THE USE OF THE PRODUCT INCLUDING THE SOFTWARE AND DOCUMENTATION (THE "PRODUCT") IS SUBJECT TO THE RELEASE NOTE PROVIDED TOGETHER WITH PRODUCT. IN ANY
EVENT THE PROVISIONS OF THE RELEASE NOTE SHALL PREVAIL. THIS DOCUMENT CONTAINS
INFORMATION ON GEMALTO M2M PRODUCTS. THE SPECIFICATIONS IN THIS DOCUMENT ARE
SUBJECT TO CHANGE AT GEMALTO M2M'S DISCRETION. GEMALTO M2M GMBH GRANTS A NONEXCLUSIVE RIGHT TO USE THE PRODUCT. THE RECIPIENT SHALL NOT TRANSFER, COPY,
MODIFY, TRANSLATE, REVERSE ENGINEER, CREATE DERIVATIVE WORKS; DISASSEMBLE OR
DECOMPILE THE PRODUCT OR OTHERWISE USE THE PRODUCT EXCEPT AS SPECIFICALLY
AUTHORIZED. THE PRODUCT AND THIS DOCUMENT ARE PROVIDED ON AN "AS IS" BASIS ONLY
AND MAY CONTAIN DEFICIENCIES OR INADEQUACIES. TO THE MAXIMUM EXTENT PERMITTED
BY APPLICABLE LAW, GEMALTO M2M GMBH DISCLAIMS ALL WARRANTIES AND LIABILITIES.
THE RECIPIENT UNDERTAKES FOR AN UNLIMITED PERIOD OF TIME TO OBSERVE SECRECY
REGARDING ANY INFORMATION AND DATA PROVIDED TO HIM IN THE CONTEXT OF THE DELIVERY OF THE PRODUCT. THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED
ACCORDING TO GERMAN LAW.
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without ex press autho rization are prohib ited. Offenders will be
held liable for payment of damages. All rights created by patent grant or registration of a utility model or
design patent are reserved.
Gemalto, the Gemalto logo, are trademarks and service marks of Gemalto and are registered in certain
countries. Microsoft and Win dows are e ither regis tered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. All other register ed trademarks or trademarks mention ed
in this document are property of their respective owners.
Figure 10:Decoupling capacitor(s) for BATT+................................................................ 24
Figure 11:PLAS9-X – top and bottom view.................................................................... 25
Figure 12:Dimensions of PLAS9-X (all dimensions in mm)............................................ 26
Figure 13:Reference equipment for type approval......................................................... 30
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
1 Introduction
9
Page 6 of 39
1Introduction
This document1 describes the hardware of the Cinterion® PLAS9-X module. It helps you quickly
retrieve interface specifications, electrical and mechanical details and information on the requirements to be considered for integrating further components.
1.1Key Features at a Glance
FeatureImplementation
General
Frequency bandsGSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
(board temperature)
PhysicalDimensions: 40mm x 32mm x 2.8mm
Class 4 (+33dBm ±2dB) for EGSM850
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII
Class 3 (+24dBm +1/-3dB) for UMTS 1700, WCDMA FDD BdIV
Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
LTE (FDD):
Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD Bd12 <MFBI Bd17>
Class 3 (+23dBm +-2dB) for LTE 700, LTE FDD Bd13
Class 3 (+23dBm +-2dB) for LTE 850, LTE FDD Bd5
Class 3 (+23dBm +-2dB) for LTE 1700, LTE FDD Bd4
Class 3 (+23dBm +-2dB) for LTE1900, LTE FDD Bd2
V
Normal operation: -30°C to +85°C
Extended operation: -40°C to +95°C
Weight: approx. 6.5g
BATT+
< 4.2V
RoHSAll hardware components fully compliant with EU RoHS Directive
1. The document is effective only if listed in the appropriate Release Notes as part of the technical documentation delivered with your Gemalto M2M product.
