SSiillvveerr SShhiieelldd PPoowweerr MMaannaagge
MMiinnii SSiillvveerr SShhiieelldd PPoowweerr MMaannaagge
err
SSiillvveerr SShhiieelldd PPoowweerr MMaannaaggeerr 884
411
SSiillvveerr SShhiieelldd PPoowweerr MMaannaaggeerr
SS
((WWiitthh bbuuiilltt--iinn ppoowweerr ssuuppppllyy uunniitt)
)

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
Table of contents
1. Introduction and features of the SiS-PM/MSiS-PM/SiS-PM-841/SiS-PMS
1.1 SiS-PM / MSiS-PM
1.2 SiS-PM-841
1.3 SiS-PMS
2. Indicators and controls of the SiS-PМ or SiS-PMS
3. Side panel with connectors of the SiS-PM-841
4. Hardware requirements
5. Package contents
6. Installation of SiS-PM(S)
7. Connection of other devices to the SiS-PM(S)
8. Switching SiS-PM(S) on and off, connection to the managing computer
9. Software installation
10. Power Manager Help
11. Audible signals or indicators
12. Troubleshooting

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
1. Introduction and features
of the SiS-PM/MSiS-PM/SiS-PM-841/SiS-PMS
Congratulations on purchasing the Silver shield Power Manager.
Your SiS-PM or SiS-PMS (hereinafter SiS-PM(S)) is an advanced surge
protector with power management features. Four sockets are
individually manageable from the computer via the USB port interface.
E.g. can be switched on/off, by timer schedule, or triggered by user
or different events. It is also possible to pre-program the unit event timer
schedule and then disconnect the SiS-PM(S) from the computer
(hardware schedule) and use it elsewhere. Additionally the hardware
event schedule will work even with the managing computer switched off.
SiS-PM Power manager software has the following main features:
• Manual on and off switching of every socket via the software
control window;
• Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every
working day at 8:50AM” etc
• Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications
include: “switch my scanner on when I want to scan” or “switch my
printer off whenever I exit Windows”
• The unit can be assigned a network name as a shared LAN
resource and can afterwards be accessed and managed from anywhere
within the local area network.

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
• Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer
switched off (for SiS-PM an optional power adapter is required for this
function). The unit will keep performing the hardware time schedule
even after SiS-PM(S) gets temporarily switched off.
• Voltage monitor
• The software management supports any number of SiS-PM, SiS-
PMS and MSiS-PM connected to the computer.
• Management of SiS-PM(S) via the LAN and Internet.
• Command line interface support for user software applications is
also possible.
MSiS-PM is a single socket version of SiS-PM
SiS-PMS is an advanced surge protector with power management
features. Four sockets are individually manageable from the computer
via the USB port interface on the SiS-PMS. E.g. can be switched on/off,
by timer schedule, or triggered by user or different on-screen-software
events (like: switch on my scanner if I start image editing software, or
switch on security lights and alarm when my webcam software detects
motion in the image)
It is also possible to pre-program a timer schedule and then
disconnect the SiS-PMS from the computer (hardware schedule) and
use it else where. This hardware event schedule will work even when
the connected computer is switched off. The Built-in transformer of SiSPMS makes this possible.

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
SiS-PM-841 lets your external hardware (such as KVM switches *)
control SiS-PM-841 sockets, read the voltage being on the sockets
through the PM interface.
SiS-PM-841 let’s you make a chain with 10 devices connected to
one another to be controlled by external hardware (for example - by
KVM switches *)
* Supported models of KVM switches: CAS-441-PM, CAS-841-PM
1.1 SIS-PM (Silver Shield Programmable Power Outlet Strip (6
outl/4 programmable) and MSiS-PM (Single socket Silver Shield)
SIS-PM is an advanced surge protector with power management
features. Four sockets are individually manageable from the computer via
the USB port interface on the SIS-PM.
E.g. can be switched on/off, by timer schedule, or triggered by user or
different on-screen-software events (like: switch on my scanner if I start
image editing software, or switch on security lights and alarm when my
webcam software detects motion in the image)
It is also possible to pre-program a timer schedule and then
disconnect the SIS-PM from the computer (hardware schedule) and use it
else where. This hardware event schedule will work even when the
connected computer is switched off (however, you need a general
available 9V/500mA Power supply).
Includes Euro 20000 insurance for attached peripherals.

