Gembird SIS-PMS-LAN User Manual

РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ
USER MANUAL
HANDBUCH
HANDLEIDING
MANUEL DESCRIPTIF
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
Silver Shield programmable surge protector
with LAN interface
Silver Shield programmierbare und
fernbedienbare Steckdosenleiste mit LAN-
Anschluss
Silver Shield programmeerbare stekkerdoos
met LAN interface
Silver Shield Boîtier commandé à distance et
programmable avec prise LAN
Программируемый сетевой фильтр с LAN-
интерфейсом
Програмований мережевий фільтр з LAN-
інтерфейсом
2
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
1. Introduction
Congratulations with your purchase of this Silver shield Power
Manager. Your SIS-PMS-LAN is an advanced surge protector with power
management features. Four sockets are individually manageable via the LAN interface.
The sockets can be switched on/off by a timer schedule, by user or different events. It is also possible to pre-program the unit event timer schedule (hardware schedule) and then disconnect SIS-PMS-LAN from LAN and use it elsewhere. The device can be used as an advanced standby-killer.
1.1. Features
The main rocker switch enables switching all the sockets on and off
In addition to it every manageable socket can be switched on and off
via the software control window or web browser
The unit can be pre-programmed via hardware-based schedule. The
hardware schedule will work even when the managing computer is
switched off
The unit will keep performing the programmed hardware time
schedule even after SIS-PMS-LAN is disconnected from the power
for some time
3
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
The manageable sockets can then be switched on and off by the
schedule, simple typical applications could be: “switch my
peripherals on every working day at 8:50 AM” etc
The manageable sockets can also be programmed with Power
Manager software to react whenever a certain event occurs
(Windows or other programs start-up/shutdown), simple typical
applications could be: “switch my scanner on when I want to scan”
or “switch my printer off whenever I exit Windows”
LAN interface: the unit can be assigned an IP address and/or a
network name as a shared LAN resource and can be afterwards
accessed and managed from anywhere within the local area network
or Internet
Built-in web-server: SIS-PMS-LAN can be managed from any
computer running Internet Explorer or any other web browser –
therefore a global access is possible
IP-filter and 64-bit password protected encryption of data guarantee
secure access to SIS-PMS-LAN
Real time Voltage monitor provides information about the actual
status of each manageable socket (on or off). This information can
be further utilized in various ways (e.g. to check the proper
execution of the switching commands)
4
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
1.2. Specifications
Input voltage: 220 – 230 VAC, 50 – 60 Hz
Maximum load: 10 A
Maximum power consumed by SIS-PMS-LAN: 2.5 W
Built in power supply and battery
Hardware schedule features:
Maximum number of independent hardware schedule events –
16 per socket
Time interval between the events – from 1 minute to 180 days
Timer accuracy: no more than 2 seconds error per day providing
power is always present. Otherwise there can be an additional (up to 2 seconds) error per each power off. There is no accumulation of errors at all if NTP correction option is set (see section 5.4 below)
Working temperature range: from +10 to +40 °C
Dimensions: 378 x 98 x 55 mm
Net weight: 1.0 kg
5
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
1.3. Hardware requirements
Local area network with RJ45 sockets
Any Internet-enabled computer connected to the local area network
Computer running Windows® 2000/XP/Vista or Windows 7 is
required for using the Power Manager software (use of this software
is not compulsory)
1.4. Package contents
SIS-PMS-LAN
User manual and Quick installation guide
RJ45 cross-over cable (red), RJ45 LAN cable (grey)
CD with Power Manager software for Windows
6
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
2. Indicators and controls of the SIS-PМS-LAN
Non manageable
Manageable socket 4
Manageable socket 3
Manageable socket 2
Manageable socket 1
Non manageable
socket
Side panel #1
Figure #1
socket
Indicator Socket 1
Side panel #2
Main rocker
switch (Z)
Power indicator
Indicator Socket 4
Indicator Socket 3
Indicator Socket 2
All brands and logos are registered trademarks of their respective owners
7
SURGE
2.1. Side panel #1
Reset
Button (A)
Master Switch
Button (B)
IP Config
Button (C)
SIS-PMS-LAN PROGRAMMABLE
PROTECTOR WITH LAN INTERFACE
Figure #2
Indicator
Schedule/LAN activity
LAN socket
8
All brands and logos are registered trademarks of their respective owners
SURGE
2.2. Side panel #2
SIS-PMS-LAN PROGRAMMABLE
PROTECTOR WITH LAN INTERFACE
Figure #3
Circuit breaker
Power cord
9
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
2.3. Indicators
Main rocker switch Z (see Figure #1 above) is lit – this means that
SIS-PMS-LAN is connected to the power supply and active
Power indicator (see Figure #1 above) is lit – this means that the
non-manageable sockets (marked with the sign ) are
switched on
The indicator Socket 1 (2,3,4) (see Figure #1 above) is lit – this
means that this particular socket is switched on
The indicator Schedule/LAN activity (see Figure #2 above) blinks
green – this means that there is some LAN activity taking place
The indicator Schedule/LAN activity (see Figure #2 above) blinks
red as the reset procedure is being executed
The indicator Schedule/LAN activity (see Figure #2 above) stays
red if an active hardware schedule for any socket exists
10
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
3. Installation
It is strongly recommended to avoid damp or wet places for
installation.