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
1.1 Key Features at a Glance
9
FeatureImplementation
LTE features
3GPP Release 10Downlink carrier aggregation (CA) to increase bandwidth, and thereby
increase bitrate:
•Maximum aggregated bandwidth: 40MHz
•Maximum number of component carriers: 2
•Inter-band FDD, non-contiguous
•Intra-band FDD, contiguous, non-contiguous
•Supported inter-band CA configurations:
CA_2A-5A (with bandwidth combination set 0),
CA_2A-12A (with bandwidth combination sets 0 and 1),
CA_2A-29A (with bandwidth combina tio n se ts 0, 1 and 2),
CA_4A-5A (with bandwidth combination sets 0 and 1),
CA_4A-12A (with bandwidth combination sets 0, 1, 2, 3 and 4),
CA_4A-29A (with bandwidth combina tio n se ts 0, 1 and 2)
•Supported intra-band CA configurations:
CA_4A-4A (with bandwidth combination set 0)
CAT 6 supported
DL 300Mbps, UL 50Mbps
2x2 MIMO in DL direction
Page 7 of 39
HSPA features
3GPP Release 9UE CAT. 14, 24
DC-HSPA+ – DL 42Mbps
HSUPA – UL 5.76Mbps
Compressed mode (CM) supported according to 3GPP TS25.212
UMTS features
3GPP Release 9PS data rate – 384 kbps DL / 384 kbps UL
GSM / GPRS / EGPRS features
Data transferGPRS:
•Multislot Class 12
•Mobile Station Class B
•Coding Scheme 1 – 4
EGPRS:
•Multislot Class 12
•EDGE E2 power class for 8 PSK
•Downlink coding schemes – CS 1-4, MCS 1-9
•Uplink coding schemes – CS 1-4, MCS 1-9
•SRB loopback and test mode B
•8-bit, 11-bit RACH
•1 phase/2 phase access procedures
•Link adaptation and IR
•NACC, extended UL TBF
•Mobile Station Class B
SMSPoint-to-point MT and MO, Cell broadcast,
Text and PDU mode
Software
AT commandsHayes, 3GPP TS 27.007 and 27.005, and proprietary Gemalto M2M com-
mands
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
1.1 Key Features at a Glance
9
FeatureImplementation
Firmware updateGeneric update from host application over USB 2.0 High Speed device
interface
Interfaces
Module interfaceSurface mount device with solderable connection pads (SMT application
interface).
Land grid array (LGA) technology ensures high solder joint reliability and
provides the possibility to use an optional module mounting socket.
For more information on how to integrate SMT modules see also [3]. This
application note comprises chapters on module mounting and app lication
layout issues as well as on additional SMT application development equip-
ment.
Antenna50. GSM/UMTS/LTE main antenna, UMTS/LTE Diversity/MIMO antenna
USBUSB 2.0 High Speed (480Mbit/s) device interface or
USB 3.0 Super Speed (5Gbit/s) device interface
UICC interface2 UICC interfaces (switchable)
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
Page 8 of 39
RING0Signal line to indicate URCs.
Power on/off, Reset
Power on/offSwitch-on by hardware signal IGT
Switch-off by AT command (AT^SMSO) or IGT (option)
Automatic switch-off in case of critical temperature or voltage conditions
ResetOrderly shutdown and reset by AT command
Emergency-offEmergency-off by hardware signal EMERG_OFF
Special Features
AntennaSAIC (Single Antenna Interference Cancellation) / DARP (Downlink
Advanced Receiver Performance)
Rx Diversity (receiver type 3i - 64-QAM) / MIMO
GPIO10 I/O pins of the application interface programmable as GPIO.
Programming is done via AT commands.
ADC inputsAnalog-to-Digital Converter with two unbalanced analog inputs for (exter-
nal) antenna diagnosis
Evaluation kit
Evaluation modulePLAS9-X module soldered onto a dedicated PCB that can be connected
to the ALAS6A-DSB75 adapter in order to be mounted onto the DSB75.
ALAS6A-DSB75 adapterA special adapter required to connect the PLAS9-X evaluation module to
the DSB75.
DSB75 DSB75 Development Support Board designed to test and type approve
Gemalto M2M modules and provide a sample configuration for application
engineering.
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
GPIOADCUICC
Power
supply
IGT,
Emergency Off
SIM
card
Hos t application
On/Off
Module
Application
Power indication
(PWR_IND)
GSM/UMTS/LTE
Power for application
(VEXT)
USB
GSM/UMTS/LTE
Ant enna d iv ersi ty
12
Antenna
diagnostic
Antenna
switch
2x
GPIO
2x
ADC
SIM
card
RING0
1.2 PLAS9-X System Overview
9
1.2PLAS9-X System Overview
Page 9 of 39
Figure 1: PLAS9-X system overview
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
VREG (3V075)
BATT+
USB_DP
3)
lin. reg.
GND
Module
Detection only
VUSB_IN
2)
USB part
1)
1)
All serial (including RS) and pull-up resistors for da ta lines are implemented.
USB_DN
3)
3)
If the USB interface is op erated in High Speed mode (480MHz), it is recommen ded to take special care routing the data
lines USB_DP and USB_DN. Application layout should in this case implement a differen tial impedance of 90 ohms for
proper signal integrity.
VBUS
1µF
2)
Since VUSB_IN is used for detection only it is recommended not to add any further blocking capacitors on
the VUSB_IN line.
Host wakeup
RING0
USB_SSRX_N
USB_SSRX_P
USB_SSTX_N
USB_SSTX_P
USB_SS
_PHY
USB_HS
_PHY
USB 2.0
Controller
USB 3.0
Controller
2.0
2.0
3.0
100nF
100nF
SMT
Page 10 of 39
2 Interface Characteristics
22
2Interface Characteristics
PLAS9-X is equipped with an SMT application interface that connects to the external application. The SMT application interface incorporates the various application interfaces as well as
the RF antenna interface.
