Gemalto M2M PLAS9 X User Manual

Cinterion® PLAS9-X
Hardware Interface Overview Version: 00.044
DocId: PLAS9-X_HIO_v00.044
M2M.GEMALTO.COM
Cinterion® PLAS9-X Hardware Interface Overview
2
Page 2 of 39
Document Name: Version:
Date: DocId: Status
Cinterion
®
PLAS9-X Hardware Interface Overview
00.044 2017-09-19 PLAS9-X_HIO_v00.044 Confidential / Preliminary
GENERAL NOTE
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its con­tents and communication thereof to others without ex press autho rization are prohib ited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.
Copyright © 2017, Gemalto M2M GmbH, a Gemalto Company
Trademark Notice
Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries. Microsoft and Win dows are e ither regis tered trademarks or trademarks of Microsoft Corpora­tion in the United States and/or other countries. All other register ed trademarks or trademarks mention ed in this document are property of their respective owners.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

Contents

39
Page 3 of 39
Contents
1 Introduction.................................................................................................................6
1.1 Key Features at a Glance..................................................................................6
1.2 PLAS9-X System Overview...............................................................................9
2 Interface Characteristics.......................................................................................... 10
2.1 Application Interface ........................................................................................10
2.1.1 USB Interface......................................................................................10
2.1.2 UICC/SIM/USIM Interface...................................................................11
2.1.3 Analog-to-Digital Converter (ADC)......................................................13
2.1.4 GPIO Interface....................................................................................13
2.1.5 Control Signals....................................................................................14
2.1.5.1 PWR_IND Signal.................................................................14
2.1.5.2 Behavior of the RING0 Line................................................14
2.1.5.3 Remote Wakeup..................................................................14
2.1.5.4 Low Current Indicator..........................................................14
2.2 GSM/UMTS/LTE Antenna Interface.................................................................15
2.2.1 Antenna Installation ............................................................................16
2.2.2 RF Line Routing Design......................................................................17
2.2.2.1 Line Arrangement Instructions ............................................17
2.2.2.2 Routing Examples...............................................................19
2.3 Sample Application..........................................................................................21
3 Operating Characteristics........................................................................................23
3.1 Operating Modes .............................................................................................23
3.2 Power Supply...................................................................................................24
4 Mechanical Dimensions ...........................................................................................25
4.1 Mechanical Dimensions of PLAS9-X...............................................................25
5 Regulatory and Type Approval Information........................................................... 27
5.1 Directives and Standards.................................................................................27
5.2 SAR requirements specific to portable mobiles............................................... 29
5.3 Reference Equipment for Type Approval.........................................................30
5.4 Compliance with FCC and IC Rules and Regulations ..................................... 31
6 Document Information..............................................................................................33
6.1 Revision History...............................................................................................33
6.2 Related Documents .........................................................................................33
6.3 Terms and Abbreviations.................................................................................33
6.4 Safety Precaution Notes..................................................................................36
7 Appendix....................................................................................................................37
7.1 List of Parts and Accessories...........................................................................37
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

Tables

39
Page 4 of 39
Tables
Table 1: Signals of the SIM interface (SMT application interface)............................... 11
Table 2: Return loss in the active band........................................................................ 15
Table 3: Overview of operating modes ........................................................................ 23
Table 4: Directives ....................................................................................................... 27
Table 5: Standards of North American type approval.................................................. 27
Table 6: Requirements of quality ................................................................................. 27
Table 7: Standards of the Ministry of Information Industry of the
People’s Republic of China............................................................................ 28
Table 8: Toxic or hazardous substances or elements with defined concentration
limits............................................................................................................... 28
Table 9: Antenna gain limits for FCC and IC (TBD.).................................................... 31
Table 10: List of parts and accessories.......................................................................... 37
Table 11: Molex sales contacts (subject to change)...................................................... 38
Table 12: Hirose sales contacts (subject to change)..................................................... 38
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

Figures

39
Page 5 of 39
Figures
Figure 1: PLAS9-X system overview............................................................................... 9
Figure 2: USB circuit ..................................................................................................... 10
Figure 3: First UICC/SIM/USIM interface...................................................................... 12
Figure 4: Second UICC/SIM/USIM interface................................................................. 12
Figure 5: Embedded Stripline line arrangement............................................................ 17
Figure 6: Micro-Stripline line arrangement samples...................................................... 18
Figure 7: Routing to application‘s RF connector ........................................................... 19
Figure 8: Routing to PLAS9-X evaluation module‘s RF connector................................ 20
Figure 9: PLAS9-X sample application.......................................................................... 22
Figure 10: Decoupling capacitor(s) for BATT+................................................................ 24
Figure 11: PLAS9-X – top and bottom view.................................................................... 25
Figure 12: Dimensions of PLAS9-X (all dimensions in mm)............................................ 26
Figure 13: Reference equipment for type approval......................................................... 30
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

1 Introduction

9
Page 6 of 39
1 Introduction
This document1 describes the hardware of the Cinterion® PLAS9-X module. It helps you quickly retrieve interface specifications, electrical and mechanical details and information on the re­quirements to be considered for integrating further components.

