Gembird SIS-PM, MSiS-PM, SiS-PM-841, SIS-PMS User Manual

SSiillvveerr SShhiieelldd PPoowweerr MMaannaagge
err
MMiinnii SSiillvveerr SShhiieelldd PPoowweerr MMaannaagge
err
SSiillvveerr SShhiieelldd PPoowweerr MMaannaaggeerr 884
411
SSiillvveerr SShhiieelldd PPoowweerr MMaannaaggeerr
SS
((WWiitthh bbuuiilltt--iinn ppoowweerr ssuuppppllyy uunniitt)
)
USER MANUAL
2
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
Table of contents
1. Introduction and features of the SiS-PM/MSiS-PM/SiS-PM-841/SiS-PMS
1.1 SiS-PM / MSiS-PM
1.2 SiS-PM-841
1.3 SiS-PMS
2. Indicators and controls of the SiS-PМ or SiS-PMS
3. Side panel with connectors of the SiS-PM-841
4. Hardware requirements
5. Package contents
6. Installation of SiS-PM(S)
7. Connection of other devices to the SiS-PM(S)
8. Switching SiS-PM(S) on and off, connection to the managing computer
9. Software installation
10. Power Manager Help
11. Audible signals or indicators
12. Troubleshooting
3
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
1. Introduction and features of the SiS-PM/MSiS-PM/SiS-PM-841/SiS-PMS
Congratulations on purchasing the Silver shield Power Manager. Your SiS-PM or SiS-PMS (hereinafter SiS-PM(S)) is an advanced surge protector with power management features. Four sockets are individually manageable from the computer via the USB port interface.
E.g. can be switched on/off, by timer schedule, or triggered by user or different events. It is also possible to pre-program the unit event timer schedule and then disconnect the SiS-PM(S) from the computer (hardware schedule) and use it elsewhere. Additionally the hardware event schedule will work even with the managing computer switched off.
SiS-PM Power manager software has the following main features:
Manual on and off switching of every socket via the software
control window;
Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every working day at 8:50AM” etc
Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications include: “switch my scanner on when I want to scan” or “switch my printer off whenever I exit Windows”
The unit can be assigned a network name as a shared LAN
resource and can afterwards be accessed and managed from anywhere within the local area network.
4
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer switched off (for SiS-PM an optional power adapter is required for this function). The unit will keep performing the hardware time schedule even after SiS-PM(S) gets temporarily switched off.
Voltage monitor
The software management supports any number of SiS-PM, SiS-
PMS and MSiS-PM connected to the computer.
Management of SiS-PM(S) via the LAN and Internet.
Command line interface support for user software applications is
also possible.
MSiS-PM is a single socket version of SiS-PM
SiS-PMS is an advanced surge protector with power management
features. Four sockets are individually manageable from the computer via the USB port interface on the SiS-PMS. E.g. can be switched on/off, by timer schedule, or triggered by user or different on-screen-software events (like: switch on my scanner if I start image editing software, or switch on security lights and alarm when my webcam software detects motion in the image)
It is also possible to pre-program a timer schedule and then disconnect the SiS-PMS from the computer (hardware schedule) and use it else where. This hardware event schedule will work even when the connected computer is switched off. The Built-in transformer of SiS­PMS makes this possible.
5
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
SiS-PM-841 lets your external hardware (such as KVM switches *)
control SiS-PM-841 sockets, read the voltage being on the sockets through the PM interface.
SiS-PM-841 let’s you make a chain with 10 devices connected to one another to be controlled by external hardware (for example - by KVM switches *)
* Supported models of KVM switches: CAS-441-PM, CAS-841-PM
1.1 SIS-PM (Silver Shield Programmable Power Outlet Strip (6
outl/4 programmable) and MSiS-PM (Single socket Silver Shield)
SIS-PM is an advanced surge protector with power management features. Four sockets are individually manageable from the computer via the USB port interface on the SIS-PM.
E.g. can be switched on/off, by timer schedule, or triggered by user or different on-screen-software events (like: switch on my scanner if I start image editing software, or switch on security lights and alarm when my webcam software detects motion in the image)
It is also possible to pre-program a timer schedule and then disconnect the SIS-PM from the computer (hardware schedule) and use it else where. This hardware event schedule will work even when the connected computer is switched off (however, you need a general available 9V/500mA Power supply).
Includes Euro 20000 insurance for attached peripherals.
6
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
SiS-PM and MSiS-PM Features
The Power manager software has the following main features:
Manual switching of every socket on and off from the software
control window;
Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every working day at 8:50AM” etc
Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications include: “switch my scanner on when I want to scan” or “switch my printer off whenever I exit Windows”
The unit can be assigned a network name as a shared LAN
resource and can be afterwards accessed and managed from anywhere within the local area network.
Preprogramming of the hardware-based event time schedule.
The hardware schedule will work even with the managing computer switched off provided that the SIS-PM is connected to the optional power adapter. The unit will keep performing the hardware time schedule even when the SIS-PM is temporary switched off.