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
SiS-PM and MSiS-PM Features
The Power manager software has the following main features:
• Manual switching of every socket on and off from the software
control window;
• Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every
working day at 8:50AM” etc
• Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications include:
“switch my scanner on when I want to scan” or “switch my printer off
whenever I exit Windows”
• The unit can be assigned a network name as a shared LAN
resource and can be afterwards accessed and managed from anywhere
within the local area network.
• Preprogramming of the hardware-based event time schedule.
The hardware schedule will work even with the managing computer
switched off provided that the SIS-PM is connected to the optional power
adapter. The unit will keep performing the hardware time schedule even
when the SIS-PM is temporary switched off.
• Voltage monitor

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
SiS-PM and MSiS-PM Specifications
• AC sockets: 6 pcs (only 1 socket for MSiS-PM)
• 9V/500mA power adapter (optional for SiS-PM, not included)
• Input voltage 220 – 230 VAC~ 50 – 60 Hz;
• Maximum load current 10A;
• Maximum current consumed by the SIS-PM from the computer
USB port - 350mA (for MSiS-PM - 100mA);
• Maximum quantity of SIS-PM and MSiS-PM connected to one
computer at the same time – 16 pcs;
• Plug and Play;
1.2 SIS-PM-841 (Silver Shield programmable and remotely
manageable power outlet strip)
SIS-PM family is a series of advanced surge protectors with power
management features.
Main functions:
Four sockets are individually manageable from the computer via the
USB port interface on the SIS-PM.
E.g. can be switched on/off, by timer schedule, or triggered by user or
different on-screen-software events (like: switch on my scanner if I start
image editing software, or switch on security lights and alarm when my
webcam software detects motion in the image)

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
It is also possible to pre-program a timer schedule and then
disconnect the SIS-PM from the computer (hardware schedule) and use it
else where. This hardware event schedule will work even when the
connected computer is switched off (however, you need a general
available 9V/500mA Power supply).
SiS-PM-841 Features
• Manual switching of every socket on and off from the software
control window;
• Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every
working day at 8:50AM” etc
• Switching sockets on and off when a certain event occurs
(Windows or other programs startup/shutdown), typical applications
include: “switch my scanner on when I want to scan” or “switch my
printer off whenever I exit Windows”
• Allows GEMBIRD CPU switches* to control the sockets remotely
• Can be serial-chained up to 16 pcs and remotely controlled by
GEMBIRD CPU switches*
• The unit can be assigned a network name as a shared Internet or
LAN resource and can be afterwards accessed and managed from
anywhere.
• Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer
switched off provided that the SIS-PM is connected to the optional

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
power adapter. The unit will keep performing the hardware time
schedule even when the SIS-PM is temporary switched off.
• Voltage monitor
*: GEMBIRD CPU switches with the power management:
CAS-441-PM, CAS-841-PM
SiS-PM-841 Specifications
• 9V/500mA power adapter (optional, not included), required for the
preprogrammed hardware-based schedule work
• Power managment interface: RJ45 connectors, 2pcs
• Input voltage 220 – 230 VAC~ 50 – 60 Hz;
• Maximum load current 10A;
• Maximum current consumed by the SIS-PM-841 from the computer
USB port - 350mA;
• Plug and Play;
1.3 SIS-PMS (Silver Shield Programmable Power Outlet Strip
(built in transformer)
SIS-PMS is an advanced surge protector with power management
features. Four sockets are individually manageable from the computer via
the USB port interface on the SIS-PMS. E.g. can be switched on/off, by
timer schedule, or triggered by user or different on-screen-software events

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
(like: switch on my scanner if I start image editing software, or switch on
security lights and alarm when my webcam software detects motion in the
image)
It is also possible to pre-program a timer schedule and then
disconnect the SIS-PMS from the computer (hardware schedule) and use it
else where. This hardware event schedule will work even when the
connected computer is switched off. The Built-in transformer of SIS-PMS
makes it possible.
SiS-PMS Features
• The Power manager software has the following main features:
• Manual switching of every socket on and off from the software
control window;
• Switching sockets on and off according to the timer schedule of
events, typical applications include: “switch my peripherals on every
working day at 8:50AM” etc
• Switching sockets on and off when a certain event occurs (Windows
or other programs startup/shutdown), typical applications include: “switch
my scanner on when I want to scan” or “switch my printer off whenever I
exit Windows”
• The unit can be assigned a network name as a shared LAN resource
and can be afterwards accessed and managed from anywhere within the
local area network.
• Preprogramming of the hardware-based event time schedule. The
hardware schedule will work even with the managing computer switched

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
off. The unit will keep performing the hardware time schedule even when
the SIS-PMS is temporary switched off.
• Voltage monitor
SiS-PMS Specifications
• Input voltage 220 – 230 VAC~ 50 – 60 Hz;
• Maximum load current 10A;
• Maximum current consumed by the SIS-PM from the computer USB
port - 350mA;
• Maximum quantity of SIS-PMS connected to one computer at the
same time – 16 pcs;
• Plug and Play;

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
2. Indicators and controls of the SiS-PМ or SiS-PMS

GEMBIRD EUROPE B.V. http://www.gembird.eu
USER MANUAL
3. Side panel with connectors of the SiS-PM-841
power supply
connector 9VDC 0,5A
connectors
for PM interface