1.1 Key Features at a Glance

Feature Implementation
General Frequency bands GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
UMTS/HSPA+: Triple band, 850 (BdV), 1700 (BdIV), 1900 (BdII) LTE (FDD): Six band, 700 (Bd12 <MFBI Bd17>, Bd13, Bd29 <supple men­tary downlink>), 850 (Bd5), 1700 (Bd4), 1900 (Bd2)
GSM class Small MS Output power
(according to Release 99)
Output power (according to Release 8)
Power supply 3.3V < Operating temperature
(board temperature) Physical Dimensions: 40mm x 32mm x 2.8mm
Class 4 (+33dBm ±2dB) for EGSM850 Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII Class 3 (+24dBm +1/-3dB) for UMTS 1700, WCDMA FDD BdIV Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
LTE (FDD): Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD Bd12 <MFBI Bd17> Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD Bd13 Class 3 (+23dBm +-2dB) for LTE 850, LTE FDD Bd5 Class 3 (+23dBm +-2dB) for LTE 1700, LTE FDD Bd4 Class 3 (+23dBm +-2dB) for LTE1900, LTE FDD Bd2
V
Normal operation: -30°C to +85°C Extended operation: -40°C to +95°C
Weight: approx. 6.5g
BATT+
< 4.2V
RoHS All hardware components fully compliant with EU RoHS Directive
1. The document is effective only if listed in the appropriate Release Notes as part of the technical docu­mentation delivered with your Gemalto M2M product.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
1.1 Key Features at a Glance
9
Feature Implementation
LTE features 3GPP Release 10 Downlink carrier aggregation (CA) to increase bandwidth, and thereby
increase bitrate:
Maximum aggregated bandwidth: 40MHz
Maximum number of component carriers: 2
Inter-band FDD, non-contiguous
Intra-band FDD, contiguous, non-contiguous
Supported inter-band CA configurations: CA_2A-5A (with bandwidth combination set 0),
CA_2A-12A (with bandwidth combination sets 0 and 1), CA_2A-29A (with bandwidth combina tio n se ts 0, 1 and 2), CA_4A-5A (with bandwidth combination sets 0 and 1), CA_4A-12A (with bandwidth combination sets 0, 1, 2, 3 and 4), CA_4A-29A (with bandwidth combina tio n se ts 0, 1 and 2)
Supported intra-band CA configurations: CA_4A-4A (with bandwidth combination set 0)
CAT 6 supported DL 300Mbps, UL 50Mbps 2x2 MIMO in DL direction
Page 7 of 39
HSPA features 3GPP Release 9 UE CAT. 14, 24
DC-HSPA+ – DL 42Mbps HSUPA – UL 5.76Mbps
Compressed mode (CM) supported according to 3GPP TS25.212 UMTS features 3GPP Release 9 PS data rate – 384 kbps DL / 384 kbps UL GSM / GPRS / EGPRS features Data transfer GPRS:
Multislot Class 12
Mobile Station Class B
Coding Scheme 1 – 4
EGPRS:
Multislot Class 12
EDGE E2 power class for 8 PSK
Downlink coding schemes – CS 1-4, MCS 1-9
Uplink coding schemes – CS 1-4, MCS 1-9
SRB loopback and test mode B
8-bit, 11-bit RACH
1 phase/2 phase access procedures
Link adaptation and IR
NACC, extended UL TBF
Mobile Station Class B
SMS Point-to-point MT and MO, Cell broadcast,
Text and PDU mode
Software AT commands Hayes, 3GPP TS 27.007 and 27.005, and proprietary Gemalto M2M com-
mands
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
1.1 Key Features at a Glance
9
Feature Implementation
Firmware update Generic update from host application over USB 2.0 High Speed device
interface
Interfaces Module interface Surface mount device with solderable connection pads (SMT application
interface).
Land grid array (LGA) technology ensures high solder joint reliability and
provides the possibility to use an optional module mounting socket.
For more information on how to integrate SMT modules see also [3]. This
application note comprises chapters on module mounting and app lication
layout issues as well as on additional SMT application development equip-
ment. Antenna 50. GSM/UMTS/LTE main antenna, UMTS/LTE Diversity/MIMO antenna USB USB 2.0 High Speed (480Mbit/s) device interface or
USB 3.0 Super Speed (5Gbit/s) device interface UICC interface 2 UICC interfaces (switchable)
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Page 8 of 39
RING0 Signal line to indicate URCs.
Power on/off, Reset Power on/off Switch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO) or IGT (option)
Automatic switch-off in case of critical temperature or voltage conditions Reset Orderly shutdown and reset by AT command Emergency-off Emergency-off by hardware signal EMERG_OFF
Special Features Antenna SAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx Diversity (receiver type 3i - 64-QAM) / MIMO GPIO 10 I/O pins of the application interface programmable as GPIO.
Programming is done via AT commands. ADC inputs Analog-to-Digital Converter with two unbalanced analog inputs for (exter-
nal) antenna diagnosis Evaluation kit Evaluation module PLAS9-X module soldered onto a dedicated PCB that can be connected
to the ALAS6A-DSB75 adapter in order to be mounted onto the DSB75. ALAS6A-DSB75 adapter A special adapter required to connect the PLAS9-X evaluation module to
the DSB75. DSB75 DSB75 Development Support Board designed to test and type approve
Gemalto M2M modules and provide a sample configuration for application
engineering.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
GPIO ADC UICC
Power supply
IGT,
Emergency Off
SIM
card
Hos t application
On/Off
Module
Application
Power indication
(PWR_IND)
GSM/UMTS/LTE
Power for application
(VEXT)
USB
GSM/UMTS/LTE Ant enna d iv ersi ty
12
Antenna
diagnostic
Antenna
switch
2x
GPIO
2x
ADC
SIM card
RING0