SIS-PMS-LAN should be connected to the European AC wall socket
of the standard DIN 49 440.
3.1. Getting started
Connect SIS-PMS-LAN to the wall socket first and then to the LAN
socket (or your computer LAN card) with the provided patch cord or
vice-versa.
SIS-PMS-LAN can now be switched on and off by means of the
Main rocker switch (Z).
Two (the first and the last) sockets of SIS-PMS-LAN are marked with
the symbol . These two sockets are switched on and off by
means of the Main rocker switch (Z) and cannot be managed by the
computer – so they are called non-manageable sockets in this
manual.
If SIS-PMS-LAN is switched on then the red indicator POWER is lit.
In this case both non-manageable sockets are now live and
connected to the power supply.
11
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
The sockets: Socket 1, Socket 2, Socket 3 and Socket 4 can be
managed or pre-programmed by computer via LAN. They are called
manageable sockets in this manual.
The manageable sockets of SIS-PMS-LAN can be programmed to
be on or off. The current status of each manageable socket is
represented by the corresponding indicator which will be lit if socket
has power to it.
If the Main rocker switch (Z) (see figure #1 above) is turned off then
the manageable sockets cannot be switched on by either web server,
Power manager software or the hardware schedule.
As soon as you turn the Main rocker switch (Z) on then the web
server, Power manager software or the hardware schedule will be
able to turn the manageable sockets on and off.
Master switch button (B) (see figure #2 above) can also switch all
the manageable sockets on and off regardless of their current status
or schedule that is being executed. To switch them on you should
keep the button pressed for 1-2 seconds. To switch them off you
should keep the button pressed for more than 3 seconds.
To protect the connected devices from possible high current and
short circuit SIS-PMS-LAN is equipped with the automatic circuit
breaker.
NOTE: If the total power consumption (or peak power) of the
devices, connected to SIS-PMS-LAN exceeds 2200 Watts, the
circuit breaker may power SIS-PMS-LAN off. In this case, please,
12
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
remove the excessive load first and then press the Circuit breaker
button to restore the power supply (see figure #3 above).
To be able to use SIS-PMS-LAN you will now have to complete its LAN configuration.
3.2. Preparing LAN configuration of SIS-PMS-LAN
Before configuring SIS-PMS-LAN hardware settings, please, let it obtain its IP address. Follow the steps below:
Make sure SIS-PMS-LAN is connected to the local network with the
provided RJ-45 cable (option A - recommended)
NOTE: you may prefer to connect SIS-PMS-LAN directly to the managing computer LAN adapter (network card) using the supplied crossover RJ-45 cable (option B)
Turn SIS-PMS-LAN off (with the Main rocker switch Z)
Press IP Config (C) button on the side control panel (see figure #2
above) with the tip of a pen
While holding it pressed, turn the Main rocker switch Z on and wait
for about 3 seconds until you hear the sockets switching twice
The above-mentioned procedure forces SIS-PMS-LAN to reset itself to the default settings (see below) ...
13
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
IP: 192.168.0.254
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
DNS:0.0.0.0
DHCP: enabled
IP filtering: disabled
Power Manager client port: 5000
.. and then search for an IP address from your eventual DHCP server If no DHCP server is found within 30 seconds, SIS-PMS-LAN will then automatically revert to the default settings (see above, with IP:
192.168.0.254) and additionally disable DHCP option.
