME DICAL SYSTEMS MILWAKEE, WISCONSIN BY GE MEDICAL SYSTEMS KOREA
MODEL 2205676 SERIAL. MANUFACTURED VOLTS 220Vac~240Vac 1 PHASE POWER : 500VA FREQUENCY : 50HZ DESC, LOGIQ 200
CLASS 1
OUTSIDE MARKINGS OFLOGIQ α200 (FOR USA CANADA MAXICO BRAZIL)
ILLUSTRATION 1–5
1–9
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
MADE FOR GE MEDICAL SYSTEMS MILWAKEE, WISCONSIN BY GE MEDICAL SYSTEMS KOREA
MODEL 2205672 SERIAL. MANUFACTURED VOLTS :220Vac~240V ac 1 PHASE POWER : 500VA FREQUENCY : 50HZ DESC, LOGIQ 200
LOGIQ α200 SERVICE MANUAL
2138853
CLASS 1
For SEA, China, Hongkong, India, Australia, New Zealand
MADE FOR GE ME DICAL SYSTEMS MILWAKEE, WISCONSIN BY GE MEDICAL SYSTEMS KOREA
MODEL 2205671 SERIAL. MANUFACTURED VOLTS : 120Vac~ 1 PHASE POWER : 500VA FREQUENCY : 60HZ DESC, LOGIQ 200
For Taiwan Philippines
CLASS 1
OUTSIDE MARKINGS OFLOGIQ α200 (FOR SEA CHINA HONGKONG INDIA AUSTRALLIA NEWZEALAND TAIWAN PHILLIPPINES)
ILLUSTRATION 1–6
1–10
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
MADE FOR GE MEDICAL SYSTEMS MILWAKEE, WISCONSIN BY GE MEDICAL SYSTEMS KOREA
MODEL 2205677 SERIAL. : MANUFACTURED VOLTS : 220–240Vac~ 1 PHASE POWER : 500VA FREQUENCY : 60HZ DESC LOGIQ 200
OUTSIDE MARKINGS OFLOGIQ α200 (FOR CHILE)
CLASS 1
ILLUSTRATION 1–7
1–1 1
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
OUTSIDE MARKINGS OFLOGIQ α200 (FOR KOREA)
ILLUSTRATION 1–8
1–12
INTRODUCTION
GE MEDICAL SYSTEMS
REV 9
1–2–1 Warnings (Continued)
Do not use a Defibrillator simultaneously with the ECG, as its excessive voltage will damage the signal input block of the ECG unit.
LOGIQ α200 SERVICE MANUAL
2138853
CAUTION
OUTSIDE MARKINGS OF LOGIQ α200 (FOR UNITS WITH ECG)
ILLUSTRATION 1–9
1–13
INTRODUCTION
GE MEDICAL SYSTEMS
REV 0
1–2–1 Warnings (Continued)
LOGIQ α200 SERVICE MANUAL
2138853
NOTE: Two labels are attached on rear of the SMPS assy box inside the rear cover
and front of HV Board Assy inside the front base cover.
MARKINGS OF LOGIQ 500 (INSIDE COVERS)
ILLUSTRATION 1–10
1–14
INTRODUCTION