1.2 PLAS9-X System Overview

9
1.2 PLAS9-X System Overview
Page 9 of 39
Figure 1: PLAS9-X system overview
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
VREG (3V075)
BATT+
USB_DP
3)
lin. reg.
GND
Module
Detection only
VUSB_IN
2)
USB part
1)
1)
All serial (including RS) and pull-up resistors for da ta lines are implemented.
USB_DN
3)
3)
If the USB interface is op erated in High Speed mode (480MHz), it is recommen ded to take special care routing the data lines USB_DP and USB_DN. Application layout should in this case implement a differen tial impedance of 90 ohms for proper signal integrity.
VBUS
1µF
2)
Since VUSB_IN is used for detection only it is recommended not to add any further blocking capacitors on the VUSB_IN line.
Host wakeup
RING0
USB_SSRX_N USB_SSRX_P
USB_SSTX_N USB_SSTX_P
USB_SS
_PHY
USB_HS
_PHY
USB 2.0
Controller
USB 3.0
Controller
2.0
2.0
3.0
100nF
100nF
SMT
Page 10 of 39

2 Interface Characteristics

22
2 Interface Characteristics
PLAS9-X is equipped with an SMT application interface that connects to the external applica­tion. The SMT application interface incorporates the various application interfaces as well as the RF antenna interface.

2.1 Application Interface

2.1.1 USB Interface

PLAS9-X supports a USB 3.0 Super Speed (5Gbps) device interface, and alternatively a USB 2.0 device interface that is High Speed and Full Speed compatible. The USB interface is primarily intended for use as command and data interface, and for downloading firmware
The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because PLAS9-X is designed as a self-powered device compliant with the “Universal Serial Bus Spec-
2
ification Revision 3.0”
.
1
.
To properly connect the module's USB interface to the external application, a USB 3.0 or 2.0 compatible connector and cable or hardware design is required. Furthermore, the USB modem driver distributed with PLAS9-X needs to be installed.
1. Note: For firmware download, the module enumerates new as a USB 2.0 device. Also, it is not possible
Figure 2: USB circuit
to use the USB 2.0 High Speed device mode and the USB 3.0 Super speed device mode simultaneously.
2. The specification is ready for download on http://www.usb.org/developers/docs/
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.1 Application Interface
22
Page 11 of 39

2.1.2 UICC/SIM/USIM Interface

PLAS9-X has two UICC/SIM/USIM interfaces compatible with the 3GPP 31.102 and ETSI 102
221. These are wired to the host interface in order to be connected to an external SIM card holder. Five pads on the SMT application interface are reserved for each of the two SIM inter­faces.
The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards. The CCINx signal serves to detect whether a tray (with SIM card) is present in the card holder.
Using the CCINx signal is mandatory for compliance with the GSM 11.11 recommendation if the mechanical design of the host application allows the user to remove the SIM card during operation. To take advantage of this feature, an appropriate SIM card detect switch is required on the card holder. For example, this is true for the model supplied by Molex, which has been tested to operate with PLAS9-X and is part of the Gemalto M2M reference equipment submit­ted for type approval. See Chapter 7 for Molex ordering numbers.
Table 1: Signals of the SIM interface (SMT application interface)
Signal Description
GND Ground connection for SIM interfaces. Optionally a separate SIM ground line using e.g.,
pad P12, may be used to improve EMC.
CCCLK1 CCCLK2
CCVCC1 CCVCC2
CCIO1 CCIO2
CCRST1 CCRST2
CCIN1 CCIN2
Chipcard clock lines for 1
SIM supply voltage lines for 1
Serial data lines for 1
Chipcard reset lines for 1
Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is removed during operation the SIM interface is shut down immediately to prevent destruc­tion of the SIM. The CCINx signal is active low. The CCINx signal is mandatory for applications that allow the user to remove the SIM card during operation. The CCINx signal is solely intended for use with a SIM card. It must not be used for any other purposes. Failure to comply with this requirement may inva lidate the type approval of PLAS9-X.
st
and 2nd SIM interface.
st
and 2nd SIM interface.
st
and 2nd SIM interface, input and output.
st
and 2nd SIM interface.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after removing the SIM card during operation. Also, no guarantee can be given for properly initializ­ing any SIM card that the user inserts after having removed the SIM card during operation. In this case, the application must restart PLAS9-X.
By default, only the 1
st
SIM interface is available and can be used. Using the AT command AT^SCFG=”SIM/CS” it is possible to switch between the two SIM interfaces. Command set­tings are non-volatile - for details see [1].
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
Module
open: Card removed closed: Card inserted
CCRST1
CCVCC1
CCIO1
CCCLK1
CCIN1
SIM / UICC
1n
220n
SMT application interface
GND
Module
Open: Card removed Closed: Card inserted
CCRST2
CCVCC2
CCIO2
CCCLK2
CCIN2
SIM /
UICC
1nF
220nF
SMT application interface
GND
VEXT
100pF
22k
2k2
10k
2.1 Application Interface
22
Figure 3: First UICC/SIM/USIM interface
Page 12 of 39
The total cable length between the SMT application interface pads on PLAS9-X and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance.
To avoid possible cross-talk from the CCCLKx signal to the CCIOx signal be careful that both lines are not placed closely next to each other. A useful approach is using the GND line to shield the CCIOx line from the CCCLKx line.
Note: Figure 3 shows how to connect a SIM card holder to the first SIM interface . With the sec­ond SIM interface some internally integrated components on the SIM circuit will have to be ex­ternally integrated as shown for the second SIM interface in Figure 4. The external co mponents at CCIN2 should be populated as close as possible to the signal‘s SMT pad
Figure 4: Second UICC/SIM/USIM interface
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.1 Application Interface
22
Page 13 of 39

2.1.3 Analog-to-Digital Converter (ADC)

PLAS9-X provides two unbalanced ADC input lines: ADC1_IN and ADC2_IN. They can be used to measure two independent, externally connected DC voltages in the range of 0.05V to V
.
BATT+