Voltage monitor
7
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
SiS-PM and MSiS-PM Specifications
AC sockets: 6 pcs (only 1 socket for MSiS-PM)
9V/500mA power adapter (optional for SiS-PM, not included)
Input voltage 220 – 230 VAC~ 50 – 60 Hz;
Maximum load current 10A;
Maximum current consumed by the SIS-PM from the computer
USB port - 350mA (for MSiS-PM - 100mA);
Maximum quantity of SIS-PM and MSiS-PM connected to one
computer at the same time – 16 pcs;
Plug and Play;
1.2 SIS-PM-841 (Silver Shield programmable and remotely
manageable power outlet strip)
SIS-PM family is a series of advanced surge protectors with power management features.
Main functions:
Four sockets are individually manageable from the computer via the USB port interface on the SIS-PM.
E.g. can be switched on/off, by timer schedule, or triggered by user or different on-screen-software events (like: switch on my scanner if I start image editing software, or switch on security lights and alarm when my webcam software detects motion in the image)
8
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
It is also possible to pre-program a timer schedule and then disconnect the SIS-PM from the computer (hardware schedule) and use it else where. This hardware event schedule will work even when the connected computer is switched off (however, you need a general available 9V/500mA Power supply).
SiS-PM-841 Features
Manual switching of every socket on and off from the software
control window;
Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every
working day at 8:50AM” etc
Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications
include: “switch my scanner on when I want to scan” or “switch my
printer off whenever I exit Windows”
Allows GEMBIRD CPU switches* to control the sockets remotely
Can be serial-chained up to 16 pcs and remotely controlled by
GEMBIRD CPU switches*
The unit can be assigned a network name as a shared Internet or
LAN resource and can be afterwards accessed and managed from
anywhere.
Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer
switched off provided that the SIS-PM is connected to the optional
9
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
power adapter. The unit will keep performing the hardware time
schedule even when the SIS-PM is temporary switched off.
Voltage monitor
*: GEMBIRD CPU switches with the power management:
CAS-441-PM, CAS-841-PM
SiS-PM-841 Specifications
9V/500mA power adapter (optional, not included), required for the
preprogrammed hardware-based schedule work
Power managment interface: RJ45 connectors, 2pcs
Input voltage 220 – 230 VAC~ 50 – 60 Hz;
Maximum load current 10A;
Maximum current consumed by the SIS-PM-841 from the computer
USB port - 350mA;
Plug and Play;
1.3 SIS-PMS (Silver Shield Programmable Power Outlet Strip
(built in transformer)
SIS-PMS is an advanced surge protector with power management features. Four sockets are individually manageable from the computer via the USB port interface on the SIS-PMS. E.g. can be switched on/off, by timer schedule, or triggered by user or different on-screen-software events
10
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
(like: switch on my scanner if I start image editing software, or switch on security lights and alarm when my webcam software detects motion in the image)
It is also possible to pre-program a timer schedule and then disconnect the SIS-PMS from the computer (hardware schedule) and use it else where. This hardware event schedule will work even when the connected computer is switched off. The Built-in transformer of SIS-PMS makes it possible.
SiS-PMS Features
The Power manager software has the following main features:
Manual switching of every socket on and off from the software
control window;
Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every working day at 8:50AM” etc
Switching sockets on and off when a certain event occurs (Windows
or other programs startup/shutdown), typical applications include: “switch my scanner on when I want to scan” or “switch my printer off whenever I exit Windows”
The unit can be assigned a network name as a shared LAN resource
and can be afterwards accessed and managed from anywhere within the local area network.
Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer switched
11
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
off. The unit will keep performing the hardware time schedule even when the SIS-PMS is temporary switched off.
Voltage monitor
SiS-PMS Specifications
Input voltage 220 – 230 VAC~ 50 – 60 Hz;
Maximum load current 10A;
Maximum current consumed by the SIS-PM from the computer USB
port - 350mA;
Maximum quantity of SIS-PMS connected to one computer at the
same time – 16 pcs;
Plug and Play;
12
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
2. Indicators and controls of the SiS-PМ or SiS-PMS
Main rocker switch
Indicator Socket 3
“Silence” button to
suppress beeps
Indicator
“POWER”
Non
-
manageable
socket
Indicator Socket 4
Hardware schedule power
supply connector 9VDC
0,5A
Indicator
Socket 2
Indicator
Socket 1
Non
-
manageable
socket
Socket 4
Socket 3
Socket 2
Socket 1
USB
Connector
13
GEMBIRD EUROPE B.V. http://www.gembird.eu
SIS
-
PM /
MS
iS-
PM /
SiS
-
PM
-
841 / SIS
-
PMS
USER MANUAL
3. Side panel with connectors of the SiS-PM-841
Hardware schedule
power supply
connector 9VDC 0,5A
2 x RJ45
connectors
for PM interface
USB
-
connector
“Silence” button to
suppress beeps
Loading...