2.1Application Interface
2.1.1USB Interface
PLAS9-X supports a USB 3.0 Super Speed (5Gbps) device interface, and alternatively a
USB 2.0 device interface that is High Speed and Full Speed compatible. The USB interface is
primarily intended for use as command and data interface, and for downloading firmware
The USB host is responsible for supplying the VUSB_IN line. This line is for voltage detection
only. The USB part (driver and transceiver) is supplied by means of BATT+. This is because
PLAS9-X is designed as a self-powered device compliant with the “Universal Serial Bus Spec-
2
ification Revision 3.0”
.
1
.
To properly connect the module's USB interface to the external application, a USB 3.0 or 2.0
compatible connector and cable or hardware design is required. Furthermore, the USB modem
driver distributed with PLAS9-X needs to be installed.
1. Note: For firmware download, the module enumerates new as a USB 2.0 device. Also, it is not possible
Figure 2: USB circuit
to use the USB 2.0 High Speed device mode and the USB 3.0 Super speed device mode simultaneously.
2. The specification is ready for download on http://www.usb.org/developers/docs/
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
2.1 Application Interface
22
Page 11 of 39
2.1.2UICC/SIM/USIM Interface
PLAS9-X has two UICC/SIM/USIM interfaces compatible with the 3GPP 31.102 and ETSI 102
221. These are wired to the host interface in order to be connected to an external SIM card
holder. Five pads on the SMT application interface are reserved for each of the two SIM interfaces.
The UICC/SIM/USIM interface supports 3V and 1.8V SIM cards.
The CCINx signal serves to detect whether a tray (with SIM card) is present in the card holder.
Using the CCINx signal is mandatory for compliance with the GSM 11.11 recommendation if
the mechanical design of the host application allows the user to remove the SIM card during
operation. To take advantage of this feature, an appropriate SIM card detect switch is required
on the card holder. For example, this is true for the model supplied by Molex, which has been
tested to operate with PLAS9-X and is part of the Gemalto M2M reference equipment submitted for type approval. See Chapter 7 for Molex ordering numbers.
Table 1: Signals of the SIM interface (SMT application interface)
SignalDescription
GNDGround connection for SIM interfaces. Optionally a separate SIM ground line using e.g.,
pad P12, may be used to improve EMC.
CCCLK1
CCCLK2
CCVCC1
CCVCC2
CCIO1
CCIO2
CCRST1
CCRST2
CCIN1
CCIN2
Chipcard clock lines for 1
SIM supply voltage lines for 1
Serial data lines for 1
Chipcard reset lines for 1
Input on the baseband processor for detecting a SIM card tray in the holder. If the SIM is
removed during operation the SIM interface is shut down immediately to prevent destruction of the SIM. The CCINx signal is active low.
The CCINx signal is mandatory for applications that allow the user to remove the SIM card
during operation.
The CCINx signal is solely intended for use with a SIM card. It must not be used for any
other purposes. Failure to comply with this requirement may inva lidate the type approval of
PLAS9-X.
st
and 2nd SIM interface.
st
and 2nd SIM interface.
st
and 2nd SIM interface, input and output.
st
and 2nd SIM interface.
Note: No guarantee can be given, nor any liability accepted, if loss of data is encountered after
removing the SIM card during operation. Also, no guarantee can be given for properly initializing any SIM card that the user inserts after having removed the SIM card during operation. In
this case, the application must restart PLAS9-X.
By default, only the 1
st
SIM interface is available and can be used. Using the AT command
AT^SCFG=”SIM/CS” it is possible to switch between the two SIM interfaces. Command settings are non-volatile - for details see [1].
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Cinterion® PLAS9-X Hardware Interface Overview
Module
open: Card removed
closed: Card inserted
CCRST1
CCVCC1
CCIO1
CCCLK1
CCIN1
SIM /
UICC
1n
220n
SMT application interface
GND
Module
Open: Card removed
Closed: Card inserted
CCRST2
CCVCC2
CCIO2
CCCLK2
CCIN2
SIM /
UICC
1nF
220nF
SMT application interface
GND
VEXT
100pF
22k
2k2
10k
2.1 Application Interface
22
Figure 3: First UICC/SIM/USIM interface
Page 12 of 39
The total cable length between the SMT application interface pads on PLAS9-X and the pads
of the external SIM card holder must not exceed 100mm in order to meet the specifications of
3GPP TS 51.010-1 and to satisfy the requirements of EMC compliance.
To avoid possible cross-talk from the CCCLKx signal to the CCIOx signal be careful that both
lines are not placed closely next to each other. A useful approach is using the GND line to
shield the CCIOx line from the CCCLKx line.
Note: Figure 3 shows how to connect a SIM card holder to the first SIM interface . With the second SIM interface some internally integrated components on the SIM circuit will have to be externally integrated as shown for the second SIM interface in Figure 4. The external co mponents
at CCIN2 should be populated as close as possible to the signal‘s SMT pad
Figure 4: Second UICC/SIM/USIM interface
PLAS9-X_HIO_v00.0442017-09-19
Confidential / Preliminary
Loading...