2.1.4 GPIO Interface

PLAS9-X has 10 GPIOs for external hardware devices. Each GPIO can be configured for use as input or output. All settings are AT command controlled.
GPIO1...GPIO10 may be configured as low current indicator signal (see Section 2.1.5.4), or may be set as remote host wakeup lines (see Section 2.1.5.3).
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.1 Application Interface
22
Page 14 of 39

2.1.5 Control Signals

2.1.5.1 PWR_IND Signal
PWR_IND notifies the on/off state of the module. High state of PWR_IND indicates that the module is switched off. The state of PWR_IND immediately changes to low when IGT is pulled low. For state detection an external pull-up resistor is required.
2.1.5.2 Behavior of the RING0 Line
The RING0 line serves to indicate URCs (Unsolicited Result Code). The RING0 line behavior and usage can be configured by AT command. For details see [1]:
AT^SCFG.
2.1.5.3 Remote Wakeup
If no call, data or message transfer is in progress, the external host application may shut down its own module interfaces or other components in order to save power. If a call, data, or other request (URC) arrives, the external application can be notified of this event and be woken up again by a state transition of a configurable remote wakeup line. Available as remote wakeup lines are all GPIO signals as well as the RING0 line. Please refer to [1]: AT^SCFG: "Re­moteWakeUp/..." for details on how to configure these lines for defined wakeup events on specified device interfaces.
2.1.5.4 Low Current Indicator
A low current indication is optionally available over a GPIO line. By default, low current indica­tion is disabled and the GPIO pads can be configured and employed as usual.
For a GPIO pad to work as a low current indicator the feature has to be enabled by AT com­mand (see [1]: AT^SCFG: MEopMode/PowerMgmt/LCI). By default, the GPIO6 pad is config­ured as LCI_IND signal.
If enabled, the GPIOx/LCI_IND signal is high when the module is sleeping.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

2.2 GSM/UMTS/LTE Antenna Interface

22
2.2 GSM/UMTS/LTE Antenna Interface
Page 15 of 39
The PLAS9-X GSM/UMTS/LTE antenna interface comprises a GSM/UMTS/LTE main antenna as well as a UMTS/LTE Rx diversity/MIMO antenna to improve signal reliability and quality The interface has an impedance of 50
. PLAS9-X is capable of sustaining a total mismatch at
1
. the antenna interface without any damage, even when transmitting at maximum RF power. The external antennas must be matched properly to achieve best performance regarding radi-
ated power, modulation accuracy and harmonic suppression. Matching networks are not in­cluded on the PLAS9-X PCB and should be placed in the host application, if the antenna does not have an impedance of 50
.
Regarding the return loss PLAS9-X provides the following values in the active band:
Table 2: Return loss in the active band
State of module Return loss of module Recommended return loss of application
Receive > Transmit not applicable > Idle <
8dB > 12dB
12dB
5dB not applicable
1. By delivery default the UMTS/LTE Rx diversity/MIMO antenna is configured as available for the module since its usage is mandatory for LTE. Please refer to [1] for details on how to configure antenna settings.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.2 GSM/UMTS/LTE Antenna Interface
22
Page 16 of 39

2.2.1 Antenna Installation

The antenna is connected by soldering the antenna pads (ANT_MAIN; ANT_DRX_MIMO) and their neighboring ground pads directly to the application’s PCB.
The distance between the antenna pads and their neighboring GND pads has been optimized for best possible impedance. To prevent mismatch, special attention should be paid to these pads on the application’ PCB.The wiring of the antenna connection, starting from the antenna pad to the application’s antenna must result in a 50 to the GND plane need to be optimized with regard to the PCB’s layer stack. Related instruc­tions are given in Section 2.2.2.
To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the external application PCB, it is recommended to realize the antenna con­nection line using embedded Stripline rather than Micro-Stripline technology. Please see Sec-
tion 2.2.2 for instructions of how to design the antenna connection in order to achieve the
required 50
line impedance.
line impedance. Line width and distance
For type approval purposes (i.e., FCC KDB 996369 related to modular approval requirements), an external application must connect the RF signal in one of the following ways:
•Via 50
coaxial antenna connector (common connectors are U-FL or SMA) placed as close
as possible to the module's antenna pad.
By soldering the antenna to the antenna connection line on the application’s PCB (without the use of any connector) as close as possible to the module’s antenna pad.
By routing the application PCB’s antenna to the module’s antenna pad in the shortest pos­sible way.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.2 GSM/UMTS/LTE Antenna Interface
22
Page 17 of 39

