Gemco 955A BRIK Gen III Catalog Page

Gemco 955A BRIK Gen III
The 955A BRIK Gen III is an accurate programmable, auto-tuning, non-contact, linear displacement transducer in an economical, low profi le package. The transducer utilizes our fi eld proven magnetostrictive technology to give absolute position, repeatable to .006% of the programmable sensing distance.
The streamlined anodized aluminum extrusion houses the sensing element and electronics. The magnet moves over the sensing element that determines the position and converts it to an analog output. It can be ordered with a 0 to 10 VDC or 4 to 20mA output.
The 955A BRIK Gen III has a few truly unique features. The fi rst one is the LDT’s auto-tuning capability, the ability to sense a magnet other than the standard slide magnet and adjust its signal strength accordingly. Another feature is the analog output is programmable over the entire active stroke length. The active stroke area of the LDT lies between the Null and Dead zones. There is a diagnostic LED located at the connector end of the probe that remains green while a good magnet signal is present and when the magnet is in the programmed stroke area. The LED turns yellow when the magnet is out of the programmed active range, but still within the active stroke area. The LED turns red and the output goes to 0 volts on voltage output units, or 4mA on current output
955
units when there is no magnet present or when the magnet is out of the sensing area.
The unit can easily be changed in the fi eld from a 0 - 10 VDC to a 10 - 0 VDC or 4 - 20mA to a
20 - 4mA . As an added feature, the optional differential analog output allows the distance between two magnets to be measured.
The 955A BRIK is designed for applications where economical continuous feedback is necessary. The sensor can be a cost effective replacement to limit switches, proximity sensors, linear potentiometers and LVDT’s. Applications include presses, blow molding, injection molding, extrusion, roll positioning, dancer control and many more.
955A BRIK Gen III
Specifications
Input Voltage
Current Draw
Resolution Internal Analog Output
Linearity
Repeatbility
Hysteresis
Update
40” or less
41” to 100” 101” to 150” 151” to 180”
Operating Temperature
Span Length
Null Zone
Dead Band
LED
Connector
Approvals
Enclosure
Specifications are subject to change without notice.
Specifications are based on a typical 36” LDT.
13.5 to 30 VDC
2.5 Watts Maximum, 120mA @ 15 VDC Typical
0 to 10 VDC, 10 to 0 VDC, 4 to 20mA, 20 to 4mA
0.001” 16 Bit (1 part in 65,535)
+/- 0.05% of Stroke
+/- 0.006% of Full Stroke
+/- 0.02% of Full Scale
1ms (Stroke Lengths 5” to 40”) 2ms (Stroke Lengths 41” to 100”) 3ms (Stroke Lengths 101” to 150”) 4ms (Stroke Lengths 151” to 180”)
-20° to 70° C
5” to 180”
3.00”
2.00”
Green = Power is applied and magnet is present Red = Fault, magnet is in the Dead Band or lost Yellow = Out of the active programmed range
Standard 5 Pin Micro 12mm Euro Connector
CE
IP67, IP68 Optional
955A BRIK Gen III
Part Numbering
955A 0120V0
Output
V0
0 to 10 VDC
V1
10 to 0 VDC
C4
4 to 20mA
C2
20 to 4mA
D0
Differential 0 to 10 VDC*
D1
Differential 4 to 20mA*
Insert stroke to 0.1” as a four-place number, enter 12.0” stroke as 0120. OR Insert stroke in millimeters to 1mm. Enter as a four-place number followed by ‘M’. Example: 305mm stroke entered as 0305M.
*Analog differential output is the difference between two magnets. Minimum distance is 2.5”.
Wiring Diagram
Use Euro Connector (micro 12 mm single keyway) cordsets, available from most connector manufacturers or purchased from Ametek. Install according to the following diagram:
Program Input
(white wire)
Power 10 - 30VDC
(brown wire)
X
Stroke Length
Options
X
No options.
E
Wet environment, electronics sealed to IP68 rating
Accessories
Item Part Number
Slide Magnet SD0521800
Floating Magnet SD0522100
Wide Floating Magnet SD0551500
Mounting Foot SD0522000
6 Ft., 5 Pin Cable 949019L6
12 Ft., 5 Pin Cable 949019L12
6 Ft., 5 Pin Cable; Right Angle Connector 949020L6
12 Ft., 5 Pin Cable; Right Angle Connector 949020L12
Power Supply
Common
(blue wire)
2
3
1
5
4
Connector View
Analog Output Common
(grey wire)
Output
(black wire)
955