3.3. Power Manager installation
It is now time to identify which IP address has been obtained by SIS­PMS-LAN. We need to carry out the following:
Insert the Power Manager CD into a PC CD-ROM drive. This PC
can be connected either to the same LAN where the device is (if you
chose option A section 3.2) or directly to the device with the
crossover RJ-45 cable (if you chose option B section 3.2)
If for any reason the automatic setup does not work, then open CD-
ROM drive in the My Computer window and launch SETUP.EXE
from the CD
Follow instructions of the installation software
14
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
NOTE: Antivirus or firewall software may block connection to SIS-
PMS-LAN. Please, configure antivirus/firewall to permit connection to the IP address and port of your SIS-PMS-LAN
3.4. IP configuration
The utility Find SIS-PMS-LAN (see Figure #4 below) will run automatically during the software installation but it can also be started from Start/All Programs/Gembird/Power Manager. The IP range where you would like to search for SIS-PMS-LAN will be set automatically according to the IP settings of your LAN adapter but can be changed manually in the Adapter subnet fields. Now press the Search button.
NOTE: only SIS-PMS-LAN within a local subnet can be found. If your computer LAN adapter is not in the (default) subnet of SIS-PMS­LAN (as might probably be the case if you chose option B section 3.2) you will have to change its IP address manually to be able to find SIS­PMS-LAN. For example if you wish to find SIS-PMS-LAN (with the default IP 192.168.0.254), the IP address of your computer should be set as
192.168.0.XXX (where XXX stands for any digit, for example 1) and the subnet mask should be 255.255.255.0.
After the searching the IP addresses of the found SIS-PMS-LAN devices will appear in the list box. Select SIS-PMS-LAN which you want to access, and press the Open button (see Figure #4 below).
15
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
Figure #4
The window of your default internet browser will be then opened to give you access to the built-in web-server. See section 4 below for the further details.
16
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
4. The web server
Your SIS-PMS-LAN is equipped with a web-server which allows managing the device using any web browser such as Internet Explorer etc.
4.1. Web-server login page
To access the web server of SIS-PMS-LAN, just open Internet Explorer (or other browser) and input the IP address of SIS-PMS-LAN (for example http://192.168.1.241). If you have used Find SIS-PMS-LAN utility to locate SIS-PMS-LAN then you will be taken to this webpage automatically. Login page will then be displayed (see Figure #5 below).
NOTE: Java script must be enabled in your Internet Explorer (or another browser) settings. Otherwise, you get an error message: WARNING! JAVASCRIPT IS DISABLED!
Figure #5
The default password is 1. It is recommended to change the password on the Device settings page (see section 4.4 below) after the first login.
17
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
After a successful login you will face the Socket 1 Status page (see section 4.2 below).
NOTE: There is a possibility that you might then need to open the LAN settings page (see section 4.3 below) to complete the IP configuration.
4.2. Socket page
There are 4 manageable sockets on SIS-PMS-LAN and so there are 4 pages corresponding to them. On each status page you can see the status of the socket (on or off) and you have the Switch On (Switch Off) button. Besides you can see the scheduled events for this socket.
The socket shown on the Figure #6 is currently off, it will be turned on automatically on the 27th of June at 9:59 and on the 28th of June at 10:59 it will be switched off again. The shown two events will be executed periodically, with a loop period of 2 days.
18
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
Figure #6
19
All brands and logos are registered trademarks of their respective owners
SIS-PMS-LAN PROGRAMMABLE
SURGE
PROTECTOR WITH LAN INTERFACE
Below the page you can see the current time of the web-server and eventual information about the last successful timer synchronization. Automatic timer synchronization is used if Use NTP for timer correction option is enabled (see section 4.4 below).
NOTE: If a certain socket has a switching fault, e.g. it should be switched on but the whole device is switched off, or it should be off but it does have voltage, then the warning message Wrong voltage on socket! will be shown above the Event schedule (see Figure #6 above). This message might also indicate that this socket is defective.
For setting up the socket schedule click Set schedule button. You will face then the page shown below (see Figure #7).
20
All brands and logos are registered trademarks of their respective owners
Loading...
+ 44 hidden pages