2.2.2 RF Line Routing Design

2.2.2.1 Line Arrangement Instructions
Several dedicated tools are available to calculate line arrangements for specific applications and PCB materials - for example from http://www.polarinstruments.com/ (commercial software) or from http://web.awrcorp.com/Usa/Products/Optional-Products/TX-Line/ (free software).
Embedded Stripline
This below figure shows line arrangement examples for embedded stripline.
Figure 5: Embedded Stripline line arrangement
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.2 GSM/UMTS/LTE Antenna Interface
22
Micro-Stripline
This section gives two line arrangement examples for micro-stripline.
Page 18 of 39
Figure 6: Micro-Stripline line arrangement samples
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
e.g. ANT_ MAIN
G N D
G N D
Edge of module PCB
Stripline (50 ohms) on top
layer of evaluation board from
antenna pad to module edge
Width = 0.40 mm
E.g., U.FL antenna
connector
50 ohms microstrip line
G N D G N D
Ground connection
G N D G N D
Page 19 of 39
2.2 GSM/UMTS/LTE Antenna Interface
22
2.2.2.2 Routing Examples
Interface to RF Connector
Figure 7 shows a sample connection of a module‘s antenna pad at the bottom layer of the mod-
ule PCB with an application PCB‘s coaxial antenna connector. Line impedance depends on line width, but also on other PCB characteristics like dielectric, height and layer gap. The sample stripline width of 0.40mm is recommended for an application with a PCB layer stack resembling the one of the PLAS9-X evaluation board. For different layer stacks the stripline width will have to follow stripline routing rules, avoiding 90 degree corners and using the shortest distance to the PCB’s coaxial antenna connector.
PLAS9-X_HIO_v00.044 2017-09-19
Figure 7: Routing to application‘s RF connector
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
e.g.
Ant_
WGSM
G N D
G N D
Ground Connection
Stripline (50 ohms) on top
layer of evaluation board from
antenna pad to module edge
Width = 0,40 mm
G N DG N D
G N D G N D
Edge of Module PCB
E.g. U.FL
antennaconnector
50 ohms micro stripline
Page 20 of 39
2.2 GSM/UMTS/LTE Antenna Interface
22
Figure 8 shows a further sample connection of an evaluation module‘s antenna pad at the bot-
tom layer of the PLAS9-X evaluation module PCB with the PCB‘s coaxial antenna connector. The PLAS9-X evaluation module is part of the reference equipment used by Gema lto M2M for type approval (see also Section 5.3).
Figure 8: Routing to PLAS9-X evaluation module‘s RF connector
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

2.3 Sample Application

22
Page 21 of 39
2.3 Sample Application
Figure 9 shows a typical example of how to integrate an PLAS9-X module with an application.
The PWR_IND line is an open collector that needs an external pull-up resistor which connects to the voltage supply VCC µC of the microcontroller. Low state of the open collector pulls the PWR_IND signal low and indicates that the PLAS9-X module is active, high level notifies the Power Down mode.
If the module is in Power Down mode avoid current flowing from any other source into the mod­ule circuit, for example reverse current from high state external control lines. Therefore, the controlling application must be designed to prevent reverse flow.
While developing SMT applications it is strongly recommended to provide test points for certain signals, i.e., lines to and from the module - for debug and/or test purposes. The SMT application should allow for an easy access to these signals. For details on how to implement test points see [3].
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy for an individual application is very much determined by the overall layout and, especially, the po­sition of components.
Some LGA pads are connected to clocks or high speed data streams that might interfere with the module’s antenna. The RF receiver would then be blocked at certain frequencies (self in­terference). The external application’s PCB tracks connected to these pads should therefore be well shielded or kept away from the antenna. This applies especially to the USB and UICC/ SIM interfaces.
Disclaimer: No warranty, either stated or implied, is provided on the sample schematic diagram shown in
Figure 9 and the information detailed in this section. As functionality and compliance with na-
tional regulations depend to a great amount on the used electronic components and the indi­vidual application layout manufacturers are required to ensure adequate design and operating safeguards for their products using PLAS9-X modules.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.3 Sample Application
22
Page 22 of 39
Figure 9: PLAS9-X sample application
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

3 Operating Characteristics

24
Page 23 of 39
3 Operating Characteristics

3.1 Operating Modes

The table below briefly summarizes the various operating modes referred to throughout the document.
Table 3: Overview of operating modes
Mode Function
Normal operation
Power Down
GSM / GPRS / UMTS / HSPA / LTE SLEEP
GSM / GPRS / UMTS / HSPA / LTE IDLE
GPRS DATA GPRS data transfer in progress. Power consumption depends on net-
EGPRS DATA EGPRS data transfer in progress. Power consumption depends on net-
UMTS DATA UMTS data transfer in progress. Power consumption depends on net-
HSPA DATA HSPA data transfer in progress. Power consumption depends on net-
LTE DATA LTE data transfer in progress. Power consumption depends on network
Normal shutdown after sending the AT^SMSO command. Softwar e is not active. Interfaces are not accessible. Operating voltage (connected to BATT+) remains applied. Only a volt­age regulator is active for powering the RTC, as long as operating voltage applied at BATT+ does not drop below approx. 1.4V.
Power saving set automatically when no call is in progress and the USB connection is detached.
Power saving disabled or an USB connection active , but no data tra ns­fer in progress.
work settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings).
work settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings).
work settings (e.g. TPC Pattern) and data transfer rate.
work settings (e.g. TPC Pattern) and data transfer rate.
settings (e.g. TPC Pattern) and data transfer rate.
Airplane mode
PLAS9-X_HIO_v00.044 2017-09-19
Airplane mode shuts down the radio part of the module , causes th e module to log off from the GSM/GPRS network and disables all AT commands whose execution r equires a rad io connection. Airplane mode can be controlled by AT command (see [1]).
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
BATT+
2 2
Decoupling capacitors e.g. 47µF X5R MLCC
4x
GND
BATT+
BATT+_RF
Module
SMT interface
1x

3.2 Power Supply

24
Page 24 of 39
3.2 Power Supply
PLAS9-X needs to be connected to a power supply at the SMT application interface - 4 lines BATT+, and GND. There are two separate voltage domains for BATT+:
BATT+_RF with 2 lines for the RF power amplifier supply
BATT+ with 2 lines for the general power management. The main power supply from an external application has to be a single voltage source and has
to be expanded to two sub paths (star structure). Each voltage domain must be deco upled by application with low ESR capacitors ( as close as possible to LGA pads. Figure 10 shows a sample circuit for decoupling capacitors for BATT+.
> 47µF MLCC @ BATT+; > 4x47µF MLCC @ BATT+_RF)
Figure 10: Decoupling capacitor(s) for BATT+
The power supply of PLAS9-X must be able to provide the peak current during the uplink trans­mission.
All key functions for supplying power to the device are handled by the power managemen t IC. It provides the following features:
Stabilizes the supply voltages for the baseband using switching regula tors and low drop lin- ear voltage regulators.
Switches the module's power voltages for the power-up and -down procedures.
Delivers, across the VEXT line, a regulated voltage for an external application.
LDO to provide SIM power supply.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
Top view
Bottom view

4 Mechanical Dimensions

26
Page 25 of 39
4 Mechanical Dimensions

4.1 Mechanical Dimensions of PLAS9-X

Figure 11 shows a 3D view1 of PLAS9-X and provides an overview of the board's mechanical
dimensions. For further details see Figure 12. Length: 40mm Width: 32mm Height: 2.8mm
PLAS9-X_HIO_v00.044 2017-09-19
Figure 11: PLAS9-X – top and bottom view
1. The coloring of the 3D view does not reflect the module’s real color.
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
4.1 Mechanical Dimensions of PLAS9-X
26
Page 26 of 39
Figure 12: Dimensions of PLAS9-X (all dimensions in mm)
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

5 Regulatory and Type Approval Information

32
Page 27 of 39
5 Regulatory and Type Approval Information
Note that some regulatory and type approval information is still to be defined.

5.1 Directives and Standards

PLAS9-X has been designed to comply with the directives and standards listed below. It is the responsibility of the application manufacturer to ensure compliance of the final product
with all provisions of the applicable directives and standards as well as with the technical spec­ifications provided in the "PLAS9-X Hardware Interface Description".
Table 4: Directives
1
2002/95/EC (RoHS 1) 2011/65/EC (RoHS 2)
Table 5: Standards of North American type approval
CFR Title 47 Code of Federal Regulations, Part 22, Part 24; US Equipment Authorization
OET Bulletin 65 (Edition 97-01)
UL 60 950-1 Product Safety Certification (Safety requirements)
NAPRD.03 V5.32 Overview of PCS Type certification review board Mobile Equipment Type
RSS132, RSS133, RSS139
Directive of the European Parliament and of the Council of 27 January 2003 (and revised on 8 June 2011) on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
FCC Evaluating Compliance with FCC Guidelines for Human Exposure to
Radiofrequency Electromagnetic Fields
Certification and IMEI control PCS Type Certification Review board (PTCRB)
Canadian Standard
Table 6: Requirements of quality
IEC 60068 Environmental testing DIN EN 60529 IP codes
1. Manufacturers of applications which can be used in the US shall ensure that their applications have a PTCRB approval. For this purpose they can refer to the PTCRB approval of the respective module.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
5.1 Directives and Standards
32
Table 7: Standards of the Ministry of Information Industry of the People’s Republic of China
SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances
in Electronic Information Products” (2006-06).
SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic
Information Products” (2006-06). According to the “Chinese Administration on th e Control of
Pollution caused by Electronic Information Products” (ACPEIP) the EPUP, i.e., Environmental Protection Use Period, of this product is 20 years as per the symbol shown here, unless otherwise marked. The EPUP is valid only as long as the product is operated within the operating limits described in the Hardware Interface Description.
Please see Table 8 for an overview of toxic or hazardous substances or ele­ments that might be contained in product parts in concentrations above the limits defined by SJ/T 11363-2006.
Table 8: Toxic or hazardous substances or elements with defined concentration limits
Page 28 of 39
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

5.2 SAR requirements specific to portable mobile s

32
Page 29 of 39
5.2 SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable PLAS9-X based applications to be evaluated and approved for compliance with national and/or international regulations.
Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For US markets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1 Considerations for evaluation of human exposure to electromagnetic
fields (EMFs) from mobile telecommunication equipment (MTE) in the frequency range 30MHz - 6GHz
IMPORTANT: Manufacturers of portable applications based on PLAS9-X modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate relat­ed to the specific portable mobile.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
V
106
431X506
X202 X201 X 205
X400X401
X110
X120
S112
S110
X121
S111
C413
X410
X411
X405
C415
C414
X510
X511
X5 51X552
X122
S601
X602
X710
TP105
X700
S714
S715
S710
S711
V430
X505
S201
S200
X554
X703
X561
S504S503
S502
S501
S500
S457S452
S456
S455
S453
S454
S450
S460
S451
S461
S462
S464
S465
S463
S466
S469
S459
S467
S458
S468
1
2
3
1
2
3
1
2
3
1
10
1
2
3
1
2
3
1
2
3
1
2
3
123
123
1
2
3
131313
1
1
5
1
1
2
3
1
1
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
1
1
1
1
11
1 4 2 3
15
69
15
69
15
69
11
2
2910
910
2
9
X203
1
X206
X204
1
1
DSB75
3
V
2
3
7
V
2
3
2
V
2
3
6
V
2
3
1
V
2
3
5
V
2
3
0
V
2
3
4
V
2
4
4
V
2
4
3
V
2
4
2
V
2
4
1
V
2
3
9
V
2
4
0
V
2
3
8
V
2
3
3
S
Y
N
C
R
T
S
0
D
S
R
0
D
T
R
0
D
C
D
0
R
I
N
G
0
T
X
D
0
C
T
S
0
R
X
D
0
ALAS6A-
DSB75­Adapter
W
EVAL-Board with module
Power Supply
PC
GSM / UMTS / LTE
Testequipment
U S
B
3
.
0
GSM/UMTS/
LTE
UMTS/LTE
Rx Diversity /
MIMO
Page 30 of 39

5.3 Reference Equipment for Type Approval

32
5.3 Reference Equipment for Type Approval
The Gemalto M2M general reference setup submitted to type approve PLAS9-X is shown in the figure below: Figure 13 illustrates the setup for general tests and evaluation purposes. The evaluation module can be plugged directly onto the ALAS6A-DSB75 ada pter. The GSM/UMTS/ LTE test equipment is still connected via SMA connectors on the ALAS6A-DSB75 a dapter. The PC is connected via USB interface.
Please note that for EMC and RF performance tests, slightly different reference equipment con­figurations are used. If necessary, please contact Gemalto for further details.
Figure 13: Reference equipment for type approval
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

5.4 Compliance with FCC and IC Rules and Regulations

32
Page 31 of 39
5.4 Compliance with FCC and IC Rules and Regulations
The Equipment Authorization Certification for the Gemalto M2M modules refere nce application described in Section 5.3 will be registered under the following identifiers:
•PLAS9-X:
FCC Identifier QIPPLAS9-X Industry Canada Certification Number: 7830A-PLAS9X Granted to Gemalto M2M GmbH
Manufacturers of mobile or fixed devices incorporating PLAS9-X modules are authorized to use the FCC Grants and Industry Canada Certificates of the PLAS9-X modules for their own final products according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device sha ll bear a second label stating "Contains FCC ID: QIPPLAS9-X" and accordingly “Contains IC: 7830A-PLAS9X“. The integration is limited to fixed or mobile categorized host devices, where a separation distance between the antenna and any person of min. 20cm can be assured during normal operating conditions.
For mobile and fixed operation configurations the antenna gain, including cable loss, must not exceed the limits listed in the following Table 9 for FCC and IC.
Table 9: Antenna gain limits for FCC and IC (TBD.)
Maximum gain in operating band FCC limit IC limit Unit
Band12, Band13, Band 29 700MHz (LTE) dBi Band 5, 850MHz (GSM/WCDMA/LTE) dBi Band 4, 1700MHz (WCDMA/LTE) dBi Band 2, 1900MHz (GSM/WCDMA/LTE) dBi
IMPORTANT: Manufacturers of portable applications incorporating PLAS9-X modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for por­table mobiles (see Section 5.2 for detail).
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
5.4 Compliance with FCC and IC Rules and Regulations
32
Page 32 of 39
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). These limits are designed to provide reasonable protection against harmful inter­ference in a residential installation. This equipment generates, uses and can radiate radio fre­quency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This Class B digital apparatus complies with Canadian ICES-003. If Canadian approval is requested for devices incorporating PLAS9-X modules the above note
will have to be provided in the English and French language in the final user documentation. Manufacturers/OEM Integrators must ensure that the final user documentation does not con­tain any information on how to install or remove the module from the final product.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

6 Document Information

36
Page 33 of 39
6 Document Information

6.1 Revision History

New document: "Cinterion® PLAS9-X Hardware Interface Overview" Version 00.044
Chapter What is new
-- Initial document setup.

6.2 Related Documents

[1] PLAS9-X AT Command Set [2] PLAS9-X Release Note [3] Application Note 48: SMT Module Integration [4] Universal Serial Bus Specification Revision 3.0 [5] Universal Serial Bus Specification Revision 2.0

6.3 Terms and Abbreviations

Abbreviation Description
ANSI American National Standards Institute ARP Antenna Reference Point CA Carrier Aggregation CE Conformité Européene (European Conformity) CS Coding Scheme CS Circuit Switched CSD Circuit Switched Data DL Download dnu Do not use DRX Discontinuous Reception DSB Development Support Board DTX Discontinuous Transmission EDGE Enhanced Data rates for GSM Evolution EGSM Extended GSM EMC Electromagnetic Compatibility ESD Electrostatic Discharge ETS European Telecommunication Standard
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
6.3 Terms and Abbreviations
36
Abbreviation Description
ETSI European Telecommunications Standards Institute FCC Federal Communications Commission (U.S.) FDD Frequency Division Duplex GPRS General Packet Radio Service GSM Global Standard for Mobile Communications HiZ High Impedance HSDPA High Speed Downlink Packet Access I/O Input/Output IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second
Page 34 of 39
LED Light Emitting Diode LGA Land Grid Array LTE Long term evolution MBB Moist ur e ba rr ier bag Mbps Mbits per second MCS Modulation and Coding Scheme MFBI Multiple Frequency Band Indicator MIMO Multiple Input Multiple Output MLCC Multi Layer Ceramic Capacitor MO Mobile Originated MS Mobile Station, also referred to as TE MSL Moisture Sensitivity Level MT Mo b ile Te rm in at ed nc Not connected NTC Negative Temperature Coefficient PCB Printed Circuit Board PCL Power Control Level PCS Personal Communication System, also referred to as GSM 1900 PD Pull Down resistor PDU Protocol Data Unit PS Packet Switched PSK Phase Shift Keying PU Pull Up resistor QAM Quadrature Amplitude Modulation
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
6.3 Terms and Abbreviations
36
Abbreviation Description
R&TTE Radio and Telecommunication Terminal Equipment RF Radio Frequency rfu Reserved for future use ROPR Radio Output Power Reduction RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SELV Safety Extra Low Voltage SIM Subscriber Identification Module SMD Surface Mount Device SMS Short Message Service SMT Surface Mount Technology
Page 35 of 39
SRAM Static Random Access Memory SRB Signalling Radio Bearer TE Terminal Equipment TPC Transmit Power Control TS Technical Specification Tx Transmit Direction UL Upload UMTS Universal Mobile Telecommunications System URC Unsolicited Result Code USB Universal Serial Bus UICC USIM Integrated Circuit Card USIM UMTS Subscriber Identification Module WCDMA Wideband Code Division Multiple Access
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

6.4 Safety Precaution Notes

36
Page 36 of 39
6.4 Safety Precaution Notes
The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating PLAS9-X. Manufacturers o f the cellular terminal are advised to convey the following safety information to users and ope rating personnel and to incorporate these guidelines into all manuals supplied with the product. Fail­ure to comply with these precautions violates safety standards of design, manufacture and in­tended use of the product. Gemalto M2M assumes no liability for customer’s failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guide­lines posted in sensitive areas. Medical equipment may be sensitive to RF energy. The operation of cardiac pacemakers, other implanted medical equipment and hear­ing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufa c­turer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their hand-held mob ile a way from the pace maker , while it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make sure it can­not be switched on inadvertently. The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel depots, chemical plants or where blasting operations are in progress. Operation of any elec­trical equipment in potentially explosive atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special regulations and always switch off the cellular terminal or mobile wherever forbidd en, or when you suspect that it may cause interference or danger.
IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential com­munications, for example emergency calls. Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength. Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellular termi­nal or mobile.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview

7 Appendix

38
7 Appendix

7.1 List of Parts and Accessories

Table 10: List of parts and accessories
Description Supplier Ordering information
PLAS9-X Gemalto M2M Standard module
Gemalto M2M IMEI: Packaging unit (ordering) number: L30960-N5130-B100 Module label number: L30960-N5130-B100-1
PLAS9-X Evaluation module Gemalto M2M Ordering number: TBD. (PLAS9)
DSB75 Support Box Gemalto M2M Ordering number: L36880-N8811-A100
1
Page 37 of 39
Votronic Handset VOTRONIC /
Gemalto M2M
SIM card holder incl. push button ejector and slide-in tray
U.FL
antenna connector Molex or
1. Note: At the discretion of Gemalto M2M, module label information can either be laser engraved on the module’s shielding or be printed on a label adhered to the module’s shielding.
Molex Ordering numbers: 91228
Hirose
Gemalto M2M ordering number: L36880-N8301-A10 7 Votronic ordering number: HH-SI-30.3/V1.1/0
Votronic Entwicklungs- und Produktionsgesellschaft für elek­tronische Geräte mbH Saarbrücker Str. 8 66386 St. Ingbert Germany Phone: +49-(0)6 89 4 / 92 55-0 Fax: +49-(0)6 89 4 / 92 55-88 Email: contact@votronic.com
91236
Sales contacts are listed in Table 11. Sales contacts are listed in Table 11 and Table 12.
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
7.1 List of Parts and Accessories
38
Table 11: Molex sales contacts (subject to change)
Page 38 of 39
Molex For further information please click:
http://www.molex.com
Molex China Distributors Beijing, Room 1311, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Fax: +86-10-6526-9730
Table 12: Hirose sales contacts (subject to change)
Hirose Ltd. For further information please click:
http://www.hirose.com
Molex Deutschland GmbH Otto-Hahn-Str. 1b 69190 Walldorf Germany Phone: +49-6227-3091-0 Fax: +49-6227-3091-8100 Email: mxgermany@molex.com
Molex Singapore Pte. Ltd. 110, International Road Jurong Town, Singapore 629174
Phone: +65-6-268-6868 Fax: +65-6-265-6044
Hirose Electric (U.S.A.) Inc 2688 Westhills Court Simi Valley, CA 93065 U.S.A.
Phone: +1-805-522-7958 Fax: +1-805-522-3217
American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352
Molex Japan Co. Ltd. 1-5-4 Fukami-Higashi, Yamato-City, Kanagawa, 242-8585 Japan
Phone: +81-46-265-2325 Fax: +81-46-265-2365
Hirose Electric Europe B.V. German Branch: Herzog-Carl-Strasse 4 73760 Ostfildern Germany
Phone: +49-711-456002-1 Fax: +49-711-456002-299 Email: info@hirose.de
Hirose Electric Europe B.V. UK Branch: First Floor, St. Andrews House, Caldecotte Lake Business Park, Milton Keynes MK7 8LE Great Britain
Phone: +44-1908-369060 Fax: +44-1908-369078
Hirose Electric Co., Ltd. 5-23, Osaki 5 Chome, Shinagawa-Ku Tokyo 141 Japan
Phone: +81-03-3491-9741 Fax: +81-03-3493-2933
Hirose Electric Europe B.V. Hogehillweg 8 1101 CC Amsterdam Z-O Netherlands
Phone: +31-20-6557-460 Fax: +31-20-6557-469
PLAS9-X_HIO_v00.044 2017-09-19
Confidential / Preliminary
39
About Gemalto
Since 1996, Gemalto has been pioneering groundbreaking M2M and IoT products that keep our customers on the leading edge of innovation.
®
We work closely with global mobile network operators to ensure that Cinterion in sync with wireless networks, providing a seamless migration path to protect your IoT technology investment.
Cinterion products integrate seamlessly with Gemalto identity modules, security solutions and licensing and monetization solutions, to streamline development timelines and provide cost efficiencies that improve the bottom line.
As an experienced software provider, we help customers manage connectivity, security and quality of service for the long lifecycle of IoT solutions.
modules evolve
For more information please visit
www.gemalto.com/m2m, www.facebook.com/gemalto, or Follow@gemaltoIoT on Twitter.
Gemalto M2M GmbH
Werinherstrasse 81 81541 Munich Germany
GEMALTO.COM/M2M
© Gemalto 2017. All rights reserved. Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain countries.
Loading...